Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3300' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3300' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2022090502262Battery · noneDURING EMERGENCY BATTERY CAPACITY TEST; EPSU BATTERY (13WL) FAIL TEST ND NEED TO BE REPLACE. AS NOTED ON LTPR NR# 5001168102-0010 EPSU BATTERY (13WL) FAILED ON EMERGENCY LIGHTING BATTERY P/N ON: AD3214-31, S/N ON: 287722, QTY:1EA B/N ON:N842UA3135. CAPACITY TESDR CALA2022090502261Battery · noneDURING EMERGENCY BATTERY CAPACITY TEST; EPSU BATTERY (10WL) FAIL TEST AND NEED TO REPLACE. AS NOTED ON LTPR NR# 5001168079-0010 EPSU BATTERY (10WL) FAILED ON EMERGENCY LIGHTING BATTERY P/N ON:AD3214-31, S/N ON: 287719, QTY:1EA, B/N ON:N842UA3134. CAPACITY TESTSDR CALA2022090502260Battery · noneDURING EMERGENCY BATTERY CAPACITY TEST; EPSU BATTERY (12WL) FAIL TEST AND NEED TO BE REPLACE. AS NOTED ON LTPR NR# 5001168101-0010 EPSU BATTERY (12WL) FAILED ON EMERGENCY LIGHTING BATTERY 1EA. P/N ON: AD3214-31, S/N: ON:273394, QTY:1EA, B/N ON: N842UA3 CAPACITSDR QXEA2022090200284None · noneAFT RH EXIT IDENTIFIER SIGN INOP. REMOVED FROM SERVICE. REF W/O 322930, N/R-00001 AND N/R-00002 FOR WORK PERFORMED. REPLACED THE ELPU 4 BATTERY BOX /ELPU IAW E175 AMM 33-50-01-00/400-801-A AND C/W MCN E330033-01. OPS TEST GOOD. EMERGENCY EXIT LIGHT AT R2 DOOR SDR CALA2022090202249None · noneB777-25-3-7170 L3 DOOR M33400 EMER BATTERY PACK FOUND BATTERY "LOW" TRANSFER REF HXWO 1018086 AND ORIGINATED BY EMP V896975 L3 DOOR M33400 EMER BATTERY PACK AND POWER SUPPLY REPLACED AS PER AMM 33-51-06 AND OP TEST CARRIED OUT RESULT NORMAL AS PER AMM33-51-06 SDR CALA2022090202248Battery · noneB777-25-3-7170 L3 DOOR M33406 EMER BATTERY PACK FOUND BATTERY "LOW" TRANSFER REF HXWO 1015854 AND ORIGINATED BY EMP V896975 L3 DOOR M33406 EMER BATTERY PACK REPLACED AND OP TEST CARRIED OUT WITH NORMAL IAW AMM 33-51-06 WORK ACCOMPLISHED BY MECHANIC V896975 INSSDR CALA2022090202239None · noneB777-25-3-7170 L1 DOOR M33093 EMER BATTERY PACK FOUND BATTERY "LOW" TRANSFER REF HXWO 1018087 AND ORIGINATED BY EMP V896975 L1 DOOR M33093 EMER BATTERY PACK AND POWER SUPPLY REPLACED AS PER AMM33-51-06 AND OP TEST CARRIED OUT RESULT NORMAL AS PER AMM33-51-06 WSDR CALA2022090202238Battery · noneSUPPORT TASK - OVERHEAD ATTENDANT REST EMERGENCY LIGHT (M9073) FOUND INOP TRANSFER REF HXWO 1045546 AND ORIGINATED BY EMP V896965 OHAR EMER LT BATTERY REPLACED AND OP TEST RESULT NORMAL AS PER AMM 33-51-05 WORK ACCOMPLISHED BY MECHANIC V907894 INSPECTED BY V92SDR CALA2022083102227None · noneEMERGENCY LIGHTS AT RH OVERWING EXIT INOP REMOVED AND REPLACED EMERGENCY LIGHT POWER SUPPLY M1695 WITH BATTERY PACK IAW MM 33-51-06. OP CHECK GOOD.SDR WX0A2022091674244None · noneNRC: 9000-0008 RH AFT DOOR COUOUT EMERGENCY SIGN LENS BROKEN / RH AFT DOOR CUTOUT EMERGENCY SIGN LENS REPLACED IAW AMM 33-51-13-400-001-A"SDR I5EA2022082800002Power Supply · no testEMERGENCY LIGHT AT L/H OWEE INOP. REMOVE AND REPLACED POWER SUPPLY ASSY AT MODULE M1134 STA. 634L IAW B737-400 AMM 33-51-51. TEST GOOD.SDR CALA2022082902201Battery · noneEMERGENCY LIGHTS CAPACTIY CHECK NO GOOD ON BATTERIES M1674 AND M 1669 (REF AAR NR 99939054).SDR CALA2022082902198Charger · noneB767-33-3-7000 EMER LT POWER SUPPLY M734 INOP TRANSFER REF. NON ROUTINE HX WO 1032718 AND ORIGINATED BY EMP V920570 M734 EMER LT POWER SUPPLY CHARGER REPLACED & TESTED NORMAL AS PER AMM 33-51-07 WORK ACCOMPLISHED BY MECHANIC V920570 INSPECTED BY V928691SDR CALA2022082602177None · noneB777-33-3-7019 - DR L2 EMER PWR SUPPLY M33096 CHARGER TEST FAIL TRANSFER REFER NON-ROUTINE WO.933084 - AND ORIGINATED BY V898181 DR L2 M33096 EMER LT BATTERY CHARGER REPLACED AND TESTED NORMAL AS PER AMM 33-51-06 - WORK ACCOMPLISHED BY MECH V898181 AND INSPECTSDR CALA2022082602176None · noneB777-33-3-7019 DR L2 EMER PWR SUPPLY M33096 BATTERY CAPACITY CHECK FAIL - TRANSFER REFER NON-ROUTINE WO.933076 AND ORIGINATED BY EMP V898181 DR L2 M33096 EMER LIGHT BATTERY REPLACED AND TESTED NORMAL AS PER AMM 33-51-06 - WORK ACCOMPLISHED BY MECH V898181 AND SDR CALA2022082602175None · noneB777-33-3-7019 DR R3 EMER PWR SUPPLY M33404 BATTERY CAPACITY CHECK FAIL - TRANSFER REFER NON-ROUTINE WO.933072 AND ORIGINATED BY V898181 DR R3 M33404 EMER LIGHT BATTERY REPLACED AND TESTED NORMAL AS PER AMM 33-51-06 WORK ACCOMPLISHED BY MECH V898181 AND INSPECSDR QXEA2022082200275Power Supply · noneEMERGENCY LIGHTS AT MAIN CABIN DOOR AND AFT PASSENGER AND SERVICE DOORS AND ASSOICATED OVERHEAD LIGHTS FAIL THE 10 MINUTE TEST OF TASK CARD 335000Q02. REPLACED POWER SUPPLIES IAW AMM 33-51-00-802 AND 33-51-01-400-802. CHECKS GOOD.SDR QXEA2022081900271Battery · noneDURING MORNING MTX WALKAROUND, FOUND EMERGENCY LIGHT FAULT MSG. REMOVED FROM SERVICE. REMOVED AND REPACED BATTERY PACK ON ELPU2, REF AMM TASKS 33-50-01-000/400-802-A, OPS TEST GOOD, MSG NO LONGER NOTED. RETURNED TO SERVICE.SDR WX0A2022080574182Epsu · noneCA REPORTS AFT EMERGENCY LIGHTS STAY ON W/ SWITCH IN ARMED POSITION. / ACCOMPLISHED EPSU BITE TEST IAW AMM 33-51-00-710-001, TEST FAULTED SWITCH 4 WL, R + R SWITCH 4WL IAW ESPM 20-30-00, OPS CHECK FAILED FAULTED 11WL BAT AND 13WL BAT. R + R EPSU BATTERIES 11WLSDR CALA2022072701899Harness · chafedEPL WIRING BETWEEN SEAT ROWS 34 & 35 ABC IS DAMAGED CAUSING THE AFT CABIN EMERGENCY LIGHTS TO APPEAR WEAK. (REF. N/R 000149). SUPPORT TASK NSA EMX N/R 00153. REPAIRED DAMAGED EEPL SEAT TO SEAT CABLE WITH 2 EA SPLICES AT REPORT, FORM 46-0024, ENTERED BY UAL INSSDR N6WA2022072601Battery Pack · inoperativeEMERGENCY LIGHTS INOP. ALLOWED EMERGENCY LIGHT BATTERIES TO CHARGE AND PERFROMED OPS CHECK OF EMERGENCY LIGHT SYSTEM IAW CRJ 550 AMM 33-51-00. OPC CHECK GOOD AT THIS TIME.SDR 2022FA0000353None · noneCREW REPORTED ON PREFLIGHT, THAT THE RIGHT WING NAV LIGHT IS NOT WORKING. CREW MADE A LOGBOOK ENTRY. AMT TRANSFERRED THE ENTRY TO MAINTENIX AND DEFERRED THE RIGHT WING NAV LIGHT T3F18E000FN37. HE DID NOT CLOSE THE WORK PACKAGE. THE WORK PACKAGE WAS READY TO CSDR WX0A2022071374154None · noneBAT/ EPSU 11WL EMER LIGHT FAILED BITE TEST / REMOVED, CLEANED, AND REINSTALLED CONNECTOR OF EPSU 11WL W/REF TO AMM 33-51-38-400-00-A AND ESPM 20-44-10. BITE TEST GOOD, NO DISCREPANCIES NOTED."SDR WX0A2022071374153Epsu · noneALL 4 BATTERIES FAIL ON SHIP CAP CHECK. / REF AMM 33-51-38 PB 401, REMOVE & REPLACED ALL 4 EMERGENCY LIGHT BATTERIES. BITE & OPS CHECKS GOOD."SDR 2022F00287None · abnormalL1 EMERG EXIT LITE INOPSDR UIEA2022062100627None · noneM/D EMER LT - OVER DOOR L5735 FOUND DIM.(<P>M/D EMER LT - OVER DOOR L5735 LAMP REPLACED, LENS INSTALLED AND OPERATION TEST AND SYSTEM TEST CARRIED OUT RESULT 'NORMAL' IAW AMM 33-51-07 AND 33-51-00.</P>)SDR WX0A2022071174147Epsu · noneEMERGENCY POWER SUPPLY UNITS AT FIN 10WL, 11WL, 12WL AND 13WL REQUIRE REPLACEMENT. / REMOVED AND REPLACED EMERGENCY POWER SUPPLY UNITS AT FIN 10WL, 11WL, 12WL AND 13WL. OPS CHECK AND BITE CHECK GOOD IAW AMM 33-51-38"SDR WX0A2022071174150Epsu · noneEPSU BATTERY CAP TEST FAILED. / R&R EMERGENCY POWER SUPPLY UNITS (10WL) AND (13WL) IAW AMM 33-51-38 PB401. BITE CHECK GOOD EPSU BATTERY CAP TEST IN PROGRESS."SDR WX0A2022071174149Epsu · none10WL, 11WL AND 12WL FAILED ESPU CHECK . / REMOVED AND REPLACED BATTERIES ON ESPU'S I.A.W MM 33-51-38-000-002-A AND MM 33-51-38-400-002-A. BITE CHECKED GOOD I.A.W MM 33-51-00-710-001-A."SDR WX0A2022071174146Epsu · noneDURING THE BATTERY CAPACITY TEST IT SHOWED 10WL, 11WL, 13WL FAILED. / REMOVED AND REPLACED 10WL, 11WL, 13WL BATTERIES WITH INSPECTED BATTERIES IAW AMM 33-51-38. OPS CHECK GOOD. NO OTHER DEFECTS NOTED AT THIS TIME."SDR WX0A2022070874145None · noneFA REPORTS ""L1 EXIT SIGN IS NOT LIGHTED PROPERLY"". THIS IS THE SIGN JUST ABOVE THE L1 DOOR / RELAMPED EMERGENCY EXIT SIGN OVER L1 DOOR IAW AMM 33-51-16 PB 401 OPS CHECK GOOD."SDR WX0A2022070874143Epsu · noneDURING WEEKLY CHECK FOUND EPSU BATTERY AT L/H O/W EXIT (11WL) FAULTING. / REPLACED EPSU BATTERY AT L/H O/W EXIT (11WL) REF AMM 33-51-38Ï¿½PBÏ¿½401. BITE TEST GOOD."SDR WX0A2022070674138None · noneWHILE PREFORMING TASK 33-51-00-710-001-A (OPERATIONAL CHECK OF EMERGENCY POWER SUPPLY UNITS BY BITE-CHECK) RECIVED EPSU (11WL) FAULT MESSAGE DURRING OPS CHECK. / REMOVED AND REPLACED FWD AND AFT OVERWING EMERGENCY LIGHTS IAW AMM 33-51-15 OP CHECK GOOD AT THISSDR WX0A2022070874141Epsu · noneWHILE PERFORMING EPSU CHECK ON MCDU, PER WEEKLY CHECK, FOUND AFT EPSU (13WL) BATTERY FAILED. / REMOVED AND REPLACED AFT EPSU (13WL) BATTERY REF AMM 33-51-38Ï¿½PBÏ¿½401. OPS CHECK GOOD."SDR WX0A2022070674140Epsu · noneMID L/H (11WL) EMERGENCY LIGHT BATTERY PACK DISPLAYS FAILED ON EMERGENCY LIGHT TEST / REMOVED AND REPLACED MID L/H (11WL) EMERGENCY LIGHT BATTERY PACK PER AMM 33-51-38-000-002-A AND 33-51-38-400-002-A OPS CHECK GOOD."SDR WX0A2022070574137Epsu · noneEMERGENCY LIGHT TEST GAVE MESSAGE ""ATA 335100 BAT/ESPU (10WL) FWD L / RAR BATTERY FOR ESPU 10WL IAW AMM 33-51-38 PB 401 CONF 00 OPS CHK GOOD."SDR WX0A2022070674139None · noneCABIN EMERGENCY CEILING LIGHT 205WL, 206WL, 207WL REQUIRE REMOVAL / REMOVED CABIN EMERGENCY CEILING LIGHT 205WL, 206WL, 207WL IAW AMM 33-51-11"SDR WX0A2022070174133Epsu · noneDURING BATTERY CHECK MCDU DISPLAYS 11-WL BATTERY FAIL. / REPLACED EMERGENCY LIGHT BATTERY (11WL) PER AMM 33-51-38 P/B 401. PERFORMED OPS TEST PER WORK CARD."SDR WX0A2022070174134None · noneR2 EXIT LIGHT INOP. / FOUND BROKEN WIRE AT EMERGENCY EXIT SIGN (44WL) AND REPAIRED IT IAW ESPM - AIRBUS 20-43-00 AND AMM 33-51-16 PB 401. OPS CHECK GOOD."SDR WX0A2022062974129Epsu · nonePERFORMED EMERGENCY LIGHT TEST AND FOUND RIGHT EPSU BATT FAULTING / REMOVED AND REPLACED RIGHT EPSU BATT. OPS CHECKS GOOD IAW AMM 33-51-38 PB 401"SDR WX0A2022062774128Epsu · noneEMERGENCY POWER SUPPLY UNIT 11WL FAILED CAPACITY TEST. / REMOVED AND REPLACED EMERGENCY POWER SUPPLY UNIT BATTERY 11WL IAW AMM 33-51-38 PB 401 CONF 00."SDR WX0A2022062774127Epsu · noneEMERGENCY POWER SUPPLY UNIT 13WL FAILED CAPACITY TEST. / EMERGENCY POWER SUPPLY UNIT 13WL REMOVED AND REPLACED IAW AMM'S 33-51-38-000-001-A AND 33-51-38-400-001-A. REFER NR00963807 FOR OPERATIONAL CHECK."SDR WX0A2022062774126Epsu · noneDURING WEEKLY CHECK L/H O/W EXIT EPSU FAILED BITE TEST. / R+R'D BATTERY OF EPSU AND EPSU (11WL) PER AMM 33-51-38 PB 401 CONF 00. OPS CHECKED GOOD."SDR CALA2022060601444Epsu · failedEMERGENCY POWER SUPPLY (M1675) FAIL. (REF AAR RFD NR 99936092).SDR YENA2022092200946Epsu · failedDURING HEAVY MAINTENANCE, SECONDARY FINDINGS DON'T PASS OPERATIONAL TEST EPSU-EMERGENCY POWER SUPPLY UNIT FWD LH, EMER RH, EMER LH, AFT LH IN PASSENGER CABIN REF TO JOB CARD A320-52-10-00-200-002-832; PERFORMED TROUBLESHOOTING OF THE OPERATIONAL TEST EPSU IN TSDR YENA2022092200945None · failedDURING HEAVY MAINTENANCE, SECONDARY FINDINGS DON'T PASS OPERATIONAL TEST EPSU-EMERGENCY POWER SUPPLY UNIT FWD LH, EMER RH, EMER LH, AFT LH IN PASSENGER CABIN REF TO JOB CARD A320-52-10-00-200-002-832; PERFORMED TROUBLESHOOTING OF THE OPERATIONAL TEST EPSU IN TSDR YENA2022092200944None · failedDURING HEAVY MAINTENANCE, SECONDARY FINDINGS DON'T PASS OPERATIONAL TEST EPSU-EMERGENCY POWER SUPPLY UNIT FWD LH, EMER RH, EMER LH, AFT LH IN PASSENGER CABIN REF TO JOB CARD A320-52-10-00-200-002-832; PERFORMED TROUBLESHOOTING OF THE OPERATIONAL TEST EPSU IN TSDR YENA2022092200943None · failedDURING HEAVY MAINTENANCE, SECONDARY FINDINGS DON'T PASS OPERATIONAL TEST EPSU-EMERGENCY POWER SUPPLY UNIT FWD LH, EMER RH, EMER LH, AFT LH IN PASSENGER CABIN REF TO JOB CARD A320-52-10-00-200-002-832; PERFORMED TROUBLESHOOTING OF THE OPERATIONAL TEST EPSU IN TSDR YENA2022092200942None · failedDURING HEAVY MAINTENANCE, SECONDARY FINDINGS DON'T PASS OPERATIONAL TEST EPSU-EMERGENCY POWER SUPPLY UNIT FWD LH, EMER RH, EMER LH, AFT LH IN PASSENGER CABIN REF TO JOB CARD A320-52-10-00-200-002-832; PERFORMED TROUBLESHOOTING OF THE OPERATIONAL TEST EPSU IN TSDR YENA2022092200941Epsu · failedDURING HEAVY MAINTENANCE, SECONDARY FINDINGS DON'T PASS OPERATIONAL TEST EPSU-EMERGENCY POWER SUPPLY UNIT FWD LH, EMER RH, EMER LH, AFT LH IN PASSENGER CABIN REF TO JOB CARD A320-52-10-00-200-002-832; PERFORMED TROUBLESHOOTING OF THE OPERATIONAL TEST EPSU IN T
Back to JASC 3300