SDR AALA201806189031Power Supply · no testDURING EMERGENCY POWER SUPPLY UNIT TEST, A FAULT MESSAGE FOR THE EPSU 11WL EXT L. REPLACED THE POWER SUPPLY IAW AMM 33-51-38. OPS CHECKED GOOD. OK FOR SERVICE.SDR AALA201806189029Lens · brokenR4 DOOR EMERGENCY EXIT LIGHT LENS BROKEN. REPLACED THE LENS IAW AMM 33-51-13.SDR YENA201806185255Power Supply · failedPOWER SUPPLY 10WL FAULTED. REMOVED & REPLACED THE POWER SUPPLY IAW AMM 33-51-38.SDR DALA2018061854044Power Supply · inoperativeDURING A SERVICE CHECK, FOUND THE LOWER WING EMERGENCY EXIT LIGHT TO BE INOPERATIVE. MAINTENANCE DISCOVERED A BAD POWER SUPPLY B5-119 AND REPLACED IT. OPS CHECKED GOOD IAW AMM 33-51-03, AND WDM 33-51-12.SDR DALA2018061604036Battery · dischargedBOTH AFT OVERWING UPPER EXIT LIGHTS INOP. REPLACED BATTERIES AT B5105 REF AMM 33-53. OPS CHECK GOOD.SDR IPXA2018061530689Battery Pack · dischargedEMERGENCY LIGHT BATTERY 1 LOW, EMERGENCY LIGHT SYSTEM. REMOVED & REPLACED EMERGENCY POWER SUPPLY. OPS CHECKED GOOD.SDR DALA2018061954069Battery · inoperativeEMERGENCY LIGHTS ROWS 35-41 WERE INOPERATIVE. MAINTENANCE REPLACED THE BATTERY. SYSTEM OPERATION IS NORMAL.SDR DALA2018061954068Light · looseEMERGENCY SEAT MOUNTED LIGHTING AT 26B IS INOPERATIVE. FOUND HARDWARE MISSING AND REPLACED. SYSTEM OPERATION IS NORMAL.SDR DALA2018061954067Light · looseEMERGENCY FLOOR LIGHTS WERE INOPERATIVE AT 39B. FOUND ATTACHING HARDWARE LOOSE AND SECURED. SYSTEM OPERATION IS NORMAL.SDR SWAA2018061822876Battery · failedEMERGENCY LIGHT BATTERY FAILED CAPACITY TEST AT LOCATION M1675. R&R BATTERY PER AMM.SDR SWAA2018061822875Battery · failedEMERGENCY LIGHT BATTERY FAILED CAPACITY TEST AT LOCATION M1673. R&R BATTERY PER AMM.SDR SWAA2018061822874Battery · failedEMERGENCY LIGHT BATTERY FAILED CAPACITY TEST AT LOCATION M1674. R&R BATTERY PER AMM.SDR SWAA2018061822873Battery · failedEMERGENCY LIGHT BATTERY FAILED CAPACITY TEST AT LOCATION M1670. R&R BATTERY PER AMM.SDR SWAA2018061822872Battery · failedEMERGENCY LIGHT BATTERY FAILED CAPACITY TEST AT LOCATION M1669. R&R BATTERY PER AMM.SDR SWAA2018061822870Battery Pack · failedRT EMERGENCY LIGHTING BATTERY PACKS IN AFT GALLEY FAILED THE CAPACITY TEST. R&R BATTERY PACK PER AMM.SDR SWAA2018061822867Battery Pack · failedRT BATTERY PACKS FAILED CAPACITY CHECK. R&R BATTERY PACKS PER AMM.SDR SWAA2018061822860Battery · failedEMERGENCY LIGHT BATTERY FAILED CAPACITY TEST AT LOCATION M1672. R&R BATTERY PER AMM.SDR SWAA2018061822849Battery Pack · failedLT EMERGENCY LIGHTING BATTERY PACK FAILED CAPACITY TEST ROW 17. R&R BATTERY PACK PER AMM.SDR SWAA2018061822848Battery Pack · failedLT EMERGENCY LIGHTING BATTERY PACKS IN AFT GALLEY FAILED THE CAPACITY TEST. R&R BATTERY PACK PER AMM.SDR SWAA2018061822847Battery Pack · failedFORWARD RT BATTERY PACK FAILED CAPACITY CHECK. R&R BATTERY PACK PER AMM.SDR SWAA2018061822846Battery Pack · failedLT AFT BATTERY PACKS FAILED CAPACITY CHECK. R&R BATTERY PACKS PER AMM.SDR SWAA2018061822803Light · inoperativeR1 DOOR EXTERIOR SLIDE LIGHT INOP. RELAMPED LIGHT IAW MM.SDR SWAA2018061822795Lens · missingR1 DOOR EMERGENCY EXIT LIGHT MISSING ARROW. INSTALLED LIGHT LENS PER AMM.SDR AALA201806179002Battery · dischargedAIRCRAFT WAS NOT GROUNDED. EMERGENCY POWER SUPPLY UNIT 12WL BATTERY INOPERATIVE. REPLACED EMERGENCY POWER SUPPLY UNIT (12WL) BATTERY PER AMM 33-55-00. SYSTEM OPERATIONS CHECKS GOOD.SDR AALA201806179001Light · illuminatedAIRCRAFT WAS NOT GROUNDED. DOOR 3L EMERGENCY EXIT LIGHT ILLUMINATED. ACCOMPLISHED SATISFACTORY CIDS RESET. ALL EMERGENCY EXIT LIGHTS TEST OK PER AMM 23-13-00.SDR DALA2018061604034Battery · dischargedCATWALK EMERGENCY LIGHT INOP. REPLACED BATTERIES AT B5-28. CHECKS GOOD. REF AMM 33-53.SDR AALA201806159019Light · looseAIRCRAFT WAS NOT GROUNDED: EXIT PATH LIGHTING ON FLOOR NEAR SEAT 17C LOOSE. MAINTENANCE REPLACED EMERGENCY LIGHT BRACKET AS REQUIRED AND PERFORMED SATISFACTORY OPERATIONAL CHECK.SDR SIMA20180614002Light · inoperativeRT EXTERNAL OVERWING EMERGENCY LIGHT WILL NOT ILLUMINATE. R&R RT EXTERNAL OVERWING EMERGENCY LIGHT ASSY IAW AMM 33-50-10 OPS CK GOOD.SDR SIMA20180614001Light · inoperativeDURING PS-1 CHECK FOUND CEILING EMERGENCY FLOOD LIGHT TO BE INOP AT ROW 16. R&R CEILING EMERGENCY FLOOD LIGHT BULB IAW AMM 33-51-09. OPS CHECK GOOD.SDR FDEA201806141491Power Supply · inoperativeDURING PREFLIGHT OF SUPERNUMERARY AREA FOUND 2 EMERGENCY EXIT LIGHT INOP. R&R L1 POWER SUPPLE "M33093". P/N D717-02-001. S/N 157327. CHECKS OK REF MM 33-51-06-2. OK TO CONT.SDR KCSA201806141148Light · inoperativeUPPER DECK AND STAIRWELL EMERGENCY LIGHTS AT STA 350, 490, 500, AND 540 INOP.SDR SWAA2018072523788Light · brokenPASSENGER CABIN SIDEWALL EMERGENCY EXIT LIGHT ASSEMBLY BROKEN. R&R LIGHT IAW AMM.SDR SWAA2018072523787Lens · crackedAFT LAV EMERGENCY EXIT LIGHT LENS CRACKED. R&R LENS IAW AMM.SDR UIEA2018061801183Battery Pack · dischargedEMERGENCY FLOOR LIGHT FWD OF 20F INOP. R&R LT FLOOR LIGHT BATTERY PACK. OPS CHECK GOOD PER AMM 33-51-07.SDR DALA2018061944065Lens · missingL1 DOOR ENTRANCE LOWER EMERGENCY EXIT LENS MISSING, INSTALLED A LENSSDR AALA201806159008Power Supply · no testEMERGENCY POWER SUPPLY 13WL FAILED A CIDS TEST. REPLACED THE POWER SUPPLY IAW 33-51-38.SDR DALA2018061404028Light · looseSEAT 40 D EMERGENCY LIGHT CASE LOOSE. RPLD LIGHT CASE AT 40D - OP CK GOOD. REF AMM 33-51.SDR DALA2018061404025Light · inoperative1 SEAT MOUNTED EMER LIGHT INOP AT ROW 18D. REMOVED & REPLACED SEAT MOUNTED ASSY.SDR PNSA2018061302Relay · reads highEMERGENCY LIGHTS UNARMED CWP LIGHT ILLUMINATED WHEN EMER LIGHT SWITCH IS IN THE ARMED POSITION, EMERGENCY LIGHTS IN CABIN ON/OFF INTERMITTENTLY IN THIS CONDITION. FOUND RELAY 16LN OHMS READING HIGH, REMOVED AND REPLACED RELAY, OPS CHECK GOOD.SDR ASAA2018061325049Lens · detachedEMERGENCY EXIT LIGHT FELL OFF. GROUNDED - YES. RESECURED LIGHT LENS.SDR SWAA2018061422765Battery Pack · failedAFT RT SIDE BATTERY PACK IN AFT GALLEY FAILED CAPACITY TEST. R&R BATTERY PACK PER AMM.SDR SWAA2018061422764Housing · damagedPASSENGER CABIN FORWARD LAVATORY EMERGENCY LIGHT HOUSING DAMAGED ON AFT WALL LOWER AREA NEAR L1 DOOR. R&R LIGHT HOUSING IAW AMM.SDR SWAA2018061422758Cover · missingRT OVERWING EMERGENCY DOOR EXIT SIGN MISSING RED ARROW ON SIGN. INSTALLED SIGN IAW AMM.SDR SWAA2018061422753Light · inoperativeL2 DOOR EMERGENCY SLIDE LIGHT INOP. RELAMPED LIGHT PER AMM.SDR AALA201806149013Lens · missingEXIT LIGHT ABOVE THE AFT SERVICE DOOR, THE LENS WAS MISSING. INSTALLED A NEW LENS. OK FOR SERVICE.SDR F3LA2018061400356Battery Pack · inoperativeEPSU 10WL FORWARD LEFT, FAILED TO TEST. REMOVED AND REPLACED THE BATTERY PACK IAW AMM 33-51-38 PB 401. OPS CHECKED GOOD.SDR YENA201806143248Lens · detachedEXIT ROW EMERGENCY LIGHT AT 1C, LENS DETACHED. SECURED THE LENS IAW AMM 33-51-19.SDR DALA2018061403995Charger · inoperativeFIRST CLASS AND FWD GALLEY EMERGENCY LIGHTS INOP. R&R FWD BATTERY CHARGER PER AMM 33-50. OPS CHK GOOD.SDR DALA2018061303985Lens · missingLT FWD OVERWING EXIT EMER EXIT IDENTIFIER LENS MISSING. REMOVED & REPLACED EXIT IDENTIFIER ASSY OPS CHECK GOOD.SDR MASA2018061313321Light · inoperativeROW 17 OVERHEAD EMER FLOOD LIGHT INOP. PLACED ON MEL.
Back to JASC 3350