SDR 29GA2018122700001Cover · missingFLIGHT# 0130 MCO/FLL REPORT: F/A EMERGENCY PANEL, MISSSING COVER FOR PUSH BUTTON SWITCH. CORRECTIVE ACTION: FOUND AND RESECURED COVER IAW AMM 20-00-00.SDR SWAA2019030630336Cradle · defectiveRT EMERGENCY EXIT LIGHT INOP. R&R BATTERY CRADLE PER AMM.SDR SWAA2019010927978Battery Pack · dischargedLT EMERGENCY EXIT LIGHTS INOP. R&R BATTERY PACK PER AMM.SDR SWAA2019010927977Cradle · defectiveRT EMERGENCY EXIT LIGHT INOP. R&R BATTERY CRADLE PER AMM.SDR SWAA2019010328044Sign · looseMID CABIN EXIT SIGN LOOSE. REINSTALLED SIGN PER MM.SDR SWAA2019010227942Lens · looseOVERWING EXIT LIGHT LENS LOOSE. SECURED LENS PER MM.SDR AALA201812289007Light · inoperativeLEFT AFT EMERGENCY LIGHT ASSEMBLY WAS INOPERATIVE. REPLACED THE LIGHT ASSY IAW AMM 33-51-01. FUNCTIONAL CHECKED NORMAL.SDR DALA2018122607415Battery Pack · inoperative(LOG 5007820) DURING EMERGENCY LIGHT CHECK, FOUND ALL EMERGENCY LIGHTS INOPERATIVE AT AFT LEFT DOOR. REMOVED AND REPLACED BATTERY PACK IN POWER SUPPLY FOR AFT LEFT ENTRY DOOR. ALL LIGHTS OPS CHECK GOOD.SDR DALA2018122607390Battery Pack · inoperativeAFT OVERWING EXIT DOORS EXIT LIGHTS INOP. REPLACED BATTERY PACK B 5105 PER MD 88 AMM 33-53. INSTALLED COVER AND PANEL. CKS OK. (LP5221583)SDR MASA2018122511614Bulb · inoperativeROW 15 CEILING LEVEL EMER FLOOD LT INOP
PLACED ON MELSDR SWAA2019010227943Battery · failedFWD ZONE EMERGENCY LIGHTS BATTERY PACK FAILED TEST. R&R BATTERY PER MM.SDR SWAA2019010227940Light · inoperativeLT OVERWING EXIT LIGHT BULBS INOP. RELAMPED PER MM.SDR UIEA2018123162946Lamp · inoperativeEMERGENCY CEILING LIGHT IN CREW REST COMPARTMENT INOP.(<P>RELAMPED CREW REST CEILING EMERGENCY LIGHT</P>)SDR DALA20181227424Connector · disconnectedLEFT EMERGENCY LIGHTS ARE INOPERATIVE. FOUND DISCONNECTED CONNECTOR AND RE-SECURED. SYSTEM OPERATION IS NORMAL.SDR DALA2018122607403Light · unknownSHIP 3852 LH & RH MID EXIT LIGHTS ARE LIT DURING TEST AND NO INOP STICKERS INSTALLED . CORRECTIVE ACTION: DEFFERRED. (4990086).SDR IPXA2018122657235Battery Pack · dischargedEMERGENCY LIGHTS BATTERY 1 LOW. R & R THE BATTERY IAW AMM 33-51-01. OPS CHECKED GOOD.SDR YENA2018122640881Battery Pack · no testFT # 225, JFK-TPA. EMERGENCY LIGHT BATTERY 10WL FAILED TEST; REMOVED AND REPLACED EMERGENCY LIGHT BATTERY 10WL IAW AMM 33-51-38SDR SIMA201812264002Sign · inoperativeCOCKPIT DOOR STEP EXIT MARKER EMERGENCY LIGHT INOP "TRANSFERRED TO NRWC 851-DFW-02325"-C/A-REF NRWC 851-DFW-02335 RAR FORWARD EXIT IDENTIFIER SIGN IAW EMB 140 AMM 33-50-13, OP CK GOOD.SDR SIMA201812264003Lamp · inoperativeROW 12 CEILING EMERGENCY LIGHT INOP-C/A-RAR ROW 12 CEILING EMERGENCY LAMP IAW EMB AMM TASK# 33-50-08-000-801-A AND 33-50-08-400-801-A. OPC GOOD. ENDSDR DALA2018122607398Battery Pack · inoperativeMAINTENANCE FOUND MULTIPLE OVERHEAD EMERGENCY LIGHTS TO BE INOPERATIVE IN THE FORWARD CABIN. MAINTENANCE REPLACED A BATTERY PACK PER B717 AMM 33-51. OPERATIONAL CHECK WAS GOOD. (LP #3717838)SDR DALA2018122607397Battery Pack · inoperativeDURING THE SERVICE CHECK, MAINTENANCE FOUND THE MID EXIT ROW EMERGENCY SIGN LIGHT AT ROW 20 TO BE INOPERATTIVE. MAINTENANCE REPLACED THE BATTERY PACKS B5-230 AND B5-119 PER B717 AMM 33-51. OPERATIONAL CHECK WAS GOOD. (LP #5243255)SDR DALA2018122607395Battery Pack · inoperativeTHE AFT EMERGENCY EXIT SIGN IS INOPERATIVE. MAINTENANCE REPLACED THE AFT EMERGENCY EXIT LIGHT POWER SUPPLY BATTERY PER B717 AMM 33-51. OPERATIONAL CHECK WAS GOOD. (LP #4845153)SDR HNAA2018122600329Sign · inoperativeEMERGENCY EXIT SIGN ABOVE FWD FA'S SEAT INOP. RESET EMERGENCY LIGHT C/B, OPS CHECK FOR EMERGENCY SIGN ABOVE FWD F/A'S SEAT IS GOOD.SDR HNAA2018122600328Light · inoperativeNDIS 642 33-51 0002280 24DEC18 SBY CLOSE
EMEGENCY LIGHT IN FRONT OF ROW 3 INOP
FACT 24DEC18 09:44 SBY
R&R EMERGENCY LIGHT IN FRONT OF ROW 3, SECURED WITH
RETAINED HARDWARSDR F3LA2018122600483Battery · failedDISCREPANCY: REFERENCE LOG PAGE LP1133269 ITEM 1. FAILED EPSU SYSTEM TEST.
CORRECTIVE ACTION: REMOVED AND REPLACED EPSU 10WL AND EPSU 12WL. OPS CHECK GOOD. REF AMM 33-51-38-000-002-A AND AMM 33-51-38-400-002-A./END/SDR CALA2018122402643Battery Pack · faultyCIDS FAULT EMERGENCY EQUIPMENT "EPSU UNIT FWD L ATA 33-51-38" TRIED EPSU NO HELP SUSPECT BATTERY,NIS DEN,PART ON AOG. REMOVED PANEL FOR ACCESS IAW AMM 25-23-42 PANEL IN G1 AREA, BATTERY PN 3214-31 M&E 18-3351-3-0001 ON ORDER. REPLACED FWD L AND OVERWING L BATTSDR SWAA2019010428011Sign · brokenCENTER OVERWING EXIT SIGN BROKEN. R&R SIGN PER MM.SDR SWAA2018123128043Lens · missingLT LOWER EMERGENCY EXIT LIGHT LENS MISSING. INSTALLED LENS PER MM.SDR ASOA2018122834074Relay · inoperativeDFW - FLIGHT 2904 THE CREW REPORTED THAT THE EMER LIGHT ON STATUS MESSAGE CYCLES ON 2 SECOND INTERVALS WITH THE FA CONFIRMING THAT THE LIGHTS WERE FLASHING ION THE SAME CYCLE. MAINTENANCE INSPECTED THE AIRCRAFT AND REMOVED AND REPLACE RELAY JB11PCB5K135. OPERSDR ASAA2018122637559Cover · detachedBOTH EMERGENCY EXIT LIGHT COVERS LOCATED OVER AISLE AT WING EXIT LOCATION FELL OFF ON TAKE OFF AND NOT SECURED. GROUNDED - YES. RESECURED BOTH EMERGENCY EXIT LIGHT COVERS LOCATED IN MIDDLE WALKWAY ON THE CEILING IN AISLE 16.SDR UIEA2018122652917Battery Pack · inoperativeUPPER DECK EMERGENCY LIGHT INOP AT APROX STA 400 CENTER ISLE(<P>REMOVED AND REPLACED POWER SUPPLY BATTERY IAW AMM 33-51-04. OPERATIONAL CHECKS GOOD. </P>)SDR DALA2018122647394Power Supply · inoperativeFAILED OVER WING EMERGENCY LIGHTS. REPLACED BATTERY POWER SUPPLY. TEST OK. (LP# 0876006)SDR FDEA2018122433599Charger · inoperativeR1 EXTERIOR EMERGENCY SLIDE LIGHT WILL NOT TEST. RELAMPED BUT NO HELP.REF WDM 33-51-12, NO VOLTAGE AT LIGHT L30 ,HAS GOOD GROUND.REMOVED AND REPLACED POWER SUPPLY M730 REF MM 33-51-07-2.EMERGENCY LIGHT OPS CHECK NORMAL REF MM 33-51-00-5.A/C OK FOR SDR FDEA2018122433597Lamp · inoperativeL1 DOOR SLIDE EMERGENCY EXIT LIGHT INOP. RE-LAMPED, GRND CKS NORMAL.SDR MASA201812231610Power Supply · inoperativeR2 DOOR EMER EXIT SIGN INOP
REPLACED EMER LIGHT POWER SUPPLY UNITSDR MASA2018122311609Bulb · inoperativeGALLEY DOOR LWR EMER LIGHT OUT
REPLACED LIGHT BULBSSDR SWAA2019010328026Light · inoperativeLT OVERWING EXIT LIGHT INOP. RELAMPED PER MM.SDR SWAA2019010227948Light · missingLT AFT EEPLS STRIP SECTION MISSING. REPLACED EEPLS STRIP PER MM.SDR QXEA2018122800473Light · looseFLOOR LIGHTING STRIP LOOSE BETWEEN FORWARD GALLEY AND CABIN. REMOVED FROM SERVICE. SECURED PHOTOLUMINESCENT STRIP REF ERJ TASK 33-50-21-400-801-A NO FURTHER DEFECT NOTED. RETURNED TO SERVICE.SDR DALA2018122407381Light · unsecure(LP# 3993482) SEAT 18D MOUNTED EMERGENCY LIGHT KEEPS FALLING OFF. RESECURED. OPERATION CHECKS OKAY.SDR SIMA201812242001Lamp · inoperativeRH EXTERIOR EMERGENCY LIGHT ON OVERWING INOP.-C/A-RAR EXTERNAL EMERGENCY LIGHT RH LAMP IAW EMB 140 AMM 33-50-10. OPC GOOD.SDR CALA2018122402635Battery Pack · dischargedREF NR L/P 9469640 - SPEC NO. B777-33-3-7019 - DURING EMER PWR PACK CAPACITY CHK FOUND DR 4R M33409 BATTERY LOW VOLTAGE EMER LWR PACK ON DR 4R M33409 REPLACED, NEW BATTERY PACK TEST FA RRIED OUT FOUND MORMAL, REF AMM 33-51-06-960-802 REV.84 ADD EMP:V903182 IDTSDR CALA2018122402634Battery · dischargedREF NR L/P 9469641 - SPEC NO. B777-33-3-7019 - DURING EMER PWR PACK CAPACITY CHK FOUND DR 2L FWD M33096 BATTERY LOW VOLTAGE. EMER PWR PACK ON DR 2L FWD M33096 REPLACED, NEW BATTERY INSTALLA TION TEST CARRIED OUT FOUND NORMAL REF AMM 33-51-06-960-802 REV. 84 ADSDR CALA2018122402633Battery · dischargedREFER NR L/P 9469437 - SPEC NO. B777-33-3-7030 - DURING EMER LT BATTERY CAPACITY TEST FOUND DR 1L FWD BATTERY M33093 LOW VOLTAGE EMER PWR PACK ON DR 1L FWD M33093 REPLACED NWE BATTERY INSTALLAT ION TEST CARRIED OUT FOUND NORMAL REF AMM 33-51-06-960-802 REV.8 4SDR CALA2018122402632Battery · dischargedREFER NR L/P 9469436 - SPEC NO. B777-33-3-7025 - DURING LLAR EME R LT CAPACITY TEST FOUND LLAR ELECTRONIC COMPARTMENT BATTERY M02 3 LOW VOL VOLTAGE LLAR ELECTRONIC COMPARTMENT DWG PACK M023 REPLACED, NEW BATTERY TEST CARRIED OUT FOUND NORMAL, REF AMM 33-51-06-SDR CALA2018122432630Charger · failedREFER TO NRC LOG PAGE NO.: 9131401, SUPPORT TASK: L/H DR3 EMER CHARGER M33405 FOUND FAIL. L/H DR3 EMER CHARGER REPLACED AND INSTALLATION TEST CARRIED OUT RESULT NORMAL IAW AMM 33-51-06. ADD EMP:V896948SDR CALA201812243629Battery Pack · inoperativeREFER TO NRC LOG PAGE NO.: 9131399, SUPPORT TASK- L/H DR3 EMER SLIDE LIGHT, AREA LT AND EXIT INDENTIFIER FOUND INOP. L/H DR3 EMER BATTERY PACK REPLACED AND INSTALLATION TEST CARRIED OUT RESULT NORMAL IAW AMM 33-51-06. ADD EMP:V896948SDR MASA2018122211608Bulb · inoperativeFWD LT FLR LVL EMER LIGHT 6 BULBS OUT
SECURED LIGHT ASSYSDR SWAA2019011628484Power Supply · inoperativeLT AFT BATTERY PACK AT M01673 INOP. R&R BATTERY POWER SUPPLY IAW AMM.SDR SWAA2019011628004Battery Pack · dischargedLT AFT BATTERY PACK AT M01673 INOP. R&R BATTERY PACK IAW AMM.
Back to JASC 3350