JASC 3350
Service difficulty reports · 225,786
Reports filed under 3350 · Emergency Lighting, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3350' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3350' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2024101702671Power Supply · inoperative(MULT 33-3-0004) EMERGENCY LT BATTERY PACK M1672 LOW VOLTAGE TRANSCRIBED FROM HAECO GSO NR 9280050 REMOVED AND REPLACED M1672 POWER SUPPLY I.A.W B737-800 AMM 33-51-06-960-806. OPS TEST CHECKS GOOD I.A.W B737-800 AMM 33-51-06-960-805;STEP 5.E.(3).SDR CALA2024101702670Battery Pack · dischargedM/D R2 DOOR EMERGENCY LIGHT BATTERY PACK M33098 FOUND LOW CAPACI TY DURING CAPACITY CHECK REFER HAECO NON-ROUTINE LOG PAGE:949659 1,ORIGINATED BY EMP:V903218,SPEC NO.B777-33-3-7019. PERFORMED BY EMP:V903218,REPLACED THE M/D R2 DOOR M33098 EMERGEN CY LIGHT BATTSDR CALA2024101702669Battery Pack · dischargedR4 DOOR M33409 BATTERY PACK FOUND LOW CAPACITY DURING TEST REFER HAECO NON-ROUTINE LOG PAGE:9496593,ORIGINATED BY EMP:V903218,SPE C NO.B777-33-3-7019. PERFORMED BY EMP:V903218,REPLACED R4 DOOR M33409 BATTERY PACK AN D C/O NEW BATTERY PACK TEST. THE RESULT NORMSDR BJNA202410170001Charger · inoperativeFOUND M1671 BATTERY POWER SUPPLY INOP. UNABLE TO CHARGE BATTERY. REMOVED & REPLACED POWER SUPPLY IAW AMM 33-51-06-960-806. OPS CHECK GOOD.SDR AALA202410160518Lamp · inoperativeAIRCRAFT IN BASE MAINTENANCE: EXTERIOR EMERGENCY LIGHT FOR 4L DOOR IS INOPERATIVE. RELAMPED EXTERIOR EMERGENCY SLIDE LIGHT AT AFT 4L DOOR. OPERTIONAL CHECK GOOD. PER AMM 33-51-04.SDR IPXA2024101652222Battery Pack · inoperativeFOUND THE EMERGENCY LIGHTING BATTERY PACK M5168 NO FUNCTION LOCATED ON THE UPPER DECK. (REPLACE) OK TO WORKSDR REXA2024101600881Lamp · inoperativeAFT RH EXTERIOR EMERGENCY LIGHT INOP RE-LAMPED AFT RH EXTERIOR EMERGENCY LIGHT IAW CRJ900 AMM 33-51-15 OPS CHECK GOOD.SDR SWAA2024112548644Cover · missingMISSING COVER PLATE ON CENTER EMERGENCY LIGHT ON PASSENGER CABIN (2EA) 2024-645427<[01] INSTALLED COVER PLATE ON CENTER EMERGENCY LIGHT ON PASSENGER CABIN (2EA) IAW KOITO MANUFACTURING CMM 33-24-03 REV. 24 PAGE 7008 STEP 8.A.14.(17) AND PAGE 10032 ITEM 380.;[0SDR SWAA2024102148538Battery Pack · inoperativeEMERGENCY EXIT LIGHT NEXT TO AFT ENTRY DOOR INOP.<[01] 01 - REMOVED AND REPLACED PER [AMM 33-51-06-960-805-NG (POWER SUPPLY - BATTERY PACK REPLACEMENT - PERMANENT)]<BR>REFF. JOB CARD [TTG8Q00WEU3H]. FOR PART.SDR SWAA2024102148531Battery Pack · inoperativeEMERGENCY EXIT LIGHT ABOVE AFT SERVICE DOOR INOP.<[01] 01 - REMOVED AND REPLACED PER [AMM 33-51-06-960-805-NG (POWER SUPPLY - BATTERY PACK REPLACEMENT - PERMANENT)]SDR SWAA2024102148919Battery Pack · inoperativeEMERGENCY LIGHTS ASSOCIATED WITH BATTERY PACK M1673 INOP<[01] REMOVED EMERGENCY BATTERY PACK M1673 AND INSTALLED SERVICEABLE BATTERY PACK AND PERFORMED GOOD INSTALLATION TEST PER AMM 33-51-06-960-805;[02] VERIFIED CORRECTIVE ACTION 1SDR SWAA2024102148920Battery Pack · inoperativeEMERGENCY LIGHTS ASSOCIATED WITH BATTERY PACK M2335 INOP<[01] REMOVED EMERGENCY LIGHT BATTERY PACK M2335 AND INSTALLED SERVICEABLE BATTERY PACK AND PERFORMED GOOD INSTALLATION TEST PER AMM 33-51-06-960-805;[02] VERIFIED CORRECTIVE ACTION 1;[03] UPDATED PARTS RSDR SWAA2024102148666Battery Pack · failedAFT R/H EMERGENCY LIGHTING BATTERY PACK FAILED CAPACITY CHECK.<[01] REMOVED AND REPLACED BATTERY PACK PER M/M 33-51-06.SDR SWAA2024102148665Battery Pack · failedAFT L/H EMERGENCY LIGHTING BATTERY PACK FAILED CAPACITY CHECK.<[01] REMOVED AND REPLACED BATTERY PACK PER M/M 33-51-06.SDR DALA2024101810208Battery · no testSHIP 184 FOUND MULTIPLE ROWS AFT RIGHT INOP EMERGENCY LIGHTS. CORRECTIVE ACTION: R/R BATTERY POWER SUPPLY M9010 PER B767 AMM 33-51. OPS CHK GOOD, ALL LIGHTS ON. (4000110)SDR YENA2024101801374Battery · no testFLT#2752, SJU-TPA. 'EMERG LIGHT BATTERY 14WL FAILED TEST; REMOVED AND REPLACED EMER LIGHT BATTERY 14WL IAW AMM 33-51-38.'SDR YENA2024101801373Battery · failedFLT#2752, SJU-TPA. 'EMERG LIGHT BATTERY 11WL FAILED TEST; REMOVED AND REPLACED EMER LIGHT BATTERY 11WL IAW AMM 33-51-38.'SDR AALA202410166417Light · unsecureAIRCRAFT WAS NOT GROUNDED: EMERGENCY LIGHT AT AFT GALLEY UNSECURE. SECURED THE AFT GALLEY EMERGENCY LIGHT ASSEMBLY. OPERATIONAL CHECK OF THE LIGHT IS NORMAL. PER AMM 33-51-01.SDR AALA202410162996Light · inoperativeAIRCRAFT WAS GROUNDED: R2 DOOR EMERGENCY EXIT LIGHT IS OUT. REMOVE AND REPLACED EEL ASSEMBLY. PER AMM 33-51-01.SDR WX0A2024101632200Battery Pack · no test(AIRCRAFT GROUNDED) FWD EPSU BATTERY (10WL) REQUIRES REPLACEMENT FOR CAPACITY CHECK / REMOVED AND REPLACED EPSU (10WL), OPS CHECK GOOD REF AMM 33-51-38-400-002-A AND 33-51-38-000-002-A."SDR DALA2024101610142Battery Pack · inoperativeSHIP 685 ROWS 18-22 SEATS EMERGENCY LIGHTS INOP. CORRECTIVE ACTION: REMOVED & REPLACED EMERGENCY LIGHT BATTERY PACK IAW B757 AMM 33- 51-07. OPS CHECK GOOD. (6369453)SDR AALA202410163865Battery · failedAIRCRAFT WAS NOT GROUNDED: WHILE PERFORMING PS CK OF THE CABIN, DURING EPSU TEST,10WL BATTERY FAILED. REPLACED EPSU BATTERY PER AMM 33-51-38, OPS CK GOOD.SDR CALA2024101602662Battery Pack · no testEMERGENCY LIGHT BATTERY (M1673) IS INOP AT L/H OVERHEAD AFT GALLEY.T/S AND FOUND LOOSE CONNECTION AT EMERGENCY LIGHTS BATTERY PACK CHARGER (M1673), RESEATED CONNECTOR IAW WDM 33-51-13-7. OPS CHEC K GOOD IAW B737 AMM 33-51-06-960-805 PAR 4 STEP E.6. REMOVED/REPSDR CALA2024101602653Battery Pack · inoperative(MULT-33-3-9200) EMERGENCY LIGHT BATTERY PACK (M1672) IS INOP AT R/H OVERHEAD AFT GALLEY, SDR IS REQUIRED.REPLACED M1672 BATTERY PACK IAW AMM 33-51-06-960-805, PERFORMED GOOD OPS CHECK IAW AMM 33-51-00-710-801, SN 232365 INSTALLED, SN REMOVED 408704.SDR AALA202410168033Power Supply · no testAIRCRAFT WAS NOT GROUNDED: EMERGENCY POWER SUPPLY UNIT 10WL BATTERY FAILED CID 1 BITE TEST. REPLACED EMERGENCY POWER SUPPLY UNIT 10WL PER AMM 33-51-38 AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.SDR AALA202410169896Power Supply · no testAIRCRAFT WAS NOT GROUNDED: EMERGENCY POWER SUPPLY UNIT 11WL BATTERY FAILED CID 1 BITE TEST. REPLACED EMERGENCY POWER SUPPLY UNIT 11WL PER AMM 33-51-38 AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.SDR AALA202410168870Battery · no testAIRCRAFT WAS NOT GROUNDED: EMERGENCY POWER SUPPLY UNIT 13WL DISPLAYED A FAULT MESSAGE DURING CIDS 1 SYSTEM TEST. REPLACED EMERGENCY POWER SUPPLY UNIT 13WL BATTERY AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 33-51-38.SDR 4VAA20241015006Power Supply · inoperativeEMERGENCY LIGHTING POWER SUPPLY BATTERY 17LN FAILED FUNCTION TEST. REPLACED WITH SERVICEABLE UNIT.SDR REXA2024101500877Lamp · inoperativeEMERGENCY LIGHT INOP ROW 3DC RELAMP EMERGENCY LIGHT PER AMM 33-51-09 P/N ON/OFF: 1317SDR SWAA2024112648287Light · brokenBROKEN PHOTOLUMINESCENT FLOOR PROXIMITY LIGHTING AT PASSENGER CABIN (10 EA). REPLACED PHOTOLUMINESCENT FLOOR PROXIMITY LIGHTING AT PASSENGER CABIN (10 EA) IAW B737-700 AMM 33-51-15-400-802;[02] REPLACED PHOTOLUMINESCENT FLOOR PROXIMITY LIGHTING AT PASSENGER SDR SWAA2024112548494Light · delaminatedDELAMINATED PHOTOLUMINESCENT STRIP ALONG PAX CABIN (10EA) 2024-645380<[01] REPLACED PHOTOLUMINESCENT STRIP ALONG PAX CABIN (10E) IAW B737-800 AMM 33-51-15-400-802 STEP 1.A.THRU E. EXCEPT E.(1) AND DWG 417A5775 REV-;[02] REPLACED PHOTOLUMINESCENT STRIP ALONG PASDR SWAA2024110548559Light · damagedG1 GALLEY EMERGENCY EXIT INDICATOR LIGHT ASSY DAMAGED<[01] REMOVED AND REPLACED G1 GALLEY EMERGENCY EXIT INDICATOR LIGHT PER AMM 33-51-01-960-802.;[02] REMOVED AND REPLACED G1 GALLEY EMERGENCY EXIT INDICATOR LIGHT ASSY PER AMM 33-51-01-960-802 STEP 3.C.(5); (1SDR AALA202410229698Battery · faultedAIRCRAFT IN BASE MAINTENANCE: EMERGENCY POWER SUPPLY UNIT 14WL FAULT MESSAGE DISPLAYED DURING SYSTEM TEST. REPLACED EMERGENCY POWER SUPPLY UNIT 14WL BATTERY AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 33-51-38.SDR DALA2024102010216Battery · inoperativeSHIP 3244 DISC: CABIN OVERWING EXIT DOORS LOWER RIGHT EMERGENCY LIGHTS OUT. C/A: REFERENCED A-320 ASM 33-51-02. REPLACED EPSU 12WL BATTERY, NO HELP. REINSTALLED ORIGINAL BATTERY. SWAPPED EPSU 12WL WITH KNOWN GOOD UNIT, BOTH RIGHT LOWER SIGNS ILLUMINATED. NEEDSSDR ASAA2024101453185Lamp · inoperativeFOUND LH FWD OVERWING EXTERIOR EMERGENCY LIGHT INOP WHILE PERFORMING TC 33-010-00. GROUNDED - YES. RELAMPED REF AMM 33-51-04. OPS NML. LENS ASSY HAS DAMAGED SCREW, REQ'S REPLACEMENT. INSTALLED SERVICEABLE SCREW REF AMM 33-51-04.SDR ASAA2024101453166Lens · missingEXIT LIGHT / PLACARD NEXT TO 16F - LOWER LEFT NEXT TO DOOR - MISSING. GROUNDED - YES. REPLACED / REINSTALL EXIT LIGHT PLACARD COVER ROW 16F PER AMM 33-51-01-960-002 OPS TEST OK.SDR ASAA2024101453164Lamp · inoperativeRH FWD OVERWING EMERGENCY EXTERIOR LIGHT INOP. GROUNDED - YES. REMOVED & REPLACED RH FWD OVERWING EMERGENCY EXTERIOR LIGHTIAW AMM 33-51-04. OPS CHECK GOOD.SDR SWAA2024101748765Cover · missingCENTER AISLE FORWARD EXIT LOCATOR SIGN MISSING<[01] INSTALLED MISSING LENSE COVER PER SIPSDR SWAA2024101748763Light · detachedLH EXIT ROW EMERGENCY LIGHT WILL NOT STAY ATTACHED TO SIDEWALL<[01] RESECURED AND OPS CHK LH EXIT ROW EMERGENCY LIGHT PER AMM 33-51-01SDR SWAA2024101748478Cover · detachedEMERGENCY EXIT ISLE LIGHT LENS COVER DETACHED ROW 19 RIGHT EMERGENCY LIGHT LENS COVER DETACHED ROW 19 RIGHT<[01] APPLIED TAPE AND SECURED LENS COVER. ITEM REMAINS ON MEL.;[02] WORKING MEL 25-10-01 SP-1B EMERGENCY EXIT AISLE LIGHT LENS COVER DETACHED ROW FO SIDSDR DALA2024101710157Power Supply · no testDURING SVC CHECK FOUND CABIN EMER EXIT LT DISPATCH MSG. R/R EPSU C10WL1 PER A350 AMM 33-51. OPS CK GOOD. MEL & PLACARD REMOVED. (LP# 6412865)SDR ASAA2024101453165Cover · detachedDURING PRE CHECK FOUND ROW 17 L/H EMERGENCY EXIT SIGN COVER OFF. GROUNDED - YES. REINSTALLED ROW 17 L/H EMERGENCY EXIT SIGN COVER PER AMM 33-51-01-960-802. OPS TEST OK.SDR FDEA202410141512Power Supply · failedDURING F/O INSPECTION, EMERGENCY LIGHT CHECK FAILED. ALL 3 LIGHTS AROUND ENTRY 1L AND THE THREE CLOSEST CEILING LIGHTS TO ENTRY 1L ARE NOT ILLUMINATING. REMOVED AND REPLCAED L1 EMERGENCY LIGHTS POWER SUPPLY IAW FX B777 AMM 33-51-0SDR AALA202410160712Power Supply · faultedAIRCRAFT WAS NOT GROUNDED: AFT LH EPSU FAULT. MAINTENANCE REPLACED AFT LH EPSU IAW AMM 33-51-38.SDR AALA202410156524Light · inoperativeAIRCRAFT WAS NOT GROUNDED: 18 ABC EMERGENCY LIGHTS INOPERATIVE. REPLACED SEAT MOUNTED EMERGENCY LIGHT AT SEAT 18 ABC.SDR AALA202410151394Light · inoperativeAIRCRAFT WAS NOT GROUNDED: 25 ABC EMERGENCY LIGHTS INOPERATIVE. REPLACED SEAT MOUNTED EMERGENCY LIGHT AT SEAT 25 ABC.SDR AALA202410156080Light · inoperativeAIRCRAFT WAS NOT GROUNDED: 24 ABC EMERGENCY LIGHTS INOPERATIVE. REPLACED SEAT MOUNTED EMERGENCY LIGHT AT SEAT 24 ABC.SDR IPXA2024101525778Battery Pack · inoperativeEMERGENCY LIGHT SYSTEM WAS INOP R&R BATTERY PACK IAW AMM 33-51-07/201. OPS CHECK GOOD. OK FOR SERVICE.SDR AALA202410148167Battery · fault messageAIRCRAFT WAS NOT GROUNDED: EMERGENCY POWER SUPPLY UNIT FAULT 11LW. DURING COMPLIANCE WITH PS CHECK JOB CARD 26L00005005. REPLACED BATTERY.SDR CALA2024101400826Fuse · blownEMERGENCY LIGHTING SYSTEM OPERATIONAL CHECK {B737-33-3-0235} - RH AFT OVERWING ESCAPE LIGHT AND OVERWING ESCAPE GROUND ILLUMINATION LIGHT INOP RELAMPED BOTH LIGHTS REF AMM 33-51-04-960-801. STILL INOP. REPLACED BATTERY PACK REF WDM 33-51-13-5 AND AMM 33-51-06
Back to JASC 3350