JASC 3397
Service difficulty reports · 22,664
Reports filed under 3397 · Light System Wiring, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3397' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3397' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SIMA20150908004Connector · disconnectedDURING PS 2, FOUND OVERHEAD EMER EXIT LIGHT ROW 11, HANGING DOWN & INOPERATIVE. RE-CONNECTED PLUG IN CEILING & SECURED LIGHT IAW SP. OPERATIONS CHECKED GOOD.SDR AALA20150908012Connector · brokenR3 DOOR, OVER AISLE EXIT SIGN BACK SHELL FOUND BROKEN. REPLACED R3 DOOR, OVER AISLE EXIT SIGN BACK SHELL. INSTALLATION TEST CARRIED OUT & RESULTS NORMAL IAW AMM 33-51-01.SDR DALA2015090805479Wire · unsecureEMERGENCY EXIT SIGN ABOVE TAIL CONE EXIT INOPERATIVE. SECURED CONNECTION ON AFT LIGHT ASSY.SDR ASOA20150906050RSWire Harness · arcedCREW REPORTED A BURNING ODOR FROM ROW 6 AND LIGHT PUFF OF SMOKE. MAINTENANCE R & R THE CABIN LIGHT ASSY AND HARNESS AT ROW 6. ACFT APPROVED FOR RETURN TO SERVICE.SDR SIMA20150905004Wire · brokenLEFT NR 2 EMER FLOOR STRIP LIGHT WIRES ARE BROKE OFF. R & R LT NR 2 FLOOR EMER LIGHT STRIP IAW AMM 33-50-12. SEE NRWC BOW 201288 FOR OPERATIONS CHECK.SDR SWAA2015091043702Connector · disconnectedR1 DOOR OVERHEAD EXIT SIGN INOPERATIVE. RE-CONNECTED CONNECTOR IAW WDM.SDR AALA201509059001Connector · dirtyA CHECK, L2 DOOR EMER LIGHT POWER SUPPLY 13WL, FAILED WHILE ACCOMPLISHING A SCHEDULED FUNCTIONAL CHECK. REMOVED THE L2 DOOR SLIDE, CLEANED CONNECTOR 5191VC-A, RE-INSTALLED THE SLIDE & ACCOMPLISHED A SATISFACTORY.SDR SIMA20150904006Connector · brokenNUMBER 1 CABIN FLOOR PROXIMITY LIGHT WIRE CONNECTOR BROKEN. R & R NR 1 CABIN FLOOR PROXIMITY LIGHT STRIP IAW AMM 33-50-12. SEE NRWC 826-ABI-02103 FOR OPERATIONAL CHECK.SDR SIMA20150904005Wire · brokenLEFT NR 5 PROXIMITY LIGHT HAS BROKEN WIRE AT BASE OF LIGHT. R & R LT NR 5 PROXIMITY LIGHT STRIP IAW AMM 33-50-12. OPERATIONAL CHECKED GOOD.SDR SIMA20150904004Connector · missingFLOOR PROXIMITY LIGHT, WIRE LT NR 1, MISSING CONNECTOR. REPAIRED FLOOR PROXIMITY LIGHT, WIRE LT NR 1 IAW SWPM 20-21-00. FOUND DURING ACFT OPEN UP.SDR UHLA201509020682Connector · unsecureTHE FWD EMERGENCY EXIT LOCATOR SIGN IS INOPERATIVE. SECURED CONNECTOR AT FWD EMERGENCY EXIT LOCATOR SIGN IAW AMM 33-50-19.SDR CALA2015090300727Connector · unsecureEMERGENCY LIGHT AT DOOR 2L INOPERATIVE DURING TEST. DOOR 2L EMER LIGHT ELEC PLUG SECURED & TESTED NORMAL IAW AMM 33-51-06.SDR AALA20150902002Connector · looseROW 17 EPL LIGHT INOPERATIVE, FOUND CONNECTOR LOOSE UNDER SEAT. CONNECTED & SECURED CONNECTOR. OPERATIONS CHECKED GOOD IAW AMM 33-51-00. REMOVED PLACARD & CLEARED MIC SHEET.SDR SIMA20150901002Wire · brokenAFT ROW EMER LIGHT FLOOR STRIP HAS BROKEN WIRE. R & R AFT ROW EMER LIGHT FLOOR STRIP IAW MM 33-50-12. OPERATIONS CHECKED GOOD.SDR SWAA2015090943526Connector · defectiveFORWARD RT SERVICE DOOR EMER LIGHT ON HEADER PANEL INOPERATIVE. R & R FWD CONNECTOR IAW AMM.SDR SWAA2015090343490Connector · looseFORWARD SERVICE DOOR EMER LIGHT INOPERATIVE. FOUND CONNECTOR LOOSE, RE-SEATED CONNECTOR IAW WDM & AMM.SDR DALA2015090105404Nut · looseFOUND SEAT MOUNTED EMERGENCY LIGHTS BETWEEN SEAT 31ABC AND 40ABC WOULD NOT TURN ON. FOUND "GD4214-DC" BOTH GROUND TERMINALS NUT LOOSE. THEN TIGHTENED THE NUT, GROUND TERMINAL. PERFORMED ALL EMERGENCY LIGHTS CHECKED OK IAW AMM 33-51. ACFT OK FOR SERVICE.SDR CALA2015090300726Connector · unsecureEMERGENCY EXIT LIGHT ABOVE DOOR 2L INOPERATIVE. SECURED PLUG ON LIGHT ASSEMBLY. SYS CHECKED GOOD IAW 33-51-00-0 0C-320A-A.SDR DALA2015090105389Feeder Cable · disconnectedEMERGENCY LIGHT INOPERATIVE AT SEAT ROW 8 ABC. CONNECTED FEEDER WIRES AT SEAT DISCONNECT. OPS NORMAL.SDR A6WA201543015Connector · unsecureFLIGHT 3862, EMER LIGHTING ON THE FLOOR IS INOPERATIVE FROM ROW 8 TO THE REAR OF ACFT. SECURED CONNECTOR ON ROW 8 LIGHT STRIP. OPERATIONS CHECKED GOOD.SDR VNAA2015083000038Connector · disconnectedCREW REPORTED EMERGENCY FLOOR LIGHTS INOPERATIVE FROM ROW 9 AND AFT. MAINTENANCE INSPECTED, FOUND RT AFT EMERGENCY LIGHT CONNECTOR DISCONNECTED, RECONNECTED CONNECTOR AND PERFORMED CHECKS IAW AMM. ACFT RELEASED FOR SERVICE.SDR YENA20150830403Wire Harness · faultedDURING HEAVY MAINTENANCE, FOUND EMERGENCY LIGHTS FAILED CHECK IAW 33-51-38. PERFORMED TROUBLESHOOTING IAW TSM 33-51-00. R & R FAULTY SEAT TO WALL HARNESS AT 25R IAW AMM 33-51-18. EMERGENCY LIGHT SYSTEM OPS CHECKED GOOD IAW AMM 33-51-00.SDR DALA2015083105378Connector · unsecureEMERGENCY LIGHTS INOPERATIVE ON SEATS AT ROWS 17 & 18 ABC. SECURED CONNECTORS ON ROW 17 & 18.SDR AALA20150830010Wire · disconnectedSEAT 8 DEF EMER LIGHT WIRES NEED TO BE REATTACHED. CONNECTED EPL AT SEAT 8 DEF IAW CHAP 20-72-07. OPERATIONALLY CHECKED GOOD IAW WC J1877CC-0004.SDR AALA20150830009Wire · looseSEAT 13 DEF HAS LOOSE WIRE ON CONNECTOR FOR EMER LIGHTS. CONNECTED LOOSE EMER LIGHT WIRES IAW CHP.20 20-72-07. OPERATIONS CHECKED IAW WC 1877CC-004.SDR CALA2015083194260Connector · not seatedDOOR 4L & DOOR 4R EMER EXIT SIGNS REMAIN ILLUMINATED AFTER SELECTING EMER LIGHT SWITCH TO THE OFF POSITION. SEATED CONNECTOR TO EMER LIGHT POWER SUPPLY FOR DOOR 4L & 4R, RESET EMER LIGHT CB DOOR 4L & 4R ON P 11 PANEL. ACCOMPLISHED SUCCESSFUL TEST OF THE EMERSDR SIMA20150829002Connector · damagedCONNECTOR FOR EMER LIGHT STRIP ATTACHED TO FLOOR PANEL261 BF IS PULLED OFF WIRE. REPAIRED CONNECTOR FOR EMER LIGHT STRIP ATTACHED TO FLOOR PANEL261 BF IAW SWPM 20-21-00. SEE NRWC 854-ABI-01856 FOR OPERATIONS CHECK. FOUND DURING CLOSE UP.SDR ASOA2015082813732Wire · brokenFOUND BROKEN WIRE ON EXIT LIGHT, JUST FORWARD OF SERVICE DOOR. REMOVED AND REPLACED THE SIGN IAW AMM 33-51-10-000-801, AND AMM 33-51-10-400-801. PERFORMED OPS TEST IAW AMM 33-51-00-710-801.SDR ASOA2015082813675Connector · disconnectedEMERGENCY EXIT LIGHTS INOPERATIVE ON F/A BS AND GALLEY 1. TROUBLESHOT EMERGENCY EXIT LIGHTS ON F/A BS AND GALLEY FOUND CONNECTORS FOR FLOOR EXIT SIGN AT SERVICE DOOR AND FLOOR LEVEL FLOOD LIGHT SWAPPED AND FLOOR EXIT SIGN WIRE AT SIGN, DAMAGED AT SIGN. PUT CSDR CALA2015082894248Connector · unsecureSEAT MOUNTED EMER EXIT LIGHT INOPERATIVE AT SEAT ROW 36 RT. SECURED CONNECTOR, OPERATIONS CHECKED NORMAL.SDR DALA2015090305407Module · brokenSEAT 26D EMERGENCY LIGHT MODULE BROKEN. REPLACED THE MODULE CMM 25-22-57. OPS CHECKED GOOD.SDR SIMA20150827005Wire · brokenEMERGENCY LIGHT STRIP HARNESS, BROKEN WIRE UNDER FLOOR PANEL 231GF. REPAIRED LIGHT STRIP FLOOR PROXIMITY LIGHT WIRES UNDER PANEL 231GF IAW SWPM 20-21-00. FOUND DURING OPEN UP.SDR SIMA20150827004Wire · brokenFOUND NR 2 FLOOR PROXIMITY LIGHT AT 241DF WIRES BROKEN. REPAIRED NR 2 FLOOR PROXIMITY LIGHT WIRES IAW SWPM 20-21-00. FOUND DURING OPEN UP.SDR DALA2015083105344Connector · unsecureSEAT 19 DEF EMERGENCY LIGHT INOPERATIVE. FOUND CONNECTOR LOOSE, SECURED THE CONNECTOR, OPS CHECKED NORMAL.SDR SIMA20150826004Pin · defectiveLEFT OVERWING EMER EXIT, AFT EXIT LIGHT INOPERATIVE. R & R CONNECTOR PIN ON SPLICE SP9126 IAW AMM 33-50-00.SDR AALA20150825020Wire Harness · faultySEAT MOUNTED EMER LIGHT AT 13DEF INOPERATIVE. INSTALLED SERVICEABLE WIRE HARNESS AT ROW 13DEF IAW WDM 33-51-11. SYS CHECKED NORMAL.SDR SIMA20150824006Wire · brokenLEFT NR 1 FLOOR PROXIMITY LIGHT STRIP HAS BROKEN WIRE. REPAIRED BROKEN WIRE ON LT NR 1 FLOOR PROXIMITY LIGHT STRIP IAW SWPM 20-21-00.SDR MASA2015082412339Wire · damagedLOWER EMERGENCY EXIT SIGN 14A INOPERATIVE. REPAIRED WIRE AT CONNECTOR J552.SDR MASA2015082412341Circuit Board · malfunctionedEMERGENCY LIGHTS STAY ON IN THE ARMED POSITION. R & R PCB5 IN JB11.SDR YENA20150823379Wire Harness · damagedDURING MAINTENANCE, FOUND EMERGENCY LIGHT 15ABC INOPERATIVE. R & R INSEAT CABLE HARNESS AT 15LT IAW ESPM 20-33-11. OPS NORMAL.SDR DALA2015082405206Connector · damagedSEAT 23 D, E, F EMERGENCY LIGHT INOPERATIVE. R & R LIGHT PIGTAIL ASSY. OPS CHECKED GOOD.SDR ASOA20150817067Wire Harness · burnedTHE CREW REPORTED A STRONG ELECTRICAL BURNING ODOR AROUND ROW 3 BY MULTIPLE CREW MEMBERS, AND THE ODOR WENT AWAY WHEN THE CABIN LIGHTS WERE TURNED OFF. THE ACFT LANDED WITHOUT INCIDENT WHERE MAINTENANCE R & R THE LIGHT HARNESS ASSY ABOVE SEAT 4A, OPERATIONALLSDR CALA2015082494240Connector · looseSEAT 8K MONITOR STAND EMER EXIT LIGHT INOPERATIVE. SECURED EMER EXIT LIGHT CONNECTOR. OPERATIONS CHECKED OK.SDR DALA2015082105120Wire · failedEMERGENCY LIGHT INOPERATIVE AT SEAT 30R. FOUND WIRE SECTION BAD AT SEAT 30R. REPLACED THE WIRED IAW SWPM. CHECKED GOOD. OK FOR SERVICE.SDR DALA2015082105118Wire · broken43D EMERGENCY LIGHT INOPERATIVE. FOUND BROKEN WIRE FROM OTBD HARNESS CONNECTOR. REPAIRED IAW SWPM 20-30-12, OPS CHECKED OK.SDR AALA201508209004Cable · looseROW 3A EMER LIGHT INOPERATIVE. R & R LAMPS BULB AT SEAT 3A, FOUND CABLE LOOSE, CONNECTED TESTED OK.SDR CALA2015082094231Cable · damagedDOOR 4 LT GALLEY EMER LIGHT CABLE DAMAGED. REPLACED DOOR 4 LT GALLEY EMER FLASHLIGHT PN8054-1.SDR DALA2015082005067Connector · disconnectedPASSENGER SEAT 16D ISLE EMERGENCY LIGHT INOPERATIVE. UPON INVESTIGATION FOUND CONNECTOR UNPLUGGED. RESECURED AND FUNCTIONAL CHECK WAS NORMAL.SDR IPXA2015081892491Connector · unknownINSPECTION TYPE: IN, EMERGENCY EXIT LIGHTS REMAIN ON CONTINUALLY. SWITCH HAS NO EFFECT. REMOVED & RECONNECTED CONNECTOR FROM 436 VU IAW WDM 33-51-03. OPS CHECK GOOD.SDR DALA2015081805016Wire · pulledDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY LIGHTING AT SEAT 24DE IN THE CABIN WAS INOPERATIVE. MAINTENANCE FOUND WIRES PULLED OUT OF THE CONNECTOR. THE CONNECTOR WAS REPLACED AND THE SYSTEM RETURNED TO NORMAL OPERATION.
Back to JASC 3397