JASC 3350
Service difficulty reports · 225,886
Reports filed under 3350 · Emergency Lighting, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3350' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3350' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SIMA20221009002None · unserviceableAFT EMERGENCY FLASHLIGHT HOLDER IS BROKEN AND LIGHT IS NOT CHARGING CORRECTLY-C/A-REPLACED AFT CABIN EMERGENCY FLASHLIGHT ASSEMBLY IAW EMB 145 MM 33-50-16. OPS CHECK GOOD.SDR DALA2022101206578None · noneSHIP 6817 ON ARRIVAL, POWER DROPPED OFF PLANE WITH PAX ONBOARD. SELECTED EMER LTS TO ON WITH NO RESPONSE. ROW 19-26 A/C RT ARE ON AND WILL NOT TURN OFF. ALL OTHER EMERG LTS INOP. CORRECTIVE ACTION: T/S PER WDM 33-51 AND FOUND K10570 RELAY FAULTY. R+R'D THE SAMSDR DALA2022101206564None · noneSHIP 1701 EMERGENCY EXIT COVER DIFFUSER LENS DAMAGED OR MISSING / LOCATIONS:602 CORRECTIVE ACTION: INSTALLED NEW LENSE, OPS CK NORMAL. (2445006)SDR DALA2022101206562None · noneSHIP 1201 EMERGENCY EXIT SIGNS INOPERATIVE / LOCATIONS:602, CORRECTIVE ACTION: REPLACED LENS REF B767 33-25 OPS OK (2443958)SDR DALA2022101206561None · noneSHIP 1201 FLT DECK EXIT SIGN INOP W/ EMRRG SWITCH ON, CORRECTIVE ACTION: REPLACED LIGHT ASSY OPS OK. REF B767 AMM 33-51 (9676656)SDR SWAA2022101157870Battery Pack · faultyEMERGENCY LIGHTS ON BATTERY PACK M1670 GO ON BRIEFLY THEN EXTINGUISH / [01] REMOVED AND REPLACED POWER SUPPLY M1670 BATTERY PACK REF AMM 33-51-06.SDR SWAA2022101157873Power Supply · inoperativeEMER LTS ON 6ABC; 9ABC; 12ABC; 8FED; MID CABIN EMERGENCY EXIT SIGN AND LH OVER WING EMER LT INOP / [01] REPLACED POWER SUPPLIES M1668 AND M2335 PER AMM 33-51-05. OPS CHK GOOD.SDR SWAA2022101158532Power Supply · inoperativeEMER LTS ON 6ABC; 9ABC; 12ABC; 8FED; MID CABIN EMERGENCY EXIT SIGN AND LH OVER WING EMER LT INOP / [01] REPLACED POWER SUPPLIES M1668 AND M2335 PER AMM 33-51-05. OPS CHK GOOD.SDR SWAA2022101157867Battery Pack · inoperativeEMERGENCY LIGHTS ON CABIN AND LH OVER WING EMERGENCY LIGHT INOP / [01] REMOVED AND REPLACED EMERGENCY LIGHT BATTERY PACK IAW AMM 33-51-06. OP CHECK GOOD.SDR SWAA2022101157893Battery · inoperativeEXTERIOR EMERGENCY LIGHTS ON THE AFT ENTRY DOOR AND EMERGENCY SIGNS ON THE LH SIDE OF AFT GALLEY INOP / [01] CHARGED THE EMERGENCY LIGHTS BATTERIES AND PERFORMED OPS CHK OF THE EMERGENCY LIGHTS PER AMM 33-51-00; OPS CHK GOOD.SDR SWAA2022101157774Fuse · inoperativeINOP EMERGENCY LIGHT 6 EA ADJACENT TO RT SIDE EMERGENCY DOOR AT PASSENGER CABIN 2022-533483 / [01] REMOVED AND REPLACED FUSE (3 EA) ON EMERGENCY EXIT LIGHT BATTERY PACK M1668 AND M1669 AND PERFORMED TEST IAW B737-700 AMM 33-51-06-960-804. TEST IS OK.;[02] TASKSDR SWAA2022101158063Fuse · inoperativeOVER WINGS INTERIOR AND EXTERIOR EMERGENCY LIGHTS INOP 2022-533510 / [01] REMOVED AND REPLACED FUSE (3 EA) ON EMERGENCY EXIT LIGHT BATTERY PACK M1668 AND M1669 AND PERFORMED TEST IAW B737-700 AMM 33-51-06-960-804. TEST IS OK.;[02] TASK CARD COMPLETE.SDR YENA2022101101017None · failedFLT#70FLL-BOS. 'UPON AIRCRAFT DROPPING GROUND POWER ONLY AFT CABIN CEILING LIGHT ILLUMINATED; REF. L/P PAGES 3526363, 3526364, 3526365 ITEMS #1 AND #2 FOR REMOVAL OF ALL SIX EPSU BATTERIES. OP'S CHECK IS OK AT THIS TIME. ALL IAW AMM 33-51-38-400-002-A.'REMOVESDR YENA2022101101016None · failedFLT#70FLL-BOS. 'UPON AIRCRAFT DROPPING GROUND POWER ONLY AFT CABIN CEILING LIGHT ILLUMINATED; REF. L/P PAGES 3526363, 3526364, 3526365 ITEMS #1 AND #2 FOR REMOVAL OF ALL SIX EPSU BATTERIES. OP'S CHECK IS OK AT THIS TIME. ALL IAW AMM 33-51-38-400-002-A.'REMOVESDR YENA2022101101015None · failedFLT#70FLL-BOS. 'UPON AIRCRAFT DROPPING GROUND POWER ONLY AFT CABIN CEILING LIGHT ILLUMINATED; REF. L/P PAGES 3526363, 3526364, 3526365 ITEMS #1 AND #2 FOR REMOVAL OF ALL SIX EPSU BATTERIES. OP'S CHECK IS OK AT THIS TIME. ALL IAW AMM 33-51-38-400-002-A.'REMOVESDR YENA2022101101014None · failedFLT#70FLL-BOS. 'UPON AIRCRAFT DROPPING GROUND POWER ONLY AFT CABIN CEILING LIGHT ILLUMINATED; REF. L/P PAGES 3526363, 3526364, 3526365 ITEMS #1 AND #2 FOR REMOVAL OF ALL SIX EPSU BATTERIES. OP'S CHECK IS OK AT THIS TIME. ALL IAW AMM 33-51-38-400-002-A.'REMOVESDR YENA2022101101013None · failedFLT#70FLL-BOS. 'UPON AIRCRAFT DROPPING GROUND POWER ONLY AFT CABIN CEILING LIGHT ILLUMINATED; REF. L/P PAGES 3526363, 3526364, 3526365 ITEMS #1 AND #2 FOR REMOVAL OF ALL SIX EPSU BATTERIES. OP'S CHECK IS OK AT THIS TIME. ALL IAW AMM 33-51-38-400-002-A.'REMOVESDR YENA2022101101012None · failedFLT#70FLL-BOS. 'UPON AIRCRAFT DROPPING GROUND POWER ONLY AFT CABIN CEILING LIGHT ILLUMINATED; REF. L/P PAGES 3526363, 3526364, 3526365 ITEMS #1 AND #2 FOR REMOVAL OF ALL SIX EPSU BATTERIES. OP'S CHECK IS OK AT THIS TIME. ALL IAW AMM 33-51-38-400-002-A.'REMOVESDR DALA2022101106556None · noneSHIP 699 EXIT SIGN FELL OFF IN FLIGHT FROM ABOVE DOOR 2L. CORRECTIVE ACTION: REATTACHED LENS AND REINSTALLED LENS ASSY IAW B757 AMM 33-51 OPS CK GOOD. (9062230)SDR AALA202210110710Power Supply · noneAIRCRAFT WAS NOT GROUNDED: EMERGENCY POWER SUPPLY UNIT 14WL FAULT MESSAGE. REPLACED EMERGENCY POWER SUPPLY UNIT 14WL PER AMM 33-51-38 AND ACCCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.SDR AALA202210110243Lamp · inoperativeAIRCRAFT IN BASE MAINTENANCE: ROW 16 ABC AFT EMERGENCY EXIT LIGHT BULB OUT. REMOVED AND REPLACED LAMP AT ROW 16 ABC AFT EMERGENCY EXIT LIGHT PER B737 NG AMM 33-51-01SDR AALA202210113250None · noneAIRCRAFT WAS NOT GROUNDED: ROW 16F EXIT SIGN LIGHT FLICKERS. **SUPPLEMENTAL REPORT WILL BE SUBMITTED.** (OPEN)SDR AALA202210108440Battery · noneAIRCRAFT WAS NOT GROUNDED: DURING EMERGENCY POWER SUPPLY UNIT SYSTEM TEST, EMERGENCY POWER SUPPLY UNIT 13WL BATTERY FAULT MESSAGE DISPLAYED. MAINTENANCE REPLACED BATTERY PER AMM 33-51-38 AND ACCOMPLISHED A SATISFACTORY OPERATIONAL / BITE TEST PER AMM 33-51-00.SDR DXTA2022101071840Switch · trippedEMERGENCY LIGHTS BATTERY: 5G SWITCH TRIPPED ON ONE OF THE EMERGENCY LIGHT BATTERIES. LIGHT OVER SEAT 8 AS WELL AS THE FORWARD OVER-WING LIGHT AND SHARK LIGHT REMAIN ON WITH EMER LIGHTS SWITCH OFF AND POWER REMOVED FROM THE AIRCRAFT. GAINED ACCESS TO AND RESET SDR CALA2022101002756Battery · inoperativeOPERATIONAL TEST FND L/H DOOR NO.2 TO 25ABC CEILING EMER LIGHT INOP, REFER TO HAECO NR NO.9494136, ORIGINATED BY EMP V903529, SPEC NO. B777-33-3-7019. PERFORMED BY EMP V905416 IDT BY TA393, REPLACED L/H NO.2 DOOR EMERGENCY LT BATTERY, PERFORMED OP TEST, THE RESDR CALA2022101002755Light · damagedSEAT MOUNTED EMERGENCY LIGHT AT 11ABC DAMAGED. REMOVED AND REPLACED LIGHT ASSY REF MM 33-51-11. OPS CK OK. VERIFIED IDT REQUIREMENTS FOR EMEGENCY PATH LIGHTING AT ROW 11ABC.SDR SWAA2022101257581None · faultyEMERGENCY BATTERY PACK DEFECTIVE AT POSITION M1674. REMOVE AND REPLACE EMERGENCY BATTERY PACK P/N: D717-01-100SWA AND PERFORM OPERATIONAL TEST. / [01] REPLACED EMERGENCY BATTERY PACK AT M1674 WITH SERVICEABLE BATTERY PACK. S/N: WN 1177 PERFORMED OPS TEST; TESTSDR DALA2022101206571Light · inoperative(LOG 7876150) DURING INSPECTION FOUND EMERGENCY LIGHT INOP. R AND R LIGHT REF B737 AMM 33-21. OPS CHECKS GOOD.SDR DALA2022101206570Battery Pack · inoperative(LOG 9058749) DURING INSPECTION FOUND R1 DOOR AND 1ST CLASS RIGHT EMERGENCY LIGHTS INOP. INSTALLED NEW BATTERY. OPS TESTS GOOD.SDR SWAA2022101157475Sign · inoperativeCUSTOMER REQUEST: ONE BULB INOP EMERGENCY LOWER AT L-1 DOOR / [01] RELAMPED EMERGENCY LOWER EXIT SIGN AT L-1 DOOR PER REF. AMM 33-51-01-960-801. PERFORMED OPS CHECK AND FOUND NORMAL.;[02] VERIFIED STEP 1SDR SWAA2022101157477Battery Pack · inoperativeCUSTOMER REQUEST: EXTERIOR EMERGENCY LIGHT AFT OF R-1 DOOR INOP / [01] REMOVED AND REPLACED BATTERY PACK M1674 ON TTG8Q00F9CTY. R-1 DOOR EXTERIOR EMERGENCY LIGHT TEST NORMAL PER AMM 33-51-00-710-801.;[02] VERIFIED STEP 1SDR SWAA2022101157476Battery Pack · inoperativeCUSTOMER REQUEST: RT STOW BIN ROW 3/ROW 6 EMERGENCY LIGHT INOP / [01] REMOVED AND REPLACED M1674 EMERGENCY BATTERY PACK PER AMM 35-51-06-960-805. TEST NORMAL.;[02] VERIFIED STEP 1SDR SWAA2022101157474Battery Pack · inoperativeCUSTOMER REQUEST: L-1 DOOR UPPER EMERGENCY EXIT SIGN INOPERATIVE / [01] REMOVED AND REPLACED M1674 EMERGENCY BATTERY PACK ON TTG8Q 00F9CTY. L-1 DOOR EMERGENCY EXIT SIGN TEST NORMAL PER AMM33-51-00-710-801.;[02] VERIFIED STEP 1SDR SWAA2022101157273Battery Pack · inoperativeEMERGENCY EXIT LIGHTS ATTACHED TO M1672 DO NOT ILLUMINATE. / [01] REMOVED AND REPLACED EMERGENCY LIGHT BATTERY PACK M1672 AND PERFORMED SATISFACTORY INSTALLATION TEST PER AMM 33-51-06-960-805.;[02] VERIFIED CORRECTIVE ACTION #1.SDR SWAA2022101157272Charger · inoperativeEMERGENCY EXIT LIGHTS ATTACHED TO M1675 DO NOT ILLUMINATE. / [01] REMOVED; REPLACED; AND TESTED M1675 EMERGENCY BATTERY CHARGER PER AMM 33-51-06-960-806 AND M1675 EMERGENCY BATTERY PER AMM 33-51-06-960-805; NO DEFECTS NOTED.;[02] VERIFIED CORRECTIVE ACTION #1.SDR SWAA2022101157271Battery Pack · inoperativeEMERGENCY EXIT LIGHTS ATTACHED TO M1673 DO NOT ILLUMINATE. / [01] REMOVED AND REPLACED EMERGENCY LIGHT BATTERY PACK M1673 AND PERFORMED SATISFACTORY INSTALLATION TEST PER AMM 33-51-06-960-805.;[02] VERIFIED CORRECTIVE ACTION #1.SDR YENA2022101101011None · noneDURING HEAVY MAINTENANCE: EMERGENCY LIGHTS AT AFT SERVICE AND ENTRY DOOR LININGS WERE FOUND INOP; REF TOMX WO 2082 NR 00148. EMERGENCY LIGHT POWER UNITS WERE REPLACED PER EMB-190 AMM 33-50-01. SATISFACTORY TEST. COMPLETED BY: 201637252 - VELASCO CARMONA, SDR DALA2022101006541None · noneSHIP 6712 4L DOOR EXIT LIGHT INOP. CORRECTIVE ACTION: REPLACED M00737 BATTERY CHARGER AND BATTERY PACK PER B757 AMM 33 -51 - OPERATION NOW NORMAL. (9092459)SDR DALA2022101006523None · noneSHIP 3414 EXIT SIGNS ALWAYS ON 2LAND 4L. CORRECTIVE ACTION: UNABLE TO DUPLICATE DISCREPANCY, OPS CHECK OF EMERGENCY LIGHTS NORMAL. SUSPECT POWER RESET CORRECTED FAULT. (2443693)SDR DXTA2022101071820Battery Pack · inoperativeMAIN EXIT SIGN/LIGHT: THE MAIN EXIT SIGN AND SEAT 10 EMERGENCY LIGHTS REMAIN ILLUMINATED WITH EMER LTS SWITCH IN THE OFF POSITION. GAINED ACCESS TO THE# I EMERGENCY BATTERY PACK. REMOVED AND INSTALLED REPAIRED UNIT. CHARGED THE BATTERY FOR 60 MINUTES. OPS CHESDR MASA202210070241Battery Pack · depletedROW 4 EMERG EXIT INOP
R&R #4 EMERGENCY BATTERY PACKSDR MASA202210070240Bulb · inoperativeEMERG CEILING LIGHT INOP AT ROW 14
REPLACED BULBSDR SWAA2022110156776Battery Pack · inoperativeINOP LOWERED CEILING PANEL CENTER LH BATTETY PACK AT FWD GALLEY AREA 2022-517262 / [01] REPLACED LOWERED CEILING PANEL CENTER LH BATTETY PACK AT FWD GALLEY AREA IAW B737-700 AMM 33-51-06-960-805 TEST IS OK;[02] CERTIFIED WORK PERFORMED.SDR SWAA2022101156798None · missingR1 DOOR LOWER EXIT SIGN IS NOT MULTI LANGUAGE. / [01] REMOVED AND REPLACED R1 DOOR LOWER EXIT SIGN PER AMM 33-51-01;[02] INSPECTEDSDR SWAA2022101157473Battery Pack · inoperativeEMERGENCY LIGHTS INOP AT AFT CABIN AREA LEFT AND RIGHT SIDE / [01] REMOVED AND REPLACED BATTERY PACK M1673 PER AMM 33-51-06-960-805. TEST NORMAL.;[02] VERIFIED STEP 1SDR SWAA2022101056992Light · inoperativeEXTERNAL EMERGENCY LIGHT BY AFT SERVICE DOOR IS INOP EXTERNAL EMERGENCY LIGHT NEXT TO AFT SERVICE DOOR IS INOP / [01] REVAMPED EMERGENCY LIGHT BY AFT SERVICE DOOR IAW AMM 33-51-04SDR SWAA2022101057500Power Supply · poppedDURING PREFLIGHT FOUND C/B POPPED P18-3A10 CB; PASSENGER EMER CHGR L AFT / [01] R/R 2EA AFT AND 2EA LEFT POWER SUPPLY AND BATRY PACK IAW AMM 33-51-06SDR SWAA2022101058190Battery Pack · poppedDURING PREFLIGHT FOUND C/B POPPED P18-3A10 CB; PASSENGER EMER CHGR L AFT / [01] R/R 2EA AFT AND 2EA LEFT POWER SUPPLY AND BATRY PACK IAW AMM 33-51-06SDR SWAA2022101056961Battery Pack · inoperativeFWD ENTRY DOOR AND FWD CENTER EMERGENCY EXIT LIGHTS INOP / [01] REMOVED AND REPLACED BATTERY PACK IAW AMM 33-51-06 OPS CHECK GOOD<BR>REMOVED P/N D717-01-100 S/N 424313<BR>INSTALLED P/N AD-D717-01-100SWA S/N BN250674SDR SWAA2022101057033None · brokenOVERWING EXIT SIGN BROKEN / [01] REPLACED EXIT SIGN ASSY. PER AMM 33-51-01. OPS CK GOOD.
Back to JASC 3350