SDR AALA20120304002Connector · defectiveEMERGENCY PATH LIGHTING AT ROW 3D INOPERATIVE. REPLACED CONNECTOR PLUG AT ROW 3D. OPS CHECK NORMAL.SDR UALA2012030501332Cable · brokenEEL LIGHT AT DOOR 4 CROSS AISLE LEFT SIDE INOPERATIVE. REPAIRED BROKEN RIBBON CABLE, OPS TEST NORMAL.SDR DALA1212860617Wire · damagedLINE MAINTENANCE FOUND EMERGENCY EXIT PATH LIGHTS AT ROWS 3, 4, 5, 6 INOPERATIVE. REPAIRED WIRE PER BOEING SPWM CHAPTER 20, OPERATION NORMAL. (2012-D0230)SDR SIMA20120302011Wire · brokenDURING MAINTENANCE INSPECTION FOUND THE FLOOR PROXIMITY STRIP LIGHT WIRE AT FLOOR PANEL 251HF BROKEN. AIRCRAFT REMOVED FROM SERVICE. REPAIRED WIRE IAW AWM 20-00-03. OPS CHECKED GOOD. AIRCRAFT RETURNED TO SERVICE.SDR SIMA20120302009Wire · brokenDURING MAINTENANCE INSPECTION, FOUND EMERGENCY LIGHT AT FLOOR PANEL 231GF HAS ONE BROKEN WIRE. AIRCRAFT REMOVED FROM SERVICE. REPAIRED BROKEN WIRE IAW AWM 20-00--03. OPS CHECKED GOOD. AIRCRAFT RETURNED TO SERVICE.SDR SIMA20120302008Wire · damagedDURING MAINTENANCE INSPECTION, FOUND FLOOR PROXIMITY LIGHT STRIP EXTRUSION AT PANEL 231GF DAMAGED, 241BF HAS DAMAGED WIRES, 251DF IS DAMAGED. AIRCRAFT REMOVED FROM SERVICE. REMOVED AND REPLACED FLOOR PROXIMITY LIGHT STRIP EXTRUSION AT PANEL 231GF IAW AMM 33SDR UALA2012030201312Connector · faultyCEILING LIGHT ASSY L33145 ABOVE RT AFT LAV RBL 90, IS NON COMPLIANT PER AMM. REPLACED LIGHT ASSY CONNECTOR WITH NEW UPGRADED VIKING CONNECTOR, LIGHT CHECKS OKAY.SDR UALA2012030201311Connector · crackedCEILING LIGHT ASSY CONNECTOR DM33085C IS CRACKED, LOCATED ABOVE SEAT ROW 23HJ, STA 1076. REPLACED CONNECTOR, CHECKS GOOD.SDR UALA2012030201306Connector · faultyCEILING LIGHT ASSY L33146 ABOVE LT AFT LAV LBL 90, IS NON COMPLIANT PER AMM. REPLACED CONNECTOR ON LIGHT ASSY L33146 ABOVE LT AFT LAV WITH CONNECTOR VIKING BACC65AK211J, OP CHECKED GOOD.SDR UALA2012030201305Connector · faultyCEILING LIGHT ASSY L33145 ABOVE DOOR 2LT, CONNECTOR IS NON COMPLIANT PER AMM. REPLACED CONNECTOR ON LIGHT ASSY L33145 WITH CONNECTOR VIKING BACC65AK211P, OP CHECKED GOOD.SDR UALA2012030201304Connector · faultyCEILING LIGHT ASSY L33146 ABOVE DOOR 2LT CONNECTOR IS NON COMPLIANT PER AMM. REPLACED CONNECTOR ON LIGHT ASSY L33146 WITH CONNECTOR VIKING BACC65AK211P, OP CHECKED GOOD.SDR UALA2012030201303Connector · faultyCEILING LIGHT ASSY L33146 ABOVE DOOR 2RT, CONNECTOR IS NON COMPLIANT PER AMM. REPLACED CONNECTOR WITH VIKING BACC65AK211P, OPS GOOD.SDR UALA2012030201302Connector · faultyCEILING LIGHT ASSY L33145 ABOVE DOOR 3RT, IS NON COMPLIANT PER AMM. REPLACED LIGHT ASSY CONNECTOR WITH NEW UPGRADED VIKING CONNECTOR, CHECKS OKAY.SDR UALA2012030201301Connector · defectiveCEILING LIGHT ASSY L33146 ABOVE RT AFT LAV STA 1980, CONNECTOR IS NON COMPLIANT PER AMM. REPLACED CONNECTOR, CHECKS GOOD.SDR UALA2012030201300Connector · faultyCEILING LIGHT ASSY L33146 ABOVE AFT LT LAV STA 1980, CONNECTOR IS NON COMPLIANT PER AMM. REPLACED CONNECTOR. CHECKS GOOD.SDR DALA1212797003Wire · exposedDURING A MAINTENANCE VISIT, THE EMERGENCY FLOOR LIGHTING WIRES WERE EXPOSED AT DOOR 3L BULKHEAD. MAINTENANCE REPAIRED THE EMERGENCY FLOOR LIGHTING PER BSWP CHAP 20. OP CKS GOOD PER B777-200ER. (2012-D0227)SDR IPXA2172042Connector · unsecureOPS CHECK OF INTERIOR EMERGENCY LIGHTS FAILED TEST IAW PS1 CHECK. EPSU SHOWS INTERIOR LIGHTS FAULT DURING TEST BUT ALL LAMPS IN ALL INTERIOR EMERGENCY LIGHTS OPERATE NORMALLY. RESEATED CONNECTOR AT 29WL POWER SUPPLY AND EMERGENCY LIGHTS NOW PASS TEST IAW PSSDR USAA2012030500010Cable · defectiveSEAT ROW 22ABC EMERGENCY SEAT MOUNTED LIGHT INOPERATIVE. REMOVED AND REPLACED SEAT CABLE 5409VB IAW TR320-3350-11-0541. OPS CHECKED GOOD PER AMM 33-51-00-501.SDR UALA2012030101273Wire · damagedROW 37 A-C EMERGENCY LIGHT WIRING CUT. FOUND THE INSULATION ON ONE WIRE WAS DAMAGED. INSTALLED ELECTRICAL TAPE. NO STRANDS OF WIRE WERE CUT. REPAIR THE CABLE PER MM 20-53-20.SDR UALA2012022901256Connector · shortedACP'D CONT CK OF ALL DATA FEED PAIRS FROM OEU 3-1-1 TO 3-1-12. ALL CKS GOOD BUT FOUND THAT FROM OEU 3-1-12 (M23409) CONNECTOR DM23409A, PINS 11 TO 12, THRU THE TERMINATOR WAS 17 OHMS. RT SIDE WAS 120 OHMS. NEEDS TERMINATOR RESISTOR R23117 (MFG P-N CTER -120SDR SWAA2012031902413Ground Wire · brokenFWD LAVATORY EMERGENCY LIGHT GROUND WIRE IS BROKEN FWD OF L1 DOOR. REPAIRED CONNECTOR IAW SWPM & AMM.SDR SWIA201229891Pin · backed outFIRST FOUR FLOOR EMERGENCY LIGHTS ARE INOPERATIVE. (FLT 6359) FOUND FORWARD FLOOR EMERGENCY LIGHT CONNECTOR PIN OUT. PUSHED PIN IN PLACE.SDR DALA1213470963Wire Harness · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING AT ROW 2C IN THE CABIN, WAS INOPERATIVE. MAINTENANCE REPLACED THE WIRE HARNESS AND FUNCTIONALLY CHECKED THE SYSTEM.SDR REXA2012022900295Connector · defectiveCENTER EMERGENCY FLOOR LIGHTING INOP. REPLACED CENTER EMERGENCY FLOOR LIGHT STRIP CONNECTOR IAW CRJ200 AMM 33-51-01. OPS CHECK GOOD.SDR USAA2012030100008Connector · looseSEAT MOUNTED EMERGENCY LIGHT AT ROW 11 RIGHT INOPERATIVE. SECURED WALL CONNECTOR AT ROW 12 - SYSTEM OPERATIONAL CHECK GOOD.SDR TRBA20120229001Feeder Cable · brokenDURING B INSPECTION, FOUND EMERGENCY FLOOR PATH LIGHT AT SEAT 7B INTERMITTENT. THE ACFT WAS REMOVED FROM SERVICE. REPAIRED BROKEN CABLE ON EMERGENCY FLOOR LIGHT, REPLACED LIGHT BULB PERFORMED OPS CHECKED GOOD PER JIC 33-51-24. THE ACFT RETURN TO SERVICE.SDR SIMA20120228015Wire · brokenDURING MAINTENANCE INSPECTION FOUND THE NR 4 EMERGENCY LIGHT STRIP HAS BROKEN WIRE. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE NR 4 EMERGENCY LIGHT STRIP IAW EMB 145 AMM 33-50-12. THE OPERATIONAL CHECK WAS GOOD. THE AIRCRAFT WAS RETURNSDR SIMA20120228014Wire · brokenDURING MAINTENANCE INSPECTION FOUND THE SERVICE DOOR FORWARD LOWER TRIM SHROUD EXIT LIGHT HAS BROKEN WIRE. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE SERVICE DOOR LOWER TRIM SHROUD EXIT LIGHT IAW EMB 145 AMM 33-50-13. THE OPERATIONAL CHSDR SIMA20120228011Lead · brokenDURING B-INSPECTION FOUND THE EMERGENCY LIGHT STRIP NR 8 HAS A BROKEN LEAD. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE NR 8 EMERGENCY LIGHT STRIP AW EMB 145 AMM 33-50-12. THE OPERATIONAL CHECK WAS GOOD. THE AIRCRAFT WAS RETURNED TO SERSDR SWAA2012030501894Wire · brokenLT EMERGENCY LIGHT WIRE BROKEN. REPAIRED WIRE IAW WDM AND AMM.SDR SWAA2012030201846Wire · brokenL1 DOOR EMERGENCY EXIT LIGHT WIRE BROKEN. REPAIRED WIRE PER SWPM.SDR UALA2012022801233Connector · unsecureEMERGENCY LIGHT AT MAIN AFT GALLEY INOP AT LEFT FWD CORNER AND WALL AT DOOR 4L. SECURED CONNECTOR. EMERGENCY LIGHTS OPS CHECK NORMAL.SDR UALA2012022801230Connector · looseEMERGENCY LIGHTS AT SEATS 45JK-50JK INOP. SECURED LOOSE CONNECTION UNDER SEAT 49JK.SDR SIMA20120228003Wire · brokenDURING MAINTENANCE INSPECTION FOUND EMERGENCY LIGHT STRIP 3 HAS BROKEN WIRE. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED NR 3 EMERGENCY LIGHT STRIP IAW AMM 33-50-12, OPERATIONAL WAS CHECK GOOD. THE AIRCRAFT RETURNED TO SERVICE.SDR CA120227013Light · not grounded(CAN) RETRACTABLE WING LANDING LIGHTS NOT WORKING AT ALL. FOUND TO HAVE INSUFFICIENT GROUND CONTINUITY THROUGH PAINTED STRUCTURES FROM FACTORY GROUND PATH COULD BE FORCED THROUGH OTHER PATHS CAUSING ARCING.SDR VQI2012F00005Wire · disconnectedDURING THE MX CHECK, IT WAS NOTED THE WALL MOUNTED EXIT LIGHTED SIGN (FIN 90WL7) AT THE LOWER LT AFT ENTRY DOOR WOULD NOT COME ON DURING THE TEST. THE TECH GAINED ACCESS OT THE LIGHT ASSY AND FOUND THE GROUND WIRE CONTACT, 7439VS-B, HAD BECOME DISCONNECTED FRSDR UALA2012022701173Connector · saturatedEMERGENCY EXIT EEL LIGHTS INOP SEAT ROWS 45 THRU 53 LEFT, DOOR 4 LEFT FWD EXIT SIGN, DOOR 4 RIGHT AFT EXIT SIGN, LOWER WALL EEL ACROSS DOOR 4 LEFT, AND DOOR 4 GALLEY AREA LOWER WALL EEL. THIS IS A REPETITIVE PROBLEM IN THIS SPECIFIC AREA ON 84XX AIRCRAFT. FOSDR UALA2012022701172Connector · unsecureEMERGENCY EXIT EEL LIGHT INOP DOOR 5 LEFT GALLEY AREA LOWER AFT WALL. SECURED CONNECTOR, OPS CKS NORMAL.SDR AALA20120229020Connector · disconnectedSEAT 31G ESCAPE PATH LIGHT INOPERATIVE. RECONNECTED SEAT 31G ESCAPE PATH LIGHT CONNECTOR. OPS CHECK NORMAL.SDR DALA1211716301Wire · disconnectedDURING A MAINTENANCE VISIT, THE EMERGENCY FLOOR LIGHTS AT ROWS 10-12 ON THE RIGHT WERE FOUND TO BE INOPERATIVE. MAINTENANCE RECONNECTED THE WIRES AT ROW 10. SYSTEM OPERATION WAS NORMAL AFTER THE WIRES WERE RECONNECTED.SDR DALA1211706301Wire · disconnectedDURING A MAINTENANCE VISIT, THE EMERGENCY FLOOR LIGHT AT DOOR 3L WAS FOUND TO BE INOPERATIVE. MAINTENANCE RECONNECTED THE WIRES. SYSTEM OPERATION WAS NORMAL AFTER THE WIRES WERE RECONNECTED.SDR AALA20120228006Wire · pulledSEAT 35D EMERGENCY PATH LIGHT WIRING PULLED AWAY FROM LENS COVER. REPLACED EMERGENCY LIGHT ASSEMBLY FOR SEAT 35D EMEREGNCY LIGHT. OPS CHECK NORMAL.SDR CA120309006Wire · shorted(CAN) 10 MILES TO LANDING, BURNING ODOR WAS NOTED AND SHORTLY THEREAFTER SMOKE WAS SEEN COMING FROM THE AREA OF A RIVET ON THE FORWARD PART OF THE DOOR FRAME NEAR THE LOWER AFT CORNER OF THE PORT SIDE WINDSHIELD. LAST ELECTRICAL ITEM TURNED ON WAS THE VENT BLSDR AALA20120227004Wire · damagedMID FORWARD CEILING EXIT MARKER LIGHT AFT AT RIGHT AND LEFT NUMBER 2 DOORS INOPERATIVE. REPAIRED WIRE. OPS CHECK NORMAL.SDR SWIA201229798Wire · disconnectedEMERGENCY FLOOD LIGHT AT MAIN CABIN DOOR INOPERATIVE. (FLT 5224) CONNECTED POWER WIRES FOR EMERGENCY FLOOR FLOOD LIGHT AND FLOOR LEVEL EXIT SIGN.SDR UHLA2012022500079Connector · dirtyCOCKPIT EMERGENCY LIGHT INOP. CLEANED ELECTRIC CONNECTION AND RE-SECURED COCKPIT EMERGENCY LIGHT. OPS CHECK GOOD.SDR UALA2012022401120Cable · shortedEEL LIGHTS FROM ROW 35AB THROUGH AFT GALLEY INOP. EEL CABLE WET AND SHORTED, REPLACED EEL CABLE. ALL SEATS AND GALLEY STRIPS, OPS CHECKS NORMAL.SDR IPXA2M71927Connector · dirtyEMERGENCY LIGHTS DO NOT ILLUMINATE WHEN SWITCH IS PUT IN "ON" POSITION. TROUBLESHOT IAW FIM 33-52-00-1. CHECKED WIRING; CLEANED ELECTRICAL CONNECTORS. OPS CHECKED NORMAL. OK TO CONTINUE.SDR USAA2012022400018Wire · damagedSEAT MOUNTED EMERGENCY LIGHT INOPERATIVE 10R. REPAIRED WIRING SEAT MOUNTED EMERGENCY LIGHT 10. OPS CHECKED GOOD.SDR USAA2012022400017Wire · damagedSEAT MOUNTED EMERGENCY LIGHT ON 8R INOPERATIVE. REPAIRED WIRING SEAT MOUNT EMERGENCY LIGHT 8R. OPS CHECKED GOOD.
Back to JASC 3397