SDR CALA2018100802064Battery · dischargedREF NR L/P:9462407 - SPEC NR B777-33-7-7019 - DOOR RT 4 BOTH EXIT IDENTIFIER WAS NOT ON WHEN EMERGENCY LIGHT TESTED. DOOR RT 4 BATTERY M33408 REPLACED AND OPERATIONAL TEST FOUND NORMAL AS PER AMM 33-51-06-960-802 REV83.SDR CALA2018100802063Battery · low voltageREF NR L/P:9458098 - SPEC NR B777-33-7-7019 - "C" ZONE SEAT EMERGENCY LIGHT POWER PACK FOUND LOW CAPACITY. DOOR L4 BATTERY M33407 REPLACED AND OPERATIONAL TEST FOUND NORMAL AS PER AMM 33-51-06-960-802 REV83.SDR CALA2018100802062Battery · low voltageREF NR L/P:9458095 - SPEC NR B777-33-7-7019 - "B" ZONE AFT L/H CEILING AREA EMERGENCY LIGHT POWER PACK FOUND LOW CAPACITY. DOOR L3 BATTERY M33400 REPLACED AND OPERATIONAL TEST FOUND NORMAL AS PER AMM 33-51-06-960-802 REV83.SDR CALA2018100802061Battery · low voltageREF NR L/P:9458094 - SPEC NR B777-33-7-7019 - "B" ZONE FWD RT CEILING AREA EMERGENCY LIGHT POWER PACK FOUND LOW CAPACITY. DOOR RH2 M33098 BATTERY REPLACED AND OPERATIONAL TEST FOUND NORMAL AS PER AMM 33-51-06-960-802 REV83.SDR CALA2018100802060Battery · low voltageREF NR L/P:9458093 - SPEC NR B777-33-7-7019 - "B" ZONE EY & PEY SEAT EMERGENCY LT POWER PACK FOUND LOW CAPACITY. DOOR R3 BATTERY M33404 REPLACED AND OPERATIONAL TEST FOUND NORMAL AS PER AMM 33-51-06-960-802 REV83.SDR CALA2018100802059Battery · dischargedREF NR L/P:9458090 - SPEC NR B777-33-7-7009 - "A" ZONE RT CEILING AREA EMERGENCY LIGHT POWER PACK FOUND LOW CAPACITY. DOOR L1 M33093 BATTERY REPLACED AND OPERATIONAL TEST FOUND NORMAL AS PER AMM 33-51-06-960-802 REV83.SDR MASA2018100791434Battery · discharged5 CEILING EMERGENCY FLOOD LIGHTS INOP. REPLACED BATTERY NR 2SDR DALA2018101105995Light · intermittentEMERGENCY CABIN LIGHTS COME ON ZONE 10 AFT & CABIN FLOOR OVERHEAD AND GALLEY WHEN LANDING/DECENT INTERMITTENT ON & OFF. OPS CK EMERGENCY LIGHTS PER AMM 33-51. NO TROUBLE FOUND. A/C OK FOR SVC.SDR DALA2018100905992Cover · unsecureEMERGENCY EXIT SIGN COVER LOOSE, LOCATIONS:604. COVER FOR EXIT SIGN IS OFF, INTERIOR. RE-SECURED SIGN COVER.SDR HNAA2018101100246Light · inoperativeRT OVER WING EMERGENCY LIGHT INOP. REMOVED AND REPLACED RT OVER WING EMERGENCY LIGHT LAMP IN REF TO AMM 33-50-10-000/400-801-A. OK FOR SERVICE.SDR SWAA2018100925841Battery Pack · dischargedFORWARD RT EMERGENCY LIGHT INOP AT M1675. R&R BATTERY PACK PER AMM.SDR SWAA2018100925840Battery Pack · dischargedFORWARD RT EMERGENCY LIGHT INOP AT M1674. R&R BATTERY PACK PER AMM.SDR SWAA2018100925839Battery Pack · dischargedFORWARD LT EMERGENCY LIGHT INOP AT M1675. R&R BATTERY PACK PER AMM.SDR SWAA2018100925832Battery Pack · inoperativeFORWARD LT EMERGENCY LIGHT INOP AT M1674. R&R BATTERY PACK PER AMM.SDR FDEA201810062807Holder · wornRT FWD DOOR EXT EMERGENCY LIGHT FAILS TEST. NOTED BULB ELECTRICAL CONTACT POINT WORN CAUSING INTERMITTENT BULB OPERATION, NEEDS NEW LIGHT ASSY. REMOVED & REPLACED LAMP HOLDER ASSY AS REQUIRED, P/N= 31-4964-5, S/N=N/A, GRND CKS NORMAL, REF AMM 33-51-06.SDR AALA201810099011Light · no testACCOMPLISHED EMERGENCY LIGHT TEST, TEST FAILED. ZONE 3 RIGHT SIDE UPPER AREA EMERGENCY LIGHTS ARE INOPERATIVE FROM ROW 26 TO 40. REPLACED THE POWER SUPPLY M33408 IAW MM 33-51-06. OPS CHECKED NORMAL.SDR AALA2018100989056Battery · dischargedLEFT AFT FLASHLIGHT BATTERY WAS DISCHARGED. REPLACED THE FLASHLIGHT BATTERY IAW AMM 25-25-40. OPS CHECKED GOOD.SDR DALA2018100905936Power Supply · inoperative(AIRCRAFT 7002, L/P 4680729) EMERGENCY LIGHTS FOUND INOP AT SEAT ROWS 29-43. REMOVED AND REPLACED EMERGENCY LIGHT POWER SUPPLY AT LOCATION M33404 AND OPS TESTED GOOD IAW AMM 33-51. OK FOR SERVICE.SDR I5EA2018100900003Battery Pack · depletedDISCREPANCY: EMERGENCY LIGHTS INOP AT M1197 AND STA 960L. CORRECTIVE ACTION: REMOVED AND REPLACED BATTERY PACK AT M1197 AND STA 960L PER AMM 33-51-51 OPS CHECK GOOD.SDR I5EA2018100900002Battery Pack · depletedDISCREPANCY: EMERGENCY LIGHTS INOP AT M1136 AND STA 753L. CORRECTIVE ACTION: REMOVED AND REPLACED BATTERY PACK AT M1136 AND STA 753L PER AMM 33-51-51 OPS CHECK GOOD.SDR AALA201810089049Power Supply · inoperativeAIRCRAFT WAS NOT GROUNDED. AFTER REPLACEMENT OF L4 SLIDE PER JOBCARD 26L00025010, STEP 7 OF JOB CARD WOULD NOT PASS TEST. MAINTENANCE REPLACED FORWARD LEFTHAND UNIT POWER SUPPLY PER AMM 33-51-38 AND PERFORMED SATISFACTORY OPERATIONAL CHECK.SDR DALA2018100705927Lens · missingRT AFT PASSENGER DOOR LOWER EMERGENCY EXIT LIGHT LENS MISSING. REPLACED RT AFT PASSENGER DOOR LOWER EMERGENCY EXIT LIGHT LENSSDR SIMA201810086001Light · inoperativeAFT FLOOR PROXIMITY STRIP AT ROW 16 INOP-C/A-REMOVED AND REPLACED AFT FLOOR PROXIMITY STRIP AT ROW 16A C/W IAW AMM 33-50-01. OPS IS GOOD.SDR MASA2018100711432Light · inoperativeROW 3 EMERGENCY FLOOD LIGHT INOP. PLACED ON MELSDR DALA2018101206005Power Supply · inoperativeWHEN CHECKING EMERGENCY LIGHTS IN CABIN, FOUND LEFT AND RIGHT MID CABIN AFT POS ISLE EXIT SIGNS WILL NOT ILLUMINATE. MAINTENANCE REPLACED POWER SUPPLY. SYSTEM OPERATION IS NORMAL.SDR SWAA2018100925779Lens · defectiveL1 DOOR LOWER EMERGENCY LIGHT LENS MISSING DIRECTIONAL ARROW. R&R LENS AMM.SDR SWAA2018100925778Lens · defectiveR1 DOOR LOWER EMERGENCY LIGHT LENS MISSING DIRECTIONAL ARROW. R&R LENS IAW AMM.SDR SWAA2018100925777Lens · missingL2 DOOR EMERGENCY EXIT SIGN MISSING COVER. INSTALLED LENS COVER IAW MM.SDR DALA2018100905953Battery Pack · discharged(AIRCRAFT 649, L/P 9214364) EMERGENCY SLIDE LIGHT AND O/H EXIT SIGN DOOR AT R1 DOOR INOP. CHARGED EMERGENCY LIGHT BATT PACKS PER AMM 33-51. OPS CHECKS GOOD.SDR DALA2018100905947Circuit Breaker · trippedSHIP 3805 LEFT OVER WING EXIT LIGHTS ILLUMINATED INFLT. CORRECTIVE ACTION: FOUND C/B A-10 0N P18-3 PANEL POPPED. RESET C/B OPERATED EMERGENCY LIGHTS PER SSM 33-51-11. EMERGENCY LIGHTS OPERATED NORMALLY. ( 4693628).SDR DALA2018100905946Light · detachedSHIP 3874 EMERGENCY FLOOR LIGHTING DAMAGED OR INOPERATIVE . CORRECTIVE ACTION: REATTACHED 223D LIGHT ASSY, NO DAMAGE NOTED. OPS NML (0771572).SDR R61A2018100951015Power Unit · inoperativeEMERGENCY LIGHT 4TH LIGHT AFT OF COCKPIT INOP. R&R EMERGENCY LIGHT POWER UNIT 3 IAW AMM 33-50-01.SDR IPXA2018100534720Light · inoperativeLOWER LAV LIGHT INOP. RELAMPED GROUND CHECKED GOOD REF MM 33-51-21.SDR AALA201810089013Lens · missingL3 DOOR EMERGENCY EXIT LIGHT LENS MISSING. INSTALLED THE LENS AT IAW AMM 33-50-00.SDR YENA2018101240681Battery · failedDURING HEAVY MAINTENANCE, EPSU BATRERY PACKS 10WL, 11WL, 12WL, 13WL FAILED OPERATIONAL CHECK; REF IAC N/R 13147-5802, R&R EPSU BATTERIES IAW AMM TASK 33-51-38-000-002, 33-51-38-400-002 OPS CHECK GOOD. 10WL: P/N OFF & ON 3214-31, S/N OFF 781924, S/N ON 811574
SDR YENA2018101240680Battery · failedDURING HEAVY MAINTENANCE, EPSU BATRERY PACKS 10WL, 11WL, 12WL, 13WL FAILED OPERATIONAL CHECK; REF IAC N/R 13147-5802, R&R EPSU BATTERIES IAW AMM TASK 33-51-38-000-002, 33-51-38-400-002 OPS CHECK GOOD. 10WL: P/N OFF & ON 3214-31, S/N OFF 781924, S/N ON 811574 1SDR YENA2018101240679Battery · failedDURING HEAVY MAINTENANCE, EPSU BATRERY PACKS 10WL, 11WL, 12WL, 13WL FAILED OPERATIONAL CHECK; REF IAC N/R 13147-5802, R&R EPSU BATTERIES IAW AMM TASK 33-51-38-000-002, 33-51-38-400-002 OPS CHECK GOOD. 10WL: P/N OFF & ON 3214-31, S/N OFF 781924, S/N ON 811574
SDR YENA2018101240678Battery · failedDURING HEAVY MAINTENANCE, EPSU BATRERY PACKS 10WL, 11WL, 12WL, 13WL FAILED OPERATIONAL CHECK; REF IAC N/R 13147-5802, R&R EPSU BATTERIES IAW AMM TASK 33-51-38-000-002, 33-51-38-400-002 OPS CHECK GOOD. 10WL: P/N OFF & ON 3214-31, S/N OFF 781924, S/N ON 811574
SDR SWAA2018101125878Lens · crackedLT OVERHEAD EMERGENCY LIGHT LENS CRACKED BETWEEN ROW 8 TO ROW 26. R&R LENS IAW AMM.SDR SWAA2018101125877Lens · crackedRT MAIN CABIN STOWBIN EMERGENCY LIGHT LENS CRACKED AT ROW 25. R&R LENS IAW AMM.SDR SWAA2018100925802Light · inoperativeLT OVERHEAD EMERGENCY EXIT LIGHT INOP AT ROW 17. RELAMPED LIGHT IAW AMM.SDR IPXA2018100534707Warning Message · false activationEMERGENCY LIGHT BATTERY 1 LOW LEVEL 1 ALERT DURING AN EMERG LIGHT TEST. REVERSED DMP 33-50-4. COMPLIED WITH FIM 33-51-00-101, & AMM 33-51-00, EMERGENCY LIGHTS CHECKED GOOD.SDR SWAA2018100925783Battery · failedEMERGENCY LIGHT BATTERY FAILED CAPACITY CHECK AT LOCATION M01670. R&R BATTERY PER AMM.SDR SWAA2018100925776Lens · unsecureMID CABIN OVERHEAD EMERGENCY EXIT LENS COVER FELL OFF. REINSTALLED COVER PER MM.SDR SWAA2018100925774Battery · failedEMERGENCY LIGHT BATTERY FAILED CAPACITY CHECK AT LOCATION M01673. R&R BATTERY PER AMM.SDR AALA201810059031Lens · missingRED LENS MISSING FROM AISLE LIGHT AT 10C. MAINTENANCE REPLACED THE LENS AND PERFORMED SATISFACTORY OPERTIONAL CHECK.SDR AALA201810059024Lens · missingEMERGENCY LIGHT COVER MISSING FROM THE RIGHT AFT EMERGENCY EXIT AND SEAT 10C LIGHTS. INSTALLED A NEW LENS.SDR AALA201810059018Light · unknownEMERGENCY EXIT LIGHTS RANDOMLY COME ON, RESET AND COME ON AGAIN. CIDS POWER UP TESTED OK IAW TSM 23-73-00-810-937A. PERFORMED AN OPS CHECK OF THE EMERGENCY LIGHTS, TESTED OK IAW AMM 33-51-00-710-001A. NO FAULT FOUND.SDR AALA201810059015Lens · missingEMERGENCY LIGHT LENS MISSING FROM THE RIGHT AFT EMERGENCY EXIT AND SEAT 10C. INSTALLED A NEW LENSSDR AALA201810059005Battery Pack · inoperativeAFTER AN EMERGENCY LIGHT TEST PS CHECK, FOUND THE BATTERY PACK WAS INOPERATIVE. REPLACED THE BATTERY PACK IAW AMM 33-51-06. CHECKED OK, OPS OK.