JASC 3350
Service difficulty reports · 225,886
Reports filed under 3350 · Emergency Lighting, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3350' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3350' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA20161003003Battery Pack · inoperativeOVERHEAD EMERGENCY LIGHTS AT ROW 30 AND AFT GALLEY COME ON WITH ALL POWER REMOVED FROM AIRCRAFT. REMOVED AND REPLACED EMERGENCY LIGHT BATTERY ASSEMBLIES AT ROWS 25 AND 29 IAW AMM 33-53-00. OPERATIONAL CHECK GOOD IAW AMM 33-53-00. SEE ALSO AALA20161001003.SDR AALA20161001004Battery Pack · inoperativeDURING EMERGENCY LIGHTS TEST REQUIRED BY PS CHECK, EMERGENCY PROXIMITY LIGHTS DID NOT TURN ON. REMOVED AND REPLACED BATTERY PACK M33401 AND TESTED IAW AMM 33-51-06. SYSTEM GOOD FOR SERVICE.SDR AALA20161001003Battery Pack · inoperativeOVERHEAD EMERGENCY LIGHTS AT ROW 30 AND AFT GALLEY COME ON WITH ALL POWER REMOVED FROM AIRCRAFT. REMOVED AND REPLACED EMERGENCY LIGHT BATTERY ASSEMBLIES AT ROWS 25 AND 29 IAW AMM 33-53-00. OPERATIONAL CHECK GOOD IAW AMM 33-53-00.SDR AALA20160930008Lens · looseR1 DOOR SLIDE LIGHT LENS IS NOT SECURE. RESECURED LENS IAW AMM 33-51-04.SDR DALA2016100206980Epsu · faultyDURING FLIGHT COMPARTMENT HFA CHECK, FOUND EPSU 19WL AND 12WL FAULT. REPLACED EPSU 19WL AND 12WL EPSU BATTERY.SDR CALA2016100300715Sign · brokenEXIT IDENTIFIER ASSY AT 20A BROKEN FOR OVERWING EXIT. REPLACED EXIT IDENTIFIER ASSY M/E 29-3351-3-0069 AT SEAT 20A, OPS NORMAL. REF AMM 33-51-01.SDR N6WA2016100101Light · inoperativeROW 11 CEILING EMERG LIGHT INOP. DEFERRED ROW 11 CEILING EMERGENCY LIGHT PER MEL 33-51-01B CAT C.SDR SIMA20161001001Cover · crackedLT EMERGENCY FLOOR LIGHTING STRIP JUST AFT OF EMERGENCY EXIT ROW HAS CRACKED COVER. R&R LT EMERGENCY FLOOR LIGHTING STRIP COVER JUST AFT OF EMERGENCY EXIT ROW IAW AMM 33-51-01.SDR JJBA20161001001Light · inoperativeEMERGENCY LIGHT NOT ILLUMINATING. R&R LIGHT.SDR KCSA201610011074Guard · brokenEMERGENCY LIGHT SWITCH GUARD BROKEN ON P5 PANEL.SDR SWAA2016101108627Light · crackedNR 4 GALLEY EXIT LIGHT ASSEMBLY CRACKED. R & R LIGHT ASSEMBLY IAW AMM.SDR YENA20160930900Battery · failedDURING A ROUTINE MAINTENANCE INSPECTION, THE RT AFT EXIT EMERGENCY LIGHT AND EMERGENCY CEILING LIGHT AT ROW 21, WERE FOUND TO BE INOPERATIVE. ; REMOVED & REPLACED EMERGENCY BATTERY IAW AMM 33-50-01. PERFORMED OPS CHECK. OPS CHECK PASSED.SDR DALA2016093007032Battery Pack · inoperativeCEILING EMERGENCY LIGHTS ROW 21 AND 23 INOPERATIVE. FOUND BATTERY PACK AT M10919 BAD. REPLACED BATTERY PACK PER B757 AMM 33-51-07. OPS CHECKS GOOD. (9313692)SDR SWAA2016100308400Lens · missingRIGHT AISLE EMERGENCY LIGHT LENS MISSING AT ROW 10. R & R LENS IAW SIP.SDR SWAA2016100308394Sign · inoperativeR1 DOOR EXIT SIGN AT FLOOR LEVEL INOPERATIVE. R & R THE SIGN IAW MM.SDR SPAA20161001Light · inoperativeAFT CABIN EMERGENCY FLOOR TRACK LIGHT INOPERATIVE.SDR ASAA2016093018167Lamp · burned outLEFT AFT EXTERIOR WING TO BODY EMERGENCY EXIT LIGHT BURNT OUT. ACFT GROUNDED. REPLACED THE LAMP AND PERFORMED GOOD FUNCTIONAL CHECK IAW AMM 33-51-04.SDR AALA201610039025Lens · missingSEAT ROW 3 LEFT ESCAPE LIGHT LENS COVER MISSING. INSTALLED A NEW COVERT AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK IAW AMM 33-51-00-710-001-A.SDR AALA201610029006Sign · missingL1 EMERGENCY SIGN MISSING. REPLACED L1 DOOR EMERGENCY SIGN IAW AMM 33-51-13.SDR AALA201610029004Lens · missingSEAT ROW 1 LEFT ESCAPE LIGHT LENS COVER MISSING. INSTALLED NEW LENS AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK IAW AMM 33-51-00-710-001-A.SDR AALA201610029001Lens · missingR2 DOOR EMERGENCY LIGHT COVER MISSING. INSTALLED A NEW LENS ON THE EMERGENCY LIGHT.SDR R61A201609300563Warning Message · false activationCREW REPORTED AN EMERGENCY LIGHT BATTERY FAULT MESSAGE. MAINTENANCE RESET EMERGENCY LIGHTS IAW AMM AND OPS CHECKED GOOD.SDR DALA2016100206971Charger · inoperativeDURING TESTING FOUND FORWARD RIGHT EMERGENCY LIGHT BATTERY CHARGER STATION 303.1 INOPERATIVE. MAINTENANCE REPLACED FORWARD GALLEY EMERGENCY LIGHT BATTERY CHARGER STATION 303.1 PER AMM 33-51 OP CKS GOOD.SDR SIMA20160930001Light · inoperativeRT OVERWING EMERGENCY LIGHT INOP. R&R RT OVERWING EMERGENCY LIGHT BULB, OPS GOOD IAW AMM 33-50-07.SDR MASA2016093012431Sign · inoperative4D BULKHEAD EXIT SIGN WILL NOT ILLUMINATE.SDR ASOA20160931024Battery · dischargedA/C WAS IN FOR AN A-CHECK WHEN INSPECTION FOUND THE LAST 3 FLOOR EMERGENCY STRIPS OUT. MAINTENANCE R&R THE BATTERY SUPPLY IAW AMM 25-22-04; IPC 33-50-04, FIGURE 01 ITEM 30. OPS CHECK GOOD AND WAS RELEASED.SDR CALA2016093000710Switch · damagedEMERGENCY LIGHTS SWITCH DAMAGED. EMER EXIT LIGHTS COME ON INTERMIT IN ARMED POSITION ACCOMPLISHED FIM TASK 33-51 TASK 801, CHECK OK.SDR UHLA201609300445Power Unit · inoperativeAFT GALLEY EMERGENCY EXIT SIGN WILL NOT ILLUMINATE WITH EMERGENCY LIGHTS TO ON. R&R AFT RT IB EMERGENCY POWER UNIT IAW AMM 33-50-01. ALL FAULTS CLEARED.SDR HNAA2016093000302Light · inoperativeFIRST EMERGENCY FLOOR LIGHT FROM FRONT IS INOP. REMOVED AND REPLACED BULB. OPS CHECKED GOOD.SDR HNAA2016093000301Light · inoperativeFIRST EMERGENCY FLOOR LIGHT IS INOP. REMOVED AND REPLACED FIRST EMERGENCY LIGHT BULB. OPS CHECKED GOOD.SDR MASA2016093012429Light · inoperativeROW 9 CEIL EMERG LIGHT INOP. PLACED ON MEL.SDR JJBA20160930015Sign · unsecureEMERGENCY EXIT SIGN OVER MAIN CABIN DOOR FELL DOWN. RE-SECURED EXIT LIGHT ASSEMBLY. OPS CHECK SAT.SDR DALA2016100407078Battery Pack · inoperativeOVERWING EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED BATTERY PACK B5-229. OPERATION CHECKS GOOD.SDR DALA2016093007029Cover · detachedEMERGENCY SEAT MOUNTED LIGHTING DAMAGED. REATTACHED COVER. (2703678)SDR SWAA2016100308371Lens · crackedAFT GALLEY ENTRY EMERGENCY EXIT LENS CRACKED. REPAIRED LENS IAW AMM.SDR DALA2016092906983Battery Pack · dischargedCEILING MOUNTED EMERGENCY LIGHTS INOP AT ROW 3+4. REPLACED EMERGENCY LIGHT BATTERY PACK AT ROW 4 PER AMM 33-53-00.SDR AALA201609309014Lens · missingAIRCRAFT WAS NOT GROUNDED. FLOOR LEVEL EMERGENCY EXIT LIGHT LENS MISSING DOOR R-4. REATTACHED MISSING LENS AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.SDR AALA201609309012Lens · missingAIRCRAFT WAS NOT GROUNDED. EMERGENCY EXIT LIGHT LENS COVER AT SEAT 9D MISSING. INSTALLED LENS COVER PER AMM 33-51-01-10.SDR AALA201609309006Lens · brokenAIRCRAFT WAS NOT GROUNDED. SEAT ROW 9, EMERGENCY EXIT LENS COVER BROKE. REPLACED LENS COVER PER AMM 33-51-19-400-001-A.SDR AALA201609309005Lens · missingAIRCRAFT WAS NOT GROUNDED. EMERGENCY LIGHT LENS MISSING SEAT 30C. INSTALLED LENS AT SEAT 30C PER AMM 33-51-18.SDR AALA201609309004Lens · missingAIRCRAFT WAS NOT GROUNDED. EMERGENCY LIGHT LENS MISSING SEAT 25C. INSTALLED LENS AT SEAT 25C PER AMM 33-51-18.SDR SIMA20160929001Inverter · defectiveDURING PS-2, FOUND EMERGENCY LIGHT STRIP FROM ROW 3A TO 7A VERY DIM. R&R DC/AC INVERTER NR 2 IAW AMM 33-50-11. OPS CHECK GOOD.SDR SWAA2016093008331Battery · failedEMERGENCY LIGHT BATTERY FAILED CAPACITY TEST AT LOCATION M1675. R&R BATTERY PER AMM.SDR SWAA2016093008330Battery · failedEMERGENCY LIGHT BATTERY FAILED CAPACITY TEST AT LOCATION M1674. R&R BATTERY PER AMM.SDR SWAA2016093008329Battery · failedEMERGENCY LIGHT BATTERY FAILED CAPACITY TEST AT LOCATION M1673. R&R BATTERY PER AMM.SDR SWAA2016093008328Battery · failedEMERGENCY LIGHT BATTERY FAILED CAPACITY TEST AT LOCATION M1670. R&R BATTERY PER AMM.SDR SWAA2016093008327Battery · failedEMERGENCY LIGHT BATTERY FAILED CAPACITY TEST AT LOCATION M1669. R&R BATTERY PER AMM.SDR SWAA2016093008326Battery · failedEMERGENCY LIGHT BATTERY FAILED CAPACITY TEST AT LOCATION M1668. R&R BATTERY PER AMM.SDR SWAA2016093008313Light · inoperativeL1 DOOR EMERGENCY EXIT SIGN LIGHT INOP. R&R SIGN ASSEMBLY PER MM.SDR SWAA2016093008311Cover · unsecureL1 DOOR EXIT SIGN COVER FELL OFF. R&R LIGHT ASSEMBLY PER MM.
Back to JASC 3350