JASC 3320
Service difficulty reports · 2,972
Reports filed under 3320 · Passenger Compartment Lighting, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2016031849988Light · inoperativeEMERGENCY BULLNOSE LIGHT INOPERATIVE AT ROW 5 DEF. RELAMPED IAW MM.SDR ASOA20160317013Lamp · arcedA BURNING PLASTIC ODOR REPORTED FROM THE GALLEY NEAR THE OVERHEAD LIGHT. MX R & R THE LIGHT BLUBS AT SEAT 1 A WITH OPS CHECK GOOD. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR R61A201603140198Light · out of adjustCREW REPORTED THAT THE MIDDLE BLUE RAINBOW LIGHT WAS INOPERATIVE. ADJUSTED F/A CALL INDICATOR IAW AMM AND OPS CHECKED GOOD.SDR HNAA2016031100075Ballast · smokeSMOKE FROM SIDEWALL AREA ABOVE OVERHEAD BIN NEAR ROW 1DF. R & R AFT LAMP HOLDER AND BALLAST ASSY FOR LIGHT. OPS CHECKED GOOD IAW MM 33-20-00 AND 33-21-02. OK FOR SERVICE. CLEARED MEL.SDR SIMA20160310005Control Module · faultyCABIN COVE LIGHTS WILL NOT TURN ON. FLIGHT ATTENDANT SMELLED SOMETHING. R & R WITH SERVICEABLE SIDEWALL LIGHT CONTROL MODULE IAW AMM 33 21 01. OPERATIONS CHECKED OK.SDR REXA2016030400348Light · malfunctionedEMERGENCY CALL SWITCH LIGHT NOT FLASHING WHEN EMER SWITCH LIGHT IS PUSHED IN AS REPORTED BY FLIGHT ATTENDANTS. PERFORMED RESET PROCEDURES. OPERATIONS CHECK OF EMER LIGHTS IAW AMM 33-51-00. ALL LIGHTS NORMAL OK FOR SERVICE.SDR IPXA2016030300316Lamp · inoperativeLAVATORY AUX MIRROR LIGHT INOPERATIVE. REPLACED THE LAMP IAW AMM33-51-21-401.SDR HNAA2016030300069Light · discoloredELECTRICAL ODOR IN COAT CLOSET. PERFORMED HIDDEN DAMAGE INSPECTION NO DEFECTS NOTED. CONTACTS ON WARDOBE LIGHT APPEAR SLIGHTLY DISCOLORED. DEACTIVATED IAW SP 33.1. CABIN INTERIOR NORMAL LIGHTING SYS.SDR AALA201603029008Ballast · defectiveAIRCRAFT WAS NOT GNDED. FLIGHT ATTENDANT REPORTED ODOR, INTERMITTENT, AROUND ROW 26, MAYBE ELECTRICALISH, TURNED CABIN FAN OFF, ODOR DISSIPATED & DID NOT RETURN. 2 HOURS LATER FLIGHT ATTENDANT SAID SMELL RETURNED BUT DISSIPATED AGAIN AFTER A MINOR TWO. PERFSDR CA160302010Ballast · failed(CAN) AFTER PUSH BACK, BOTH ENGINES STARTED, APU OFF, FA NOTICED ELECTRICAL BURNING SMELL, THEN SMOKE EMANING FROM CABIN ABOVE BINS 7, 8 AND 9, THICK WHITE SMOKE, A/C EVACUATED. FOUND CEILLING LIGHT BALLAST TO BE THE ROOT CAUSE. BALLAST REPLACED.SDR SIMA20160228002Ballast · overheatedSTRONG ELEC BURNING SMELL IN GALLEY & COCKPIT. FOUND GALLEY SERVICE WORK LIGHT BALLAST, FWD, OVERHEATING WHEN SWITCH IS ON. DEFERRED GALLEY WORK LIGHT IAW 25-30.SDR CALA2016021695111Socket · burnedELECTRICAL SMELL IN CABIN CONSISTENTLY AT LAVATORY AT 2L, NOTICED AT LAVATORY 3L & AROUND ROWS 25 - 27. ACCOMPLISHED AMM 05-51-50, TO STEP C T. FOUND A BURNED SOCKET ON THE MIRROR LIGHT FIXTURE AT DOOR 2L, ISOLATED LIGHT BALLAST FROM THE SOCKET. ALSO USED FSDR DXTA2016020506179Switch Panel · burnedWHILE TROUBLESHOOTING, CONFERENCE TABLE READING LIGHT, FOUND SWITCH & SWITCH PANEL BURNT. REMOVED READING LIGHT SWITCH CAPSULE & FOUND CAPSULE & PANEL SIDE BURNT. REMOVED SWITCH PANEL, PN SPS-F90-5093, SN 040100670 & INSTALLED A REPAIRED SWITCH PANEL, PN SPSSDR QXEA2016020200082Light · inoperativeINBOUND AT 16000 FT FA REPORTED A VERY LOCALIZED ELECTICAL ODOR IN VICINITY ROW 16DE. NO VISIBLE SMOKE, NO ABNORMAL INDICATIONS ANYWHERE ELSE IN ACFT. ODOR LASTED APPROXIMATELY 2 MIN AND DID NOT REPEAT. OPENED ROW 14 AND 15DE PSU PANEL DISCONNECTED READING LSDR CALA2016020395073Receptacle · burnedLAVATORY 3L BURNING SMELL. ACCOMPLISHED INSPECTIONS IAW MM 05-51-50. FOUND MIRROR LIGHT FWD LAMP RECEPTACLE BURNT & CAUSING ODOR. REMOVED LAMP, DISCONNECTED & SAFETIED BALLAST M004 CONNECTOR IAW STANDARD PRACTICES. COMPLIED WITH MEL.SDR RAIA201601310001Light · sparksF/A REPORTED SMOKE IN THE CABIN AT THE GATE. OBSERVED FLASHING AROUND OVERHEAD OF SEAT 6D.SDR CA160201002Power Supply · failed(CAN) CABIN CREW NOTED ELECTRICAL SMOKE EMANATING FROM THE PASSENGER SERVICE UNIT, PSU, AREA AT ROW 9AB DURING FLIGHT. FLIGHT CREW DECIDED TO RETURN TO BASE FOR MAINTENANCE PERSONNEL TO INSPECT THE ACFT. MAINTENANCE DISCOVERED ROOT CAUSE TO BE A READING LIGHSDR CALA2016012895060Light · inoperative3L AFT LAVATORY OVERHEAD TUBE SMOKED & WENT OUT, TUBE REMOVED. CREW INFO, SMOKE ODOR HAS GONE AFTER LIGHT TUBE REMOVED. LIGHT SOCKET CONDITION CHECKED OK.SDR AALA20160127004Light · defectiveCREW REPORTED BURNING SMELL & SMOKE COMING FROM RT AFT LAVATORY. MX FOUND SOURCE OF SMOKE TO BE LIGHT ASSEMBLY CAPSULE IN RT AFT LAVATORY. NO DAMAGE TO ACFT. CHECKED & DEFERRED LIGHT IAW MEL 332. OK FOR SERVICE. ACFT WAS NOT GNDED. REPLACED FLUORESCENT LSDR CALA2016012700072Lamp Socket · damagedREFERENCE LOG PAGE 8377435. SPARKS & SMOKE FROM MID-LAVATORY, FOUND WIRING CONNECTING TO A1 TERMINAL ON MID LAVATORY BALLAST DAMAGED FROM HEAT. R & R L1 LAMP SOCKET & WIRING GOING TO MID-LAVATORY BALLAST, RT 1 TERMINALS A1 & 1. REF IFM 25-40-02.SDR SWAA2016011848072Light · inoperativeDIVERSION & DECLARED EMER. FLIGHT ATTENDANTS & PAXS REPORTED THE SMELL OF SMOKE OR ELEC FIRE, MID CABIN CAPTAINS SIDE. FOUND INOPERATIVE CEILING LIGHT AT ROW 15DEF. R & R LIGHT IAW MM.SDR IPXA2016011797911Lamp · inoperativeLAVATORY EXT POWER LAMP INOPERATIVE. REPLACED THE LAMPED IAW MM 33-51-21.SDR DXTA2016010806158Light · inoperativeBURNING SMELL COMING FROM INSIDE PAX DOOR. STRONG ENOUGH TO BE SMELLED IN THE COCKPIT. SUSPECT BURNING SMELL IN PASSENGER DOOR WAS LOWER AFT STEP LIGHT HAVING BURNT OUT. BULB WAS REPLACED. RAN APU AND ENGINES WITH NO SMELL IN COCKPIT OR CABIN. POWER WAS OSDR IPXA2016010897504Lamp · inoperativeINSPECTION TYPE: PS1, LAVATORY MIRROR LIGHT INOPERATIVE. REPLACED THE LAMP IAW AMM 33-51-21.SDR AALA201601029001Light · blownAIRCRAFT WAS NOT GNDED. FLIGHT ATTENDANT REPORTED ELEC SMELL IN AREA OF CABIN AT 2D DOOR. TURNED ALL ELEC IN CABIN OFF, SMELL DISSIPATED. ACCOMPLISHED JC 26L00021001, FOUND CEILING LAMP AT 12R CRACKED & BLOWN. RELAMPED 12 CEILING BULB IAW AMM 33-21-11. OPSDR ASOA201512240611Control Module · shortedCREW REPORTED A BURNING ODOR IN FRONT CABIN NEAR MAIN CABIN DOOR. MAINTENANCE R & R CABIN LIGHT CONTROL MODULE WITH OPS CHECK GOOD. ACFT APPROVED FOR RETURN TO SERVICE.SDR CALA2015122494915Light · arcedON FINAL APPROACH LIGHT BURNING ODOR NOTED. SMOKE ALARM IN LAVATORY 2R WENT OFF, NO APPARENT FIRE. CAPTAIN STATES MID RT LAVATORY IS WHERE SMOKE DETECTOR ACTIVATED. INSPECTED LAVATORY WATER HEATER, LAVATORY ASSEMBLY, ASSEMBLY ELEC COMPONENTS FOR ANY SIGN OFSDR HNAA2015122100368Socket · burnedSTRONG ELECTRICAL ODOR COMING FROM THE WARDROBE CLOSET. NO VISUAL EVIDENCE. FOUND OVERHEAD, MOST FORWARD LT BULB SOCKET BURNED. PULLED AND COLLARD CIRCUIT BREAKERS SI, S2 AND R2. DEACTIVATED IAW SP 33.1 MEL.SDR 29EA2016F00037Circuit Board · burnedFOUND CIRCUIT BOARD BURNED AND SHORTED, CONNECTOR PLUG ALSO BURNED AND SHORTED.SDR AALA20151214001Ballast · faultyDURING CRUISE A FLIGHT ATTENDANT REPORTED STRONG ODOR OF SOMETHING HOT NEAR L1 DOOR. ODOR STOPPED AFTER UTILITY BUSS SWITCHES SELECTED OFF. R & R BALLAST M658 FWD DIRECT CEILING LIGHTS. OPERATIONAL CHECKED NORMAL, TEMPERATURE NORMAL AT DIM MODE IAW AMM 33-2SDR SIMA20151210001Ballast · defectiveVERY STRONG NOXIOUS ODOR COMING FROM AN AREA AROUND 10A. REPLACED CEILING LIGHT BALLAST AT SEAT 9A IAW AMM 33-21-05 & PSU PANEL AT 8 - 9A IAW AMM 25-22-04. OPERATIONS CHECKED GOOD.SDR MASA2015120312591Bulb · inoperativeFORWARD GALLEY LIGHT INOPERATIVE FOUND TO BE FAULTY LIGHT BULB. REMOVED AND REPLACED THE BULB & OPS CHECKED GOODSDR SWAA2015113046478Light · odorRIGHT SIDE OVERHEAD READING LIGHT FAINT HOT ELEC SMELL AT ROW 21. FOUND PLASTIC LENS TOUCHING BULB. RELAMPED PER MM.SDR ASOA2015111714063Lamp · burned outGALLEY LOWER AFT EXIT, COURTESY LIGHT HAVE 2 LIGHT BULBS BURNED. RELAMPED GALLEY AFT EXIT SIGN IAW GMM 3-8, OPS CHECKED GOOD.SDR IPXA2015110795552Bulb · inoperativeINSPECTION TYPE: ASE, LAV AUXILIARY MIRROR LIGHT INOPERATIVE RELAMPED, REF AMM 33-51-21-401.SDR IPXA2015110695537Lamp · inoperativeINSPECTION TYPE: PS, LAV AUX MIRROR LIGHT INOPERATIVE. REPLACED THE LAMP IAW AMM 33-51-21-401.SDR AALA201511039005Ballast · defectiveFLIGHT ATTENDANT COMPLAINED OF A SMELL OF BURNING RUBBER AROUND THE AFT LAVATORIES. R & R CEILING LIGHT BALLAST AT 22 DEF IAW AMM 33-21-11. OPERATIONS CHECKED GOOD.SDR ASOA20151028055Light · arcedCREW REPORTED AN ACRID BURNING ODOR OBSERVED AROUND ROW 10A. MAINTENANCE R & R PASSENGER CABIN LIGHT ASSY AT SEAT 10A WITH OPS CHECK GOOD. ACFT APPROVED FOR RETURN TO SERVICE.SDR CA151029019Light · odor(CAN) DURING BOARDING AN F/A NOTED A STRONG ELECTRICAL ODOR MID CABIN, MCC WAS INFORMED AND MAINTENANCE FOUND CEILING LIGHT FLICKERING. THE ASSY WAS REPLACED IAW AMM 33-20-00 AND OPS TESTED SERVICEABLE. NO OTHERS ABNORMAL INDICATIONS FOR ANY LIGHTS, IFE, OR SDR CALA2015102794712Ballast · burnedELECTRICAL ODOR REPORTED IN CABIN, LAST 20 MINUTES OF FLIGHT. AFT CABIN RT SIDE NEAR ROW 25 - 28. CABIN CREW REPORT NO VISIBLE SMOKE, JUST ELEC ODOR. WHOLE AREA SURROUNDING ROWS 25 - 28 RT SIDE INSPECTED. FOUND ONE CEILING LT BALLAST UNIT WITH INTERNAL PARSDR RAIA201510220001Socket · burnedBURNING ODOR IN CABIN. FOUND BURNED LIGHT SOCKET AT ROW 17 AND 18A. DEACTIVATED BULB AND REMOVED CONNECTOR.SDR DALA2015101506165Bulb · odorON DESCENT, AROUND 12,000 FT INTO DESTINATION, A SMOKE ODOR WAS NOTED AROUND SEAT ROWS 13-14. THE COCKPIT CREW DECARED AN EMERGENCY AND FOLLOWED THE SMOKE/FUMES CHECKLIST. THE ODOR CLEARED AND THE ACFT LANDED UNEVENTFULLY WITH NO FURTHER ISSUE. THE ISSUE WASSDR SWAA2015101344844Transformer · inoperativeDECLARED EMER, FLIGHT ATTENDANT'S NOTIFIED COCKPIT OF SMOKE IN FWD GALLEY. HAD FLIGHT ATTENDANT'S PULL CB IN GALLEY IAW OCH. ALSO TURNED OFF GALLEY POWER SWITCH IN COCKPIT. SOME SMOKE, CONTINUED SUBSIDED JUST BEFORE EMER LANDING. FOUND FWD GALLEY WORK LIGHSDR AALA20151012003Panel · inoperativeFLIGHT CREW GND CHECK MIC ITEM 31225556. EVAC SWITCH AT 4L, SWITCH WILL NOT ENGAGE & HORN INOPERATIVE. L4 DOOR ATTENDANT PANEL ASSEMBLY REPLACED. INSTALLATION TEST FOUND NORMAL & EMER EVACUATION SIGNAL SYS OPERATIONAL TEST FOUND NORMAL IAW AMM 33-22-06 & AMSDR ASOA2015100913877Lamp · odorELECTRICAL ODOR IN FLIGHT. F/A REPORTS SIDEWALL LIGHTS ASSOCIATED WITH ODOR, SOMEWHERE AROUND ROW 13B, CABIN INTERIOR LIGHTS: ACFT WITH FLUORESCENT LIGHTS. RELAMPED SIDEWALL LIGHTS AT 12AB IAW AMM 33-21-07. OPS CHECK GOOD. NO BURNING ODOR. DMIL CLEARED PLASDR RAIA201510050003Light · odorBURNING ODOR AT ROW 9 DURING PREFLIGHT. MAINTENANCE INSPECTED AND REMOVED LIGHT ASSY, DISCONNECTED LIGHT RECEPTACLE AND STOWED CONNECTOR.SDR SWAA2015100144433Light · defectiveAIR TURN BACK, AFTER TAKEOFF BURNING RUBBER SMELL IN AFT CABIN & COCKPIT. R & R LIGHT ASSEMBLY IAW AMM.SDR CA150929003Cover · damaged(CAN) ON DESCENT I/C REPORTED AN ELECTRICAL BURNING ODOR IN BACK GALLEY, THAT THAT DISSIPATED AFTER 15 MINUTES AND THEN RETURNED AFTER LANDING AND MOC ADVISED. AFT LAV DOME LIGHT FOUND LOOSE TERMINAL TOUCHING PLASTIC ISOLATION COVER MELTED PLASTIC CAUSING ELESDR A6WA201543088Ballast · inoperativeFLIGHT 3949 ELEC ODOR COMING FROM OVERHEAD AT APPROX ROW 2 LT SIDE OF ACFT. TROUBLESHOT & FOUND SIDEWALL LIGHTS FOR BALLAST INOPERATIVE.SDR SAJF20151014018Ballast · inoperativeZONE A CEILING LIGHTS INOPERATIVE. FOUND P414 H17 CB POPPED OUT. PFM WIRING CHECKED & FOUND SEAT 3A CEILING LIGHT BALLAST M8468, PLUG & WIRING DAMAGED. AFFECTED BALLAST M8468 DAMAGED PLUG & WIRES HAS INSOLATED. THE P414 H17 CB RESET NORMAL, ZONE AN AREA CE
Back to JASC 3320