SDR R61A2020062300535Power Supply · inoperativeEMERGENCY EXIT LIGHTS IN AFT GALLEY AREA DO NOT ILLUMINATE. R&R EMERGENCY LIGHT POWER UNIT ABOVE AFT SERVICE DOOR.SDR SWAA2020062593868Battery Pack · inoperativeL1 DOOR EMERGENCY EXIT LIGHT INOPERATIVE. R & R THE L1 DOOR EMERGENCY LIGHT BATTERY PACK IAW AMM 33-51-06, OPS CHECKED GOOD.SDR AALA202006259001Battery Pack · dischargedAIRCRAFT WAS NOT GROUNDED: LEFT EMERGENCY POWER SUPPLY BATTERY PACK AT BS 727 INOPERATIVE. REPLACED BATTERY PACK AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 33-51-06.SDR AALA2020062549024Power Supply · defectiveAIRCRAFT NOT GROUNDED. EMERGENCY POWER SUPPLY UNIT SYSTEM TEST ON CIDS1 SHOWS FAULTS. REMOVED AND REPLACED EMERGENCY POWER SUPPLY UNIT BATTERIES AT LOCATIONS 10WL (AALA202006239002) AND 11WL (AALA202006249024) PER AMM 33-51-38.SDR AALA2020062539002Battery · defectiveAIRCRAFT NOT GROUNDED. EMERGENCY POWER SUPPLY UNIT SYSTEM TEST ON CIDS1 SHOWS FAULTS. REMOVED AND REPLACED EMERGENCY POWER SUPPLY UNIT BATTERIES AT LOCATIONS 10WL (AALA202006239002) AND 11WL ( AALA202006249024) PER AMM 33-51-38.SDR SWAA2020062493744Charger · inoperativeMID LEFT THREE EMERGENCY LIGHT OUT. / R&R PACK CHARGER ASSY IAW AMM 33-51-06 OPS CHECK GOODSDR DALA2020062322505Battery Pack · inoperativeDURING INSPECTION, FOUND ROW 19 TO 22 LED EMERGENCY LIGHTS INOPERATIVE. R & R THE BATTERY PACK ASSY M1617 IAW 33-51. OPS CHECKED GOOD.SDR AALA2020062329017Battery Pack · faultyAIRCRAFT WAS GROUNDED. EMERGENCY POWER SUPPLY UNIT BATTERY FORWARD L ERROR DURING LIGHT EMERGENCY TEST. REPLACED FORWARD LEFT EMERGENCY POWER SUPPLY UNIT BATTERY AND OPS TEST GOOD PER AMM 33-51-38.SDR AALA202006239001Power Supply · inoperativeAIRCRAFT IN BASE MAINTENANCE - EPSU (EMERGENCY POWER SUPPY UNIT) 13WL, AFT GALLEY, INOPERATIVE. REMOVED AND REPLACED EPSU 13WL PER AMM TASK 33-51-38-400-001-A. PERFORMED SATISFACTORY OPERATIONAL CHECK PER AMM TASK 33-51-00-710-001-A.SDR SIMA202006221002Inverter · failedCENTER AISLE FWD EXIT IDENTIFIER SIGN INOP. REMOVED AND REPLACED NR 6 EMERGENCY LIGHT DC/AC INVERTER IAW AMM 33-50-11. OPC GOOD.SDR SIMA202006221003Unknown · malfunctionedEMERG LIGHTS NOT ARMED AFTER DOOR CLOSED RECYCLED SWITCH CORRECTS MULTIPLE OCCURRENCE OVER 2 FLIGHTS. PERFORMED EMER LIGHTS OPERATIONAL CHECK IAW AMM 33-50-00 CND FAULT, SYSTEM OPERATES AS REQUIRED, ACFT RELEASED FOR SERVICE.SDR SIMA202006221001Light · fadedPCR EMERGENCY FLOOR STRIP INBD FWD CLOSET FADED (FOUND DURING CONFORMITY). REMOVED AND REPLACED EMERGENCY FLOOR STRIP INBD FWD CLOSET IAW AMM 33-50-21.SDR FDEA202006201300Warning Message · false activationEMER LT BAT 1 LOW ON PREFLIGHT PERFORMED OPS CHECK OF EMERGENCY LIGHTS REF MD-10-30 AMM 33-50-00-5-0. OPS CHECK GOOD; OK FOR SERVICE.SDR SWAA2020072295391Light · crazedCRAZING IN FIVE STRIP PHOTOLUMINESCENT FLOOR PROXIMITY LIGHTING LT AT PASSENGER CABIN. REPLACED STRIP PHOTOLUMINESCENT FLOOR PROXIMITY LIGHTING IAW DWG 33500007.SDR SWAA2020072295392Light · crazedCRAZING IN STRIP PHOTOLUMINESCENT FLOOR PROXIMITY LIGHTING RH AT PASSENGER CABIN (5 EA) / REPLACED STRIP PHOTOLUMINESCENT FLOOR PROXIMITY LIGHTING RH AT PASSENGER CABIN (5 EA) IAW DWG 33500007SDR J7SA2020070600203Battery · faultyDURING FLIGHT, EMERGENCY LIGHTS FLICKERING ON AND OFF IN ARM POSITION. TROUBLESHOT SYSTEM. FOUND NR 1 EMERGENCY BATTERY FAULTY. REMOVED AND REPLACED NR 1 AND NR 2 EMERGENCY BATTERY IAW AMM 33-52-01 AND 33-52-11. NR 1 P/N OFF: 6450LS-00 S/N OFF: 001098 P/N ONSDR SWAA2020062993648Power Supply · inoperativeFWD SERVICE DOOR EMERGENCY SLIDE LIGHT WAS OUT. REMOVED AND REPLACED THE POWER SUPPLY M1674 IAW AMM 33-51-06-960-805. PERFORMED A GOOD TEST IAW AMM 33-51-06-960-805, STEP 4S.SDR DALA2020062622513Power Supply · inoperativeFORWARD CABIN EMERGENCY EXIT SIGNS ARE INOPERATIVE. MAINTENANCE REPLACED L1 DOOR POWER SUPPLY. SYSTEM OPERATION IS NORMAL.SDR DALA2020062622512Charger · inoperativeEMERGENCY LIGHTS AT SEATS 1A-4A AND 33GF - 38GF ARE INOPERATIVE. REPLACED CHARGER ASSEMBLY M736, ALSO BATTERY AND CHARGER ASSEMBLY M732. SYSTEM OPERATION IS NORMAL.SDR DALA2020062402508Battery Pack · dischargedDURING INSPECTION FOUND EMERGENCY LIGHTS WILL NOT ILLUMINATE IN FWD LT CABIN. REMOVED AND REPLACED BATTERY PACK POWER SUPPLY PER AMM 33-51, OPS CHECK GOOD.SDR SWAA2020062493573Lamp · inoperativeLH OVERWING EMERGENCY LIGHT INOP / RELAMPED LH OVERWING EMERGENCY LIGHT IAW AMM 33-51-05SDR UIEA2020062201335Lens · damagedL1 DOOR EMERGENCY LIGHT LENS DAMAGED (NON-ESSENTIAL EQUIPMENT & FURNISHINGS(NEF) (120 DAYS)(NEW NEF 2ND QTR 2020). REMOVED AND REPLACED MISSING LIGHT LENS PER AMM 33-51-03. THIS CLEARS MDDR 130024. PLACARD REMOVED.SDR FDEA2020062301300Battery · low voltageEMER LIGHT BAT 1 LOW ON PREFLIGHT.SDR ASAA2020062302828Battery Pack · inoperativeALL CABIN EMERGENCY LIGHTS INOPERATIVE EXCEPT FWD GALLEY AND AFT GALLEY. GROUNDED - YES. REMOVED AND REPLACED THE BATTERY PACKS LOCATION M1670, M1671, M1674, M1676, M1694, M1695 AND M2337. OPS CHECKED GOOD IAW AMM 33-51-06.SDR DALA2020062322504Charger · inoperativeDURING INSPECTION, FOUND THE RT AFT OVERWING ESCAPE LIGHT AND RT OVERWING ESCAPE GROUND LIGHT INOPERATIVE. FOUND M1670 EMERGENCY EXIT LIGHT CHARGER ASSY FAILED. R & R M1670 IAW AMM 33-51. OPS CHECKED GOOD.SDR SWAA2020062393844Lens · detachedTHE EMERGENCY EXIT SIGN COVER AT THE OVERWING LEFT SIDE EXIT IS DETACHED FROM THE LIGHT SOURCE LOCATION. REINSTALLED THE LENS IAW SIPSDR R61A2020062300536Power Supply · inoperativeL1 DOOR EMERGENCY LIGHTS DON'T COME ON WHEN MOVING SWITCH IN COCKPIT TO ON POSITION. R&R NR 2 EMERGENCY LIGHT POWER UNIT.SDR R61A2020062300534Power Unit · inoperativeEMERGENCY LIGHTS IN COCKPIT INOP. R&R NR 1 ELPU PER AMM 22-50-01.SDR SIMA202006220001Inverter · failedMAIN DOOR LOWER EMERGENCY EXIT SIGN INOP. REMOVED AND REPLACED NR 1 EMERGENCY BATTERY IAW AMM 33-50-04-000-801-A AND 33-50-04-400-801-A, AND 33-50-04-000-802-A AND 33-50-04-400-802-A. NO FIX, RAR INVERTER 1 IAW AMM 33-50-11-000-801-A AND 33-50-11-400-801-A. SDR SIMA202006220002Inverter · failedGALLEY OVERHEAD EMERGENCY LIGHT INOP. REMOVED AND REPLACED NR 1 EMERGENCY BATTERY IAW AMM 33-50-04-000-801-A AND 33-50-04-400-801-A, AND 33-50-04-000-802-A AND 33-50-04-400-802-A. NO FIX, RMOVED AND REPLACED INVERTER 1 IAW AMM 33-50-11-000-801-A AND 33-50-11SDR AALA2020062219008Power Supply · inoperativeAIRCRAFT IN BASE MAINTENANCE, EPSU (EMERGENCY POWER SUPPLY UNIT) 12WL IN PASSENGER CABIN INOPERATIVE. REMOVED AND REPLACED EPSU 12WL PER AMM TASK 33-51-38-400-001-A. PERFORMED OPERATIONAL CHECK PER AMM TASK 33-51-00-710-001-A, CHECKED OKAY. BONDING TEST OKASDR AALA2020062219007Power Supply · faultyAIRCRAFT IN BASE MAINTENANCE, EPSU (EMERGENCY POWER SUPPLY UNIT) AT L2 (15WL) FAULT LIGHT ON. REMOVED AND REPLACED L2 EPSU (15WL) PER AMM 33-51-38, OPERATIONAL CHECK OKAY.SDR DALA2020062202492Power Supply · inoperativeTHE EMERGENCY LIGHTS AT WING EXIT DOORS WERE FOUND TO BE INOPERATIVE. MAINTENANCE REPLACED THE BATTERY POWER SUPPLY IN REFERENCE TO B717 AMM 33-51. OPERATIONAL CHECK WAS GOOD. (LP #7080575)SDR VNAA2020062111102Battery Pack · inoperativeROW 16 OVERHEAD AND LOWER ROW 16AC EMERGENCY LIGHTS NOT ILLUMINATING. REMOVED AND REPLACED EMERGENCY BATTERY PACK IAW 33-51-17-400-801 OPS CHECK GOOD.SDR REXA2020070600585Light · inoperativeFOUND EMERGENCY LIGHT EXTERIOR BY PAX DOOR INOP. REMOVED AND RELAMPED LIGHT BULB IAW AMM 33-51-15 OPS CHECK GOOD NO DEFECTS NOTED AT THIS TIME.SDR J7SA2020070600202Battery · faultedDISCOVERED EMERGENCY LIGHT BATTERY FAULT CAS MESSAGE AFTER POWER UP. TROUBLESHOT SYSTEM. REMOVED AND REPLACED NR 1 AND NR 2 EMERGENCY LIGHT BATTERIES. OPS CHECK GOOD. ALL WORK IAW AMM 33-51-01. NR 1 P/N OFF/ON: 6450LS-00 S/N OFF: 001627 S/N ON: 001875 NR SDR FDEA2020062391294Light · inoperativeRT EXTERNAL EMERGENCY LIGHT DOES NOT TEST. RELAMPED RT EMERGENCY SLIDE LIGHT REF AMM 33-51-06-2-1, OPS CHECKS GOOD.SDR SIMA2020062219002Light · inoperativePROX FLOOR EMERGENCY LIGHTING AT ROW 14A INOP. REMOVED AND REPLACED PROX FLOOR EMERGENCY LIGHTING AT ROW 14 IAW AMM 33-50-12 OPS CHECK GOOD.SDR SIMA2020062219001Light · inoperativeLT AFT OVERWING EMERGENCY LIGHT INOP. REMOVED AND REPLACED LT AFT OVERWING EMERGENCY LIGHT LAMP IAW 33-50-10, OPC GOOD IAW 33-50-00.SDR SWAA2020062293431Battery Pack · dischargedEMERGENCY LIGHTS LT OVER WING & 3RD FROM FWD ON CAPATIONS SIDE INOP. TROUBLE SHOT TO BATTERY PACK AT STA603 WL 212 LBL 67. R&R EMERGENCY LIGHT BATTERY PACK AT STA 603 WL 212 LBL 67 PER AM 33-51-06. OPS CHECK GOOD.SDR SWAA2020062293469Battery Pack · dischargedEMERGENCY OVERWING ESCAPE GROUND ILLUMIATION LIGHTS LT AND RT INOP NEEDS BATTERY PACK M1670 ROW 17 LT. INSTALLED EMERGENCY LIGHTS BATTERY PACK IAW AMM 33-51-06.SDR SWAA2020062293468Battery Pack · dischargedEMERGENCY LIGHT ON OVERHEAD BINS AT ROWS 7; 9; 14 INOP NEEDS BATTERY PACK M2335 ROW 7L. INSTALLED EMERGENCY BATTERY PACK (LIGHTS) IAW AMM 33-51-06.SDR SWAA2020062293366Battery · dischargedEMERGENCY LIGHTS ON CAPTAIN'S SIDE UPPER FIRST 2 INOP TROUBLE SHOT TO BATTERY PACK AT FS 500C +7 (ROW 8). R&R EMERGENCY LIGHTS BATTERY AT FS 500C +7 WL 213 LBL 67 PER AMM 32-51-06 OPS CHECK GOOD.SDR SWAA2020062293871Cover · looseOVERHEAD EXIT SALIDA SIGN COVER IS LOOSE. RE-SECURED OVERHEAD EXIT-SALIDA SIGN COVER PER SIP.SDR SWAA2020062293758Light · inoperativeMULTIPLE EMERGENCY LIGHTS INOP THROUGHOUT CABIN. ROUBLE SHOT CABIN EMERGENCY LIGHTS; REPLACED BATTERY FWD OF RH EMERGENCY EXIT DOOR IAW AMM 33-51-06-960-805 STEP 4.(3);(4). OPS CHECK GOOD. ATAG:ET1488SDR AALA2020062219009Power Supply · wrong partAIRCRAFT IN BASE VISIT: WHILE ACCOMPLISHING J/C 26C00033004 FOUND AFT DOOR ESPU WOULD NOT TEST. FOUND ESPU HAD WRONG EFFECTIVITY IN IT. REPLACED ESPU PER AMM 33-51-38.SDR CALA2020062001020Power Supply · no testEMERGENCY EXIT LIGHT TEST FAILED, EPSU AT LT AFT POSITION. TRIED TESTING AT ESPU NO REPONSE. REPLACED ESPU REF AMM 33-51-38-000-001-A & 33-51-38-400-001-A OPS CHECKED OK. ROTABLE PARTS CHANGE WAS INDICATED - TT # 1103732 SN OFF 8072 POWER SUPPLY, C OFF 31SDR FDEA2020061981282Charger · inoperativeL1 EXTERIOR SLIDE EMERGENCY LIGHT INOP. REMOVED AND REPLACED BATTERY HOLDER ASSY (BATTERY) AND CHARGER ASSY FOR THE LT EXTERIOR SLIDE EMERGENCY LIGHT. OPS CHECKS GOOD IAW AMM 33-51-07-2-0. A/C OK TO CONTINUE.SDR ASOA2020062685020Battery Pack · inoperativeDURING MX INSPECTION THE #1 EMERGENCY LIGHT BATTERY PACK WILL NOT ILLUMINATE LIGHTS. MX R&R #1 EMERGENCY LIGHT BATTERY WITH OPERATIONAL CHECK GOOD.SDR ASOA2020062685019Battery Pack · inoperativeDURING MX INSPECTION THE #3 EMERGENCY LIGHT BATTERY PACK WILL NOT ILLUMINATE LIGHTS. MX R&R #3 EMERGENCY LIGHT BATTERY WITH OPERATIONAL CHECK GOOD.
Back to JASC 3350