JASC 3350
Service difficulty reports · 225,886
Reports filed under 3350 · Emergency Lighting, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3350' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3350' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA201606309002Light · unsecureEMERGENCY LIGHT ON SEAT 15C INOPERATIVE. SECURED EMERGECNY LIGHT FIXTURE FOR SEAT 15C.SDR VNAA2016062900033Sign · unsecureEMERGENCY EXIT SIGN FELL DOWN. MAINTENANCE INSPECTED, REINSTALLED COVER AND PERFORMED CHECKS IAW THE AMM. THE ACFT WAS RELEASED FOR SERVICE.SDR MASA2016062912816Battery Pack · dischargedMULTIPLE EMERGENCY EXIT LIGHTS INOPERATIVE. R & R 2 BATTERY PACKS AND CHARGERS.SDR SWAA2016063053367Battery · failedEMERGENCY LIGHTS BATTERY FAILED CAPACITY CHECK AT LOCATION M01672. R & R BATTERY IAW AMM.SDR SWAA2016062953356Sign · missingMID CABIN EXIT SIGN MISSING. INSTALLED SIGN PER SIP.SDR SWAA2016062953355Sign · missingR2 DOOR EXIT SIGN MISSING. INSTALLED SIGN PER SIP.SDR SWAA2016063053350Lens · missingRT OVERWING EMERGENCY EXIT LOWER SIDE WALL IDENTIFIER LENS MISSING. INSTALLED LENS PER MM.SDR MASA2016062912813Battery · dischargedROW 14 EMERGENCY EXIT LIGHTS INOPERATIVE. CHARGED BATTERIES.SDR SWAA2016071553844Battery Pack · dischargedL2 EMERGENCY LIGHT INOPERATIVE. RECHARGED BATTERY PACK IAW AMM.SDR SWAA2016071553843Battery Pack · dischargedAFT GALLEY EMERGENCY EXIT SIGN LIGHT INOPERATIVE. RECHARGED BATTERY PACK IAW AMM.SDR SWAA2016071553842Battery Pack · dischargedLEFT EMERGENCY LIGHT INOPERATIVE AT ROW 22. RECHARGED BATTERY PACK IAW AMM.SDR SWAA2016071353762Lens · looseRIGHT EMERGENCY HATCH LIGHT LENS LOOSE. SECURED THE LENS IAW DWG.SDR ASOA2016062815035Charger · inoperativeEMERGENCY LIGHT ABOVE GALLEY INOPERATIVE, EXTERNAL EMERGENCY LIGHT BESIDE PAX DOOR INOPERATIVE, EXTERNAL EMERGENCY LIGHT LT SIDE AFT OVERWING INOPERATIVE. REMOVED AND REPLACED THE NR 1 EMERGENCY BATTERY PACK CHARGER ASSEMBLY IAW AMM 33-51-17-000-802-A02, & AMSDR DALA2016063005103Light · brokenROW 7ABC EMERGENCY SEAT LIGHT INOPERATIVE, REPAIRED BROKEN .SDR DALA2016062905049Lens · missingEXIT SIGN LENS MISSING ON WALL RT SIDE FWD OF WINGS. REPLACED LIGHT ASSY IAW AMM 33-50.SDR DALA2016062905043Lens · missingDOOR 2R EXIT LIGHT LENS COVER MISSING. REPLACE MISSING RED LENS AT MID LAV.SDR QXEA2016062800440Battery Pack · failedEMERGENCY BATTERY PACKS IN THE NR 2 POSITION FAIL THE 10 MINUTE TEST. REPLACED BATTERY PACK.SDR RAIA201606280001Inverter · inoperativeCOCKPIT EMERGENCY EXIT FLOODLIGHT INVERTER INOPERATIVE. R & R COCKPIT EMERGENCY LIGHT INVERTER IAW AMM 33-50-01. OPS CHECK GOOD.SDR SIMA20160628001Light · inoperativeMAIN DOOR EMERGENCY LIGHT INOPERATIVE. R & R MAIN PASSENGER DOOR EMERGENCY LIGHT IAW AMM 33-50-06-000-801. OPS CHECK GOOD.SDR MASA2016062812811Light · inoperativeFWD CEILING EMERGENCY FLOOD LIGHT INOPERATIVE. PLACED ON MEL.SDR AALA20160628006Light · inoperativeAIRCRAFT WAS NOT GROUNDED. EMERGENCY LIGHT AT SEAT 22D IS INOPERATIVE. R & R LIGHT ASSEMBLY IAW AMM 33-51-05. OPS CHECK NORMAL.SDR AALA201606299006Lens · brokenAIRCRAFT WAS NOT GROUNDED. EMERGENCY LIGHT LENS AT FIRST CLASS SEAT 1C BROKEN. R & R LIGHT ASSY AT SEAT 1C. OPS CHECK NORMAL.SDR SWAA2016062953325Sign · looseMID CABIN CEILING EMERGENCY EXIT SIGN LOOSE. SECURED SIGN PER AMM.SDR SWAA2016062953323Lens · missingRT OVERWING EMERGENCY EXIT SIGN UPPER LENS MISSING AT ROW 12. INSTALLED LENS PER AMM.SDR DALA2016062804986Battery Pack · dischargedDURING SERVICE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTS IN ROWS 15-19 OF THE CABIN AND THE AFT TAIL COMPARTMENT WERE INOPERATIVE. MAINTENANCE REPLACED THE BATTERY PACKS FOR THE NOTED LIGHTED AREAS AND THE OPS CHECK WAS GOOD.SDR SWAA2016062853294Lens · crackedLT EMERGENCY LIGHT LENS CRACKED AT ROW 16. R & R LENS IAW AMM.SDR SWAA2016062853293Lens · crackedRIGHT EMERGENCY LIGHT LENS CRACKED AT ROW 17. R & R LENS IAW AMM.SDR MASA2016062812810Battery · dischargedROW 13 EMERGENCY LIGHTS INOPERATIVE. CHARGED EMERGENCY BATTERIES.SDR REXA2016062801159Light · missingEMERGENCY FLOOR LIGHTING MISSING AT 13BA. INSTALLED EMERGENCY FLOOR LIGHTING AT 13BA IAW AMM 33-51-01.SDR SIMA20160627007Light · damagedLEFT EMERGENCY LIGHT STRIP JUST AFT OF EMERGENCY EXIT HAS SEVERAL STRESS CRACKS, AND CRACKED COMPLETELY IN THE MIDDLE. REMOVED AND REPLACED THE EMERGENCY LIGHT STRIP IAW AMM-33-51-01.SDR SWAA2016070553477Battery Pack · inoperativeAFT EMERGENCY LIGHT INOPERATIVE. R & R THE BATTERY PACK IAW AMM.SDR DALA2016062805040Sign · unsecureTHE EXIT SIGN ABOVE THE 2L DOOR HAS FALLEN OFF. REINSTALLED EXIT SIGN ABOVE 2L DOOR.SDR DALA2016062805028Light · inoperativeEXTERIOR EMERGENCY LIGHTS ARE INOPERATIVE AT R2 AND FORWARD OF AFT CARGO. MAINTENANCE RELAMPED AND REPLACED, FUSE M733. SYS OPS ARE NORMAL.SDR IPXA2016062805178Power Supply · inoperativeEMERGENCY POWER TEST FAILED, INOPERATIVE. R & R EMERGENCY POWER SUPPLY. OPS CK NORMAL REF AMM 33-51-01 EFF SOURCE IPC 33 51 01, EFF SOURCE IPC 33-51-10-01-005J.SDR ASAA2016062717188Lens · brokenR2 DOOR EXIT LIGHT BROKEN. ACFT GROUNDED. REGLUED COVER-REINSTALLED COVER REF AMM 33-51-11.SDR ASAA2016062717187Lens · missingF/A REPORTS EXIT LIGHT COVER IS MISSING ON WALL NEXT TO R2 DOOR. ACFT GROUNDED. REPLACED EXIT LIGHT COVER. ACFT OK FOR SERVICE.SDR SWAA2016062953346Light · inoperativeLT AFT FUSELAGE EMERGENCY LIGHT INOP. RELAMPED LIGHT PER MM.SDR VNAA2016062700030Sign · detachedMID CABIN AISLE EMERGENCY EXIT SIGN FELL OFF. MAINTENANCE INSPECTED, REINSTALLED EXIT SIGN AND PERFORMED CHECKS IAW THE AMM. THE ACFT WAS RELEASED FOR SERVICE.SDR AALA20160628002Battery · dischargedAIRCRAFT WAS NOT GROUNDED. SEAT MOUNTED EMERGENCY LIGHTS BETWEEN ROWS 33HJ AND 41HJ ARE INOPERATIVE. R & R EMERGENCY BATTERY AND CHARGER ASSEMBLIES IAW AMM 33-60-98. SYSTEM CHECKS NORMAL. ALSO AALA20160627008.SDR AALA20160627008Charger · inoperativeAIRCRAFT WAS NOT GROUNDED. SEAT MOUNTED EMERGENCY LIGHTS BETWEEN ROWS 33HJ AND 41HJ ARE INOPERATIVE. R & R EMERGENCY BATTERY AND CHARGER ASSEMBLIES IAW AMM 33-60-98. SYSTEM CHECKS NORMAL. ALSO AALA20160628002.SDR AALA20160627001Indicator · crackedAIRCRAFT WAS IN BASE MAINTENANCE. R3 DOOR AFT EXIT INDICATOR IS CRACKED. R & R EXIT INDICATOR IAW AMM 33-51-01. OPS TEST GOOD IAW ECO B1715AB-0004.SDR SWAA2016062753251Lens · missingAFT RT OVERWING EXIT SIGN LENS MISSING. R&R LENS ASSEMBLY PER MM.SDR AALA20160627004Battery · dischargedAIRCRAFT WAS NOT GROUNDED. EMERGENCY LIGHTS IN FORWARD ENTRANCE AREA ARE INOPERATIVE. R & R THE FORWARD EMERGENCY BATTERY ASSY IAW AMM 33-53-00. OPS CHECK GOOD.SDR AALA20160627003Battery Pack · dischargedAIRCRAFT WAS NOT GROUNDED. AFT EMERGENCY ESCAPE PATH LIGHTING IS INOPERATIVE. EMERGENCY PATH MARKING SYS FAILS DUAL FEED TEST IN AFT PORTION OF CABIN. R & R POWER SUPPLY AND BATTERY PACK AT FUSELAGE STA 1260 IAW AMM 33-60-98. OPS CHECK GOOD, ALSO, AALA2016SDR AALA20160627002Power Supply · inoperativeAIRCRAFT WAS NOT GROUNDED. AFT EMERGENCY ESCAPE PATH LIGHTING IS INOPERATIVE. EMERGENCY PATH MARKING SYS FAILS DUAL FEED TEST IN AFT PORTION OF CABIN. R & R POWER SUPPLY AND BATTERY PACK AT FUSELAGE STA 1260 IAW AMM 33-60-98. OPS CHECK GOOD. ALSO AALA2016SDR MASA2016062712807Light · inoperativeCABIN EXIT SIGN 13A, 1 BULB INOPERATIVE. PLACED ON MEL.SDR MASA2016062712806Light · inoperativePASSENGER ENTRY/EXIT SIGN 1 BULB INOPERATIVE. PLACED ON MEL.SDR MASA2016062712804Battery · dischargedEMERGENCY LIGHTS WOULD NOT STAY ON. CHARGED BATTERIES.SDR CALA2016081195626Battery Pack · no testEMERGENCY LIGHT TEST FAILED WITH EPSU BATTERY FWD LEFT FAULT. REPLACED EPSU BATTERY, OPS CHECKED NORMAL.SDR FDEA201606262147Light · inoperative2 OVERHEAD EMERGENCY LIGHTS INOPERATIVE. OVERHEAD EMERGENCY LIGHTS RELAMPED IAW MM 33-50-00-02.
Back to JASC 3350