JASC 3350
Service difficulty reports · 225,886
Reports filed under 3350 · Emergency Lighting, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3350' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3350' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2019070234426Cover · missingCEILING EXIT SIGN AT OVERWING EXIT ROW MISSING. REINSTALLED COVER PER AMM.SDR SWAA2019070234420Charger · inoperativeR2 DOOR LOWER EMERGENCY LIGHT ASSEMBLY INOP. R&R CHARGER PACK IAW AMM.SDR AALA201907019036Battery · dischargedAIRCRAFT WAS NOT GROUNDED: L2 DOOR EMERGENCY FLASHLIGHT INOPERABLE, NO BLINKING LED. MAINTENANCE REPLACED L2 DOOR EMERGENCY FLASHLIGHT BATTERY PER AMM 25-60-00.SDR AALA201907019024Light · inoperativeAIRCRAFT WAS NOT GROUNDED: EMERGENCY LIGHT ABOVE SEAT 4H INOPERABLE. MAINTENANCE REPLACED EMERGENCY LIGHT PER AMM 33-50-00.SDR DALA2019070103960Charger · inoperativeDURING SERVICE CHECK FOUND EMERGENCY LIGHTS INOPERATIVE 13FG TO 20FG IN SEAT. REPLACED CHARGER. SYSTEM OPERATION IS NORMA.SDR DALA2019062903958Lens · missingEXIT SIGN AT THE FRONT OF FIRST CLASS IS MISSING. MAINTENANCE SECURED THE LENS. OKAY FOR SERVICE. (LP #5502216)SDR ASOA201906294039Battery Pack · dischargedIAH - FLIGHT 4291, DURING MAINTENANCE INSPECTION THE FLOOR PROXIMITY STRIP LIGHT FORWARD OF THE EMERGENCY EXIT WAS FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE #2 EMERGENCY LIGHT POWER SUPPLY BATTERY PACK, OPERATIONALLY TESTED WITH NO DEFECT, SDR ASOA201906294038Light · inoperativeIAH - FLIGHT 4197, THE CREW REPORTED THAT THE EMERGENCY LIGHT NEAR THE EXIT DOOR IN THE CEILING WAS INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE DEFECTIVE LIGHT BULB, OPERATIONALLY TESTED WITH NO DEFECTS AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICESDR DALA2019070104271Lens · broken(AIRCRAFT 7003, L/P 1145670) DOOR 2 RIGHT EXTERIOR DOOR EMERGENCY LIGHT LENS BROKEN. REPLACED LENS ASSY.SDR REXA2019062801056Battery · dischargedAFT WING EXIT LIGHTS @ ROW 13 NOT WORKING. R&R EMERGENCY BATTERY CHARGER AND BATTERY FOR EMERGENCY LIGHT AT ROW 13 AND AFT WING LIGHTS IAW AMM 33-51-17 OPS TEST NORMAL. CHARGER P/N 11-0049.SDR REXA2019062801055Battery · dischargedON PRE-FLIGHT INSP FOUND EMERGENCY LIGHTS INOP. CHARGED EMERGENCY LIGHT BATTERY USING GROUND POWER. PERFORMED OPS CHEK IAW AMM 33-51-00. NO DEFECTS NOTED AT THIS TIME. OK FOR SERVICE.SDR AALA201907029038Battery · dischargedAIRCRAFT NOT GROUNDED: ESPU BATTERY DEAD STATION 1522 TO 1546. MAINTENANCE REPLACED ESPU BATTERY PER STANDARD PRACTICES AND PERFORMED SATISFACTORY OPERATIONAL CHECK.SDR AALA201907029033Battery · dischargedAIRCRAFT NOT GROUNDED: ESPU BATTERY DEAD STATION 1497 TO 1522. MAINTENANCE REPLACED ESPU BATTERY PER STANDARD PRACTICES AND PERFORMED SATISFACTORY OPERATIONAL CHECK.SDR AALA201907029031Battery · dischargedAIRCRAFT NOT GROUNDED: ESPU BATTERY DEAD STATION 739 TO 764. MAINTENANCE REPLACED ESPU BATTERY PER STANDARD PRACTICES AND PERFORMED SATISFACTORY OPERATIONAL CHECK.SDR AALA201907029030Battery · dischargedAIRCRAFT NOT GROUNDED: ESPU BATTERY DEAD STATION 345 TO 368. MAINTENANCE REPLACED ESPU BATTERY PER STANDARD PRACTICES AND PERFORMED SATISFACTORY OPERATIONAL CHECK.SDR YENA201906280379Power Unit · failedFLT 1479, DCA-FLL. WHILE PERFORMING TASK CARD E-190-33-50-01-720-801 FWD, MID & AFT FROM WO 1001155. EMERGENCY LIGHT POWER UNIT FUNCTIONAL TEST FAILED ON STEP 8-C-A-A-3. (15 MIN STEP) ONLY THE CENTER FUSELAGE EMERGENCY EXIT SIGNS STAYED ON FOR 15 MINUTES. ALL SDR YENA201906280378Power Unit · failedFLT 1479, DCA-FLL. WHILE PERFORMING TASK CARD E-190-33-50-01-720-801 FWD, MID & AFT FROM WO 1001155. EMERGENCY LIGHT POWER UNIT FUNCTIONAL TEST FAILED ON STEP 8-C-A-A-3. (15 MIN STEP) ONLY THE CENTER FUSELAGE EMERGENCY EXIT SIGNS STAYED ON FOR 15 MINUTES. ALL SDR YENA201906280377Power Unit · failedFLT 1479, DCA-FLL. WHILE PERFORMING TASK CARD E-190-33-50-01-720-801 FWD, MID & AFT FROM WO 1001155. EMERGENCY LIGHT POWER UNIT FUNCTIONAL TEST FAILED ON STEP 8-C-A-A-3. (15 MIN STEP) ONLY THE CENTER FUSELAGE EMERGENCY EXIT SIGNS STAYED ON FOR 15 MINUTES. ALL SDR YENA201906280376Power Unit · failedFLT 1479, DCA-FLL. WHILE PERFORMING TASK CARD E-190-33-50-01-720-801 FWD, MID & AFT FROM WO 1001155. EMERGENCY LIGHT POWER UNIT FUNCTIONAL TEST FAILED ON STEP 8-C-A-A-3. (15 MIN STEP) ONLY THE CENTER FUSELAGE EMERGENCY EXIT SIGNS STAYED ON FOR 15 MINUTES. ALL SDR SWAA2019070234430Battery · failedEMERGENCY LIGHT BATTERY FAILED CAPACITY TEST AT LOCATION M1673. R&R BATTERY PER MM.SDR SWAA2019070234429Battery · failedEMERGENCY LIGHT BATTERY FAILED CAPACITY TEST AT LOCATION M1672. R&R BATTERY PER MM.SDR SWAA2019070234428Battery · failedEMERGENCY LIGHT BATTERY FAILED CAPACITY TEST AT LOCATION M1675. R&R BATTERY PER MM.SDR SWAA2019070234422Battery Pack · faultyCREW REPORTS ELECTRICAL SMELL WHEN FORWARD ENTRY LIGHT TURNED ON. R&R FORWARD EMERGENCY BATTERY PACK ASSEMBLY D10750 PER AMM.SDR SWAA2019070234393Sign · looseCEILING MOUNT OVERWING EXIT SIGN LOOSE. R&R LIGHT ASSEMBLY PER AMM.SDR SWAA2019070234330Battery · failedEMERGENCY LIGHT BATTERY FAILED CAPACITY TEST AT LOCATION M1669. R&R BATTERY PER MM.SDR FDEA201906281425Light · inoperativeEXTERIOR EMERGENCY LIGHT AFT OF L1 DOOR IS INOP. R&R LAMP REF MM 33_51_06_2_1. OPS CK GOOD.SDR SIMA20190628002Holder · defectiveEMER LIGHTS OFF POSITION, THEN BATTERIES OFF WITH GPU CONNECTED STRIP OF EMERGENCY LIGHTS ILLUMIMNATING AT ROWS 7 - 11 . F/A PANEL ALSO HAS EMERGENCY LIGHTS TURNED OFF. C/A-REPLACED BATTERY HOLDER ASSY #3 IAW AMM 33-50-04. OPS CHECK GOOD PER AMM 33-50-00.SDR DALA2019062903949Battery Pack · dischargedDURING SERVICE CHECK MAINTENANCE FOUND THE CEILING PANEL EMERGENCY LIGHTS WERE INOPERATIVE BETWEEN THE OVER WING EXITS TO THE AFT LAVATORIES. THE BATTERY PACK B5-231 WAS FOUND TO BE BAD AND WAS REPLACED. OPERATIONAL CHECK IS GOOD AND THE AIRCRAFT RETURNED TO SSDR MASA2019062811926Sign · inoperativeROW 13A FLR LVL EMER EXIT SIGN INOP. R & R LIGHT ASSY.SDR DALA2019070804272Lens · missing(AIRCRAFT 7102, L/P 5942430) WAC FOUND DOOR 3L UPPER EMER LENS COVER MISSING. R/R EXIT LIGHT BASE AND INST EXIT LIGHT LENS OVER L3 DOOR.SDR IPXA2019062843835Battery · lowINSPECTION TYPE:N/A EMERGENCY BATT LIGHT BATT LOW. DEFERRED PER MEL 33-50-4 DMP CW PLACARD INSTALLED. **SUPPLEMENTAL SDR** DMP REVERSED. REMOVE AND REPLACED EMERGENCY POWER BATTERY SUPPLY IAW AMM 33-51-01. OPS CHECKS GOOD. THIS CLEARS MEL M675066. IPC 33SDR AALA201906289005Light · brokenAIRCRAFT WAS NOT GROUNDED: EMERGENCY LIGHT BROKEN AT LAVATORY E (ISLE). ***SUPPLEMENTAL TO UPDATE SECTION 4 AND SECTION 5. MAINTENANCE REPLACED LIGHT ASSEMBLY AT LAVATORY E PER AMM 33-51-17 AND PEFORMED SATISFACTORY OPERATIONAL CHECK.*** (CLOSED)SDR AALA201906289004Light · brokenAIRCRAFT WAS NOT GROUNDED: EMERGENCY LIGHT BROKEN AT LAVATORY D (ISLE). ***SUPPLEMENTAL TO UPDATE SECTION 4 AND SECTION 5. MAINTENANCE REPLACED LIGHT ASSEMBLY AT LAVATORY D PER STANDARD PRACTICES AND PERFORMED SATISFACTORY OPERATIONAL CHECK.*** (CLOSED)SDR R61A201906270671Power Unit · inoperative**WHILE IN HEAVY CHECK** MAINTENANCE FOUND AFT SERVICE DOOR SURROUND EXIT LIGHT DOES NOT WORK. MAINTENANCE REMOVED AND REPLACED EMERGENCY POWER UNIT REF AMM 33-21-00, 33-50-01, AND 33-50-15.SDR JJBA20190627017Light · inoperativeLT EMERGENCY LIGHT FWD OF WING IS INOPERATIVE. R&R LT EMERGENCY LIGHT FWD OF WING. OPS CHECK SAT.SDR ASAA2019062729867Light · inoperativeWHEN ACCOMPLISHING T/C 7823008 EMERGENCY LIGHT OP'S CK. FOUND THE L-2 OUTER DOOR LIGHT TO BE OUT. GROUNDED - YES. REPLACED OUTER DOOR EMERGENCY LIGHT REF AMM 33-51-04-960-801 OPS CK GOOD.SDR ASAA2019062729845Lens · detachedLENS WILL NOT STAY ON R-2 DOOR. EXIT SIGN NEXT TO DOOR. GROUNDED - YES. REPLACED R2 DOOR EXIT SIGN IN REF TO AMM 33-51-01.SDR DALA2019062703970Cover · damagedIN SEAT EMER. LIGHT COVER DAMAGED AT 35C, REPLACED 35C IN SEAT EMER LIGHT COVER.SDR YENA201906270374Power Supply · failedFLT 1348, SJU-DCA. RED OVERWING EXIT EMERGENCY SEAT MARKER LIGHTS INOP; R & R EMERGENCY LIGHT POWER SUPPLY 12WL REF AMM 33-51-38. OPS CHECK GOOD.SDR DALA201906303934Power Supply · inoperativeEMERGENCY PATH LIGHTS INOPERATIVE ON THE RIGHT SIDE ROWS 16-29. REPLACED POWER SUPPLY AT DOOR 3R.SDR AALA201906289001Battery · inoperativeAIRCRAFT NOT GROUNDED: MAINTENANCE REPORTS 10WL FAILED EPSU SYSTEM TEST. REMOVED AND REPLACED 10WL EMERGENCY POWER SUPPLY UNIT IAW 33-51-38. OPS CHECK NORMAL.SDR ASOA2019062875082Battery Pack · inoperativeDURING MX INSPECTION THE OVERWING EMERGENCY LIGHTS AND FLOOR STRIP #6,7,8 WERE INOP. MX R&R #4 EMERGENCY LIGHT BATTERY PACK WITH OPERATIONAL CHECK GOOD. A/C WAS APPROVED FOR RETURN TO SERVICE.SDR AALA201906289002Light · unknownAIRCRAFT WAS NOT GROUNDED: EMERGENCY EXIT LIGHT IN BUSINESS CLASS RIGHT INOPERATIVE. MAINTENANCE ACCOMPLISHED SATISFACTORY OPERATIONAL CHECK PER AMM 33-51-01-960-801.SDR SWAA2019062834283Battery · no testEMERGENCY LIGHT BATTERIES FAILED CAPACITY TEST AT LOCATION M1675. R & R BATTERY IAW MM.SDR SWAA2019062834276Lamp · inoperativeR/H AFT LOWER EMERGENCY LIGHT INOP. RELAMPED LIGHT IAW AMM.SDR SWAA2019062834275Battery · no testEMERGENCY LIGHT BATTERIES FAILED CAPACITY TEST AT LOCATION M1673. R&R BATTERY PER MM.SDR SWAA2019062834247Sign · brokenL1 DOOR EMERGENCY EXIT SIGN BROKEN. R & R THE SIGN IAW MM.SDR SWAA2019062834245Lens · missingRIGHT FORWARD OVERWING EXIT DOOR MISSING LOWER LT EXIT SIGN LENS. REPLACED THE LENS IAW AMM.SDR DALA2019062803917Lens · missingEMERGENCY EXIT COVER DIFFUSER LENS MISSING AT LOCATION 600. MAINTENANCE REPLACED THE COVER WHICH WAS FOUND ON THE FLOOR. OPERATIONS IS NORMAL AND THE AIRCRAFT IS OKAY TO CONTINUE SERVICE. (LP #1143587)SDR SCNA20190627073Battery Pack · inoperativeMULTIPLE EMERGENCY LIGHTS OUT ON RH SIDE. REMOVED AND REPLACED 4 EA EMERLIGHT BATTERY PACKS. OPS CHECKS GOOD.
Back to JASC 3350