SDR WWMA9700085Smoke Detector · failedCARGO SMOKE DETECTOR FAILS TO TEST PROPERLY. REPLACED THE AFT CARGO SMOKE DETECTOR.SDR IXKA9700045Smoke Detector · inoperativeAT ATL, FOUND LEFT AFT LAV SMOKE DETECTOR INOP. REMOVED AND REPLACED LEFT AFT LAV SMOKE DETECTOR, OPS CHECK OK AS PER MM 26-18-0. (M)SDR EISA97116Smoke Detector · activatedCARGO SMOKE DETECTOR CAME ON AROUND 12,000 FEET TO LANDING. PERFORMED GROUND OPS CHECK, COULD NOT DUPLICATE. (M)SDR QXEA9700227Smoke Detector · no testNR 2 BAGGAGE SMOKE DETECTOR IN THE CARGO COMPARTMENT WILL NOT TEST. PLACED ON MEL, REFERENCE 26-6.SDR WWMA9700083Smoke Detector · no testCARGO SMOKE WARNING LIGHT FAILED TO ILLUMINATE DURING PREFLIGHT SMOKE DETECTOR TEST. REPLACED CARGO FOWARD SMOKE DETECTOR.SDR VTZA97309Smoke Detector · failedFLT 6192 - RDU-IAD - DURING CRUISE, MADE AN SCHEDULED LANDING AT IAD WITH ONE DISCREPANCY WHICH WAS SMOKE WARNING CAPTION LIGHT ILLUMINATED. AIRCRAFT WENT TO GATE AT IAD WITH NO FURTHER PROBLEMS. MAINTENANCE INSPECTED AND REMOVED AND REPLACED POD SMOKE DETECSDR QXEA9700215Smoke Detector · no testNR 1 BAGGAGE SMOKE DETECTOR WILL NOT TEST. REPLACED TEST LAMPS, OPERATIONAL CHECKS GOOD.SDR QXEA9700213Smoke Detector · dirtySMOKE DETECTOR IN LAVATORY IS INOP. CLEANED SMOKE DETECTOR, OPERATIONAL CHECKS GOOD.SDR EISA97108Smoke Light · illuminatedON DESCENT RED CARGO SMOKE LIGHT ILLUMINATED, NO SMOKE WAS OBSERVED IN A/C, EXTINGUISHED AFTER 5 MIN. INSPECTED ALL DETECTORS, SECURED SENSE LINES CLEANED WATER SOCKS, OPS CHECK OK. (M)SDR RAIA970523Smoke Detector · error warnSTL - FLT 7462 - POD SMOKE CAPTION CAME ON IN CRUISE. FLIGHT DIVERTED TO PAH. MAINTENANCE REPLACED POD SMOKE DETECTOR. (X)SDR WWMA9700084Smoke Detector · defectiveDURING FLIGHT, THE CARGO SMOKE LIGHT CAME ON 3 TO 4 TIMES MOMEMTARILY THEN WENT OUT. REPLACED BOTH FORWARD AND AFT CARGO SMOKE DETECTORS.SDR QXEA9700208Smoke Detector · malfunctionLEFT HAND LAVATORY SMOKE DETECTOR SOUNDS IN FLIGHT. DETECTOR IS ABLE TO BE RESET. NO SMOKE OR SMELL NOTED WITHIN CABIN AND LAVATORY. REPLACED LEFT LAVATORY SMOKE DETECTOR, OPERATIONAL CHECKS GOOD.SDR TSAA9726109Smoke Detector · activatedHNL/KOA - FLT 36 - PILOT REPORT, FORWARD CARGO SMOKE DETECTOR ILLUMINATED WITH BELL IN-FLIGHT. REPLACED BULB. (X)SDR WWMA9700080Smoke Detector · no testDURING PREFLIGHT, THE LAVATORY SMOKE LIGHT WOULD NOT TEST. PERFORMED OPERATIONAL CHECK OF THE LAVATORY SMOKE DETECTOR, COULD NOT DUPLICATE PROBLEM.SDR WWMA9700079Smoke Detector · defectiveLAVATORY SMOKE LIGHT ILLUMINATED. REPLACED LAVATORY SMOKE DETECTOR.SDR WTAA970091Smoke Detector · malfunctionedSMF - AFT BAGGAGE COMPT SMOKE LIGHT ILLUMINATED. MX CLEANED SMOKE DETECTOR, RAN RT ENG WITH BLEEDS AND RICIRCULATION FAN ON. COULD NOT DUPLICATE SMOKE INDICATION. MX DEFERRED RECIRCULATION FAN AS PRECAUTION. A/C RETURNED TO SERVICE. MX SUBSEQUENTLY CLEARESDR PLGA970523ASmoke Det · malfunctionedHPN - FLT 4780 - ON TAKEOFF CREW RECEIVED AN AVIONICS SMOKE DETECTOR WARNING. TAKEOFF WAS ABORTED AND AIRCRAFT RETURNED TO THE GATE. MAINTENANCE INSPECTED AVIONICS AREA AND FOUND. NO SIGNS OF SMOKE OR FIRE. DETECTOR WAS FOUND TO BE AT FAULT. DETECTOR WAS SDR DLM11970993Smoke Detector · activatedF/A REPORTED, PASSENGER CAUGHT SMOKING IN 3R LAV. PAX DROPPED CIGARETTE IN LAV TRASH BIN WHICH CAUSED A SMOLDERING FIRE. EXTINGUISHED BY COFFEE AND WATER. INSPECTED TRASH BIN THERMAL SENSOR, NO HEAT DETECTED. INSPECTED TRASH BIN FIRE EXTINGUISHER, NOT DISCSDR TAOA059710Smoke Detector · failedFLT 6440 - DCA-LGA - SMOKE DETECTOR WENT OFF IN AFT LAVATORY DURING TAXI, RETURNED TO GATE. REPLACED AFT LAVATORY SMOKE DETECTOR, OPERATIONAL CHECKS NORMAL PER MM CHAPTER 26. (M)SDR GTIA9700299Smoke Detector · malfunctionedAFT LAV SMOKE ALARM ACTIVATED IN FLIGHT, NO SMOKE IN LAVATORY. ALARM WAS TEMPORARILY SILENCED WHEN TEST SWITCH ACTIVATED, BUT THEN ALARM WAS CONSTANT. DEFERED RT LAVATORY IAW MEL 26-7 DMI NR 00548 CAT 'C' DUE 5-29-97. TRASH CHECKED AND DOOR LOCKED. REMOVESDR GTIA9700286Smoke Detector · jammed switchDTW - FLT 640 - AFT LAV SMOKE DETECTOR ACTIVATED SPURIOUSLY IN-FLIGHT. FOUND TEST SWITCH JAMMED IN CLOSE TO TEST MODE. UN-JAMMED SWITCH. SEVERAL OPS CHECKS COMPLETED. ALL CHECKS GOOD. (X)SDR WWMA9700078Smoke Detector · defectiveLAVATORY SMOKE LIGHT INTERMITTENTLY ILLUMINATED. REPLACED THE LAVATORY SMOKE DETECTOR.SDR WWMA9700076Smoke Detector · defectiveTHE CARGO SMOKE LIGHT ILLUMINATED FOR A SECOND OR LESS SHORTLY AFTER THE CARGO DOOR WAS OPENED ON THE RAMP. REPLACED BOTH CARGO SMOKE DETECTORS.SDR DLM88970942Smoke Detector · malfunctionedAT TOP OF DESCENT FL330, F/A REPORTS BOTH AFT SMOKE DETECTORS GOING OFF. F/O CKD FOR SMOKE/HT, NONE NOTED. AFTER REACHING CRZ- SMOKE DETECTORS SHUT OFF. CHECKED INLET AND EXHAUST ON BOTH ENGINES. CHECKED LEFT AND RIGHT ACMS. STEAMED CLEANED APU INLET, ALLSDR SCNA97173Wire · damagedTHE FORWARD LAVATORY SMOKE DETECTOR WAS FOUND TO BE INOPERATIVE. FOUND DAMAGED WIRES. REPAIRED WIRES, DETECTOR CHECKED NORMAL.SDR WWMA9700072Smoke Detector · intermittentLAVATORY SMOKE DETECTOR LIGHT CAME ON INTERMITTENTLY IN FLIGHT. REPLACED THE LAVATORY SMOKE DETECTOR.SDR WWMA9700069Smoke Detector · defectiveLAVATORY SMOKE LIGHT ILLUMINATES WHEN A PERSON ENTERS THE LAVATORY. REPLACED THE LAVATORY SMOKE DETECTOR.SDR WTAA970079Smoke Light · illuminatedSBP - AFT LAVATORY SMOKE DETECTOR LIGHT ILLUMINATED IN FLIGHT. FLIGHT ATTENDANT TURNED OFF ALL GALLEY EQUIPMENT, LIGHT EXTINGUISHED. AIRCRAFT LANDED WITHOUT INCIDENT. AIRCRAFT FERRIED TO SFO FOR INSPECTION AND REPAIRS. MX INSPECTED AFT LAVATORY SMOKE DETECSDR WWMA9700064Smoke Detector · defectiveAVIONICS SMOKE LIGHT INDICATION CAME ON MOMENTARILY, AFTER 5 MINUTES IT CAME ON AGAIN MOMENTARILY. SMOKE LIGHT CAME ON FOR THE 3RD TIME AND STAYED ON FOR THE REMAINDER OF THE FLIGHT. REPLACED THE AVIONICS SMOKE DETECTOR.SDR EISA97103Smoke Light · illuminatedCARGO SMOKE WARNING LIGHT ILLUMINATED ON APPROACH. COMPLETED PROCEDURES PER AOM. PERFORMED OPERATIONAL CHECKOUT OF CARGO SMOKE DETECTION SYSTEM. OPS CHECK GOOD PER MM 26. NO DEFECTS NOTED. (M)SDR SCNA97142Smoke Detector · failedTHE NUMBER 6 LAVATORY SMOKE DETECTOR WAS FOUND TO GIVE A VERY SLOW ALERT AND NO LAV SMOKE INDICATION WAS RECEIVED IN COCKPIT. REMOVED AND REPLACED LAVATORY SMOKE DETECTOR, DETECTOR OPS CHECKED GOOD.SDR WWMA9700062Smoke Detector · defectiveAVIONICS SMOKE LIGHT ILLUMINATED INTERMITTENTLY 6 TIMES IN FLIGHT, THEN ON THE GROUND. NO SMOKE WAS NOTED BY THE CREW. MAINTENANCE REPLACED THE AVIONICS SMOKE DETECTOR.SDR WWMA9700061Smoke Detector · dirtyCREW REPORTS, THE LAVATORY SMOKE LIGHT WAS GOING ON AND OFF INTERMITTENTLY. A VISUAL INSPECTION WAS PERFORMED WITH NOTHING UNUSUAL NOTED. MAINTENANCE DEFERRED THE SMOKE DETECTOR IAW THE MEL 26-2-2. THE MEL WAS CLEARED AT THE NEXT STATION BY CLEANING THE SMOSDR QXEA9700164Smoke Detector · defectiveNR 2 SMOKE DETECTOR IN BAGGAGE COMPARTMENT WON'T TEST. REPLACED SMOKE DETECTOR, OPERATIONAL CHECKS GOOD.SDR HNAA9790649Smoke Detector · out of adjustFLT 3394 - RIC-BWI - THE LAVATORY SMOKE DETECTOR WENT OFF IN FLIGHT. THE TEST SWITCH WAS MOVING TO TEST POSITION CAUSING IT TO ALARM. ADJUSTED THE TEST SWITCH. OPS CHECK GOOD. (M)SDR VTZA97252Smoke Detector · dirtyIAD/RDU - FLT 6576 - DURING APPROACH AT 1000 HRS ON 4-28-97, MADE A SCHEDULED LANDING AT RDU WITH ONE DISCREPANCY WHICH WAS THE POD SMOKE DETECTOR WARNING LIGHT ILLUMINATED. MAINTENANCE INSPECTED AND OPENED DMI 05821, MEL 26-1. MAINTENANCE CLOSED DMI 05821 OSDR IXKA9700021Smoke Detector · inopRIGHT AFT LAVATORY SMOKE DETECTOR INOP. REMOVED AND REPLACED RIGHT AFT AFT LAVATORY SMOKE DETECTOR PER MM 26-17-0. (M)SDR WWMA9700058Smoke Detector · defectiveDURING PREFLIGHT, THE LAVATORY SMOKE LIGHT WARNING ILLUMINATED. REPLACED THE LAVATORY SMOKE DETECTOR.SDR RAIA970423Smoke Detector · dirtyBNA - FLT 7253 - POD SMOKE LIGHT ILLUMINATED IN-FLIGHT. MAINTENANCE CLEANED PHOTO CELL ON POD SMOKE DETECTOR. (X)SDR QXEA9700143Smoke Detector · inoperativeNR 2 SMOKE DETECTOR IN THE CARGO COMPARTMENT WON'T TEST. REPLACED NR 2 SMOKE DETECTOR, OPERATIONAL CHECK NORMAL.SDR CA970505030Smoke Detector · activated(CAN) ON CLIMB OUT AT APPROXIMATELY FL280 ECAM MESSAGE, FROWARD CARGO SMOKE INDICATION. BOTH FIRE BOTTLES (P/N 472931-2 AND 472930-2) ACTIVATED. FLIGHT CREW CHECKED FORWARD CARGO HOLD FOR FIRE IN FLIGHT. NO EVIDENCE OF FIRE FOUND. MAINTENANCE ACTION INVOLVED CSDR QXEA9700135Detector · defectivePDX- NR 1 BAGGAGE SMOKE DETECTOR WILL NOT TEST. REMOVED AND REPLACED NR 1 SMOKE DETECTOR. OPERATIONAL CHECK GOOD, AIRCRAFT RETURNED TO SERVICE.SDR IXKA9700022Smoke Detector · inopFORWARD LAVATORY SMOKE DETECTOR INOP. REMOVED AND REPLACED FORWARD LAVATORY SMOKE DETECTOR PER MM 26-18-00. (M)SDR UPS97422605Smoke Detector · defectiveINSPECTION TYPE-N/A, DURING CRUISE THE AFT CARGO FIRE LOWER LIGHT CAME ON INTERMITTENTLY FOR ABOUT A 5 MIN PERIOD OF TIME IT DID NOT COME ON AGAIN UNTIL OUR DESCENT INTO KIX AND WAS INTERMITTENT AGAIN. *S/D* REPLACED 4 SMOKE DETECTORS, OPS GOOD M128482 CLEARSDR IXKA9700016Battery · dischargedAFT RIGHT LAVATORY SMOKE DETECTOR ALARM SOUNDS. REPLACED BOTH BATTERIES. TEST NORMAL AS PER MM 26-18-00. (M)SDR 97UAL900286Smoke Detector · malfunctionedSMOKE ALARM - DETECTOR DID NOT ACTIVATE WITH FIRE AND SMOKE IN GARBAGE BIN AT 5L LAVATORY. SUPPLEMENTAL DATA UPDATE SMOKE DETECTOR MAY OR MAY NOT ACTIVATE DEPENDENT ON THE SEVERITY OF THE SMOKE. FIRE EXTINGUISHER DID NOT ACTIVATE WHICH INDICATES HEAT FACTOR WASDR RAIA970414Smoke Detector · failedRIC - FLT 7665 - ON FINAL AND AFTER LANDING, POD SMOKE ILLUMINATED INTERMITTENTLY THEN CONTINUOUSLY. RESCUE PERSONEL CONSULTED AND NO ACTION WAS REQUIRED. INDICATION WAS ERRONEOUS. MAINTENANCE REPLACED POD SMOKE DETECTOR. (M)SDR WWMA9700053Smoke Detector · defectiveTHE CARGO SMOKE LIGHT ILLUMINATED, CARGO FIRE BOTTLE NR 1 WAS FIRED. MAINTENANCE REPLACED BOTH FORWARD AND AFT CARGO SMOKE DETECTORS AND THE NR 1 FIRE BOTTLE.SDR SCNA97084Smoke Det Lamp · failedPOSITION 2 CARGO SMOKE DETECTOR DID NOT TEST. RELAMPED SMOKE DETECTOR AND FUNCTIONALLY TESTED WITH NO DISCREPANCIES NOTED.SDR SIMA9700971Smoke Detector · malfunctionedIND - FLT 4188 - FORWARD SMOKE DETECTOR WARNING LIGHT ILLUMINATED IN FLIGHT, CREW INSPECTED THE CARGO COMPARTMENT AND NO SMOKE OR FIRE WAS NOTED. FLIGHT CONTINUED TO ORD. MAINTENANCE REMOVED AND REPLACED FORWARD SMOKE DETECTOR. OPS CHECK WAS GOOD. AIRCRAFT
Back to JASC 2611