SDR SWAA2015120346703Wire · damagedFORWARD RT EMER ESCAPE SLIDE LIGHT INOPERATIVE. REPAIRED WIRE IAW SWPM & WDM.SDR DALA2015120207319Connector · unsecureMAINTENANCE FOUND EMERGENCY LIGHTS INOPERATIVE BETWEEN ROWS 17 AND 23. A LOOSE CONNECTOR WAS SECURED AT ROW 16DEF AND LIGHTS CHECKED NORMAL.SDR YENA20151201613Wire Harness · damagedEMERGENCY LIGHT AT ROW 5 INOPERATIVE. EMERGENCY LIGHT HARNESS REPLACED IAW ESPM CH 22-33-00 AND IPC 33-51-09. OPS CKD SATISFACTORY IAW AMM CH 33-51-00.SDR DALA2015120107290Wire Harness · damagedDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY LIGHTING AT THE EMERGENCY EXIT ROW IN THE CABIN WAS INOPERATIVE. MAINTENANCE REPLACED THE WIRE HARNESS AND FUNCTIONALLY CHECKED THE SYSTEM.SDR SIMA20151130013Wire · brokenNUMBER 2 EMER LIGHT WIRE BROKE UNDER FLOOR. REPAIRED BROKEN WIRE ON NR 2 EMER LIGHT FLOOR WIRE W1928681-22 IAW SWPM 20-21-00 & SWPM 20-50-01. CRIMPER SN 6571, TURRET SN 7859, SEE NRTC BOW 207107 FOR INSTALLATION & OPERATIONS CHECK.SDR SIMA20151130012Wire · brokenNUMBER 1 & 7 EMER FLOOR PROXIMITY LIGHT STRIPS HAVE BROKEN WIRES. UPON FURTHER INVESTIGATION FOUND NR 1 ONLY EMER FLOOR PROXIMITY LIGHT STRIP HAS BROKEN WIRES. REPLACED NR 1 LIGHT STRIP SEE BOW 207107 FOR INSTALL & OPERATIONS.SDR SIMA20151130015Terminal · missingNUMBER 4 EMER LIGHT STRIP, PLANESIDE, TERMINAL END MISSING. REPAIRED SP9110 ON NR 4 EMER LIGHT STRIP, PLANESIDE, TERMINAL END IAW SWPM20-21-00-00.SDR VNAA2015113000021Connector · damagedCREW REPORTED PASSENGER PULLED EMERGENCY LIGHT FLOOR CONNECTOR BY LAVATORY. EMERGENCY LIGHTS INOPERATIVE. MAINTENANCE INSPECTED, REPAIRED AND REPLACED FLOOR TRACK EMERGENCY LIGHTS CONNECTOR AND PERFORMED CHECKS IAW AMM. ACFT RELEASED FOR SERVICE.SDR CALA2015120894869Wire · brokenEMERGENCY ESCAPE PATH FLOOR LIGHT AT SEAT 38 ABC HAS A BROKEN WIRE RUN. REPLACED CONNECTOR. OPERATIONS CHECK OF LIGHT FUNCTION, OPERATION CHECKED NORMAL.SDR AALA201511309003Wire · cutROW 11 LT EMER LIGHT WIRES ARE CUT. REPLACED EMER LIGHT WIRE ASSEMBLY.SDR ASOA2015112814142Wire · disconnectedTHE EMERGENCY EXIT SIGN FOR THE FORWARD CABIN SERVICE DOOR DS173, FAILED THE OPS TEST. FOUND WIRES TO EMERGENCY EXIT SIGN DS173 FOR THE FORWARD CABIN SERVICE DOOR TO BE DISCONNECTED. CONNECTED WIRE IAW AMM, OPS TEST OF EMERGENCY LIGHTS NOW GOOD. OPS TEST OF SDR DALA2015112807274Wire Harness · damagedF/A REPORTED SPARKS EMINATING FROM DOOR 2R EXIT SIGN DURING TAXI OUT RETURNED TO GATE. CHAFED WIRES. REPLACED HARNESS 7244VC CONNECTOR TO 44WL SIGN EXIT MARKING OF DOOR 2RT.SDR DALA2015112807223Connector · disconnectedSEAT 63 JK AND SEAT 65 JK EMERGENCY LIGHTS INOPERATIVE. FOUND UNDER SEAT CONNECTOR DISCONNECTED, RECONNECTED SAME, OPS CKS GOOD.SDR AALA201511279002Connector · looseEMERGENCY LIGHT INOPERATIVE AT SEAT ROW 16. FOUND CONNECTOR AT WALL LOOSE, RE-CONNECTED CONNECTOR & ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.SDR DALA2015113007264Wire Harness · damagedDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY LIGHTING AT SEAT 22D IN THE CABIN WAS INOPERATIVE. MAINTENANCE REPLACED THE WIRE HARNESS AND FUNCTIONALLY CHECKED THE SYSTEM.SDR SIMA20151125002Wire · brokenLIGHT ELEMENT OF PROXIMITY LIGHT STRIP, NR 6 HAS A BROKEN WIRE. R & R NR 6 FLOOR PROXIMITY LIGHT STRIP IAW AMM 33-50-12. SEE NRTC BOW 205943 FOR OPERATIONAL CHECK.SDR SIMA20151125004Connector · missingEMERGENCY LIGHT STRIP WIRE AT SEAT LOCATION 13 A IS MISSING SPLICE CONNECTOR. REPAIRED & INSTALLED SERVICEABLE SPLICE CONNECTOR ON EMER LIGHT STRIP WIRE AT SEAT LOCATION 13A IAW SWPM 20-21-00. SEE BOW 205943 FOR OPERATIONS CHECK.SDR SIMA20151125001Wire · chafedPROXIMITY LIGHT STRIP NR 1 WIRE AT THE FLOORBOARD IS MISSING AN ELEC CONNECTOR & THE SAME WIRE IS CHAFED WITH BARE WIRE SHOWING. R & R ELEC CONNECTOR, MALE & ACFT SIDE, AT SPLICE SP9019 FOR THE NR 1 PROXIMITY LIGHT STRIP IAW SWPM 20-21-00, 20-50-00 & 20-50-01SDR DALA2015113007281Connector · disconnectedEMERGENCY LIGHT AT SEAT 21AC RED AND WHITE ARE INOPERATIVE. MAINTENANCE REPLACED SIDEWALL DISCONNECT MATE CONNECTOR. SYSTEM OPERATION IS NORMAL.SDR DALA2015113007282Connector · brokenEMERGENCY LIGHTS AT SEAT 33A ARE INOPERATIVE DUE TO BROKEN WALL TO SEAT CONNECTOR. MAINTENANCE REPLACED CONNECTOR. SYSTEM OPERATION IS NORMAL.SDR IPXA2015112596114Connector · damagedINSPECTION TYPE: PS1, EMERGENCY EXIT LIGHT INOPERATIVE. TERMINATED PINS ON ENTRY DOOR CONNECTOR WIRES IAW WDM 33-51-05 AND SWPM 20-48-25. INSTALLED NEW SIGN IAW AMM 33-51-13-0401. OPS CHECKED NORMAL.SDR CALA2015112500957Wire · brokenSUPPORT TASK, EPL WIRING BROKEN AT ROW 24 ABC. SPLICED BROKEN EPL WIRE AT SEAT 24 ABC, SECTION 46, STATION 727B, LBL 32 INCHES WIRE BUNDLE NR BR9672-62 IAW WDM 33-51-22. PERFORMED OPERATIONS CHECK IAW AMM 33-51-00. OPERATIONS CHECKED GOOD.SDR VNAA2015112300013Connector · strippedCREW REPORTED EMERGENCY EXIT IN-FLOOR LIGHTING NOT WORKING FROM ROW 9 TO 13. MAINTENANCE INSPECTED, FOUND AFT CONNECTORS STRIPPED, R & R CONNECTORS AND PINS, AND PERFORMED CHECKS IAW AMM. ACFT RELEASED FOR SERVICE.SDR N6WA2015112202Wire Harness · disconnectedCEILING EMER LIGHT AT ROW 15 INOPERATIVE. CONNECTED HARNESS TO PLUG. OPERATIONS CHECKED GOOD AT THIS TIME IAW AMM 33-51-00.SDR REXA2015112101193Power Cable · defectiveFIRST LIGHT ON CABIN FLOOR TRACK IS NOT WORKING. REPLACED UNSERVICEABLE CABLE ASSEMBLY AT FWD CONNECTION WITH NEW CABLE ASSEMBLY IAW ESPM 20-17-10. OPERATIONS CHECKED GOOD.SDR RAIA201511210001Connector · dirtyEMERGENCY EXIT LIGHT ON PASSENGER DOOR IS INOPERATIVE. MAINTENANCE CLEANED CONNECTORS AND RELAMPED, OPS CHECKED GOOD.SDR FDEA201511203728Wire · damagedDURING ACFT B CHECK, FOUND ACFT NOSE GEAR TAXI LIGHTS ON DIM. CYCLED GND SERVICE & ACFT POWER CONTROL SWITCHES. DUE TO SMOKE IN THE COCKPIT, TROUBLE SHOT WIRING TO STATION 464 RT SIDE LOWER, FEED THROUGH FROM FWD AVIONICS COMPARTMENT TO RT PACK BAY. WIRING SDR SIMA20151120004Wire · damagedLEFT NR 2 EMER LIGHT STRIP WIRES PULLED OFF. R & R LT NR 2 FLOOR EMER LIGHT STRIP IAW AMM 33-50-12.SDR DALA2015111907087Connector · looseROW 23 D, E, F EMERGENCY LIGHT INOPERATIVE, SECURED LOOSE CONNECTION.SDR ASOA2015111814077Ground Wire · looseEMERGENCY SIGN OVER SERVICE DOOR WILL NOT ILLUMINATE. SCREWED LOOSE GROUND TO LIGHT IAW MM 33-51-00, OPS CHECK GOOD.SDR R61A201511180843Connector · looseCREW REPORTED THAT THE AFT CENTER EMERGENCY LIGHT WAS INOPERATIVE. MAINTENANCE DISCONNECTED AND RECONNECTED, CONNECTOR ON AFT CENTER EMERGENCY LIGHT IAW AMM AND OPS CHECKED GOOD.SDR RAIA201511170001Connector · unsecureRIGHT OVERWING EMERGENCY EXIT MARKER NR 24 INOPERATIVE. RESEATED GRAND CONNECTOR OF EMERGENCY LIGHT. OPS CHECK GOOD.SDR DALA2015112007115Wire · brokenROW 21 ACFT LT EMERGENCY LIGHT IN SEAT INOPERATIVE, REPAIRED BROKEN WIRE.SDR DALA2015112007114Wire · brokenROW 18 ACFT LEFT EMERGENCY LIGHT IN SEAT INOPERATIVE, REPAIRED BROKEN WIRE.SDR DALA2015111807018Wire Harness · damagedON SC FOUND EMERGENCY LIGHT SEAT HARNESS WIRE DAMAGED AT ROW 21 RT. REPAIRED HARNESS IAW SWPM 20-30-12, OK FOR SERVICE.SDR SIMA20151116003Wire · brokenAFT EXIT SIGN AT 252CRW HAS BROKEN WIRE, ACFT SIDE. INSTALLED CONNECTOR ON WIRE W192-8743-22, ACFT SIDE, AT SP9104 IAW SWPM 20-50-00.SDR R61A201511160844Connector · disconnectedWHILE IN HEAVY CHECK, MAINTENANCE REPORTED THAT THE PAX CABIN NR 3 CEILING EMERGENCY LIGHT WAS INOPERATIVE. MAINTENANCE PLUGGED IN PAX CABIN NR 3 CEILING EMERGENCY LIGHT IAW AMM AND OPS CHECKED GOOD.SDR 29GA2015111600001Connector · unsecureCIRCUIT BREAKER L8, EMERGENCY LIGHT, TRIPPED RESET AND TRIPPED AGAIN. FOUND LOOSE CONNECTION AT 29LN SWITCH, RESECURED, RESET CIRCUIT BREAKER L8 SYSTEM. OPERATIONAL CHECK NORMAL.SDR AALA201511159011Wire Harness · brokenSEAT 22C AISLE EMER LIGHT HAS A BROKEN WIRE. REPAIRED & SECURED WIRE ON EMER LIGHT IAW AMM 33-51-06. OPERATIONAL CHECKED GOOD.SDR AALA201511149002Wire · exposedC1 CHECK, EMER LIGHT HARNESS HAS EXPOSED WIRING. REPLACED EMER LIGHT WIRE HARNESS & ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK IAW AMM 33-51-00-710-801-A.SDR AALA201511149001Wire Harness · damagedC1 CHECK, EMER LIGHT HARNESS IN SEAT 4A DAMAGED. REPLACED EMER LIGHT HARNESS & ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK IAW AMM 33-51-00-710-801-A.SDR AALA20151114001Wire · brokenEMERGENCY LIGHTS AT SEAT ROW 11ABC & 12ABC INOPERATIVE. REPINNED WIRES IN PINS B & C OF CONNECTOR 7261VC7A IAW SWPM 20-48-21. ACCOMPLISHED EMERGENCY LIGHTS TEST AT 12ABC & 11ABC IAW AMM 33-51-00, OPERATIONS OK.SDR DALA2015111606989Wire · pulledSEAT 1CD EMERGENCY LIGHT WIRES PULLED OUT OF CONNECTOR. LOOSE WIRES STOWED. FWD TO MCO IAW MEL 33-51-03A. NO "M" PROCEDURES. ALL OTHER EMERGENCY ESCAPE PATH SEAT MOUNTED LIGHTS CK GOOD. PLACARD INSTALLED. R & R EMERGENCY ESCAPE PATH LIGHT IAW AMM 33-51. OSDR CALA2015111300923Light · inoperativeAFT EMER LIGHT ON SEAT 1AB NOT OPERATING. R & R FLOOR PROXIMITY LIGHT ASSEMBLY IAW AMM 33-51-11-960-802. OPERATIONS CHECKED GOOD.SDR SIMA20151112011Connector · missingEMERGENCY LIGHT STRIP CONNECTOR AT FLOOR PANEL 261BF MISSING, ACFT SIDE. INSTALLED MISSING CONNECTOR AT FLOOR PANEL 261BF, ACFT SIDE, SP9212 WIRE NR W192-8832-22 IAW SWPM 20-50-00.SDR SWAA2015111846128Connector · disconnectedFORWARD SERVICE DOOR OVERHEAD EXIT SIGN INOPERATIVE. RECONNECTED CONNECTOR IAW MM.SDR REXA2015111101098Connector · missingELECTRICAL CONNECTS FOR FLOOR TRACK EMER LIGHTS ARE MISSING IN MULTIPLE LOCATIONS. REPAIRED ELEC CONNECTORS FOR FLOOR TRACK EMER LIGHTS IAW ESPM 20-11-00. OPERATIONS TESTED GOOD IAW AMM 33-51-00-710-801.SDR REXA2015111101097Wire · brokenWIRE BROKEN TO EMER EXIT LIGHT IN BOTTOM OF WARDROBE. UPON INVESTIGATION, FOUND CONNECTOR BROKE OFF END OF WIRE. INSTALLED NEW SERVICEABLE CONNECTOR FOR EMER LIGHT IAW ESPM 20-17-31. OPERATIONS TEST OF THE EMER LIGHTS DUE. OPERATIONS TEST OF EMER LIGHTS GOSDR REXA2015111101096Wire · brokenEMERGENCY TRACK LIGHTING WIRING UNDER FLOORBOARD 251CLF BROKEN. R & R EMER TRACK LIGHT CONNECTOR PIN PL29LY IAW ESPM 20-17-10. OPERATIONS CHECK DUE. REF AMM 33-51-00-710-801. OPERATIONS TEST OF FLOOR TRACK EMER LIGHTING GOOD IAW AMM 33-51-00-710-801.SDR VNAA2015111100004Wire · disconnectedCREW REPORTED FLOOR EMERGENCY LIGHTS HAD A DISCONNECTED WIRE AND AFT HALF OF LIGHTS BEYOND ROW NINE INOPERATIVE. MAINTENANCE INSPECTED, SPLICED IN WIRE SPLICE CONNECTORS ON ROW 13 EMERGENCY FLOOR LIGHTS AND PERFORMED CHECKS IAW AMM. ACFT RELEASED FOR SERVICE
Back to JASC 3397