JASC 3350
Service difficulty reports · 225,786
Reports filed under 3350 · Emergency Lighting, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3350' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3350' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 3J7R2024031400001Battery · dischargedDURING MXC NOTED ALL EMERGENCY LIGHTS POWERED BY BATTERY PACK #3 DO NOT ILLUMINATE WITH BATTERY PACK POWERSDR DXTA2024031411198Battery Pack · inoperativeALL EMER LIGHTS ON WHEN EMER LIGHT SWITCH IN ARM POSITION. REPLACED BOTH #1 AND #2 BATTERY PACKS DUE TO NOT TURNING OFF WITH SWITCH I NTHE ARM POSITION. OPS CHECKED GOOD IAW AMM 33-52-01.SDR I5EA2024040400002Charger · no testR-1 DOOR EMERGENCY SLIDE EXTERIOR LIGHT INOP. REPLACED EMERGENCY LIGHT BATTERY CHARGER IAW B737-400 AMM 31-51-51.SDR I5EA2024040400001Charger · no testL-1 DOOR EMERGENCY SLIDE EXTERIOR LIGHT INOP. REPLACED EMERGENCY LIGHT BATTERY CHARGER IAW B737-400 AMM 31-51-51.SDR DALA2024031903437Light · inoperativeSHIP 6709 EMERGENCY SEAT MOUNTED LIGHTING DAMAGED / INOP / LOCATIONS:27D. CORRECTIVE ACTION: REPLACED 27D CART BUMPER PER B757 CMM 25-21-52. OPS CHECK GOOD (0243681)SDR ASAA2024031848467Sign · missingEXIT SIGN BY L-2 DOOR MISING. GROUNDED - YES. INSTALLED L2 DOOR EXIT LIGHT PER AMM 33-51-01 OPS CHECK NORMAL SPMC PATRICO NOTIFIED.SDR DALA2024031703388Control Unit · malfunctionedAIRCRAFT 1003, DURING SERVICE CHECK STEP 7G, FOUND SEVERAL SEAT EMERGENCY LIGHTS IN MIDDLE OF A/C THAT WOULD NOT AUTOMATICALLY SHUT OFF AFTER DOING CIDS EPSU SYSTEM TEST. CORRECTIVE ACTION: REPLACED EPCU 15WL. (LP 4413295)SDR AALA202403150725Light · brokenEMERGENCY LIGHT FIXTURE BROKEN AND STICKING OUT. LAV. 3F-1RC. LOWER FORWARD CORNER. MAINTENANCE REMOVED AND REPLACED EMERGENCY LIGHT FIXTURE AT LAV 3F-1RC LOWER FORWARD CORNER IAW AMM 33-51-06.SDR SWAA2024031463332Sign · detachedRT OVERAWING EMERGENCY DOOR EXIT SIGN OFF<[01] INSTALLED RT. OVERAWING DOOR EXIT SIGN IAW AMM 33-51-04SDR DALA2024031403358Battery Pack · inoperative(LOG 5429872) EMERGENCY LIGHTS AT ROWS 24-27 DEF INOP. REMOVED AND REPLACED M1671 BATTERY PACK PER B737 WDM 33-51-11. OPS CHECKS GOOD.SDR REXA2024031400282Lamp · inoperativeRH AFT EXTERIOR OVERWING EMERGENCY LIGHT BULB, BURNT OUT REMOVED AND REPLACED RH AFT EXTERIOR OVERWING EMERGENCY LIGHT BULB IAW GOODRICH CMM 33-52-07. P/N ON/OFF: 8GH002473-08 OPS TEST GOOD.SDR CALA2024031400728Battery Pack · dischargedM/D L1 DOOR CEILING PANEL M33093 EMER POWER PACK FOUND LOW CAPAC ITY,ORIGINATED BY , REF TO HAECO NON ROUTINE NO.948110 1 SPEC NO.B777-33-3-7019. PERFORMED BY, REPLACED M/D L1 DOOR CEILING PANEL M330 93 EMER POWER PACK AND C/O TEST OF THE NEW POWER PACK,THE SDR CALA2024031400727Lens · crackedEMERGENCY FLOOR PROXIMITY LIGHT LENS CRACKED/MISSING AT "LAV D". REPLACED LENS REF AMM 33-51-14SDR CALA2024031400726Battery Pack · dischargedM/D L4 DOOR 1EA EMER LT POWER PACK (M33407) FOUND LOW CAPACITY,O RIGINATED BY, REF TO HAECO NON ROUTINE NO.9479556 SPE C NO.B777-25-3-7250. PERFORMED BY , REPLACED M/D L4 DOOR M33407 EMER LT POW ER PACK AND C/O NEW POWER PACK TEST. THE RESULT FOUND NORMAL ASSDR CALA2024031400725Battery Pack · dischargedM/D R2 DOOR 1EA EMER LT POWER PACK (M33098) FOUND LOW CAPACITY,O RIGINATED BY , REF TO HAECO NON ROUTINE NO.9479563, SPE C NO.B777-25-3-7250. PERFORMED BY , REPLACED M/D R2 DOOR M33098 EMER LT POW ER PACK AND C/O NEW POWER PACK TEST,THE RESULT FOUND NORMAL ASDR CALA2024031400724Battery Pack · dischargedM/D R1 DOOR CEILING PANEL M33094 EMER LT POWER PACK FOUND LOW CA PACITY,ORIGINATED BY, REF TO HAECO NON ROUTINE NO.948 1100 SPEC NO.B777-25-3-7250. PERFORMED BY , REPLACED THE M/D R1 DOOR CEILING PANEL M33094 EMER LT POWER PACK AND C/O THE NEW POWER PACK TESSDR JJBA20240314048Sign · inoperativeSERVICE DOOR CEILING EMERGENCY EXIT SIGN INOPERATIVE. REMOVED AND REPLACED EMERGENCY EXIT SIGN. OPS CHECK SAT.SDR SWAA2024031362566Battery Pack · no testEMX LIGHT BATT PACK M01674 FAILS CAPACITANCE CHECK<[01] 01 - REMOVED AND REPLACED EMX BATTERY PACK M01674 PER [AMM 33-51-06-960-805-NG (POWER SUPPLY - BATTERY PACK REPLACEMENT - PERMANENT)]SDR SWAA2024031362565Battery Pack · no testEMX LIGHT BATT PACK M01668 FAILS CAPACITANCE CHECK<[01] 01 - REMOVED AND REPLACED EMX BATTERY PACK M01668 PER [AMM 33-51-06-960-805-NG (POWER SUPPLY - BATTERY PACK REPLACEMENT - PERMANENT)]SDR SWAA2024031362653Light · brokenFORWARD PAX ENTRY DOOR LOWER FORWARD EXIT LIGHT BROKEN.<[01] REMOVED AND REPLACED FORWARD PAX ENTRY DOOR LOWER FORWARD EXIT LIGHT ASSEMBLY. REF AMM 33-51-01. OPERATIONAL CHECK GOOD.SDR AALA202403136063Power Supply · failedAIRCRAFT WAS NOT GROUNDED: EMERGENCY POWER SUPPLY UNIT TEST FAILING. REPLACED EMERGENCY POWER SUPPLY UNIT AT 17WL.SDR CALA2024031300715Battery Pack · dischargedM/D L2 DOOR 1EA EMER LT POWER PACK (M33099) FOUND LOW CAPACITY,O RIGINATED BY , REF TO HAECO NON ROUTINE NO.9479561 SPE C NO.B777-25-3-7250. REPLACED M/D L2 DOOR M33099 EMER LT POW ER PACK AND C/O NEW POWER PACK TEST,THE RESULT FOUND NORMAL AS P ER AMM 33-51SDR CALA2024031300714Battery Pack · dischargedM/D L3 DOOR 1EA EMER LT POWER PACK (M33405) FOUND LOW CAPACITY,O RIGINATED BY ,REF TO HAECO NON ROUTINE NO.9479572 SPE C NO.B777-33-3-7019. REPLACED M/D L3 DOOR M33405 EMER LT POW ER PACK AND C/O NEW POWER PACK TEST,THE RESULT NORMAL AS PER AMM 33-51-06-960-8SDR SWAA2024042478769Lens · looseEXIT SIGN ABOVE AISLE AT MID CABIN BY EMERGENCY EXIT ROW FELL DOWN IN FLIGHT<[01] REINSTALLED EXIT SIGN LENS REF SIP.SDR SWAA2024040962405Light · deterioratedDETERIORATED STRIP PHOTOLUMINESCENT FLOOR PROXIMITY LIGHTING ON SEVERAL POSITIONS AT PASSENGER CABIN. REPLACED STRIP PHOTOLUMINESCENT FLOOR PROXIMITY LIGHTING ON SEVERAL POSITIONS AT PASSENGER CABIN (10 EA) IAW B737-700 AMM 33-51-15-400-802.SDR SWAA2024031561942Power Supply · inoperativeEMERGENCY LIGHTS LOCATED AT SEAT 17; 21 FED; AND THE RH AFT OVERWING ESCAPE HATCH ARE INOP.<[01] REMOVED AND REPLACED THE EMERGENCY LIGHT POWER SUPPLY AND BATTERY PACK LOCATED AT RH BS 727D; OPS CHECK GOOD PER AMM 33-51-06.;[02] INSPECTION C/W FOR C/A #1. TROYSDR SWAA2024031563529Battery Pack · inoperativeEMERGENCY LIGHTS LOCATED AT SEAT 17; 21 FED; AND THE RH AFT OVERWING ESCAPE HATCH ARE INOP.<[01] REMOVED AND REPLACED THE EMERGENCY LIGHT POWER SUPPLY AND BATTERY PACK LOCATED AT RH BS 727D; OPS CHECK GOOD PER AMM 33-51-06.;[02] INSPECTION C/W FOR C/A #1. TROYSDR AALA202403154082Lens · unserviceableAIRCRAFT IN BASE MAINTENANCE: FORWARD CLOSET EMERGENCY LIGHT LENS IS UNSERVICEABLE. REMOVED AND REPLACED NEW FORWARD CLOSET EMERGENCY LIGHT LENS AND TEST GOOD. PER B737NG AMM 33-51-14.SDR AALA202403157245Light · inoperativeEMERGENCY EXIT LIGHT LH FWD DAMAGED BY G3 GALLEY / CLOSET. MAINTENANCE REMOVED AND REPLACED LIGHT ASSEMBLY EMERGENCY EXIT LIGHT LH FWD G3 GALLEY/CLOSET AND PERFORMED OPERATIONAL TEST. IAW B777-2 SWPM20-10-13. AMM 33-51-05-960-802.SDR DALA2024031303285Light · inoperativeAIRCRAFT 3005, ON SVC CHECK FOUND AFT ROWS PATHWAY LIGHTS OUT. CORRECTIVE ACTION: FOUND LOW RESISTANCE ON 4L PACK SLIDE LIGHTS. SLIDE PACK REPLACED ALL EPSU OPS CKS GOOD AT THIS TIME. ALL EMER LIGHTS CK GOOD PER AMM 33-51. A/C OK FOR SVC. (LP 5409518)SDR DALA2024031203234Power Supply · failedAIRCRAFT 3005, RIGHT MID EPSU FAILED. CORRECTIVE ACTION: REPLACED RIGHT MID EPSU. (LP 5409521)SDR DALA2024031203233Power Supply · failedAIRCRAFT 3005, FORWARD EPSU FAILED. CORRECTIVE ACTION: REPLACED FORWARD EPSU (10WL). (LP 5409520)SDR DALA2024031403356Power Supply · inoperative(LOG 5016204) DURING SVC CK HAD SEATS 10DEF TO 17DEF AND OVERHEAD EMERGENCY LIGHTS INOP. REPLACED POWER SUPPLY AND BATTERY AT SEAT 10F LOWER SIDEWALL PER B 737 AMM 33-51. OPS CHK PER B 737 AMM 33-51.SDR SWAA2024031362009Battery Pack · no testM1669 FAILED CAPACITY CHECK<[01] R/R M1669 BATTERY PACK PER AMM 33-51-06SDR SWAA2024031362007Battery Pack · no testM1672 FAILED CAPACITY CHECK<[01] R/R M1672 BATTERY PACK PER AMM 33-51-06SDR SWAA2024031362130Lamp · inoperativeR/S EXTERIOR EMERGENCY LIGHT OUT.<[01] REPLACED OVER WING LAMP IAW AMM 33-51-04. ALL EMERGENCY LIGHTS WORKING.SDR SWAA2024031362858Power Supply · inoperativeFWD EMERGENCY LIGHTS INOP.<[01] 01 - REMOVED AND REPLACED PER [AMM 33-51-06-960-805-NG (POWER SUPPLY - BATTERY PACK REPLACEMENT - PERMANENT)]SDR SWAA2024031362194Battery Pack · inoperativeFWD EMERGENCY LIGHTS INOP.<[01] 01 - REMOVED AND REPLACED PER [AMM 33-51-06-960-805-NG (POWER SUPPLY - BATTERY PACK REPLACEMENT - PERMANENT)]SDR N6WA2024031301Bulb · inoperativeEMER LIGHT AT ROW 7 INOP. R&R BULB AT EMER LIGHT AT ROW 7. IAW CRJ 550 AMM 33-51-09.SDR SWAA2024031362110Spring · inoperativeAFT F/A EMEGENCY EXIT LIGHT BUTTON COVER SPRING INOP.<[01] 01 - REMOVED AND REPLACED PER [AMM 25-25-11-400-803-NG (ATTENDANT PANEL FLIPGUARD ASSEMBLY INSTALLATION - PERMANENT)]<BR>AFT F/A EMEGENCY EXIT LIGHT BUTTON COVERSDR DALA2024031303318Power Supply · inoperativeSHIP 5654 DURING SERVICE CHECK FOUND R2 DOOR UPPER EMERGENCY LIGHT INOP. CORRECTIVE ACTION: R/R R2 EMERGENCY PSU PER B757 AMM 33-51. OPS CHECK GOOD. (5239680)SDR AALA202403134438Light · intermittentAIRCRAFT WAS NOT GROUNDED: LEFT AFT OVERWING EMERGENCY LIGHT FLICKERING. REMOVE AND REPLACED LEFT AFT OVERWING EXIT LIGHT. PER AMM 33-21-00. FUNCTIONAL CHECK GOOD.SDR AALA202403135172Housing · brokenAIRCRAFT WAS NOT GROUNDED: EMERGENCY LIGHT BASE BROKEN. REMOVED AND REPLACED LIGHT ASSY AT ROW 17 DEF. PER AMM 33-51-01. OPERATIONAL TESTED GOOD.SDR AALA202403134251Lens · missingAIRCRAFT WAS NOT GROUNDED: AFT GALLEY EMERGENCY EXIT LIGHT COVER MISSING. REMOVED AND REPLACED AFT GALLEY EMERGENCY EXIT LIGHT ASSEMBLY. PER AMM 33-51-01. FUNCTIONAL CHECK GOOD CHECK GOOD.SDR AALA202403130887Light · damagedAIRCRAFT WAS NOT GROUNDED: EMERGENCY PATH LIGHT DAMAGED. MAINTENANCE REPLACED EMERGENCY FLOOR PROXIMITY LIGHT ON SEAT 3G, 6D, AND 6G. ALL OPS CHECKS GOOD REF AMM 33-51-00 AND CMM 25-02-67.SDR DALA2024031303291Cover · looseSHIP 183 EMERGENCY EXIT SIGN COVER LOOSE / LOCATIONS:603. CORRECTIVE ACTION: RESECURED EXIT SIGN COVER (0241818)SDR DALA2024031303289Light · damagedSHIP 195 EMERGENCY SEAT MOUNTED LIGHTING DAMAGED / INOP / LOCATIONS:603. CORRECTIVE ACTION: OPS CHK'S NML. OK FOR SVC. (0241055)SDR CALA2024031300713Battery Pack · no testB777-33-3-7019, DR R3 M33401 EMER LIGHT BATTERY TEST FAIL. TRANSFER REF.NON-ROUTINE HX NRC WO.2960138 AND ORIGINATED BY . DR R3 M33401 EMER LIGHT BATTERY REPLACED AND TESTED NORMAL AS PER AMM 33-51-06 AND ATTACH FORM 44-0008 ITEM 1 TO 2 ACCOMPLISHED.SDR CALA2024031300712Charger · no testB777-33-3-7019, DR R3 M33401 EMER LIGHT BATTERY CHARGER TEST FAIL. TRANSFER REF.NON-ROUTINE HX NRC WO.2960129 AND ORIGINATED . DR R3 M33401 EMER LIGHT BATTERY CHARGER REPLACED AND TESTED NORMAL AS PER AMM 33-51-06.SDR DXTA2024031311178Battery · inoperativeCABIN EMER LIGHTS STAY ILLUMINTED WHEN THE SWITCH IS IN THE ARM POSITION. REMOVED DEFECTIVE FWD EMR BATTERY PACK AND REPLACED WITH A NEW CUSTOMER SUPPLIED BATTERY. REMOVED INOP AFT EMR BATTERY PACKS AND REPLACED WITH A TESTED, CUSTOMER SUPPLIED BATTERY PACK I
Back to JASC 3350