JASC 3397
Service difficulty reports · 22,664
Reports filed under 3397 · Light System Wiring, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3397' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3397' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA20141006001Connector · looseEMERGENCY EXIT PATHWAY LIGHT AT SEAT 10D INOPERATIVE. FOUND LOOSE CONNECTOR AT SIDEWALL. RECONNECTED CONNECTOR FOR SEAT MOUNTED EMER LIGHT AT 10D. OPERATIONS CHECKED NORMAL.SDR AALA20141004003Connector · unsecureSEAT 5B FWD SEAT MOUNTED EMER LIGHT INOPERATIVE. SECURED CONNECTOR AT LIGHT ASSEMBLY. OPERATIONS CHECKED NORMAL.SDR XV6A2014100300007Wire · brokenLEFT AND RIGHT OVERWING ESCAPE SQUIBS TEST WILL NOT TEST SUCCESSFULLY. LEFT AISLE 3AC EMERGENCY LIGHT INOPERATIVE L9709 BROKEN WIRING. R & R LT OVERWING EMERGENCY ILGHT BATTERY & CHARGER. R & R RT OVERWING EMER BATTERY & CHARGER. REPLACED CONNECTOR FOR LSDR AALA20141004001Connector · unsecureCONNECTION TO EMER FLOOD LIGHT AFT LAVATORY WALL INOPERATIVE. SECURED CONNECTION. OPERATIONS CHECKED NORMAL.SDR UHLA2014100300669Connector · disconnectedFWD PAX EXIT LOCATOR SIGNS INOPERATIVE. FOUND CONNECTOR DISCONNECTED. MATED FEMALE PLUG WITH MALE PLUG, PEFORMED OPS CHECK OF LOCATOR SIGNS, OPS CHECKED GOOD IAW JC S33-50-01-720-801A.SDR SIMA20141003002Connector · looseLEFT OVERWING EMER LIGHT IS INOPERATIVE. FOUND CONNECTOR LOOSE. TIGHTEN CONNECTOR AS REQUIRED. OPERATIONS CHECKED GOOD.SDR ASOA2014103011575Connector · missingFWD WARDROBE UNIT EMERGENCY EXIT FLOOR LIGHT HAS TWO QUICK DISCONNECT CONNECTORS MISSING. INSTALLED NEW QUICK DISCONNECTORS ON FWD WARDROBE UNIT ON EMERGENCY EXIT FLOOR LIGHT IAW ESPM 20-16-00. COMPLIED WITH OPS TEST OF EMERGENCY LIGHT ON FWD WARDROBE IAW AMSDR SIMA20141002002Connector · not seatedEMERGENCY LIGHT LOWER INVERTER BEHIND GALLEY CEILING PANEL CONNECTOR NOT LOCKED INTO RECEPTACLE. LOCKED EMER LIGHT LOWER INVERTER BEHIND GALLEY CEILING PANEL CONNECTOR INTO RECEPTACLE IAW 145 AMM 33-50-11. OPERATIONS CHECKED GOOD.SDR REXA2014100101009Pin · not seatedWARDROBE HAS ONE EACH EMER LIGHT INOPERATIVE & CTR AISLE FWD EMER LIGHT INOPERATIVE. FOUND RECESSED PIN AT CHARGER ASSEMBLY NR 2 RESEATED PIN IAW ESPM 20-17-10. OPERATIONS CHECKED GOOD IAW AMM 33-51-00-710-801.SDR CALA2014100101293Connector · looseEMERGENCY EXIT LIGHT AT SEAT 39C INOPERATIVE. FOUND CONNECTOR KICKED LOOSE AT SEAT TRACK & SEAT LEG. OPERATIONS CHECKED GOOD.SDR DALA2014100105358Ground Wire · brokenDURING CHECK, MAINTENANCE FOUND THE EMERGENCY LIGHT FROM ROWS 13 TO 23 TO BE INOPERATIVE. MAINTENANCE FOUND A WIRE TO GROUND BROKEN AT THE PIN. THE WIRE WAS REPINNED AND THE LIGHTS WERE OPERATIONAL.SDR PNSA2014093002Connector · faultyOVERHEAD EMER LIGHT 9A DOESN'T WORK 41 LN RESET CONNECTOR. OPERATIONS CHECKED GOOD.SDR AALA20140930001Connector · unsecureEMERGENCY EXIT LOCATOR SIGN ARROW AT FWD WALL OF RT NR 4 AFT LAVATORY INOPERATIVE. SECURED CONNECTOR. OPERATIONS CHECKED NORMAL.SDR VNAA2014092900014Wire · brokenCREW REPORTED EMERGENCY LIGHT INOPERATIVE AFT OF EXIT ROW. MAINTENANCE INSPECTED EMERGENCY FLOOR TRACK LIGHT AND FOUND BROKEN WIRE AT LAV CONNECTION. MAINTENANCE R & R AFT SECTION OF EMERGENCY FLOOR LIGHT AND PERFORMED CHECKS IAW AMM. ACFT RELEASED FOR SERVISDR DALA2014093005360Connector · damagedMAINTENANCE FOUND THE EMERGENCY LIGHT AT 35E WAS INOPERATIVE. MAINTENANCE REPLACED THE PIGTAIL AT 35D AND THE OPS CHECK WAS GOOD.SDR SIMA20140928004Wire · brokenLEFT EMER LIGHT NR 4 HAS A BROKEN WIRE. R & R LT EMER LIGHT NR 4 IAW AMM 33-50-12 IAW BOW 166820 FOR OPERATIONS CHECK.SDR DALA2014093005325Wire Harness · intermittentDURING CHECK, MAINTENANCE FOUND THAT SEAT 30D EMERGENCY PATH LIGHT WAS INTERMITTENT. MAINTENANCE REPLACED THE LIGHT HARNESS AND THE OPS CHECK WAS GOOD.SDR DALA2014093005324Terminal · brokenDURING CHECK, MAINTENANCE FOUND THE EMERGENCY LIGHTS WERE INOPERATIVE ON THE CAT WALK. MAINTENANCE FOUND A BROKEN TERMINAL END AND THEY REPLACED THE TERMINAL END AND THE OPS CHECK WAS GOOD.SDR DALA2014092905311Fuse · brokenDURING INSPECTION, FOUND EMERGENCY LIGHTS INOPERATIVE FROM ROW S10-16 FED. MAINTENANCE FOUND F2 FUSE BROKEN. REPLACED EMERGENCY PACK CHARGER IAW AMM 33-51. OPS CHECKED NORMAL.SDR CHQA20140927281Wire Harness · damagedTHE CREW REPORTED THAT THERE WAS AN ELEC SMELL IN THE FWD CABIN. REPLACED THE CEILING LIGHT HARNESS ASSEMBLY AT ROW 8. OPERATIONAL CHECKS WERE GOOD WITH NO FURTHER DEFECTS NOTED.SDR AALA20140927001Wire · cutFOUND CONNECTOR WIRES CUT AT RT CEILING PANEL NR 3. RETERMED W1222-022-20 & W1222-037-20 EMER LIGHT CABLES AT CEILING PANEL AREA RT NR 3 IAW WDM 33-51-12.SDR SIMA20140927003Connector · unsecureEMERGENCY LIGHTING STRIPS FROM 3A TO 7A INOPERATIVE. SECURED CONNECTOR FOR EMER LIGHTS IAW AMM 33-50-08.SDR AALA20140926003Pin · looseSEAT MOUNTED EMER LIGHT AT 23G INOPERATIVE. FOUND PIN THAT WAS LOOSE IN CONNECTOR, NOT SEATED. SEATED PIN IN CONNECTOR & SECURED. OPERATIONS CHECKED NORMAL.SDR REXA2014092600998Connector · not seatedEMERGENCY LIGHTING ON THE FLOOR ROWS 1 -5 INOPERATIVE. RESEATING FLOOR TRACK CONNECTOR OF EMER LIGHTS, ALL LIGHTS WORK. EMER LIGHTING SYS OPERATIONS CHECKED GOOD IAW AMM 33-51-01. ACFT IS OK FOR SERVICE.SDR REXA2014092600991Ground Wire · damagedFOUND RT OVERWING DOOR EXTERNAL EMER LIGHT ASSEMBLY GND WIRE DAMAGED. REPAIRED GND WIRE ON EXTERNAL EMER LIGHT ASSEMBLY. ALL CHECKED GOOD AT TIME IAW 20-16-11.SDR QXEA2014092500808Connector · disconnectedVERTICAL EMERGENCY EXIT LIGHT INOPERATIVE . FOUND CONNECTOR DISCONNECTED. SECURED THE CONNECTOR AND PERFORMED AN OPS CHECK IAW TASK CAR 335000202-60045. CHECKED GOOD.SDR VJ3S2014FA0000563Circuit Breaker · failedPILOT REPORTED THAT THE STROBE LIGHT WAS INOPERATIVE. TROUBLESHOT THE SYSTEM AND DISCOVERED THE STROBE LIGHT FAILED. REPLACED THE CIRCUIT BREAKER.SDR DALA2014092505220Wire · damagedDURING NON-ROUTINE CHECK, FOUND EMERGENCY LIGHT INOPERATIVE AT SEAT 23. MAINTENANCE REPAIRED WIRE TO LIGHT ASSY AND OPS CHECKED NORMAL.SDR DALA2014092505219Wire · miswiredL4 DOOR EMERGENCY EXIT SIGN INOPERATIVE. FOUND WIRES CROSSED, PROPERLY CONNECTED WIRES.SDR SIMA20140923008Connector · brokenFLOOR PROXIMITY LIGHT STRIP CONNECTOR NR 5 BROKEN INSIDE CABIN. REPAIRED FLOOR PROXIMITY LIGHT STRIP CONNECTOR NR 5 IAW SWPM 20-21-00 STEP 5. SEE NRTC E409709 FOR OPERATIONS CHECK.SDR DALA2014092405346Wire · damagedRT AFT RED EMERGENCY EXIT LIGHT IS INOPERATIVE. MAINTENACE REPAIRED SPLICE AT FLOOR. SYSTEM CHECKS NORMAL.SDR VNAA2014092300009Wire · looseCREW REPORTED LIGHTS OUT FOR EMERGENCY EXIT SIGN OVER SEAT 4D. MAINTENANCE INSPECTED, SECURED LOOSE WIRE ON RT EMERGENCY EXIT SIGN ON CLASS DIVIDER AND PERFORMED CHECKS IAW MM. ACFT RELEASED FOR SERVICE.SDR DALA2014092305181Fuse · failedDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY LIGHTING AT SEAT 30 IN THE CABIN WAS INOPERATIVE. MAINTENANCE REPLACED THE FAILED FUSE AT THE POWER SUPPLY AND THE LIGHTS RETURNED TO AN OPERATIONAL CONDITION.SDR CALA2014092402282Connector · unsecureUPPER DECK AFT FLOOR PROXIMITY EMERGENCY EXIT LIGHT INOPERATIVE. REPLACED FWD EMERGENCY EXIT SIDE LIGHT, SECURED AFT & STAIRS EMERGENCY EXIT LIGHT CONNECTOR. OPERATIONS CHECKED OK.SDR DALA2014092405206Connector · damagedEMERGENCY LIGHT AT ROW 10 INOPERATIVE. FOUND PIN PUSHED OUT AT CONNECTOR. RESEATED PIN, OPS CHECKED NORMAL.SDR A6WA201441991Wire · pulledEMERGENCY LIGHTS BETWEEN ROWS 9 - 12 INOPERATIVE. INSPECTED FLOOR TRACK LIGHTING & FOUND WIRING PULLED FROM CONNECTOR AT ROW 13. APPLIED TAPE TO BARE WIRE & APPLIED MEL. CONNECTOR TO BE REPLACED AT MX BASE.SDR DALA2014092205209Wire · brokenMAINTENANCE FOUND THE EMERGENCY AISLE LIGHTS ON SEAT 25ED WERE INOPERATIVE. MAINTENANCE FOUND A BROKEN WIRE AT THE CONNECTOR. THE CONNECTOR WAS REPLACED AND THE OPS CHECK WAS GOOD.SDR WX0A2014092272166Wire · looseR1 EMER EXIT LIGHT INOPERATIVE. FOUND LOOSE WIRE CONNECTION AT R1 EMER EXIT LIGHT ASSEMBLY. TIGHTENED WIRE CONNECTION AT EMER LIGHT IAW 20-27-00. OPERATIONS CHECKED GOOD AT THIS TIME.SDR REXA2014092100970Cable · defectiveEMER FLOOR LIGHTING INOPERATIVE BETWEEN ROWS 2 & 6. R & R EMER FLOOR LIGHT CABLE FOR FWD SECTION IAW AMM 33-51-01. OPERATIONS CHECKED GOOD, ACFT OK FOR SERVICE.SDR CALA2014092292257Connector · looseSEAT 26J MOUNTED EMER ESCAPE PATH LIGHT FAILED TEST IAW A CHECK JOB CARD 6-2006-A ITHE 2C PG 5. SECURED LOOSE CONNECTOR. OPERATIONS TESTED OK IAW MM 33-51-10.SDR CALA2014092292256Connector · looseSEAT 30B MOUNTED EMER ESCAPE PATH LIGHT FAILED TEST IAW A CHECK JOB CARD 6-2006-A ITEM 2C PG 5. SECURED LOOSE CONNECTOR. OPERATIONS TESTED OK IAW MM 33-51-10.SDR SIMA20140920002Connector · looseRIGHT OVERWING EMER LIGHT IS INOPERATIVE. REMOVED PANEL 194 AR FOUND CONNECTOR LOOSE. CLEANED & RECONNECTED CONNECTION IAW AMM 33-50-10. OPERATIONS CHECKED GOOD.SDR AALA20140920008Ground Wire · brokenLEFT NR 1 DOOR THRESHOLD EMER LIGHT GND WIRE BROKEN OFF. REPAIRED BROKEN GND WIRE AT LT NR 1 THRESHOLD LIGHT ASSEMBLY. OPERATIONS CHECKED NORMAL.SDR ASOA20140919104Wire Harness · burnedCABIN CREW REPORTED A BURNING ODOR FROM OVERHEAD LIGHTING AROUND ROW 10. CONTRACT MX FOUND THE FOWARD CEILING LIGHT FIXTURE BURNED OUT. MAINTENANCE R & R NR 10 FWD CEILING LIGHT FIXTURE HARNESS WITH OPS CHECK GOOD. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR JJBA20140919008Connector · disconnectedUPPER EMER EXIT LIGHT AT ROW 18 NOT ILLUMINATING. RECONNECTED CONNECTOR.SDR A6WA201441984Cable · damagedEMERGENCY FLOOR TRACK LIGHTING INOPERATIVE ROWS 9 - 12. R & R EMER FLOOR TRACK LIGHTING CABLE STRIP ASSEMBLY FROM ROW 9 - 12. OPERATIONS CHECKED GOOD AT THIS TIME. IAW SUPP 13-022 & AMM 33-51-01.SDR USAA2014091900001Connector · defectiveSEAT MOUNTED EMER LIGHT INOPERATIVE AT 6B. REPINED CONNECTOR AT SIDE WALL FOR SEAT 6AB EMER ESCAPE PATH LIGHT. OPERATIONAL CHECK IS GOOD.SDR DALA2014091805103Connector · disconnectedAISLE EMERGENCY LIGHT INOPERATIVE AT 36D. FOUND CONNECTOR DISCONNECTED, RECONNECTED.SDR SIMA20140917007Wire · brokenNUMBER 3 FLOOR PROXIMITY STRIP LIGHT DOES NOT ILLUMINATE HAS BROKEN WIRE. R & R NR 3 FLOOR PROXIMITY STRIP LIGHT IAW AMM 33-50-12 OPERATIONS CHECKED GOOD.SDR DALA2014091805116Terminal · brokenDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY LIGHTING FOR THE MIDDLE OF THE CATWALK IN THE TAIL COMPARTMENT WAS INOPERATIVE. MAINTENANCE FOUND A BROKEN TERMINAL END, RETERMINATED IT, AND FUNCTIONALLY CHECKED THE SYSTEM.
Back to JASC 3397