JASC 3350
Service difficulty reports · 225,886
Reports filed under 3350 · Emergency Lighting, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3350' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3350' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2020041602271Light · inoperative(LOG 6342074) COCKPIT EMERGENCY LIGHT INOPERATIVE. R/R COCKPIT EMERGENCY DOME LIGHT PER AMM 33-14.SDR VNAA2020041611103Battery Pack · failedL/H MIDDLE EXTERIOR EMERGENCY LIGHT WILL NOT ILLUMINATE. FOUND MULTIPLE ADDITIONAL LIGHTS OUT IN THE INTERIOR OF THE AIRCRAFT. SUSPECT #2 BATTERY ISSUES. TROUBLESHOT AND FOUND #2 BATTERY TERMINAL WITH POOR INTERNAL CONNECTION DUE TO FLUCTUATING OUTPUT VOLTAGE.SDR SIMA2020041614006Light · inoperativeLH OVERWING EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED LH OVERWING EMERGENCY LIGHT ASSEMBLY IAW EMB 33-50-10-000-801-A AND 33-50-10-400-801-A. OPC GOOD. END.SDR SIMA2020041614005Inverter · inoperativeFLOOR PROXIMITY LIGHT STRIP #2 INOP-C/A-T/S LIGHT STRIP IAW EMB 145 FIM TASK 33-50-00-810-804-A FOUND ELECTRICAL CONNECTION DAMAGED ON STRIP #2 REMOVED AND REPLACED DAMAGED STRIP IAW EMB 145 AMM 33-50-12 NO FIX FOUND #2 INVERTER TO BE AT FAULT RAR INVERTER IAWSDR SWAA2020041541958Sign · looseOVERWING EMERGENCY EXIT CABIN CEILING SIGN IS LOOSE / RESECURED OVERWING EMERGENCY EXIT CABIN CEILING SIGN PER MM 33-51-00SDR DALA2020041502263Light · inoperativeRIGHT AFT OVER WING EXIT DOOR, HANDLE EMERGENCY LIGHT INOP, RELAMPEDSDR MASA2020041410158Light · inoperative18D LWR EXIT 1 BULB INOP
REPLACED BULBSDR MASA2020041410157Light · inoperativeROW 18 D FLR LVL EXIT SIGN/1 BULB INOP- RE-LAMPEDSDR MASA2020041410156Light · inoperativeEMER LTS INOP AT ROW 18- ALLOWED EMERGENCY LIGHTS TO CHARGESDR SWAA2020041741226Battery Pack · dischargedFWD ENTRY DOOR EMERGENCY EXIT LIGHTS INOP. / REMOVED AND REPLACED FWD ENTRY DOOR EMERGENCY LIGHT BATTERY PACK PER AMM 33-51-06. OPS CHECK NORMAL AT THIS TIME.SDR SWAA2020041741255Battery Pack · dischargedSEVERAL EMERGENCY LIGHTS INOP AFT R/H CABIN / REPLACED R/H AFT EMERGENCY BATTERY PACK IAW MM 33-51-06 CKS GOOD.SDR SWAA2020041741601Light · inoperativeEXTERNAL EMERGENCY LIGHT AFT OF R2 DOOR INOP / RE-LAMPED EXT. EMERGENCY LIGHT AFT OF R2 DOOR; OPS CHECK GOOD IAW AMM 33-51-04-960-801SDR SWAA2020041742689Battery Pack · inoperativeWHILE WORKING NRC U126132 FOUND BATTERY PACK M1675 INOP. / REMOVED; REPLACED AND PERFORMED GOOD OPS CHECK AT EMERGENCY LIGHT BATTERY PACK M1675 PER AMM 33-51-06-960-805.SDR IPXA2020041554205Battery · dischargedINSPECTION TYPE:N/AEMERGENCY LIGHTS INOPR&R EMERGENCY BATTERY PACK PER AMM 33-51-07-201 OPS CKS GOODSDR WX0A2020041573499Battery · dischargedEPSU BATTERY FIN# 13WL FAILED EPSU BAT CAP TEST / REPLACED EPSU BATTERY"SDR SIMA202004143007Power Supply · failed2ND AND 3RD FLOOR PROXIMITY LIGHTS ARE INOP-C/A-REMOVED AND REPLACED #2 EMERG PWR SUPPLY IAW EMB-140 AMM 33-50-04. OPC GOOD. EMERGENCY LIGHTING BATTERY P/N 2013-1A S/N 103861SDR DALA2020041302242Battery · discharged(LOG 7177206) L-2 DOOR EMERGENCY EXIT LIGHT AND AFT ISLE EXIT LIGHTS INOPERATIVE. REMOVED AND REPLACED M1673 POWER SUPPLY BATTERY PER B737 AMM 33-51. ALL LIGHTS OP'S CK'S GOOD.SDR DALA2020041302244Battery Pack · discharged(LOG 7043995) L1 ZONE EMERGENCY LIGHTS INOPERATIVE. R/R BATTERY PACK AND CHARGER (M16750 W/ SERVICEABLE UNITS PER B737 AMM 33-51.SDR CALA2020041300836Charger · inoperativeB777-33-3-7019: R/H DR4 EMER CEILING LT INOP. REF NR LP 9130178 LH DR3 POWER SUPPLY CHARGER REPLACED AND INSTALLATION TEST CARRI ED OUT RESULT NORMAL IAW AMM 33-51-06SDR ASOA202004133031Inverter · inoperativeDURING ROUTINE MAINTENANCE LEFT AND RIGHT OVERWING FORWARD EMERGENCY LIGHTS WERE FOUND INOPERATIVE. MAINTENANCE REPLACED THE #4 EMERGENCY LIGHT BATTERY INVERTER. OPERATIONAL CHECKS WERE GOOD.SDR SWAA2020041641252Battery Pack · dischargedAFT RIGHT DOOR EMERGENCY LIGHT AREA INOP. / R&R'D AFT RIGHT BATTERY PACK PER MM 33-51-06SDR SWAA2020041641253Battery Pack · dischargedAFT RIGHT DOOR EMERGENCY LIGHT AREA INOP / R & R'D AFT RIGHT BATTERY PACK PER MM 33-51-06 POS:AFT RT P/N OFF:D717-01-100 P/N ON:D717-01-100SWA S/N OFF:217195 S/N ON:52453SDR SWAA2020041641254Light · inoperativeAFT ENTRY EXTERIOR EMERGANCY LT INOP ( EXTERIOR EMER LT SYS ) / R&R AFT L/H ENTRY DOOR LIGHT FUSE ON POWER SUPPLY PER AMM 33-51-06. OPS CHK GOOD AT THIS TIME/ CL#76030SDR DALA2020041602267Battery Pack · dischargedSHIP 5647 DURING SVC CHK FOUND BANK OF EMERGENCY LIGHTS OUT FROM ROW 4A TO THE 2R DOOR REQ NEW BATTER PACK ASSY AT LOC M732. CORRECTIVE ACTION: R/R LOC M732 BATTERY PACK ASSEMBLY PER B757 AMM 33-51 CHKS GOOD. (6973419)SDR ASOA2020041624012Light · inoperativeIAH - FLIGHT 3985, DURING MAINTENANCE INSPECTION THE AISLE PATH LIGHT STRIP AT ROW 8-9 WAS FOUND TO BE INOPERATIVE. MAINTENANCE PLACED THE LIGHT STRIP ON MEL AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE. ON 04/15/20 IAH MAINTENANCE REMOVED AND REPLACED SDR SIMA2020041312001Inverter · failedEMERGENCY EXIT SIGN AT SEAT 3BC INOP-C/A-T/S ,REPLACEDAND REMOVED EXIT IDENTIFYER SIGN IAW EMB AMM 33-50-13-000-801-A ZND 33-50-13-400-801-A, NO FIX. REMOVED AND REPLACED # 2 EMERGENCY BATTERY IAW EMB AMM 33-50-04-000-801-A ND 33-50-04-400-801-A, NO FIX. RAR #SDR SIMA2020041312002Light · inoperativeAFT CEILING EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED AFT CEILING EMERGENCY LIGHT IAW EMB AMM 33-50-08-000-801-A AND 33-50-08-400-801-A. OPC GOODSDR SIMA2020041312003Light · inoperativeLH EXTERIOR EMERG LT BULB INOP-C/A-REMOVED AND REPLACED LH EXTERIOR EMERG LT BULB IAW AMM 33-50-10 OPS CHECK GOODSDR IPXA2020041354133Light · brokenINSPECTION TYPE:SEGL1 DOOR OVERHEAD EMERGENCY EXIT LIGHT CONTACT LOCKS BROKENREMOVED AND REPLACED EMERGENCY EXIT LIGHTSDR DALA2020041302240Battery Pack · discharged(LOG 7118943) RIGHT OVERWING EXIT AND AISLE LIGHTS INOPERATIVE AT SEATS 16D, 17D, 18D. TROUBLESHOT PER B737 AMM 33-51-06-200-801. REPLACED BATTERY PACK PER B737 AMM 33-51. EMERGENCY LIGHTS CHECK NORMAL.SDR CALA2020041300831Charger · inoperativeB777-33-3-7019: L/H DR3 EMER CEILING LT INOP REF NR LP 9130178 L/H DR 3 POWER SUPPLY CHARGER REPLACED AND INSTALLATION TEST CAR RIED OUT RESULT NORMAL IAW AMM 33-51-06SDR CALA2020041300830Battery · dischargedB777-33-3-7019 - R/H DR3 EMER EXIT SIGN INOP.REF NR LP 9130183 R/H DR3 POWER SUPPLY BATTERY REPLACED AND INSTALLATION TEST CARRIED OUT RESULT NORMAL IAW AMM 33-51-06.SDR AALA2020041419004Light · inoperativeAIRCRAFT NOT GROUNDED. EMERGENCY CEILING LIGHT (205WL) ROW 23 INOPERATIVE. REMOVED AND REPLACED EMERGENCY CEILING LIGHT AT ROW 23, PROGRAMMED CONNECTOR PN: E0052R8B3ASNE, AND BACKSHELL PN: ABS0638B08, NO HELP. SUPPLEMENTAL REPORT: REMOVED AND REPLACED EMERGESDR SWAA2020041541340Lens · missingCABIN EMERGENCY EXIT LIGHT LENS; NOT INSTALLED ON RH OVERHEAD BIN 8 - 9. / INSTALLED CABIN EMERGENCY EXIT AREA LIGHT LENS ON R/H OVERHEAD AISLE 8-9 AS PER AMM. 33-51-03-960-801 STEP 2.D.(1.C.). 59132U 12APR20SDR IPXA2020041554165Warning System · false activationINSPECTION TYPE:N/AEMER LIGHTS EICAS ADVISORY WITH THE LIGHT SW. IN THE ARMED POSITION DURING PRE FLIGHTFOUND EMER LIGHT TEST ON POSITION @ FLT DECK LIGHTNING PANEL RE-RESET EMER LIGHT TEST SW. AS PER AMM 33-50-00 OPS CHECK NOW OK. NIL EICAS ADVISORY MSG NOTEDSDR DALA2020041302239Battery · dischargedTHE L1 AND R1 OVERWING EMERGENCY EXIT SIGNS ARE INOPERATIVE. MAINTENANCE REPLACED THE BATTERY SUPPLY REF MD88 AMM 33-50. OPERATIONAL CHECK IS GOOD. THE AIRCRAFT IS OK FOR SERVICE. (LP #5497158)SDR K11A2020041101Power Supply · dischargedDURING A CHECK FOUND R1 & L1 DOOR EMERGENCY LIGHTING INOPSDR MASA2020041110154Light · inoperativePAX DOOR ENTRY EXIT SIGN 1 BULB INOP
REPLACED BULBSDR SIMA2020062541004Holder · brokenFIVE PROXIMITY LIGHT HOLDERS AND FIVE RT SIDEWALLS ARE BROKEN. R & R THE LIGHT HOLDERS AND THE RH SIDEWALLS IAW AMM 33-50-12.SDR SWAA2020041441335Battery Pack · dischargedAISLE LIGHT @ SEAT 9 & 11 ABC INOP (REPLACE EMERGENCY BATTERY PACK M1675) / RECHARGE BATTERY PACKS IAW AMM 33-51-06-610-802 PERFORMED EMERGENCY LIGHT OPERATIONAL TEST IAW 33-51-00-710-801. CHECK GOOD. AISLE LIGHT AT SEATS 9 AND 11 CHECK GOOD.SDR SWAA2020041441037Sign · unsecureEMERGENCY EXIT SIGN CIELING MID CABIN UNSECURED TO CIELING. / R&R EMER EXIT LIGHT ASSY PER AMM 33-51-01SDR AALA202004149008Battery · faultedAIRCRAFT IN BASE VISIT: EPSU (11WL) EXT L FAULT MESSAGE DURING EMERGENCY BATTERY TEST. REMOVED AND REPLACED BATTERY 11WL IAW AMM 33-51-00.SDR DALA2020041302245Battery Pack · dischargedSHIP 5649 DURING S/C FOUND EMERGENCY PATH LIGHTS INOP FROM ROW 23-26. COR RECTIVE ACTION: REPLACED BATT PACK M10567 IAW B757 AMM 33-51-07. TEST OK. (6973257)SDR AALA202004119005Battery · dischargedAIRCRAFT IN BASE VISIT: EPSU (13WL) AFT L FAULT MESSAGE DURING EMERGENCY BATTERY TEST. REMOVED AND REPLACED BATTERY 13WL PER AMM 33-51-00.SDR AALA202004119006Battery · dischargedAIRCRAFT IN BASE VISIT: EPSU (12WL) EXT R FAULT MESSAGE DURING EMERGENCY BATTERY TEST. REMOVED AND REPLACED BATTERY 12WL IAW AMM 33-51-00.SDR AALA202004119007Battery · dischargedAIRCRAFT IN BASE VISIT: EPSU (11WL) EXT L FAULT MESSAGE DURING EMERGENCY BATTERY TEST. REMOVED AND REPLACED BATTERY 11WL IAW AMM 33-51-00.SDR CALA2020041000824Battery Pack · failedB777-33-3-7019 R/H DR3 EMER PWR SUPPLY M33404 CAPACITY CHECK FAIL.REF NR LP 9130193 R/H DR3 EMER PWR SUPPLY M33404 BATTERY PACK REPLACED AND TEST CARRIED OUT WITH NORMAL RESULT AS PER AMM 33-51-06SDR CALA2020041000823Battery Pack · failedB777-33-3-7019: R/H DR4 EMER PWR SUPPLY M33409 CAPACITY CHECK FAIL.REF NR LP 9130188 R/H DR4 EMER PWR SUPPLY M33409 BATTERY PACK REPLACED AND TEST CARRIED OUT WITH NORMAL RESULT AS PER AMM 33-51-06SDR MASA2020041010153Light · inoperativeROW 6 CEILING LVL EMERG FLOOD LIGHT INOP- PLACED ON MELSDR SIMA2020051909005Nut Plate · brokenRH OVERWING EMERGENCY LIGHT HOUSING HAS 1EA NUTPLATE BROKEN-C/A-REMOVED AND REPLACED RH OVERWING EMERGENCY LIGHT HOUSING IAW EMB 145 AMM 33-50-10. OPS CK GOOD