SDR YENA2022122101279Fire Bottle · dischargedFLT#187, BOS-LAX. (ETOPS) 'ON PREFLIGHT INSP - APU DISCHARGE LIGHT ILLUMINATED ( APU AGENT DISCH LIGHT - APU NOT USED ); SLAVED IN ENG/APU FIRE PANEL IAW TSM 26-22-00, NO HELP. CHANGED RELAY46LP ALSO IAW WITH THE SAME TSM, BUT NO HELP. SUSPECTED FIRE BOTTLE PRSDR SWIA202266590None · failedAPU FIREX BOTTLE TEST CAUSES EMERGENCY APU SHUTDOWN WITH CODE 227 ON APU ECU (FILED CLOSED) REMOVED AND REPLACED PBA SWITCH FOR APU FIRE IN REFERENCE TO CRJ200 ESPM 20-24-00. NO FIX. REMOVED AND REPLACED FIRE DETECTION PANEL IN REFERENCE TO CRJ200 AMM 26SDR YENA2022082600820Fire Bottle · failedFLT#28, MCO-EWR. 'DUE TO T/C A320-26-2300-710-003 FIRE BOTTLE REPLACEMENT REQUIRED; REMOVED AND REPLACED AFT FIRE CARGO BOTTLE IAW AMM 26-23-42 OPS AND LEAK CHECKS GOOD. OK FOR SERVICE.'SDR SWAA2022072532038Fire Bottle · lowFLIGHT DECK FIRE EXTINGUISHER SHOW LOW PRESSURE / [01] R/R'D F/D HALON FIRE EXTINGUISHER PER AMM 26-26-01.SDR SWAA2022072532023Handle · brokenCOCKPIT FIRE EXTINGUISHER HANDLE BROKEN. / [01] REPLACED FIRE EXTINGUISHER PER AMM 26-26-01.SDR QXEA2022061300221Fire Detector · inoperativeFL250, MASTER WARNING, CHECK FIRE DETECT. E/A CHECKLIST TO AFT BAGGAGE FWD AND AFT FIRE BOTTLES LOW. RETURNED TO FIELD LANDING UNEVENTFUL. NO FIRE. REPLACED THE LOW-RATE FIRE-EXTINGUISHER BOTTLE AND RE-INSTALLATION OF HIGH-RATE FIRE-EXTINGUISHER BOTTLE. OPS CHSDR UIEA2022041900321Squib · noneAPU SQUIB P/N 30903856 S/N 01189 DUE FOR TIME CHANGE .(<P>REMOVED & REPLACED APU SQUIB PER B767-300 AMM 26-22-02.</P> / <P>SQUIB TEST PASSED . NEW DUE DATE 31 OCT 29</P>)SDR SWAA2022030378658Extinguisher · brokenCOCKPIT FIRE EXT HAS BROKEN HANDLE / [01] REMOVED AND REPLACED FIRE EXT PER SIPSDR SWAA2022020467176Extinguisher · failedWATER FIRE EXTINGUISHER MISSING CO2 CARTRIDGE / REPLACED WATER FIRE EXTINGUISHER PER AMM 26-26-02.SDR AALA202112271543Extinguisher · dischargedAIRCRAFT WAS NOT GROUNDED: FORWARD EMERGENCY COMPARTMENT HALON FIRE EXTINGUISHER BEGAN DISCHARGING ON ITS OWN DURING FLIGHT REMOVED AND PUT IN GALLEY CART. REPLACED PORTABLE HALON EXTINGUISHER PER AMM 26-26-01.SDR CALA2021072801204Pin · brokenFLIGHT DECK FIRE EXT RETAINING PIN SAFETY SEAL IS BROKEN. REPLACED SEAL.SDR SWAA2021040761414Fire Bottle · leakingCOCKPIT HALON FIRE EXTINGUISHER IS LEAKING AT FL370 / INSPECTED COCKPIT HALON FIRE EXTINGUISHER FOUND IT TO BE ONLY LEAKING GAS R/R COCKPIT FIRE EXTINGUISHER PER S IP THEN PERFORMED AMM TASK 05-51-95 FOR CLEANING AFTER DRY CHEMICAL FIRE EXTINGUISHER USESDR UIEA2020110202343Fire Bottle · dischargedAPU FIRE BOTTLE NR 1 DISCHARGED. TRANSFER TO MDDR NR 137012 IAW DDG NR 26-22-01-01, CAT C, DUE DATE 10NOV2020. ST 2248Z 04 NOV 20-BWI. REMOVED AND REPLACED NR 1 APU BOTTLE AND PERFORMED OPERATIONS CHECK, OPERATIONS CHECK GOOD. ALL WORK DONE IN ACCORDANCE WSDR UIEA2020040100611Fire Bottle · leakingUPPER DECK WATER FIRE EXTINGUISHER LEAKING.(<P>REMOVED AND REPLACED UPPER DECK WATER FIRE EXTINGUISHER PER AMM 26-26-02</P>)SDR MASA2019101412090Extinguisher · low pressureAFT PORTABLE FIRE EXT LOW PRESSURE. REPLACED FIRE EXT.SDR UIEA2019090305434Fire Bottle · defectiveFWD CABIN A ZONE FIRE EXTINGUISHING QTY GAUGE ERRATIC, DAILY CHECK. REMOVED & REPLACED FIRE EXTINGUISHER IAW AMM 26-24-00.SDR CA190719010Extinguisher · leaking(CAN) WHILE IN FLIGHT, CABIN PORTABLE FIRE EXTINGUISHER LOCATED BEHIND LAST ROW OF SEAT ON LH SIDE STARTED LEAKING EXTINGUISHING AGENT (HALON 1211). PLEASE NOTE THE PHOTO WHICH SHOWS THE O RING BETWEEN THE CYLINDER AND THE EXTINGUISHING HEAD/NOZZLE ASSY EXPOSESDR AALA201905279005Fire Bottle · faultyAIRCRAFT WAS NOT GROUNDED: AFT FIRE BOTTLE NEEDED TO BE REPLACED. MAINTENANCE REPLACED FIRE BOTTLE PER AMM 26-20-00.SDR AALA201905229002Fire Bottle · low pressureAIRCRAFT WAS GROUNDED: L54 LAVATORY FIRE BOTTLE LOW. MAINTENANCE REPLACED FIRE BOTTLE PER AMM 26-25-41.SDR FDEA201905071014Line · damagedMDIS 910 26-22 9839 07MAY19 VIE OPEN U LOGPAGES:3025198 RAMP REPORTED BY INBOUND HAZCAN LINES IN MDC BENT AND RIPPED OFF. UPDT 07MAY19 19:08 VIE DG FIRE EXTINGUSHERS DEFERRED PER MEL 26-26-01-03 AND COMPLIED WITH EA F-2622-T0346866 PART 1 DAMSDR FDEA2019042200873Line · dentedWORKING F.E.A. 6-2622-F0346303 PT.1 FOUND #3 HAZ CAN LINE CHAFFED AND DENTED AT FWD R/T QD COUPLING. REMOVED AND REPLACED BROKEN #1 HAZ CAN LINE REF AMM26-28-00-04-0. PART CHANGED HAZ TUBE ASSY.SDR FDEA2019042200872Line · brokenWORKING F.E.A. 6-2622-F0346303 PT.1 FOUND #1 HAZ CAN LINE BROKEN AT FWD R/T QD COUPLING.SDR UIEA2019013103073Extinguisher · abnormalSMOKE BARRIER RH SIDE HALON FIRE EXTINGUISHER FAILS WEIGHT TEST. THERE IS NO WEIGHT TEST TAG FROM THE PREVIOUS TEST.(<P>WEIGHED SMOKE BARRIER HALON FIRE EXTINGUISHER WITH SCALE ASR-382 (DUE DAT 26JAN19) I.A.W. AMM 26-26-02-216-012-001. EXTINGUISHER WEIGHT 3.81SDR UIEA2019013103076Extinguisher · abnormalFLIGHT DECK HALON FIRE EXTINGUISHER FAILED WEIGHT TEST. PREVIOUS WEIGHT WAS 3.6 LBS AND NOW WEIGHS 3.5 LBS. THE PREVIOUS WEIGHT TEST TAG DATES ARE ILLEGIBLE. (<P>WEIGHED FLIGHT DECK FIRE EXTINGUISHER WITH SCALE ASR-348 (DUE DATE: 26JAN19), WEIGHT WITHIN LIMITSSDR QXEA2018100100355Tube · twistedFWD BAGGAGE PIT HR FIRE BOTTLE OUTLET TUBE TWISTED. REMOVED AND REPLACED TUBE REF. AMM 26-22-03-000-8010 AND 26-22-03-400-801.SDR DALA201808205134Extinguisher · leakingDURING A SERVICE CHECK, FOUND FWD WATER EXTINGUISHER WAS LEAKING. REPLACED FWD PORTABLE WATER FIRE EXTINGUISHER IAW AMM 26-20. OK FOR SERVICE.SDR RAIA2018052970002Extinguisher · leakingAFT PORTABLE FIRE EXTINGUISHER LEAKING. R & R THE PORTABLE FIRE EXTINGUISHER.SDR AALA20180331001Extinguisher · leakingCOCKPIT FIRE EXTINGUISHER STARTED TO SLOWLY DISCHARGE ON ITS OWN. REMOVED THE EXTINGUISHER FROM THE FLIGHT DECK. REPLACED THE FIRE EXTINGUISHER IAW AMM 26-26-01.SDR DALA2018032101819Fire Bottle · unserviceableOUT OF LIMITS WEIGHT ON AFT/RT LAVATORY FIRE EXTINGUISHER CONTAINER. EXTINGUISHER ASSY WAS REMOVED AND A SERVICEABLE EXTINGUISHER ASSY WAS INSTALLED PER AMM 26-25-01.SDR REXA2017120801230Extinguisher · low pressure1 FWD F.A FIRE EXTINGSHR NOT SHOWING IN THE GREEN AREA
INSTALLED NEW FIRE EXT IAW AMM 25-60-00. OPS CHECK GOOD A/C OK FOR SVCSDR IF1A2018020200001Extinguisher · leakingDURING A PREFLIGHT INSPECTION, FOUND THE PORTABLE HALON FIRE EXTINGUISHER LIGHT IN WEIGHT. WEIGHED THE EXTINGUISHER AND FOUND IT TO BE LESS THEN A POUND, SHOULD BE 3 + POUNDS. THIS WAS THE THIRD EXTINGUISHER THAT WAS FOUND WITH NO OR LITTLE CHARGE LEFT.SDR REXA2017113001212Tube · bentFOUND FWD LAVATORY EXTINGUISHER DISCHARGE TUBES WERE BENT AND DAMAGED. REMOVED AND REPLACED THE FWD LAVATORY FIRE EXTINGUISHER IAW AMM 26-26-01.SDR DALA2017111308062Extinguisher · low pressureCOCKPIT FIRE EXTINGUISHER OUT OF GREEN RANGE. SWAPPED THE FLIGHT DECK BOTTLE WITH AFT CABIN HALON BOTTLE. REMOVED AND REPLACED THE AFT HALON FIRE EXTINGUISHER.SDR REXA2017101101091Extinguisher · low pressureCOCKPIT FIRE EXTINGUISHER LOW. INSTALLED A NEW FIRE EXTINGUISHER IN THE COCKPIT IAW AMM 26-23-01. ACFT OK FOR SERVICE.SDR REXA2017100201072Extinguisher · leakingAFT CABIN WATER FIRE BOTTLE HANDLE DAMAGED AND WAS FOUND TO BE LEAKING FROM BOTTLE. REMOVED AND REPLACED AFT CABIN FIRE BOTTLE IAW AMM 26-23-01-000-801A23, STEP 4A, AND 26-23-01-400-801 A23 STEP 4,A.SDR REXA2017081800898Fire Bottle · lowLAVATORY FIRE BOTTLE NOT SHOWING GREEN. REMOVED AND REPLACED THE LAVATORY FIRE EXTINGUISHER IAW AMM 26-26-01.SDR REXA2017081600888Fire Bottle · leakingDURING EE-900 FOUND AFT FIRE EXTINGUISHER LEAKING. R&R AFT FIRE EXTINGUISHER PER EE-900 JOB CARD.SDR REXA2017072600810Fire Bottle · dischargedFOUND FLT DECK PORTABLE FIRE BOTTLE SAFETY PIN MISSING AND DISCHARGED. REMOVED AND REPLACED FLT DECK PORTABLE FIRE EXTINGUISHER IAW AMM 26-23-01SDR REXA2017071500795Extinguisher · damagedCOCKPIT PORTABLE FIRE EXTINGUISHER DISCHARGE HOSE BENT CLOSED. REMOVED AND REPLACED PORTABLE FIRE EXTINGUISHER AS PER JOB CARD 26-900-700 P/N ON/OFF - 100-9750, S/N OFF - W-950108, S/N ON - W-950665SDR P5CA2017063000215Extinguisher · leakingUPPER DECK WATER FIRE EXTINGUISHER LEAKING. REMOVED AND REPLACED THE WATER FIRE EXTINGUISHER IAW AMM 26-26-02.SDR REXA2017051600607Safety Wire · brokenFIRE EXTINGUISHER BOTTLE SAFETY WIRE BROKEN. WATER FIRE EXTINGUISHER BOTTLE REMOVED AND REPLACED IAW AMM 26-23-01.SDR AALA201705109028Fire Bottle · leakingWHILE AT CRUISE FL350, THE FLT DECK HALON FIRE EXTINGUISHER SPRUNG AN UNCONTROLLABLE LEAK. THE FLIGHT CREW DONNED THEIR O2 MASKS. A JUMPSEAT PILOT REMOVED THE EXTINGUISHER FROM THE COCKPIT AND MOVED IT INTO THE FORWARD LAVATORY. THE LAVATORY REMAINED CLOSED UNSDR REXA2017040800486Lever · brokenWARDROBE CLOSET PORTABLE FIRE EXTINGUISHER BOTTLES DISCHARGE LEVER BROKEN. R & R THE PORTABLE FIRE EXTINGUISHER BOTTLE IAW AMM 26-23-01.SDR IPXA2017021614111Extinguisher · unsecureFIRE EXTINGUISHER BY THE RIGHT ENTRY DOOR WILL NOT STAY SECURED IN BRACKET. SECURED THE FIRE EXTINGUISHER TO THE BRACKET IAW 26-24-01-400-801.SDR P5CA2017012700051Extinguisher · corrodedLAVATORY FIRE EXTINGUISHER RUSTED AT THE SURFACE. REPLACED THE FIRE EXTINGUISHER IAW AMM TASK 20-11-00-910-802 REV 120.SDR REXA2017012000070Extinguisher · unserviceableHALON FIRE EXTINGUISHER MISSING DISCHARGE HOSE. REMOVED UNSERVICEABLE HALON FIRE EXTINGUISHER AND INSTALLED SERVICEABLE HALON FIRE EXTINGUISHER IAW JOB CARD 26-900-700 P/N ON/OFF: 100-9750 S/N: F002305C S/N OFF:000671CSDR AALA201701049003Fire Bottle · unsecureAIRCRAFT WAS GROUNDED: AT APPROXIMATELY 130 KNOTS TAKEOFF WAS ABORTED AFTER UNKNOWN " BANG" NOISE WAS HEARD. MAINTENANCE MADE A THOROUGH INSPECTION OF AIRCRAFT & ENGINES & LANDING GEAR. AFTER DEBRIEFING THE FLIGHT CREW DETERMINED THE UNKNOWN BANG WAS FROM UNSESDR FDEA201612114382Fire Bottle · low pressureHAZ CAN FIRE BOTTLE PRESS BELOW THE GREEN BAND. REMOVED AND REPLACED AFT HAZ CAN FIRE BOTTLE IN REF TO AMM 26-26-99-4. ACFT OK FOR SERVICE.SDR REXA2016112502329Extinguisher · low pressureCOCKPIT FIRE EXTINGUISHER BOTTLE LOW PRESSURE. REMOVED AND REPLACED COCKPIT FIRE EXTINGUISHER IN ACCORDANCE WITH AMM 26-23-01.SDR DALA2016092806922Fire Bottle · leakingWATER EXTINGUISHER LEAKING INTO 1ST CLASS CLOSET. R & R WATER EXTINGUISHER IAW AMM 26-20, SN ON: 12967, SN OFF: CRS140.