JASC 3397
Service difficulty reports · 22,664
Reports filed under 3397 · Light System Wiring, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3397' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3397' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA14025060669Contact · damagedEXTERIOR EMERGENCY LIGHT INOPERATIVE. R & R LAMP CONTACT. OPS NORMAL.SDR DALA14025050687Connector · damagedEMERGENCY LIGHT AT ROW 42, SEAT, INOPERATIVE. REPLACED WIRE CONNECTOR, CHECKED OK.SDR DALA14025533306Connector · disconnectedEMERGENCY LIGHT INOPERAIVE AT SEATS 30-32 AB. RECONNECTED CONNECTOR AT SEAT 32.SDR AALA20140422001Wire · pulledWIRES PULLED OUT OF CONNECTORS FOR FWD CATWALK EMERGENCY LIGHT. TERMINATED WIRES FOR FWD CATWALK EMERGENCY LIGHT, OPERATIONS CHECKED NORMAL.SDR SWAA2014042327323Wire · disconnectedAFT ENTRY DOOR EMERGENCY EXIT SIGN WIRE DISCONNECTED. CONNECTED WIRE IAW WDM.SDR DALA14024783126Wire · brokenDURING SERVICE CHECK, FOUND EMERGENCY LIGHTS AT ROW 6 ABC INOPERATIVE. SPLICED WIRE IAW ESPM 20, OPS CHECKED GOOD, OK FOR SERVICE.SDR SIMA20140420006Wire · brokenNR 8 EMERGENCY PROXIMITY LIGHT STRIP WIRES BROKEN. R & R NR 8 EMERGENCY PROXIMITY LIGHT STRIP AS REQUIRED.SDR SIMA20140420007Wire · damagedNR 4 & NR 6 EMERGENCY PROXIMITY LIGHT STRIP HAS DAMAGED WIRES. R & R NR 4 & NR 6 EMERGENCY PROXIMITY LIGHT STRIP AS REQUIRED.SDR VNAA2014041900015Connector · damagedCREW REPORTED EMERGENCY LIGHTS ALONG ROW 1D TORN OFF AND INOPERATIVE. MAINTENANCE INSPECTED AND REPLACED CONNECTORS P24LY AND J25LY THAT WERE FOUND TO BE RIPPED FROM AIRFRAME WIRING AND PERFORMED CHECKS. MAINTENANCE ALSO FOUND EMERGENCY FLOOR LIGHTING STRIP SDR DALA14024820924Connector · disconnectedDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY LIGHT AT SEAT 12D WAS INOPERATIVE. MAINTENANCE FOUND A CONNECTOR IN THE WIRE HARNESS DISCONNECTED, CONNECTED AND FUNCTIONALLY CHECKED THE SYSTEM.SDR DALA14024430691Wire · disconnectedROW 37 SEAT EMERGENCY LIGHT INOPERATIVE. WIRE DISCONNECTED AT SOCKET HARNESS. R & R SOCKET HARNESS AT SEAT 37DEF.SDR CALA2014042200485Terminal · looseLEFT ROW 25 AISLE EMERGENCY LIGHT INOPERATIVE. TROUBLESHOOTING FOUND LOOSE TERMINAL END AT LIGHT ASSEMBLY, SECURED TERMINAL IAW AMM 33-51-05 & TESTED NORMAL IAW AMM 33-51-00.SDR ASOA2014042910416Wire · brokenEMERGENCY LIGHT IS INOPERATIVE, AFT INBD. FOUND TWO WIRES ON LAMP ASSY BROKEN. REPAIRED WIRES IAW 0ESPM 20-16-00. PERFORMED OPS TEST OF EMERGENCY LIGHTING IAW 0AMM 33-51-00-710-801 OPS TEST GOOD AT THIS TIME.SDR CALA2014042190878Lead · defectiveFLOOR EEL LIGHT STRIP FROM SEATS 8 - 14 INOPERATIVE. STRIP FLICKERS VERY WEAKLY. REPLACED POWER LEAD IAW AMM 33-51-07, OPERATIONS CHECKED OK.SDR USAA2014042100009Connector · disconnectedRIGHT OVERWING EMERGENCY EXIT SIGN INOPERATIVE. ATTACHED CONNECTOR TO RT OVERWING EMERGENCY EXIT SIGN.SDR DALA14024393234Connector · looseDURING NON-ROUTINE CHECK, FOUND EMERGENCY EXIT SIGN AT L1 DOOR LWR LT CORNER INOPERATIVE. MAINTENANCE FOUND LOOSE CONNECTION AT SIGN; TIGHTENED CONNECTION AND OPS CHECK WAS NORMAL.SDR DALA14024773132Wire · brokenFWD IN-SEAT EMERGENCY LIGHT AT ROW 2 HAS A BROKEN WIRE AT CONNECTOR. CRIMPED PIN ONTO WIRE AT CONNECTOR IAW ESPM 20, OPS TESTED GOOD. OK FOR SERVICE.SDR REXA2014041700380Connector · faultyEMERGENCY FLOOR LIGHTS INOPERATIVE FROM ROWS 2 - 5. R & R CONNECTOR AT EMERGENCY FLOOR LIGHTS AT ROW 5 IAW CRJ AMM 33-51-01. EMERGENCY FLOOR LIGHTS RAMP TESTED GOOD.SDR CALA2014041700472Connector · disconnectedSPT SEAT 9ABC EMERGENCY PATH LIGHT IS INOPERATIVE. PLUGGED UP CONNECTOR FOR SEAT 9ABC EPL LIGHT IAW AMM 25- 22-00 STEP 17, OPERATIONS CHECKED GOOD.SDR DALA14023786810Connector · brokenFIRST CLASS ROW 4 RT SEAT MOUNTED EMERGENCY LIGHT SIDE CONNECTOR BROKEN. R & R EMERGENCY LIGHT CONNECTOR AT ROW 4 RT IAW SWPM 20-63-00 PERFORMED SATISFACTORY OPS TEST OF EMERGENCY LIGHTS IAW AMM 31-51-00, NO DEFECTS NOTED AT THIS TIME.SDR SWAA2014041727195Wire · looseAFT OVERHEAD EMERGENCY EXIT LIGHT LOOSE. SECURED LIGHT WIRING IAW SWPM.SDR USAA2014041700007Wire · disconnectedROW 1 LT EMERGENCY CEILING LIGHT INOPERATIVE. CONNECTED WIRES TO ROW 1 EMERGENCY CEILING LIGHT.SDR SIMA20140415017Connector · brokenFLOOR PROXIMITY STRIP LIGHTS WIRE CONNECTOR BROKEN, PAX CTR FLOOR PANEL JUST FWD OF LAVATORY ENTRANCE. R & R FLOOR PROXIMITY STRIP LIGHTS WIRE CONNECTOR AT PAX CTR FLOOR PANEL JUST FWD OF LAVATORY ENTRANCE IAW SWPM 20-50-01. OPERATIONS CHECKED GOOD IAW AMM 3SDR SIMA20140415014Connector · brokenEMERGENCY LIGHT STRIP NR 2 HAS A CONNECTOR BROKEN OFF OF WIRE, OLD CONNECTOR TAPED TO WIRE. R & R SPLICE ON NR 2 LIGHT STRIP IAW SWPM 20-21-00. OPERATIONS CHECKED GOOD IAW AMM 33-50-00.SDR SIMA20140415016Wire · brokenFORWARD EMERGENCY FLOOR LIGHT STRIP FOUND WIRES BROKEN TO LIGHT STRIP. R & R FWD EMERGENCY FLOOR LIGHT STRIP IAW AMM 33-50-12.SDR SWIA201437176Contactor · failedAFT HALF OF EMERGENCY LIGHTS WILL NOT TURN OFF. R & R CONTACTOR DC EMERGENCY BUSS, K0028, AND O/C RELAY K0148 IAW AMM.SDR AALA20140415004Wire · brokenSEAT 10D ESCAPE PATH LIGHT INOPERATIVE. TERMINATED BROKEN WIRE AT ESCAPE PATH LIGHT CONNECTOR AT SEAT 10D. OPERATIONS CHECKED NORMAL.SDR AALA20140415003Wire · brokenSEAT 11D EMERGENCY LIGHT INOPERATIVE. TERMINATED BROKEN WIRE AT ESCAPE PATH LIGHT CONNECTOR AT SEAT 11D, OPERATIONS CHECKED NORMAL.SDR USAA2014041600005Wire · damagedTHE EMERGENCY LIGHT INOPERATIVE AT BULKHEAD 2L. REPAIRED WIRING IAW ESPM CHAPTER 20-43-11, OPERATIONS CHECKED OK.SDR YENA20140415081Wire · damagedDURING HEAVY MAINTENANCE CHECK, FOUND LAVATORY A AFT OTBD LOWER WIRE DAMAGED FOR PANEL 221AW EMERGENCY EXIT LIGHT. REMOVED DAMAGED PORTION OF WIRE AND CRIMPED NEW CONTACT IAW ESPM 20-43-13. EXIT LIGHT, OPS CHECK GOOD IAW AMM 33-51-00-501.SDR YENA20140415080Wire · brokenDURING MAINTENANCE CHECK, FOUND EMERGENCY LIGHT AT SEAT 21ABC INOPERATIVE. FOUND WIRE BROKEN AT SEAT 21ABC WIRE HARNESS CONNECTOR 5751VC-A. R & R SEAT 21ABC HARNESS IAW AMM 33-51-19, C/W OPS CK IAW AMM 33-51-00.SDR SWIA201437130Connector · looseEMERGENCY EXIT LIGHT FRONT WALL IS INOPERATIVE. CONNECTED LOOSE CONNECTOR P341 BEHIND G3 GALLEY.SDR AALA20140416007Wire · damagedEMERGENCY LIGHTS FROM ROWS 26 TO 36 INOPERATIVE. FOUND DAMAGED WIRES ON L759 EXIT LIGHT. R & R LIGHT FIXTURE L759. OPERATIONS CHECKED NORMAL.SDR USAA2014041500002Wire Harness · faultySEAT ROW 20 EMERGENCY FLOOR LIGHT INOPERATIVE. REPLACED SEAT HARNESS AT ROW 20, OPERATIONS CHECKED OK.SDR SWIA201437132Wire · brokenFORWARD FLOOR EMERGENCY RED LIGHT DOES NOT ILLUMINATE. REPAIRED WIRING TO FWD RED LIGHTS IN FLOOR EMERGENCY LIGHTING STRIP.SDR DALA14023311806Wire · brokenFWD GALLEY EMERGENCY LIGHTS COME ON WHEN UNARMED AND ACFT SHUTDOWN. TROUBLSHOT IAW WDM 33-51-11, FOUND SENSE WIRE W832-004-22 AND PIN 4 AT M1208 SLED BROKEN NEAR L1 F/A SEAT. REPAIR IAW BWSP 20, OPS NORMAL.SDR DALA14022733146Wire · pulledEMERGENCY LIGHT AT ROW 19LT INOPERATIVE. FOUND WIRE PULLED FROM CONNECTOR. INSTALLED CONTACT AND REATTACHED CONNECTOR IAW ESPM 20-44-11. OPS CHECKED GOOD.SDR ASOA2014041610357Connector · disconnectedSERVICE DOOR INTERIOR EMERGENCY FLOOD LIGHT INOPERATIVE. RECONNECTED EMERGENCY LIGHT CONNECTOR IAW AMM 33-51-19, OPS CHECKED GOOD.SDR DALA14022870688Wire Harness · inoperativeEMERGENCY PATH LIGHTS AT SEAT 39D INOPERATIVE. REPLACED WIRE HARNESS FROM LIGHT ASSY TO FEED FROM FLOOR AT SEAT 39D. OPS CHECKED GOOD.SDR AALA20140412012Nut · looseCABIN CEILING EMERGENCY LIGHT AT STATION 358 LT INOPERATIVE. FOUND GND TERMINAL LOOSE ON FRAME AT STATION 351 UNDER CEILING PANEL. TIGHTENED NUT, OPERATIONS CHECKED NORMAL.SDR REXA2014041100375Power Cable · faultyORANGE STRIP AT SEAT 1C OF EMERGENCY EXIT FLOOR PATH LIGHTING INOPERATIVE. R & R POWER CABLE FOR FRONT EMERGENCY EXIT FLOOR PATH IAW AMM 33-51-01, OPERATIONS CHECKED GOOD.SDR REXA2014041100374Connector · brokenEMERGENCY LIGHT STRIP CONNECTOR BROKEN AT PANEL 261ALF. R & R EMERGENCY LIGHT STRIP CONNECTOR AT PANEL 261ALF IAW ESPM 20-17-31. OPERATIONS CHECKED GOOD IAW AMM 33-51-00-710-801.SDR AALA20140412002Wire · damagedEMERGENCY EXIT SIGN BY FWD LAVATORY WALL INOPERATIVE. TERMINATED WIRES AT QUICK DISCONNECTS FOR EXIT LIGHT AT FWD LAVATORY WALL. OPERATIONS CHECKED NORMAL.SDR REXA2014041000369Connector · faultyEMERGENCY FLOOR LIGHTS AT ROW 8 INOPERATIVE. R & R FAULTY CONNECTOR FOR EMERGENCY FLOOR LIGHTS AT ROW 8. EMERGENCY LIGHTS TESTED GOOD IAW AMM 33-51-01.SDR ASOA20140410045Connector · unsecureDURING MX INSPECTION, ROW 18 AFT EMERGENCY EXIT ROW EXIT SIGN WAS FOUND INOPERATIVE. MAINTENANCE INSPECTED AND SECURED A LOOSE CONNECTOR ON THE ROW 18 EMERGENCY EXIT SIGN. OPS CHECKED GOOD. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20140410033CWire Harness · burnedTHE CREW REPORTED BURNING ODOR IN THE CABIN AND GALLEY AREA. MAINTENANCE INSPECTED AND FOUND THE OVERHEAD LIGHT AT 5A TO BE BURNED. MAINTENANCE R & R THE CABIN LIGHT ELECTRICAL HARNESS. ALSO RELAMPED LIGHT. OPS CHECKS WERE GOOD.SDR SWIA201437104Wire · disconnectedEMERGENCY EXIT LIGHT, FLOOR BLUE STRIP DOES NOT ILLUMINATE AT ROW 6-7. RECONNECTED EMERGENY EXIT STRIP TOGETHER BY ROW 6-7.SDR HNAA2014040900124Connector · disconnectedEMERGENCY EXIT LIGHT AT RT SIDE IS INOPERATIVE. FOUND WIRE CONNECTOR TO LIGHT ASSY NOT CONNECTED. CONNECTED WIRING HARNESS, OPS CHECKD GOOD.SDR DALA14021470999Wire Harness · damagedDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY LIGHT AT ROW 15 WAS INOPERATIVE. MAINTENANCE REPLACED THE WIRE HARNESS AND FUNCTIONALLY CHECKED THE SYSTEM.SDR SWIA201437177Wire · brokenTHREE MOST FORWARD FLOOR EMERGENCY LIGHTS ARE INTERMITTENT. REPAIRED BROKEN WIRE TO FORWARD EMERGENCY FLOOR LIGHTS IAW AMM.
Back to JASC 3397