JASC 3350
Service difficulty reports · 225,735
Reports filed under 3350 · Emergency Lighting, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3350' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3350' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2025061904618Charger · inoperative(LOG 7392513) EMER LIGHTS INOP DURING OP TEST AT 1-5DC. R/R BATT CHARGER AND BATT REF B737N AMM 33-51. OPS TEST GOOD.SDR ASAA2025061458741Power Supply · inoperativeWHILE ACCOMPLISHING T/C 78233001 FOUND L-2 DOOR INTERIOR AND EXTERIOR LIGHTS FIALED BOTH BATTERY LIFE TESTS. GROUNDED - YES. REMOVED AND REPLACED M1673 EMERGANC LIGHT BATTERY PACK REF 33-51-06-960-805. NO OTHER DISCREPANCIES NOTED.SDR CALA2025061805657Battery Pack · no testDURING EMER LIGHT SYS TEST, EPSU BATTERY AFT L FAULT REPLACED AFT EPSU (13WL) BATTERY REF AMM 33-51-38/401. BATTERY FAULT CLEARED. BITE RETURNED L AFT EPSU INT LOAD FAULT. DURING TEST, EXIT LIGHT 52WL DID NOT FLICKER. EPSU (13WL) AND AFT CENTER AISLE OVERHEAD SDR ASAA2025061458743Cover · detachedEXIT ROW EMERGENCY LIGHT COVER AT SEAT 16A FELL OFF. GROUNDED - YES. SECURED EXIT ROW EMERGENCY LIGHT COVER AT 16A PER AMM 33-51-01-960-802 PERFORMED EMERGENCY LIGHTS OPS TEST PER AMM 33-51-00-710-801 OPS CHECK OK.SDR AALA202506171899Light · no testAIRCRAFT WAS NOT GROUNDED: SEAT 8C WHITE EMERGENCY EXIT LIGHT IS INOPERATIVE. REPLACED LIGHT AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 33-51-08.SDR DALA2025061604544Lamp · inoperativeRIGHT WING EMERGENCY OVERWING LIGHT INOPERATIVE. RELAMPED RT FWD EMERGANCY OVERWING LIGHT IAW AMM 33-51.SDR DALA2025061604543Light · inoperativeLEFT WING EMERGENCY OVERWING LIGHT INOPERATIVE. T/S PER A319 TSM 33-51-00-810-809-A. SYSTEM OPS NORMAL.SDR SWAA2025061681776Sign · detachedEXIT SIGN MID CABIN FELL OFF. INSTALLED COVER PER AMM CH 33-51-00.SDR SWAA2025061681779Lens · missingRIGHT EMERGENCY UPPER EXIT SIGN LENS/COVER MISSING<[01] RESCURED LENS COVER PER SIP.SDR SWAA2025061681701Battery Pack · inoperativeVARIOUS EMERGENCY LIGHTS INOP<[01] FOUND BATTERY PACK AT LOCATION M1676 TO BE AT FAULT REPLACED BATTERY WITH NEW. OPS CHECK GOOD. WORK DONE PER AMM 33-51-06.SDR SWAA2025061682003Lens · detachedCENTER AISLE EXIT SIGN COVER FELL OFF. REINSTALLED LEN REF AMM 33-51-01.SDR SWAA2025061681718Battery Pack · inoperativeLH FWD 3 PAX AISLE EMERGENCY LIGHTS INOP. REMOVED AND REPLACED EMER LIGHT POWER SUPPLY BATTERY PACK FOR FWD LEFT AISLE LIGHTS (M2335) PER AMM 33-51-06. OPS TEST GOOD.SDR AALA202506167976Battery · no testAIRCRAFT WAS NOT GROUNDED: BATTERY FAULT FOR EMERGENCY POWER SUPPLY UNIT 17WL DISPLAYED DURING SYSTEM TEST. REPLACED BATTERY FOR EMERGENCY POWER SUPPLY UNIT 17WL AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 33-51-38.SDR AALA202506168065Battery · no testAIRCRAFT WAS NOT GROUNDED: BATTERY FAULT FOR EMERGENCY POWER SUPPLY UNIT 11WL DISPLAYED DURING SYSTEM TEST. REPLACED BATTERY FOR EMERGENCY POWER SUPPLY UNIT 11WL AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 33-51-38.SDR CALA2025061605569Bulb · damagedEMERGENCY LIGHTING SYSTEM OPERATIONAL CHECK {B737-33-3-0235} - EXTERIOR EMERGENCY LITE INOP AFT OF DOOR 2L RELAMPED, GRD OPS NORM PARTS USED: 00-0594-3-2616,QTY :1SDR CALA2025061605566Battery Pack · no testEMERGENCY LIGHTING SYSTEM OPERATIONAL CHECK {B737-33-3-0235} - FOUND SEATS 15 ABC, 20ABC, AND 21ABC AISLE SIDE RED EMERGENCY TRACKING LIGHTS INOP DURING TEST. REPLACED M1694 BATTERY PACK AND POWER SUPPLY IAW AMM 33-51-06. EMERGENCY LIGHTS TEST GOOD.SDR CALA2025061605565Battery Pack · faultedEMERGENCY LIGHTING SYSTEM OPERATIONAL CHECK {B737-33-3-0235} - FOUND INTERIOR AND EXTERIOR EMERGENCY EXIT LIGHTS ON THE R1 DOOR INOP. REMOVED AND REPLACED BATTERY PACK REF AMM 33-51-06-960-805. OPS CHECK GOOD. OK TO CONTINUE.PARTS USED: 99-3351-3-0015,QTY :1SDR UIEA2025061600777Battery · no testFOUND U/D EMERGENCY LIGHT POWER SUPPLY (M5933) FUNCTION FAIL.(<P>1. REPLACED EMERGENCY LIGHT POWER SUPPLY (M5933) IAW AMM 33-51-04-002-009-001 & AMM 33-51-04-402-012-001 REV 113. 2. REPLACED EMERGENCY POWER SUPPLY BATTERY (M5933) IAW AMM 33-51-04-902-001-001 RSDR UIEA2025061600778Light · inoperativeFOUND ZONE E CREW REST EMERGENCY LIGHT ASSY (M6916) INOP.(<P>1. REPLACED ZONE E CREW REST EMERGENCY LIGHT ASSY (M6916) IAW AMM 33-51-07-002-009 & AMM 33-51-07-402-015 REV 113. 2. PERFORMED <SPAN>ZONE E CREW REST EMERGENCY LIGHT ASSY (M6916) INSTALLATION TEST ISDR UIEA2025061600779Light · inoperativeFOUND DR JL EMERGENCY EXIT SIGN (M2995) LIGHT INOP.(<P>1. REPLACED DR JL EMERGENCY EXIT SIGN (M2995) LIGHT ASSY IAW AIPC 33-51-12-01A REV 89 & WDM 33-51-63 REV 70. 2. PERFORMED EMERGENCY LIGHT OPERATIONAL TEST IAW AMM 33-51-00-715-10J REV 113. THE RESULT WAS SSDR UIEA2025061600780Battery · inoperativeFOUND U/D EMERGENCY LIGHT POWER SUPPLY BATTERY (M5932) FUNCTION FAIL.(<P>1. REPLACED U/D EMERGENCY LIGHT BATTERY (M5932) IAW AMM 33-51-04-902-001-001 REV 113. 2. REPLACED EMERGENCY POWER SUPPLY BATTERY (M5933) IAW AMM 33-51-04-902-001-001 REV 113. 3. PERFORMEDSDR UIEA2025061600781Battery · inoperativeFOUND ZONE D CREW REST EMERGENCY LIGHT POWER SUPPLY BATTERY (M2927) FUNCTION FAIL.(<P>1. REPLACED ZONE D CREW REST EMERGENCY LIGHT POWER SUPPLY BATTERY (M2927) IAW AMM 33-51-04-902-001-001 REV 113. 2. PERFORMED ZONE E CREW REST EMERGENCY LIGHT POWER SUPPLY BATSDR UIEA2025061600782Battery · failedFOUND DR 3L EMERGENCY LIGHT POWER SUPPLY BATTERY (M2919) FUNCTION FAIL.(<P>1. REPLACED DR 3L EMERGENCY LIGHT POWER SUPPLY (M2919) IAW AMM 33-51-04-002-009-001 & AMM 33-51-04-402-012-001 REV 113. 2. PERFORMED EMERGENCY LIGHT POWER SUPPLY INSTALLATION TEST IAW ASDR AALA202506165659Sign · inoperativeAIRCRAFT WAS NOT GROUNDED: FOUND L3 DOOR AFT EMERGENCY EXIT SIGN INOP. (OPEN)SDR AALA202506166927Power Supply · inoperativeAIRCRAFT WAS NOT GROUNDED: ROW 24-25 EMERGENCY PATHWAY LIGHTS ON SEAT INOP. MAINTENANCE REPLACED POWER SUPPLY UNIT PER AMM 25-21-38. BOTH ROWS EMERGENCY PATHWAY LIGHTS 24 AND 25, OPS CHECK GOOD.SDR SCNA20250616212Light · inoperativeL1 DOOR EMERGENCY EXIT LIGHT ON FUESLAGE IS INOP. RELAMPED EMERGENCY LIGHT LI DOOR AREA REF AMM 33-51-00.SDR SCNA20250616211Battery Pack · inoperativeFOUND EMERGENCY EXIT SIGNS AND LEFT ESCAPE SLIDE LIGHT IN FWD GALLEY INOP. - REMOVED AND REPLACED BATTERY PACK AT M1675 POWER SUPPLY. EMERGENCY LIGHS OPS CHECK GOOD.REF AMM 33-51-06.SDR 3J7R2025061400001Light · dimEXTERIOR EMERGENCY EXIT LIGHT NEAR MAIN CABIN DOOR VERY DIM. ALSO DIM WHEN BEING USED AS PAX SAFETY LIGHT.SDR SWAA2025072181611Lens · brokenBROKEN EXIT SIGN LENS ON AFT CENTER CEILING 2EA. REPLACED EXIT SIGN LENS ON AFT CENTER CEILING 2EA IAW AMM 33-51-01-960-802 STEP 3.C(10).SDR AALA202506180426Power Supply · no testAIRCRAFT IN BASE MAINTENANCE: DONT PASS EPSU TEST 10WL PN:3214-54-10 SN:006421 IN FWD GALLEY AREA. PERFORMED TROUBLE SHOOTING IAW TSM 33-51-00-810-801-A STEP 1 THRU 4.B.(1). MAINTENANCE REPLACED EMERGENCY POWER SUPPLY UNIT FIN 10WL IAW AMM33-51-38-000-001-A, ASDR AALA202506186856Power Supply · no testAIRCRAFT IN BASE MAINTENANCE: DONT PASS EPSU TEST 13WL PN:3214-54-10 SN:5880 IN AFT GALLEY AREA. PERFORMED TROUBLE SHOOTING IAW TSM 33-51-00-810-801-A STEP 1 THRU STEP 3 ANDSTEP 4.B.4. MAINTENANCE REPLACED EMERGENCY POWER SUPPLY UNIT FIN 13WL IAWA MM 33-51-38-SDR CALA2025061705598Light · no discrepancyREMOVED RH EMERGENCY EXIT PATH TO FOM IN REF TO AMM TASK 52-21-11-000-001-A. FOLLOWED RSC IN REF TO GMM 02-30-25. INSTALLED RH AFT OVERWING HATCH IN REF TO AMM TASK 52-21-11-400-001-A.SDR SWAA2025061781447Fuse · openEMERGENCY EXIT LIGHTS L1365; L751 ASSOCIATED WITH BATTERY PACK M1668 ARE INOPERATIVE. REPLACED FUSE AT POWER SUPPLY M1668 AND PERFORMED GOOD TEST IAW AMM 33-51-06-960-804 AND WDM 33-51-13.SDR SWAA2025061781446Battery Pack · inoperativeALL EMERGENCY EXIT LIGHTS ASSOCIATED WITH M1670 BATTERY PACK ARE INOP. REMOVED AND REPLACED BATTERY PACK M1670 AND PERFORMED GOOD INSTALLATION TEST; PER AMM 33-51-06-960-805.SDR SWAA2025061781445Fuse · openEMERGENCY LIGHT L1365; L751 & L1605 ASSOCIATED WITH M1669 BATTERY PACK ARE INOPERATIVE. REPLACED FUSE AT POWER SUPPLY M1669 AND PERFORMED GOOD TEST IAW AMM 33-51-06-960-804 AND WDM 33-51-13.SDR SWAA2025061781240Battery Pack · inoperativeALL ASSOCIATED LIGHTS INOP WITH M1674 EMERGENCY BATTERY PACK. REMOVED AND REPLACED M1674 EMERGENCY BATTERY PACK AND PERFORMED GOOD OPERATIONAL TEST IAW AMM 33-51-06-960-805.SDR DALA2025061704569Light · inoperativeAFT LEFT DOOR EXTERNAL EMERGENCY LIGHT INOP. REMOVED AND REPLACED AFT LEFT DOOR EXTERNAL EMERGENCY LIGHT PER A220 AMP 33-55. OPS CHECK GOOD. (LP# 7510477)SDR ASAA2025061358735Cover · brokenROW 17F EXIT SIGN COVER BROKEN. GROUNDED - YES. INSTALLED NEW COVER FOR EXIT SIGN FOR ROW 17F REF AMM 33-51-01.SDR SWAA2025061681478Cover · missingRIGHT EMERGENCY EXIT LIGHT COVER MISSING<[01] INSTALLED LIGHT COVER PER AMM 33-51-01SDR SWAA2025061681167Light · contaminatedPASSENGER CABIN ROW 1DEF CETER AISLE PHOTOLUMINESCENT STRIP HAS MOISTURE IN IT. R&R PASSENGER CABIN ROW 1DEF CENTER AISLE PHOTOLUMINESCENT STRIP IAW AMM 33-51-15.SDR SWAA2025061681750Light · detachedCTR AISLE EMER EXIT LIGHT ASSY FELL DOWN. RESECURED AISLE OVHD EMER EXIT LIGHT ASSY PER AMM 33-51-03.SDR SWAA2025061681400Lens · missingEMERGENCY LIGHT LENS FO SIDE CENTER CABIN MISSING. INSTALLED MISSING LENS PER AMM 33-51-01.SDR AALA202506164134Battery Pack · inoperativeAIRCRAFT IN BASE MAINTENANCE: ** DR 1R EMER BATTERY PACK (M33094) POWER LOW & WONT CHARGE UP**. DOOR 1R EMERG BATTERY PACK ASSY (M33094) REPLACED AND INSTALLATION TEST RESULT NORMAL. AMM 33-51-06 REV. 246, DATE 24 MAY 2025.SDR DXTA2025061603887Light · inoperativeOVER WING EMERGENCY EXIT ESCAPE LIGHT IS INOP. COMPLIED WITH NJ MEL PROCEDURES. CORRECTIVE ACTION: REPLACED OVER-WING EMERGENCY EXIT LIGHT IAW CE-680A AMM 33-50-20 OPS CHECK GOODSDR SIMA20250613001Battery · inoperativeFORWARD SERVICE DOOR EMERGENCY EXIT LIGHT INOP FOUND EMERGENCY-LIGHT POWER UNIT INOP ON FORWARD SERVICE DOOR EMERGENCY EXIT LIGHT. RAR EMERGENCY-LIGHT POWER UNIT IAW AMM 33-50-01, OPC GOODSDR AALA202506133140Battery · no testAIRCRAFT WAS NOT GROUNDED: BATTERY FAULT DISPLAYED FOR EMERGENCY POWER SUPPLY UNIT 13WL DURING SYSTEM TEST, REPLACED EMERGENCY POWER SUPPLY UNIT 13WL (AALA202506138169) AND BATTERY (AALA202506133140) PER AMM 33-51-38. A SATISFACTORY OPERATIONAL CHECK OF THE EMSDR AALA202506138169Power Supply · no testAIRCRAFT WAS NOT GROUNDED: BATTERY FAULT DISPLAYED FOR EMERGENCY POWER SUPPLY UNIT 13WL DURING SYSTEM TEST, REPLACED EMERGENCY POWER SUPPLY UNIT 13WL (AALA202506138169) AND BATTERY (AALA202506133140) PER AMM 33-51-38. A SATISFACTORY OPERATIONAL CHECK OF THE EMSDR AALA202506139167Power Supply · faultyAIRCRAFT WAS GROUNDED: EPSU FWD LEFT FAULT BATT MESSAGE WHILE ACCOMPLISHING OPERATIONAL TEST OF THE EMERGENCY LIGHTS. MAINTENANCE REPLACED THE EPSU BATTERIES FOR THE FWD LEFT EPSU IAW AMM 33-51-38.SDR AALA202506132159Power Supply · faultyAIRCRAFT WAS GROUNDED: EPSU AFT LEFT FAULT BATT MESSAGE WHILE ACCOMPLISHING OPERATIONAL TEST OF THE EMERGENCY LIGHTS. MAINTENANCE REPLACED THE EPSU BATTERY FOR THE AFT LEFT EPSU IAW AMM 33-51-38.SDR SWAA2025061781247Battery Pack · inoperativeEMERGENCY LIGHTS INOPERATIVE RH STOW BIN POSITION 8;11 AND 13. REMOVED AND REPLACED RH EMERGENCY LIGHT BATTERY PACK IAW AMM 33-51-06-960-805. OPS CHECK IS GOOD.
Back to JASC 3350