JASC 3350
Service difficulty reports · 225,591
Reports filed under 3350 · Emergency Lighting, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3350' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3350' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2026092819906Battery Pack · no testPOWER SUPPLY BATTERY PACK CAPACITY CHECK PROCEDURE. ALL LIGHTS ASSOCIATED WITH POWER SUPPLY M33098 EXTINGUISH WITHIN 5 MINUTES OF OPERATION. REPLACED THE BATTERY PACK ON EMERGENCY POWER SUPPLY M33098 LOCATED BEHIND OVER DOOR PANEL R2 DOOR, IAW AMM 33-51-06.SDR CALA2026092819902Battery Pack · no testPOWER SUPPLY, BATTERY PACK CAPACITY CHECK PROCEDURE. ALL LIGHTS ASSOCIATED WITH POWER SUPPLY M33094 EXTINGUISH AFTER APPROXIMATELY 3 MINUTES. REPLACED THE BATTERY PACK IAW AMM. 33-51-06-960-802, OP CHKD OK.SDR CALA2026092819896Battery Pack · dischargedEMERGENCY LIGHT BATTERY PACK M1673 HAS LOW CHARGE. REMOVED, REPLACED, AND OPS CHECKED GOOD THE EMER LIGHT BATTERY PACK M1673 IAW AMM 33-51-06.SDR CALA2026092819892Battery Pack · no testEMERGENCY LIGHT BATTERY PACK M3379 FAILS TO TEST. REPLACED AND OPS CHECKED GOOD OF M3379 BATTERY PACK IAW AMM 33-51-06. OPS CHKD GOOD.SDR CALA2026092819890Lamp · inoperativeEXTERIOR EMERGENCY LIGHT NEAR L2 DOOR IS INOPERATIVE. REPLACED THE LAMPS IAW AMM 31-51-04. OPS CHECK GOOD IAW AMM 31-51-04.SDR AALA202609276518Light · inoperativeAIRCRAFT WAS NOT GROUNDED: EMERGENCY PATH LIGHT (WHITE) AT SEAT 24C INOPERATIVE - MAINTENANCE REPLACED THE LIGHT AND ACCOMPLISHED A SATISFACTORY OPERTATIONAL CHECKSDR DALA2026092905418Battery Pack · inoperativeEMERGENCY CEILING LIGHT ABOVE 30ABC INOPERATIVE. REPLACED THE BATTERY PACK AT 29 ABC IAW AMM 33- 31, OPS CHKD GOOD. (9444387) AIRCRAFT WAS GROUNDED.SDR SWAA2026092916162Sign · unsecurePASSENGER CABIN, CEILING EXIT SIGN UNSECURE. SECURED THE SIGN IAW AMM 33-51-01-960-802, STEP 3.C. (6) (E).SDR SWAA2026092988170Battery Pack · inoperativeRIGHT AFT EMERGENCY EXIT LIGHTS WERE INOPERATIVE. REPLACED THE BATTERY PACK IAW AMM 33-51-06-960-805, 21-23-03-000-801, & 21-23-03-400-802.SDR SWAA2026092907824Battery Pack · inoperativeLEFT EMERGENCY EXIT LIGHT WAS INOPERATIVE. REPLACED THE BATTERY PACK IAW AMM 33-51-06-960-805, 21-23-03-000-801, & 21-23-03-400-802.SDR SWAA2026092906455Lamp · inoperativeEMERGENCY EXIT LIGHT AT R1 DOOR WAS INOPERATIVE. REMOVED AND REPLACED THE LAMPS IAW AMM 33-51-04-960-801.SDR SWAA2026092967279Lamp · inoperativePASSENGER CABIN EMERGENCY LIGHT OVER SEAT 6ABC WAS INOPERATIVE. R & R THE LAMP IAW AMM 33-51-03-960-801. TEST PASSED.SDR SWAA2026092935990Light · inoperativeEMERGENCY LIGHT AFT OF RT WTB FAIRING WAS INOPERATIVE. REPLACED THE EMERGENCY LIGHT IAW AMM 33-51-00-710-801. TESTED OK.SDR QXEA2026092900177Sign · brokenL1 BOTTOM EMERGENCY EXIT SIGN BROKEN. REMOVED FROM SERVICE. PLACED ON DMI. DMI CLEARED BY REPLACING THE SPACER ASSY IAW CMM 25-41-80 SUBTASKS 25-41-80-000-801-A01 A.4 & 25-41-80-400-801-A01 A.35. REINSTALLED EXIT IDENTIFIER SIGN IAW AMM TASK 35-50-15-400-801-SDR ASAA2026092567100Light · missingPHOTOLUMINESCENT ESCAPE PATH LIGHTING MISSING DIAGONAL SECTION. GROUNDED - YES. REPLACED DIAGONAL ESCAPE PATH LIGHTING AT 14G PER AMM 33-51-06. OPS CHECK GOOD. OK TO CONTINUE.SDR AALA202609281619Battery Pack · no testAIRCRAFT IN BASE MAINTENANCE: SEATS 9H & 10H, FAILED EMERGENCY LIGHT BATTERY PACK CAPACITY CHECK. MAINTENANCE REPLACED BATTERY PACK IAW AMM 33-51-06.SDR AALA202609288418Battery Pack · no testAIRCRAFT IN BASE MAINTENANCE: SEATS 2H - 5H EMERGENCY LIGHTS INTERMITTENT DURING EMERGENCY LIGHT CHECK. MAINTENANCE REPLACED BATTERY PACK IAW AMM 33-51-06.SDR SIMA20260925002Battery · inoperativeFLIGHT DECK OVERHEAD EMERGENCY LIGHT INOP. R A R #1 EMRGENCY BATTERY PACK PER AMM 33-50-01 OPS CK GOOD PER AMM 33-50-00SDR CALA2026092819923Elec Connector · dirtyOPS TEST OF EMERGENCY ESCAPE PATH LIGHTING (EEL) SYSTEM. THE EMERGENCY EXIT LIGHTS FROM RT AFT & LT AFT SERVICE DOORS DOES NOT COMES ON ABOVE THE WINDOW. PERFORMED FIM 33-51, FAULT TREE 812, FOUND ELECT CONNECTOR D10722 IAW WDM 33-51-11-1 WITH BAD CONTACT, SDR CALA2026092819905Power Supply · no testEMERGENCY LIGHTS OPS TEST WITH THE TEST SWITCH PROCEDURE. SEAT ROWS 35 THRU 39 EMERGENCY EXIT LIGHTS INOPERATIVE. R & R THE POWER SUPPLY ASSY IAW AMM 33-51-07-862-029-002. OPS CHKD OK.SDR CALA2026092819899Battery Pack · no testEMERGENCY ESCAPE PATH LIGHTING TEST FAILED. R & R BATTERY PACK REF AMM 33-51-06, OPS CHKD GOOD.SDR CALA2026092819895Battery Pack · no testEMERGENCY LIGHTS, OPS TEST WITH THE TEST SWITCH. R4 DOOR INTERIOR AND EXTERIOR EMERGENCY LIGHTS INOPERATIVE. REPLACED M00736 BATTERY PACK IAW AMM 33-51-07-902-005-002, TESTED OK.SDR AALA202609275701Battery · no testAIRCRAFT WAS NOT GROUNDED: EMERGENCY POWER SUPPLY UNIT 15WL BATTERY NEED TO BE REPLACED - REPLACED BATERY AND ACCOMPLISHED A SATISFACTORY OPERATAIONAL CHECK PER AMM 33-51-38SDR AALA202609279555Battery · no testAIRCRAFT WAS NOT GROUNDED: EMERGENCY POWER SUPPLY UNIT 12WL BATTERY NEED TO BE REPLACED - REPLACED BATERY AND ACCOMPLISHED A SATISFACTORY OPERATAIONAL CHECK PER AMM 33-51-38SDR AALA202609272418Battery · no testAIRCRAFT WAS NOT GROUNDED: EMERGENCY POWER SUPPLY UNIT 11WL BATTERY NEED TO BE REPLACED - REPLACED BATERY AND ACCOMPLISHED A SATISFACTORY OPERATAIONAL CHECK PER AMM 33-51-38SDR AALA202609276251Battery · no testAIRCRAFT WAS NOT GROUNDED: EMERGENCY POWER SUPPLY UNIT 10WL BATTERY NEED TO BE REPLACED - REPLACED BATERY AND ACCOMPLISHED A SATISFACTORY OPERATAIONAL CHECK PER AMM 33-51-38SDR SWAA2026102777205Battery Pack · inoperativeINOPERATIVE BATTERY PACK FOR EMERGENCY LIGHTS RT SIDE CENTER CABIN. REPLACED THE BATTERY PACK IAW AMM 33-51-06-960-805, TESTED OK.SDR SWAA2026102721134Battery Pack · inoperativeINOPERATIVE BATTERY PACK OF EMERGENCY LIGHTS LT SIDE CENTER CABIN. REPLACED BATTERY PACK OF EMERGENCY LIGHTS LT SIDE CENTER CABIN IAW AMM 33-51-06-960-805. TESTED OK.SDR SWAA2026092863548Battery Pack · no testRIGHT FWD EMERGENCY LIGHTING BATTERY PACK FAILED THE CAPACITY CHECK. REMOVED AND REPLACED BATTERY PACK PER M/M 33-51-06.SDR SWAA2026092856721Battery Pack · no testLEFT AFT EMERGENCY LIGHT BATTERY PACK MO1573 FAIL A CAPACITY CHECK. R & R LT AFT EMERGENCY LIGHT BATTERY PACK MO1573 IAW AMM 33-51-06.SDR SWAA2026092852086Light · inoperativeAFT ENTRY EXTERIOR EMERGENCY LIGHT INOP RELAMPED AFT ENTRY SLIDE EMERGENCY LIGHT IAW AMM 33-51-04. OPS CHKD GOOD.SDR SWAA2026092851905Battery Pack · no testLEFT FWD EMERGENCY LIGHT BATTERY PACK MO1675 FAIL CAPACITY CHECK. REMOVED AND REPLACED LT FWD EMERGENCY LIGHT BATTERY PACK MO1675 IAW AMM 33-51-06.SDR SWAA2026092891636Battery Pack · no testTHE EMERGENCY LIGHTING BATTERY PACK AT THE LT OVERWING EXIT FAILED THE CAPACITY CHECK. REMOVED AND REPLACED BATTERY PACK IAW MM 33-51-06.SDR AALA202609282106Bulb · inoperativeAIRCRAFT IN BASE MAINTENANCE: DOOR 4L HAS BULB OUT IN EMERGENCY EXIT SIGN. MAINTENANCE REPLACED BULB IN EMERGENCY EXIT SIGN AT DOOR 4L IAW AMM 33-51-01-960-801 AEROMAN FAA CRS# RJEY598H.SDR SIMA20260924002Light · detachedFWD RT EMERGENCY PHOTOLUMINESCENT STRIP NOT GLOWING. DEFERRED PER MEL 33-32 AUTH # 091477-C. FWD RH EMERGENCY PHOTOLUMINESCENT STRIP NOT GLOWING. REMOVED AND REPLACED PHOTOLUMINESCENT INDICATOR STRIP LIGHT IAW AMM 33-50-21. MEL 33-32 IS RESTORED.SDR CALA2026092819852Light · brokenWING EMERGENCY EXIT 21F TRIM BROKEN. RESECURRED TRIM AT SEAT 21F AS REQUIRED.SDR CALA2026092819851Light · detachedEMERGENCT PATH LIGHT BROKEN OFF MOUNT AT 14C RESECURED EMERGENCY FLOOR PROXIMITY LIGHT AT SEAT 14C. OPS NORMAL REF AMM 33-51-00. OK TO CONTINUE.SDR AALA202609276165Battery · faultedAIRCRAFT WAS NOT GROUNDED: FOUND EMERGENCY POWER SUPPLY UNIT AFT LEFT FAULT ON PERIODIC SERVICE CHECK. MAINTENANCE REPLACED BATTERY AT EMERGENCY POWER SUPPLY UNIT (13WL). RESET EMPERGENCY POWER SUPPLY UNIT. ALL CHECKS NORMAL. OK FOR SERVICE. REFERENCE AMM 33-5SDR AALA202609275304Battery · faultedAIRCRAFT WAS NOT GROUNDED: FOUND EMERGENCY POWER SUPPLY UNIT BATTERY FORWARD LEFT FAULT ON PERIODIC SERVICE CHECK. MAINTENANCE REPLACED BATTERY AT EMERGENCY POWER SUPPLY UNIT (10WL). ALL CHECKS NORMAL. OK FOR SERVICE. REFERENCE AMM 33-51-38.SDR AALA202609278989Sign · inoperativeAIRCRAFT IN BASE MAINTENANCE: AFT LEFT DOOR (L2 DOOR) EXIT SIGN DOES NOT ILLUMINATE. MAINTENANCE REPLACED EXIT SIGN AT L2 DOOR PART NUMBER 10-1310-1 PER AMM 33-51-11 OPS CHECK OK.SDR DALA2026092505356Battery Pack · no testDURING SERVICE CHK, FOUND EMERGENCY LIGHTS INOPERATIVE FROM ROW 10-15. R & R BATTERY PACK M1676 IAW AMM 33-51. OPS CHKD GOOD. (8955601) AIRCRAFT WAS GROUNDEDSDR AALA202609252779Power Supply · inoperativeAIRCRAFT WAS NOT GROUNDED: EMERGENCY LIGHT CEILING AREAS LEFT SIDE OF AISLE FROM SEAT 17C TO 25C NOT WORKING. REMOVED AND REPLACED POWER SUPPLY (M33400) IAW AMM 33-51-06.SDR AALA202609257318Sign · inoperativeAIRCRAFT IN BASE MAINTENANCE: L2 DOOR EXIT SIGN DOES NOT ILLUMINATE - MAINTENANCE REPLACED EXIT SIGN AT L2 DOOR AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 33-51-11SDR AALA202609253276Bulb · inoperativeAIRCRAFT IN BASE MAINTENANCE: EMERGENCY LIGHTS FAIL SYSTEM OPERATION TEST WITH FAULT MESSAGE EPSU EXT LOAD EMER L DISPLAYED - MAINTENANCE REPLACED LIGHT BULB CM 1810 ON THE LEFT AFT FAIRING AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 33-51-15SDR REXA2026092501878Lamp · inoperativeTWO EMERGENCY FLOODLIGHT LAMPS INOP. R & R THE LAMPS IAW AMM 33-51-05. OPS CHECKED GOOD.SDR CALA2026092519832Fuse · blownRIGHT EXTERIOR EMERGENCY EXIT LIGHT BTWN OVERWING DOORS IS INOPERATIVE. REMOVED AND REPLACED FUSE AT M1671 PWR SUPPLY IAW AMM 33-51-06-960-804 & PERFORMED EMERGENCY LIGHT OPS CHECK GOOD IAW AMM 33-51-00-710-801.SDR CALA2026092519830Battery Pack · inoperativeRIGHT OVERWING EXIT LIGHTS INOPERATIVE. M1695 BATTERY PACK REMOVED AND REPLACED, OPS CHECKED GOOD M1695 BATTERY PACK IAW AMM 31-51-06.SDR CALA2026092519828Battery Pack · inoperativeR2 DOOR EMERGENCY LIGHTS INOP. M1672 BATTERY PACK. REMOVED AND REPLACED THE BATTERY PACK IAW AMM 31-51-06.SDR CALA2026092519826Power Supply · faultedEPSU BATTERY FAULT FIN 12WL. REPLACED EPSU AND BATTERY AT LOCATION 12WL IAW AMM 33-51-38, OPS CHKD OK.SDR CALA2026092519824Battery Pack · no testOPS CHECK OF EMERGENCY LIGHTS. RT OVERWING INTERIOR DOOR EXIT SIGNS INOPERATIVE. REMOVED AND REPLACED THE BATTERY PACK M1695 IAW AMM 33-51-06-960-805. OPS CHECKED NORMAL.
Back to JASC 3350