JASC 3350
Service difficulty reports · 225,886
Reports filed under 3350 · Emergency Lighting, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3350' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3350' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2020061190153Battery Pack · dischargedAFT SECTION OF AIRCRAFT INTERIOR/EXTERIOR EMERGENCY LIGHTS INOP. REMOVED AND REPLACED AFT GALLEY (SECTION) BOTH EMERGENCY LIGHTS BATTERY PACKS OPS CHECK GOOD REFERENCE AMM 33-51-06.SDR SWAA2020061090168Sign · brokenLOWER EMERGENCY FORWARD ENTRY DOOR EXIT SIGN BROKEN. REMOVED + REPLACED FWD ENTRY DOOR LOWER EE FIXURE. OPS CHECK GOOD. REF AMM 33-51-00.SDR AALA2020061099001Lens · defectiveAIRCRAFT NOT GROUNDED - EMERGENCY LIGHTS TEST, BUSINESS CLASS BAR, 2ND LIGHT FROM RIGHT INOP. REPLACED LENS ASSEMBLY PER AMM 33-51-00, OPERATIONAL CHECK GOOD.SDR R61A2020061000522Power Supply · inoperativeMULTIPLE FWD EMERGENCY LIGHTS INOP. R&R #1 FWD EMERGENCY LIGHT POWER UNIT IAW AMM 33-50-01.SDR AALA2020060989012Power Supply · faultedAIRCRAFT WAS GROUNDED - DURING FUNCTIONAL TEST FAULT WARNING FOR THE L1 DOOR, EPSU (EMERGENCY POWER SUPPLY UNIT) 10WL, / DEU B (DECODER/ENCODER UNIT) 300RH1 DISPLAYED. REMOVED AND REPLACED EMERGENCY POWER SUPPLY UNIT (SEE AALA202006089012) AND SECURED ELECTRICSDR AALA2020060989010Power Supply · faultedAIRCRAFT WAS GROUNDED. LEFT HAND OVER WING EXIT EMERGENCY POWER SUPPLY UNIT DISPLAYED , "UNIT FAULT" DURING TEST TASK 20A OF CARD 26L00005044. REPLACED EMERGENCY POWER SUPPLY UNIT AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 33-51-38.SDR DALA2020060802456Battery Pack · dischargedDURING INSPECTION FOUND EMERGENCY SEAT AISLE LIGHTS INOPERATIVE AT SEATS 10D-14D. R+R EMERGENCY BATTERY PACK FOR SEATS 10D-14D IAW AMM 33-51. OPS CHK GOOD.SDR SWAA2020061090501Fuse · inoperativeLT FWD ENTRY DOOR SLIDE EMERGENCY ESCAPE LIGHT. WILL NOT ILLUMINATE DURING TEST / REMOVED AND REPLACED FUSE IN POWER SUPPLY M1675 IAW AMM 33-51-06 OPS CHECKED GOOD.SDR UIEA2020061091248Battery Pack · inoperativeFOUND EMERGENCY LIGHT BATTERY PACK M5169 INOPERATIVE. IAW AMM 33-51-04-902-001 REV 98, REPLACED M5169 EMERGENCY LIGHT BATTERY PACK. IAW AMM 33-51-04-902-001-001, REV 98. PERFORMED AN EMERGENCY LIGHT TEST, AND THE RESULT WAS SATISFACTORY.SDR R61A2020060900521Power Supply · inoperativeEMERGENCY LIGHTS FLICKERING AND 2 LIGHTS STAY ON DIMMED WITH EMERGENCY LIGHTS TURNED OFF. R&R EMERGENCY LIGHT POWER UNIT, ALL CHECKS GOOD.SDR AALA202006089006Cover · detachedAIRCRAFT NOT GROUNDED - R2 EXIT SIGN, COVER FELL OFF. RE-INSTALLED R2 EXIT SIGN COVER PER AMM TASK 33-51-01-201-410-001.SDR MASA2020060610099Battery · dischargedROW 13 LWR LVL EMERG EXIT SIGNS INOP. CHARGED BATTERY.SDR SWAA2020061690103Battery Pack · inoperativeFWD GALLEY LEFT EMERGENCY LIGHTS BATTERY PACK INOPERATIVE. R & R THE BATTERY PACK IAW AMM 31-51-06. OPS CHECKED GOOD IAW 31-51-21, AND 31 51-11.SDR VNAA2020060911101Battery Pack · dischargedDURING OVERNIGHT MAINTENANCE IT WAS FOUND THAT THE EMERGENCY BATTERIES WOULD NOT HOLD A CHARGE. MAINTENANCE REMOVED AND REPLACED THE BATTERIES.SDR SWAA2020060989870Battery Pack · inoperativeOVERHEAD EMERGENCY EXIT LIGHT ON L1 DOOR INOPERATIVE. R & R M1674 BATTERY PACK & CHARGER BASE. OPS CHECKED GOOD IAW AMM 33-51-06.SDR SWAA2020060990164Battery Pack · dischargedFWD ESCAPE SLIDE EMERGENCY LIGHT RT INOP. R&R'D BATTERY PACK M1674 PER MM 33-51-06; OPS CHECK GOOD.SDR SWAA2020060990441Battery Pack · dischargedFWD PASSENGER LIGHTS INOP. R/R FWD GALLEY RT EMERGENCY LIGHTING BATTERY PACK IAW AMM 33-51-06. OPS CK GOOD.SDR SWAA2020060990474Battery Pack · dischargedEMERGENCY EXIT LIGHTS FO SIDE STAY ON WITH SWITCH IN ARMED MODE. FOUND M1695 RT EMERGENCY CHARGER + BATTER PACK INOP. REPLACED CHARGER + BATTERY PACK PER AMM 33-51-06.SDR J7SA202006085001Light · malfunctionedDURING ROUTINE MAINTENANCE, DISCOVERED EMERGENCY LIGHTS REMAIN ON IN THE ARM POSITION. REMOVED FWD AND AFT POWER SUPPLIES AND INSTALLED TESTED POWER SUPPLIES. REF AMM 33-52. NO DEFECTS NOTED.SDR DALA2020060802455Light · inoperativeDURING INSPECTION FOUND EMERGENCY FLOOR LIGHT AT 30DEF INOPERATIVE. R/R LIGHT ASSY PER AMM 33-51. OPS CHECK NORMAL.SDR AALA202006089015Power Supply · faultedAIRCRAFT WAS GROUNDED:.EMERGENCY POWER SUPPLY FAILED TEST, SHOWED UNIT FAULT. REMOVED AND REPLACED EMERGENCY POWER SUPPLY UNIT PER TASK CARD 26C00033004.SDR AALA202006089014Battery Pack · faultedAIRCRAFT NOT GROUNDED. EMERGENCY POWER SUPPLY UNIT EMERGENCY BATTERY L FAULT DURING OPERATIONAL TEST FOR SLIDE CHANGE. REMOVED AND REPLACED L3 DOOR EMERGENCY BATTERY IN THE OVERHEAD PANEL PER AMM 33-51-38. SATISFACTORY OPERATIONAL CHECK ACCOMPLISHED.SDR AALA2020060879006Battery Pack · faultedAIRCRAFT NOT GROUNDED. EMERGENCY POWER SUPPLY UNIT EMERGENCY BATTERY L FAULT DURING OPERATIONAL TEST FOR SLIDE CHANGE. REMOVED AND REPLACED L1 DOOR EMERGENCY BATTERY IN THE OVERHEAD PANEL PER AMM 33-51-38. SATISFACTORY OPERATIONAL CHECK ACCOMPLISHED.SDR AALA2020060879005Light · inoperativeAIRCRAFT NOT GROUNDED. EMERGENCY EXIT LIGHT AT 9C INOPERATIVE. REMOVED AND REPLACED SEAT 9C SEAT MOUNTED EMERGENCY EXIT LIGHT AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER CMM 25-22-52.SDR SIMA2020060805004Charger · failedEMERGENCY EXIT LIGHT ABOVE FA SEAT INOP. TROUBLESHOT IAW FIM 33-50-00. REMOVED AND REPLACED NR 1 BATTERY AND CHARGER. OPC GOOD IAW AMM 33-50-04. EMERGENCY LIGHTING BATTERY P/N 2013-1ASMI S/N 104945.SDR SIMA2020060805005Light · inoperativeLT O/W EMER LIGHT INOP. REMOVED AND REPLACED LT O/W EMER LIGHT IAW AMM 33-50-10.SDR GTIA2020060855193Battery Pack · no testEPSU 13WL LEFT FAULTED DURING EMERGENCY LIGHT TEST.-REMOVED & REPLACED EPSU 13WL BATTERY IAW A319 AMM 33-51-38. OPS CHECKS GOOD IAW A319 AMM 33-51-00-710-001.SDR DALA2020060502452Battery Pack · no testEMERGENCY EXIT LIGHTS/SIGNS AT 3L/4L DOORS FAIL DURING LIGHTS TEST REPLACED BATTERY PACKS AT 3L/4L DOORS PER B777 AMM 33-51 ALL LIGHTS NOW CK GOODSDR DALA2020060802451Power Supply · inoperativeTHE CEILING EMERGENCY LIGHTS IN THE FIRST CLASS CABIN TO ROW 14 ARE INOPERATIVE. MAINTENANCE REPLACED THE EMERGENCY LIGHT BATTERY POWER SUPPLY B5-227 IAW B717 AMM 33-51. PERFORMED OPERATIONAL CHECK AND ALL LIGHTS CHECK GOOD.SDR IPXA2020060556171Light · inoperativeINSPECTION TYPE:N/A FOUND EMERGENCY CEILING LIGHT NOT WORKING. REMOVED EMERGENCY CEILING LIGHT IAW AMM 33-51-11-002-008 REV 130.01. INSTALLED AND TESTED EMERGENCY CEILING LIGHT IAW AMM 33-51-11-402-014 REV 130.01. ACCOMPLISHED FUNCTIONAL TEST OF EMERGENCY LIGHSDR DALA2020060502450Battery Pack · dischargedTHE OVERHEAD EMERGENCY LIGHTS, BETWEEN ROW 1-18, WERE FOUND TO BE INOPERATIVE DURING THE SERVICE CHECK. MAINTENANCE REPLACED BATTERY PACKS B5-118 AND B5-227 PER AMM 33-51. OPERATIONAL CHECK WAS GOOD.SDR HNAA2020070900190Inverter · inoperativeDURING RON FOUND FLOOR LIGHTS AT ROW 7 TO 12 ARE INOP. RR NR 5 EMERGENCY LIGHT POWER INVERTER IAW 33-50-01. THIS SUPERSEDES PREVIOUS SDR REPORT. THE PREVIOUS SDR REPORT HAS A MISTAKE ON NATURE OF CONDITION COLUMN.SDR SWAA2020060889875Battery Pack · dischargedDURING T/C 720-10-01 FOUND 2 BULB NOSE (PSU'S) EMERGENCY LIGHTS INOPERATIVE AT ROW 9-12 LT. R & R BATTERY PACK. OP'S CKD GOOD REF AMM 33-51-06.SDR SWAA2020060889936Fuse · inoperativeRT EMERGENCY EXIT SIDEWALL LIGHT IS INOP. R&R RT EMERGENCY EXIT LIGHT FUSE PER AMM 33-21-00.SDR CALA2020060801013Power Supply · inoperativeM2626 EMERGENCY POWER SUPPLY PUSH TO TEST BUTTON STICKS. JUST ABOVE SEAT 30ABC MOUNTED ON CEILING PANEL REMOVED AND REPLACED M2626 EMERGENCY POWER SUPPLY ASSY WITH SERVICABLE UNIT, RO 5021132. OPS CHECK GOOD REF AMM 33-51-01-960-806. OPS CHECK GOOD.SDR CALA2020060801012Battery Pack · dischargedEMERGENCY AISLE PATH LIGHTING INOP AT ROWS 27 THRU 34 T/S AISLE PATH LIGHTING, FOUND M2626, BATTERY PACK TO BE FAULTY, REMOVED AN REPLACE BATTERY PACK WITH SERVICABLE UNIT. RO 5158418 REF AMM 33-51-06-960-805.SDR SIMA202006054002Power Unit · inoperativeNR 2 EMERGENCY LIGHT POWER UNIT INOP. REMOVED AND REPLACED NR 2 EMERGENCY LIGHT POWER UNIT PER AMM 25-22-07. OPC GOOD.SDR JJBA202006054003Charger · inoperativeFORWARD EXTERNAL EMERGENCY LIGHTS FWD OF WING INOPERATIVE. REMOVED AND REPLACED NR 2 BATTERY CHARGER ASSEMBLY. REMOVED AND REPLACED BURNT OUT BULBS. OPS CHECK SAT.SDR AALA202006059001Battery Pack · failedAIRCRAFT WAS NOT GROUNDED. AFT EMERGENCY LIGHT BATTERY PACK FAILED FUNCTIONAL CHECK PER TASK CARD 08T21033001. REPLACED AFT EMERGENCY LIGHT BATTERY PACK PER AMM 33-51-06.SDR MASA2020060410098Light · inoperativeROW 18 CEILING FLOOD LIGHT INOP. PLACE ON MEL.SDR GTIA2020060435192Epsu · inoperativeBAT/ EPSU (11WL) EMER L FAILED OPS CHECK. REMOVED & REPLACED 11WL EPSU IAW AMM 33-51-38-000-001 & 33-51-38-400-001, SYSTEM OPS CHECKED GOOD IAW AMM 33-51-38-400-001 STEP 4D & 33-51-00-710-001 STEP 4A.SDR MASA2020060410097Light · inoperativeFLOOR LEVEL EMERG LIGHT BULBS OUT.SDR SWAA2020060989438Fuse · inoperativeRIGHT HAND OVER WING EXIT HATCH AFT EXIT LIGHT DOES NOT ILLUMINATE WITH EMERGENCY LIGHTS SWITCH SELECTED ON / REMOVED AIR RETURN GRILL TO ACCESS EMERGENCY EXIT POWER SUPPLY M1668 AND REPLACED F1 FUSE AND RE-INSTALLED EMERGENCY EXIT LIGHT BATTERY PACK ONTO M166SDR SWAA2020060989442Light · inoperativeEMERGENCY EXIT LIGHTS L1359 & L1189 AT LT OWE (INSIDE CABIN) HAVE BULBS OUT. REMOVED & REPLACED AND PERFORMED GOOD FUNCTIONAL TEST OF APPLICABLE EMERGENCY EXIT LIGHT BULBS FOR L1359 AND L1189 LIGHTS AT LT OWE (INSIDE CABIN) IAW AMM 33-51-01-960-801 STEP 2C (1SDR SWAA2020060889375Charger · intermittentEMERGENCY EXIT LIGHTS GO ON AND OFF IN THE FWD GALLEY AND ROW 4. R & R EMERGENCY BATTERY PACK CHARGER IAW AMM 33-51-06.SDR SWAA2020060889057Battery Pack · failedEMERGENCY LIGHT BATTERY PACK AT LOCATION M1672 FAILED. R&R EMERGENCY LIGHT BATTERY PACK AT LOCATION M1672 PER MM 33-51-06.SDR VNAA2020060711102Relay · failedGALLEY SERVICE DOOR EMERGENCY LIGHT AND 1D EMERGENCY LIGHTS AND 8D EMERGENCY LIGHTS ILLUMINATED IN THE OFF POSITION (DS173, DS158, DS341) - REPLACED RELAY K198 AND INSPECTED ALL ESPU'S AND ASSOCIATED WIRING AND FOUND NO DEFECTS. TAXIED AC TO SIMULATE TURBULENCSDR YENA202006030363Epsu · faultyFLT 284, MCO-JFK. EPSU EXTERNAL LOAD FAULT/INTERNAL LOAD FAULT DURING OPERATIONAL TEST OF THE EMERGENCY LIGHTING SYSTEM. PERFORMED TROUBLE SHOOTING IAW TSM 33-51-00-810-807-A FOR ESPU 13WL STOPPED AT STEP 7B. REQUIRES FURTHER TROUBLE SHOOTING. REF LOG PAGE 285SDR YENA202006030362Epsu · faultedFLT 284, MCO-JFK. EPSU EXTERNAL LOAD FAULT/INTERNAL LOAD FAULT DURING OPERATIONAL TEST OF THE EMERGENCY LIGHTING SYSTEM. PERFORMED TROUBLE SHOOTING IAW TSM 33-51-00-810-807-A FOR ESPU 13WL STOPPED AT STEP 7B. REQUIRES FURTHER TROUBLE SHOOTING. REF LOG PAGE 285SDR DALA2020060402449Charger · inoperativeL3 DOOR EXIT SIGN LIGHT INOP. ALL INTERIOR EXIT AND AISLE LIGHTS ASSOC W/ BP M11490 AT SEAT 41ABC INOP, BUT EXTERIOR SLIDE LIGHT (FLOOD LT) WORKS. REPLCD CHARGER/BATT. R/R FUSES ON M11490 IAW AMM 33-51. OPS CK GOOD.
Back to JASC 3350