JASC 3350
Service difficulty reports · 225,886
Reports filed under 3350 · Emergency Lighting, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3350' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3350' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DXTA2022102672790Battery Pack · inoperativeEMERGENCY LIGHTING: CABIN, EXTERIOR, AND LAV EMERGENCY LIGHTS FAIL TO ILLUMINATE DURING PREFLIGHT CHECKS. PERFORMED EMERGENCY LIGHTING POWER SUPPLY BATTERY EXERCISE PROCEDURE REV. 2 DATED 200CT2022. OPS CHECK GOOD IAW CE-680 AMM 33-50-10.SDR ASAA2022102441427Battery Pack · no testEMERGENCY LIGHTS FAILED 15 MINUTE CHECK AT : R1 DOOR HEADER. LH ROW 3 BULL NOSE, LIGHT BY FWD LAV CENTER, FLT DECK DOME LIGHT AND L1 OUTSIDE LIGHT - ON ONE BATTERY. GROUNDED - YES. REMOVED, REPLACED, AND OP CK GOOD BOTH EMERGENCY BATTERY PACKS (SN 192800) ABOVSDR ASAA2022102441426Battery Pack · no testEMERGENCY LIGHTS FAILED 15 MINUTE CHECK AT : R1 DOOR HEADER. LH ROW 3 BULL NOSE, LIGHT BY FWD LAV CENTER, FLT DECK DOME LIGHT AND L1 OUTSIDE LIGHT - ON ONE BATTERY. GROUNDED - YES. REMOVED, REPLACED, AND OP CK GOOD BOTH EMERGENCY BATTERY PACKS (SN 174496) ABOVSDR ASAA2022102441425Battery Pack · no testEMERGENCY LIGHTS FAILED 15 MINUTE CHECK AT: L2 HEADER PANEL, RH ROW 20 BULL NOSE AND AFT RECESSED PANEL LIGHT. GROUNDED - YES. REMOVED, REPLACED AND OP CK GOOD EMERGENCY BATTERY PACK (SN 187643) ABOVE AFT GALLEY RH SIDE IAW B737-0700 AMM 33-51-06-960-805.SDR REXA2022110102345None · inoperative14962SDR SWAA2022102763969Light · inoperativeCUSTOMER WALK: EMERGENCY LIGHT ABOVE L-1 DOOR HAS 1 BULB INOPERATIVE. / [01] RE-LAMPED EMERGENCY LIGHT ABOVE L-1 DOOR AS PER AMM 33-51-01-960-801; TEST OK;[02] VERIFIED STEP 1SDR SWAA2022102763861Battery Pack · inoperativeMAIN CABIN SEVERAL EMERGENCY LIGHTS AND SERVERAL EXIT SIGN INOPS. / [01] REMOVED AND REPLACED BATTERY PACKS OPS CHECK GOOD; PER AMM 33-51-06.SDR IPXA2022102487481Battery Pack · inoperativeFLT DECK INTERIOR EMERGENCY LIGHTS OVER ENTRY DOOR INOP. R & R EMERGENCY EXIT LIGHT BATTERY ENTRY DOOR. OPS CK GOOD IAW AMM 33-51-01-012-002, 33-51-01-402-003. OPS CK GOOD. THIS CLEARS M793866SDR DALA2022102606955Battery · mislocatedDURING THE SERVICE CHECK, THE EMERGENCY LIGHTS AND CELING EXIT SIGN BETWEEN ROWS 105-19 WERE FOUND TO BE INOPERATIVE. TROUBLE SHOOTING SYSTEM PER B717 FIM 35-50-00 810-801, NARROWED DOWN TO BATTERY PACK B5-120 LOCATED UNDER PNL 222LR AT STA 645R PANEL; NOT LOCSDR AALA202210256304Lamp · inoperativeAIRCRAFT IN BASE MAINTENANCE: LEFT FUSELAGE R1 DOOR EXTERIOR ENTER EXIT LIGHT DIM. REMOVED AND REPLACED LEFT FUSELAGE R1 DOOR EXTERIOR EMERGENCY EXIT LAMP PER AMM 33-51-04.SDR AALA202210257024Lamp · inoperativeAIRCRAFT IN BASE MAINTENANCE: LEFT FUSELAGE FORWARD OVERWING ENTER EXIT LIGHT DIM. REMOVED AND REPLACED FORWARD OVERWING EMERGENCY EXIT LAMP PER AMM 33-51-04.SDR DALA2022102506945Sign · detachedSHIP 5656 PLASTIC "EXIT" SIGN DETACHED FROM EXIT ROW. CORRECTIVE ACTION: SECURED "EXIT" SIGN COVER. (8655680)SDR AALA202210252101Power Supply · noneAIRCRAFT WAS GROUNDED: EMERGENCY POWER SUPPLY UNIT 10WL FAILED TEST. MAINTENANCE REPLACED EMERGENCY POWER SUPPLY UNIT 10WL (AALA202210252101) AND BATTERY (AALA202210259052) PER AMM 33-51-38. A SATISFACTORY OPERATIONAL CHECK WAS ACCOMPLISHED.SDR AALA202210259052Battery · noneAIRCRAFT WAS GROUNDED: EMERGENCY POWER SUPPLY UNIT 10WL FAILED TEST. MAINTENANCE REPLACED EMERGENCY POWER SUPPLY UNIT 10WL (AALA202210252101) AND BATTERY (AALA202210259052) PER AMM 33-51-38. A SATISFACTORY OPERATIONAL CHECK WAS ACCOMPLISHED.SDR AALA202210259707Shroud · brokenAIRCRAFT WAS NOT GROUNDED: EMERGENCY LIGHT AT SEAT 13C BROKEN OFF. MAINTENANCE REPLACED EMERGENCY LIGHT SHROUD ASSEMBLY PER AMM 33-50-00 AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.SDR SWAA2022102563671Light · inoperativeEXTERIOR EMERGENCY LIGHT BEHIND FWD ENTRY DOOR INOP / [01] REMOVED AND REPLACED EXTERIOR EMER LIGHT BEHIND FWD ENTRY DOOR PER AMM 33-51-04. OPS CHECKS GOOD AT THIS TIMESDR SWAA2022102563700Light · looseCREW REPORTED OVER WING EMERGENCY EXIT LIGHT NOT SECURED / [01] RESECURED OVERWING EXIT EMERGENCY LIGHT PER SIPSDR DXTA2022102572730Battery Pack · inoperativeTHE EMERGENCY EXTERIOR LIGHT AND INTERIOR LIGHTS ASSOCIATED WITH THIS BATTERY PACK ARE NOT ILLUMINATING WITH THE EMERGENCY LIGHT SWITCH SELECTED ON. THE EMERGENCY EXTERIOR LIGHTS ARE CONSIDERED INOPERATIVE. PERFORMED FUNCTIONAL CHECK. UNABLE TO DUPLUCATE SQK.SDR MASA2022102400248Sign · inoperativeROW 3DF EXIT SIGN INOPSDR DALA2022102406844Light · inoperative(LOG 9443576) DURING INSPECTION FOUND 17F VERTICLE EXIT LIGHT INOP. REPLACED LIGHT ASSY PN BR9476-G-145-01 REF B737 IPC 33-51-01-06C ITEM 545, REF B737 AMM 33-51-01-201.SDR REXA2022110102324Bulb · inoperativeLEFT AFT OUTSIDE EMERGENCY LIGHT INOP EMERGENCY LIGHT INOP. CORRECTIVE ACTION: REMOVED 4 SCREWS AND COVER. REMOVED AND REPLACED L/H AFT OUTSIDE EMERGENCY BULB WITH P/N 8GH0024-73-08. INSTALLED COVER AND 4 SCREWS IAW CRJ900 AMM 20-21-00-910-801- A01. OP TEST GOSDR SWAA2022102763348Battery Pack · inoperativeSEVERAL PASSENGER CABIN EMERGENCY LIGHTS AND EXTERIOR EMERGENCY LIGHTS INOP. / [01] REPLACED EMERGENCY BATTERY PACK M1673 PERFORMED AFT EMERGENCY EXIT OPS TEST; TEST PASSED PER B737-800 AMM 33-51-06-960-805.;[02] REPLACED EMERGENCY BATTERY PACKS M1670; M2816; SDR AALA202210256369Battery · noneAIRCRAFT WAS NOT GROUNDED: EMERGENCY POWER SUPPLY UNIT 10WL FAULT MESSAGE. MAINTENANCE REPLACED EMERGENCY POWER SUPPLY UNIT 10WL BATTERY AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 33-51-38.SDR AALA202210250710Power Supply · noneAIRCRAFT WAS NOT GROUNDED: EMERGENCY POWER SUPPLY UNIT 12WL FAULT MESSAGE. MAINTENANCE REPLACED EMERGENCY POWER SUPPLY UNIT 12WL (AALA202210250710) AND BATTERY(AALA202210251491) PER AMM 33-51-38. A SATISFACTORY OPERATIONAL CHECK WAS ACCOMPLISHED.SDR AALA202210251491Battery · noneAIRCRAFT WAS NOT GROUNDED: EMERGENCY POWER SUPPLY UNIT 12WL FAULT MESSAGE. MAINTENANCE REPLACED EMERGENCY POWER SUPPLY UNIT 12WL (AALA202210250710) AND BATTERY (AALA202210251491) PER AMM 33-51-38. A SATISFACTORY OPERATIONAL CHECK WAS ACCOMPLISHED.SDR SWAA2022102563387Light · inoperativeL2 DOOR EMERGENCY SLIDE LIGHT INOP / [01] REMOVED AND REPLACED L2 DOOR EMERGENCY SIDE LIGHT PER AMM 33-51-04. OPS CHECK IS GOOD AT THIS TIME.SDR SWAA2022102563399Sign · looseRH AFT GALLEY DOOR LOWER EMERGENCY EXIT SIGN IS LOOSE AND CRACKED / [01] REMOVED AND REPLACED RH AFT GALLEY DOOR LOWER EMERGENCY EXIT SIGN ASSY AND LENS IAW AMM 33-51-01. OPS CHECK GOOD.SDR SWAA2022102563398Sign · crackedLH AFT GALLEY; LOWER EMERGENCY EXIT DOOR SIGN IS CRACKED LH AFT GALLEY LOWER EMERGENCY EXIT DOOR SIGN IS CRACKED / [01] REMOVED AND REPLACED LH AFT GALLEY;LOWER EMERGENCY EXIT DOOR SIGN IAW AMM 33-51-01.SDR SWAA2022102564087Lens · crackedRH AFT GALLEY DOOR LOWER EMERGENCY EXIT SIGN IS LOOSE AND CRACKED / [01] REMOVED AND REPLACED RH AFT GALLEY DOOR LOWER EMERGENCY EXIT SIGN ASSY AND LENS IAW AMM 33-51-01. OPS CHECK GOOD.SDR SWAA2022102563382Lamp · inoperativeEMERGENCY LIGHT JUST AFT OF RH MLG INOP. / [01] RELAMPED EMERGENCY LIGHT AFT OF RH MLG; SATISFACTORY OP CK REF AMM 33-51-04.SDR SWAA2022102563708Lens · missingMID CABIN EXIT SIGN MISSING FORWARD COVER / [01] INSTALLED LENS PER M/M 33-51-01SDR WX0A2022102474291Epsu · inoperativeREF. WO # 465505 CABIN EMERGENCY LIGHTING TEST / REMOVED AND REPLACED EPSU 12WL, IAW AMM 33-51-38-400-002-A,REMOVED AND REPLACED EPSU (11WL) IAW AMM 33-51-38-400-001-A.REMOVED AND REPLACED EMERGENCY OVERWING LIGHT BULBS (61WL) AND (63WL) IAW AMM 33-51-15-000-SDR DXTA2022102472660Battery Pack · inoperativeEMERGENCY LIGHTS BATTERY: EMERGENCY LIGHTS DO NOT ILLUMINATE WHEN SELECTED TO ON. ACCOMPLISHED A POWER CYCLE TO INCLUDE DISCONNETING THE MAIN BATTERIES, WHICH HAD NO EFFECT. // SIGNOFF// T/S TO FAILED BATTERY PACK. REMOVED FAILED ASSY AND INSTALLED A REPAIREDSDR SIMA20221023001Battery Pack · inoperativeEMERGENCY ISLE LIGHT #2 INOP-C/A-REMOVED AND REPLACED LIGHT ASSEMBLY IAW AMM 33-50-13 . OPERATIONAL CHECK BAD, SEE ITEM 2 OF THIS NRWCSDR DXTA2022102472670Battery Pack · disconnectedEMERGENCY LIGHTS REMAIN ILLUMINATED WITH EMERGENCY LIGHT SWITCH IN THE ARM POSITION. ACCESS FWD AND AFT EMERGENCY BATTERIES FOR TROUBLESHOOTING. NOTED WITH THE FWD BATTERY CONNECTED AND THE AFT BATTERY DICONNECTED AND THE SWITCH IN THE ARM POSITION THE LIGHTSSDR DALA2022102606954Battery · inoperativeDURING THE SERVICE CHECK, MAINTENANCE FOUND THE EXTERIOR EMERGENCY LIGHTS TO NOT BE TESTING PROPERLY. THE OVERWING EMERGENCY EVACUATION BATTERY WAS REPLACED PER B717 AMM 33-51. (LP #9586900)SDR DALA2022102506942Battery Pack · inoperativeSHIP 5808 EMERGENCY LIGHTS POWER SUPPLY M11081 FAILED 15 MINUTE CAPACITY TEST PER AMDS WORKCARD. CORRECTIVE ACTION: R+R M11081 BATTERY PACK IAW B757 AMM 33-51. OPS CK GOOD. (2463536)SDR DALA2022102506941Battery Pack · inoperativeSHIP 5808 EMERGENCY LIGHTS POWER SUPPLY M737 FAILED 15 MINUTE CAPACITY TEST PER AMDS WORKCARD. CORRECTIVE ACTION: R+R M737 BATTERY PACK IAW B757 AMM 33-51. OPS CK GOOD. (2463531)SDR DALA2022102506940Battery Pack · inoperativeSHIP 5808 EMERGENCY LIGHTS POWER SUPPLY M11488 FAILED 15 MINUTE CAPACITY TEST PER AMDS WORKCARD. CORRECTIVE ACTION: R+R M11488 BATTERY PACK IAW B757 AMM 33-51. OPS CK GOOD. (2463525)SDR SWAA2022102563224Battery Pack · inoperativeEMERGENCY LIGHTS INOP ON EXTERIOR OF AFT SERVICE DOOR AND INTERIOR SIDE OF AFT SERVICE DOOR / [01] PERFORMED CHARGING OF THE BATTERY PACKS PER AMM 33-51-06. PERFORMED EMERGENCY LIGHTS OPERATIONAL CHECK PER AMM 33-51-00; ALL LIGHTS OPS CHECK GOOD.SDR DALA2022102406843Battery Pack · inoperative(LOG 9026930) DURING INSPECTION FOUND OVERHEAD EMERGENCY EXIT AISLE LIGHT AT ROW 30 INOP. R&R BOTH BATTERY PACK & BASE. EMERGENCY LIGHT NOW OP CHECKS NML. WORKED IAW B737 AMM 33-51.SDR DXTA2022102472610Battery Pack · inoperativeAFTER SHUTDOWN WE NOTICED THE TWO LEFT SIDE OVERHEAD EMERGENCY LIGHTS AND THE EXTERIOR BOARDING DOOR EMERGENCY LIGHT WERE ON WITH THE EMERGENCY LIGHT SWITCH IN THE OFF POSITION. THE AIRCRAFT WAS SHUT DOWN AND THE MAIN SHIP BATTERIES WERE OFF AND DISCONNECTED.SDR SWAA2022111662944Lens · brokenBROKEN GALLEY 1 EMERGENCY EXIT LENS ASSY AT FWD GALLEY AREA. REPLACED THE GALLEY EMERGENCY EXIT LENS IAW AMM 33-51-01-960-802. OPS TESTED OKSDR SWAA2022111662935Light · brokenBROKEN PHOTOLUMINESCENT FLOOR PROXIMITY LIGHTING AT PASSENGER CABIN (4 EA) 2022-596937 / [01] REPLACED PHOTOLUMINESCENT FLOOR PROXIMITY LIGHTING AT PASSENGER CABIN I.A.W B737-700 AMM 33-51-15-400-802;[02] REPLACED PHOTOLUMINESCENT FLOOR PROXIMITY LIGHTING AT PSDR DALA2022102106803None · noneSHIP 3310 ROW 30,31AB EEPLS LIGHTS INOP. CORRECTIVE ACTION: WIRE BROKEN AT SEAT 31A NEAR SIDEWALL. REPLACED SOCKET AND REINSERTED INTO CONNECTOR. (9444216)SDR DALA2022102706963Cover · missingSHIP 195 FOUND CEILING EMERGENCY LIGHT COVER MISSING 05EA. INSTALLED 5EA CEILING PANEL EMERGENCY LIGHT COVERS AND OPS CHECK REF B767-300 AMM 33-51 AND B767-300 AMM 25-22.SDR DALA2022102506933None · noneSHIP 1201 17R EMERGENCY LIGHT INOP.SEAT MOUNTED. CORRECTIVE ACTION: REPLACED CONNECTOR AT SIDEWALL OPS OK. (9478429)SDR DALA2022102506932None · noneSHIP 1707 SEATS 4A, 5A, 6A EMERGENCY PATH LIGHTS INOP. CORRECTIVE ACTION: FOUND 6A DICONNECTED, RECONNECTED 6A PER B767 WDM 33-51-31, ALL EMERGENCY LIGHTS CHECK GOOD (9043233)SDR FDEA202210212637Lamp · burned outL1 DOOR INTERIOR EXIT LIGHTS 3/4 OF LIGHTS BURNED OUT. REMOVED AND REPLACED L1 DOOR INTERIOR EXIT LIGHT SIGN IAW AMM 33-51-01-2. LIGHT OPS CHECKS NORMAL. ACFT OK FOR SERVICE.SDR WX0A2022102474289Battery · inoperativeDURING WEEKLY CHECK EPSU TEST BATTERY (11WL) FOR L/H O/W EPSU FAILED TEST / REMOVED L/H O/W EPSU BATTERY (11WL) REF AMM 33-51-38-000-002-A. INSTALLED SERVICEABLE EPSU BATTERY (11WL) AT L/H O/W EXIT REF AMM 33-51-38-400-002-A. OPS TEST GOOD."
Back to JASC 3350