JASC 3350
Service difficulty reports · 225,886
Reports filed under 3350 · Emergency Lighting, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3350' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3350' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA2021012400111Lamp · inoperativeAISLE EMERGENCY LIGHT IS OUT AT SEAT 36G. REMOVED AND REPLACED AISLE EMERGENCY LIGHT LAMP. OPERATIONS CHECKS GOOD, IAW AMM 33-51-05.SDR WX0A2021012573630Power Supply · faultedOPERATIONAL TEST OF THE EMERGENCY LIGHTS FAULTS. EPSU (10WL)FWD L AND EPSU (13WL) AFT L/DEU (300RH7). ACCOMPLISHED T/S AS PER A320 TSM 33-51-00-810-836-A. FOUND FAULTY LIGHTS CIRCUIT ON AFT RT SLIDE/RAFT, AS PER TSM. REMOVED AND REPLACED EPSU (13WL), REF AMSDR WX0A2021012273631Power Supply · inoperativeSEE NR00728622 FOR ORIGINAL DISCREPANCY. EPSU 10WL INOPERABLE. REMOVED AND REPLACED FORWARD EPSU 10WL, PER A320 AMM 33-51-38 PB 401.SDR WX0A2021012273630Power Supply · inoperativeSEE NR00728622 FOR ORIGINAL WRITE UP. EPSU 13WL INOPERABLE. REMOVED AND REPLACED EPSU 13WL, PER A320 AMM 33-51-38. OPERATIONS CHECK BAD, ITEM REMAINS OPEN.SDR AALA202101229008Lamp · inoperativeAIRCRAFT WAS NOT GROUNDED. SLIDE EMERGENCY LIGHT AT DOOR 1L WON'T WORK. RELAMPED SLIDE EMERGENCY LIGHT, PER AMM 33-51-04.SDR DALA2021012200428Battery Pack · no testEPSU FAULT ON EMERGENCY LIGHT TEST. CORRECTIVE ACTION: FOUND LEFT SIDE EPSU BATTERY PACK BAD, REF A319 MM 33-51-38.SDR SIMA20210121001Bulb · inoperativeEMERGENCY LIGHT ON ROW 12A PSU PANEL INOPERABLE. C/A: R & R OVERWING EMERGENCY LIGHT BULB ON ROW 12A PSU PANEL, IN REF WITH EMB 145 AMM 33-50-07. OPERATIONS CHECK GOOD.SDR CALA2021012200072Battery · no testPERFORM EMERGENCY LIGHT OPERATION CHECK FOUND BATTERY DOOR R3 M3 3404 INOPERABLE. REPLACED M33404 EMERGENCY LIGHT BATTERY PACK INSTALLATION TEST FOUND NORMAL AT DR R3M, REF AMM 33-51-06 -960-802 REV 90.SDR CALA2021012200071Battery · inoperativePERFORM EMERGENCY LIGHT OPERATION CHECK FOUND BATTERY DOOR R4 M3 3408 INOPERABLE. REPLACED THE M33408 EMERGENCY LIGHT BATTERY PACK AT DR R4 INSTALLATION TEST FOUND NORMAL, REF AMM 33-5 1-06-960-802 REV 90.SDR SWAA2021012143725Battery Pack · inoperativeMULTIPLE EMERGENCY LIGHTS INOPERABLE. REMOVED AND REPLACED EMERGENCY LIGHT BATTERY PACK M1670, IAW AMM 33-51-06. OPERATIONS TEST OK.SDR 2021F00010Battery Pack · failedEMERGENCY BATTERY C/B ON P5 PANEL FOR L4 AND R4 DOORS POPS AFTER RESET. BATTERY PACK HAD A ELECTRICAL BURNT SMELL WHEN REMOVED.SDR 2021F00011Battery Pack · failedEMERGENCY BATTERY PACK FAILED TO ILLUMINATE EMERGENCY LIGHTS.SDR DALA2021012400457Bulb · incorrectEMERGENCY LIGHT ABOVE COCKPIT OBSERVERS SEAT ARE INOPERATIVE. MAINTENANCE FOUND INCORRECT BULB IN SECONDARY SOCKET AND IMPROPERLY WIRED TO SECONDARY SOCKET FOR EMERGENCY LIGHTS, RECONNECTED. SYSTEM OPERATION IS NORMAL.SDR IXXA20210124002Light · inoperativeDURING THE COURSE OF SCHEDULED MAINTENANCE CHECKS, TECHNICIAN IDENTIFIES EMERGENCY EXIT SIGN NEXT TO R1 DOOR INOPERATIVE. AIRCRAFT OUT OF SERVICE, WORK IN PROGRESS. CORRECTIVE ACTION PENDING.SDR YENA2021012200075Battery · no testFLT 1380, FLL-DCA. EPSU 11WL FAILED BAT CAP TEST. R & R EPSU BAT AT 11WL, IAW 320 MM 33-51-38. OPERATIONS CHECK GOOD.SDR YENA2021012200074Battery · no testFLT 1380, FLL-DCA. EPSU 10WL FAILED BAT CAP TEST. R & R EPSU BAT AT 10WL, IAW 320 MM 33-51-38. OPERATIONS CHECK GOOD.SDR YENA2021012200073Battery · no testFLT 1380, FLL-DCA. EPSU 13WL FAILED BAT CAP TEST. R & R EPSU BAT AT 13WL, IAW 320 MM 33-51-38. OPERATIONS CHECK GOOD.SDR SWAA2021012143679Battery Pack · failed2 EACH EMERGENCY LIGHTING BATTERY PACKS FAIL CAPACITY TEST. REMOVED AND REPLACED 2 EACH EMERGENCY LIGHTING BATTERY PACKS AT LOCATIONS MM01672 AND M01673, PER AMM 33-51-06 AND ENG DWG 33500005.SDR SWAA2021012143414Battery Pack · inoperativeFWD GALLEY EMERGENCY LIGHTS INOPERABLE. R & R EMERGENCY BATT PACK, PER AMM 33-51-06.SDR R61A2021012100090Light · wornPHOTOLUMINESCENT STRIP IN FRONT OF FWD WARDROBE IS WORN. R & R PHOTOLUMINESCENT STRIP.SDR MASA2021012000021Battery Pack · dischargedEMERGENCY LITES INOPERABLE, CHARGED EMERGENCY BATTERIES, OPERATIONS CHECK GOOD.SDR MASA2021012000020Bulb · inoperativePAX DR FL LEVEL EMERGENCY LIGHT (1) BULB INOPERABLE, RELAMPED.SDR MASA2021012000019Bulb · inoperativeFWD SERVICE DR FL LEVEL EMERGENCY LIGHT (1) BULB INOPERABLE, RELAMPED.SDR CALA2021012000068Light · crackedTHE RIGHT AFT FLOOR PROXIMITY LIGHT AT G9 FOUND CRACKED, REF NON- ROUTINE NR 9423472, SPEC NR B787-33-3 -0002. REPLACED THE RIGHT AFT FLOOR PROXIMITY LIGHT AT G9. PERFORMED INSTALLATION TEST OF EMERGENCY LIGHT THE RESULT WAS ''SATIS'', REF AMM 33-51-06-00A-7SDR CALA2021012000067Light · brokenTHE LEFT FWD, RIGHT FWD AND RIGHT AFT FLOOR PROXIMITY LIGHT AT DOOR 1 OFCR PANEL FOUND BROKEN, REF NON-ROUTINE NR 9423470, SPEC NO.B787-33-3-0002. REPLACED THE LEFT FWD, RIGHT FWD AND RIGHT AFT FLOOR PROXIMITY LIGHT AT DOOR 1 OFCR. PERFORMED INSTALLATION TESSDR CALA2021012000066Light · crackedTHE LEFT AFT FLOOR PROXIMITY LIGHT AT G9 FOUND CRACKED, REF NON- ROUTINE NR 9423473, SPEC NO.B787-33-3 -0002. REPLACED THE LEFT AFT FLOOR PROXIMITY LIGHT AT G9. PERFORMED INSTALLATION TEST OF EMERGENCY LIGHT THE RESULT WAS ''SATIS'', REF TO AMM 33-51-06-00A-SDR CALA2021012000065Light · crackedTHE RIGHT AFT FLOOR PROXIMITY LIGHT AT G5 GALLEY FOUND CRACKED, REF NON-ROUTINE NR 9423471, SPEC NO. B787-33-3-0002. REPLACED THE RIGHT AFT FLOOR PROXIMITY LIGHT AT G5 GALLEY. PERFORMED INSTALLATION TEST OF EMERGENCY LIGHT, THE RESULT WAS ''SATIS'', REF TO ASDR CALA2021012000064Light · crackedTHE WALL-MOUNTED FLOOR PROXIMITY LIGHT BESIDE CANTER ATTENDANT SEAT FOUND CRACKED, REF NON-ROUTINE NR 9423474, SPEC NO.B787-33-3-0002. REPLACED THE WALL-MOUNTED FLOOR PROXIMITY LIGHT BESIDE CENTER ATTENDANT SEAT. PERFORMED INSTALLATION TEST OF EMERGENCY LIGHSDR CALA2021012000063Light · crackedTHE WALL-MOUNTED FLOOR PROXIMITY LIGHT BESIDE CANTER ATTENDANT SEAT FOUND CRACKED, REF NON-ROUTINE NR 9423474, SPEC NO.B787-33-3-0002. REPLACED THE WALL-MOUNTED FLOOR PROXIMITY LIGHT BESIDE CENTER ATTENDANT SEAT. PERFORMED INSTALLATION TEST OF EMERGENCY LIGHSDR CALA2021012000060Lamp · inoperativeEMERGENCY LIGHTS AT SEAT 9ABC INOPERABLE. OVERHEAD BIN NR 32 LIGHT INOPERABLE, RELAMPED EMERGENCY LIGHTS, OPERATIONS NORMAL.SDR SWAA2021022244587Lens · missingMISSING EMERGENCY LIGHT LENS ON OVERHEAD BIN 4RH SIDE AT PASSENGER CABIN (1 EA) / INSTALLED EMERGENCY LIGHT LENS ON OVERHEAD BIN 4RH SIDE AT PASSENGER CABIN (1EA) IAW B737-700 AMM 33-51-03-960-801SDR KCSA202101191003Light · inoperativeL313 EMERGENCY LIGHT DOORWAY WILL NOT ILLUMINATE.SDR SWAA2021012143502Battery Pack · failedEMERGENCY LIGHT BATTERY PACKS AT FOLLOWING LOCATIONS FAILED CAPACITY CHECK M1675; M1673; M1672. R & R EMERGENCY LIGHT BATTERY PACKS AT M1675; M1673; M1672, PER AMM 33-51-06.SDR SWAA2021012143321Light · faultedRT FWD EMERGENCY EXIT SIDEWALL LIGHT REMAINS BRIGHT (CABIN INTERIOR ILLUM BOEING SKY INTERIOR PHOTOLUMINESCENT). DMA NR 0427828. R & R LIGHT ASSEMBLY AT FWD RT EMERGENCY EXIT, PER AMM 33-21-00 CL 84199.SDR R61A202101210090Connector · unsecureCOCKPIT EMERGENCY LIGHT DOESN'T WORK. INSPECTED AND FOUND TO BE A BAD CONNECTION OF LIGHT CONNECTOR. RESECURED CONNECTOR.SDR GTIA2021012135556Battery Pack · no testEPSU BATTERY 13WL FAILS BITE TEST. R & R EPSU BATTERY 13WL, IAW 33-51-38-400-002-A. OPERATIONS CHECK GOOD.SDR CREATED, PER GMM 44.4.3.SDR DALA2021012000376Battery Pack · no testASPSU BATTERY NR 01 FAULT AFTER TEST. CORRECTIVE ACTION: R & R ASPSU BATTERY NR 02, PER A330 AMM 52-71.SDR DALA2021012000359Battery Pack · inoperativeDURING INSPECTION FOUND LEFT OVERWING EMERGENCY SIGN WONT COME ON. R & R LT OVERWING BATTERY PACK, PER B737 AMM 33-51. SIGNS COMES ON, OPERATIONS NORMAL.SDR DALA2021011900345Battery Pack · inoperativeTHE FRONT OVERWING EMERGENCY EXIT LIGHTS WERE FOUND TO BE INOPERATIVE. THE LIGHTS DIRECTLY OVER THE EXITS AND THEY WERE FOUND ON THE SERVICE CHECK. MAINTENANCE REPLACED THE BATTERY PACK B5-230, PER B717 AMM 33-51. OPERATIONAL TEST WERE GOOD.SDR DALA2021011900335Power Supply · inoperativeEXTERIOR EMERGENCY EXIT LIGHTS AT DOOR L2, L3 AND R3 ARE INOPERATIVE. MAINTENANCE REPLACED THE POWER SUPPLY AND BATTERY ASSEMBLY M6759. SYSTEM OPERATION IS NORMAL.SDR WX0A2021011973628Epsu · faultedEPSU TEST SHOWS BATTERY (10WL) FAULT. REMOVED AND REPLACED BATTERY (10WL), IAW AMM 33-51-38 PB 401. OPERATIONS CHECK GOOD.SDR I5EA2021011900006Battery Pack · no testR1 EMERGENCY LIGHT INOPERABLE. REMOVED AND REPLACED BATTERY PACK M1674. OPERATIONS CHECK GOOD, IAW B737-400 AMM 33-51-02.SDR I5EA2021011900005Battery Pack · no testEMERGENCY LIGHTS INOPERABLE ABOVE L2 AND AT FLOOR LEVEL AROUND R2 DOOR. REMOVED AND REPLACED AFT RT BATTERY PACK. OPERATIONS CHECK NORMAL, IAW B737-400 AMM 33-51-51, NO DEFECTS NOTED.SDR MYWA202102240003Power Supply · inoperativeEMERGENCY LIGHTS AT R/H OVERWING EXIT INOP RESOLUTION DESCRIPTION: REMOVED AND REPLACED BATTERY CHARGER ASSY AT 12 FED IAW B737-800 M/M 33-51-06 OPS CHECK NORMALSDR J7SA2021012600268Power Supply · malfunctionedDISCOVERED EMERGENCY LIGHTS BLINKING RAPIDLY. REMOVED AND REPLACED INOPERATIVE AFT EMERGENCY POWER SUPPLY WITH AN INSPECTED POWER SUPPLY, IAW PHENOM 300 AMM 33-52-01. OPERATIONS CHECK GOOD. P/N 6450LS-00; S/N 001599.SDR DALA2021012500478Light · inoperativeAFT CREW REST EMERGENCY LIGHT INOPERATIVE. MAINTENANCE REPLACED LIGHT. MCO/PLAC REMOVED. SYSTEM OPERATION IS NORMAL.SDR J7SA2021012200264Light · malfunctionedDISCOVERED EMERGENCY LIGHTS BLINKING RAPIDLY. REMOVED AND REPLACED FWD EMERGENCY AND AFT EMERGENCY BATTERIES WITH INSPECTED UNITS, AS REQUIRED. OPERATIONS CHECKS GOOD, NO DEFECTS NOTED, REF EMB AMM 33-51-01. FWD P/N 6450LS-00; S/N 001432; AFT P/N 6450LS-00;SDR SWAA2021012142822Battery Pack · inoperativeLT FORWARD EMERGENCY EXIT EXTERNAL LIGHT WILL NOT ILLUMINATE. REMOVED AND REPLACED LT FORWARD EMERGENCY LIGHT BATTERY PACK, REFERENCE AMM 33-51-06. OPERATIONS CHECK GOOD.SDR CALA2021012000056Battery · inoperativePERFORM EMERGENCY LIGHT OPERATION CHECK FOUND EMERGENCY LIGHT BATTERY (DOOR R1 M33094/R3 M33404/R4 M33408) TOTAL 3 EA INOPERABLE. REFER NON-ROUTINE NR 9422420 SPEC NR B777-33-3-7030. REPLACED M33094 M33404 M33408 EMERGENCY 1-06-960-802 REV 90 R1 P/N ON AD-D7SDR DALA2021011900323Guard · inoperativeEMERGENCY LIGHT SWITCH GUARDED FUNCTION INOPERATIVE. MAINTENANCE FOUND 2 SPRINGS MISSING. REPLACED OVERHEAD EMERGENCY LIGHT SWITCH GUARD. SYSTEM OPERATION IS NORMAL.
Back to JASC 3350