JASC 3397
Service difficulty reports · 22,664
Reports filed under 3397 · Light System Wiring, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3397' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3397' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA1208066712Wire · brokenLINE MAINTENANCE FOUND EMERGENCY PATH LIGHT WIRING AT ROW 25 DEF BROKEN. RECONNECTED AND STOWED WIRING HARNESS, OPERATION NORMAL.SDR UHLA2012020900048Connector · looseCOCKPIT EMERGENCY LIGHT DOES NOT ILLUMINATE. RE-SECURED EMERGENCY COCKPIT LIGHT PLUG IAW EMB 170 MM 33-50-03.SDR SWAA2012021001303Connector · looseRT OVERWING EMERGENCY EXIT AFT SIDE WALL SIGN IS INOP. SECURED CONNECTOR PER WDM AND MM.SDR ASOA201200433Ground Wire · disconnectedSERVICE DOOR LIGHTED EXIT SIGN INOPERATIVE. CONNECTOR GROUND TERMINAL END TO GROUNDING STUD IAW ESPM 20-20-00. OPS CHECKED GOOD. CSDR REXA2012020800214Wire · disconnectedMCD - WHITE EMERGENCY LIGHT STRIP INOP TAPPED COVER, NO CHANGE. RECONNECTED WIRE CONNECTORS FOR LIGHT STRIP NEAR PAX DOOR IAW ESPM AND OPS CHECKED LIGHT IAW AMM 33-51-19. NO DEFECTS NOTED.SDR SWAA2012020901258Wire · looseEMERGENCY ESCAPE PATH LIGHTING INOP BETWEEN ROW 7 TO 10. SECURED WIRE TO CONNECTOR AND REMOVED AND REPLACED LAMP PER SWPM.SDR DALA1207273272Wire · brokenDURING NON ROUTINE CHECK, FOUND THE EMERGENCY PATH LIGHT AT 4B INOPERATIVE. MAINTENANCE REPAIRED BROKEN WIRE AT CONNECTOR AND FUNCTIONAL CHECK WAS NORMAL. AIRCRAFT RETURNED TO SERVICE.SDR JJBA20120208003Connector · unsecureDURING PRE-FLIGHT INSPECTION, FLIGHT CREW NOTICED THAT AN EMERGENCY LIGHT FLOOR STRIP WAS INOPERATIVE. GROUND MX CREW RESECURED EMERGENCY LIGHT STRIP ELECTRICAL CONNECTOR. PERFORMED OPS CHECK OF EMERGENCY LIGHTING SYS, OPS CHECKS WERE SATISFACTORY. ACFT RELSDR YENA20120208432Pin · not seatedFLT 537 EWR-TPA, ON GROUND MAINTENANCE CHECK FOUND L2 AND R2 SERVICE DOOR EMERGENCY EXIT SIGNS LIGHTS INOPERATIVE. TROUBLESHOOT EMERGENCY LIGHT EXIT SIGNS L2 AND R2 SERVICE DOORS IAW WDM 33-51-08 FOUND PIN F BLOCK 4 FIN 7222VT NOT SEATED. RESET PIN TO BLOCK SDR UALA2012020900770Cable · brokenFOUND LAV 112 OTBD EEL LIGHT INOP. FOUND LIGHT CABLE BROKEN AND JUMPER CABLE BROKEN. REPLACED BOTH AND TESTED.SDR UALA2012020800759Cable · brokenFOUND LAV 112 OTBD EEL LIGHT INOP. FOUND LIGHT CABLE BROKEN AND JUMPER CABLE BROKEN. REPLACE BOTH AND TESTED.SDR UALA2012020800758Cable · faultySEAT ROW 25 KJH ELECTRO LUMINESCENT EMERGENCY STRIP LIGHT OPERATION IS INTERMITTENT = NOTE THIS IS AN IDT ITEM. FOUND BAD CABLE, REPLACED AND TESTED.SDR SIMA2012039001Wire · damagedDURING B-INSPECTION FOUND THE EMERGENCY LIGHTS INOPERABLEAT ROW 10 A. THE AIRCRAFT WAS REMOVED FROM SERVICE. SOLDERING WIRES AT EMERGENCY LIGHT STRIP IAW AWM STD PRACT 20-30-00. THE OPERATIONAL TEST CHECK WAS GOOD IAW W/C 33-700-11. THE AIRCRAFT WAS RETURNSDR JJBA20120206001Connector · unsecureFLOOR EMERGENCY ESCAPE PATH LIGHTING AT SEAT ROW 10-11, FOUND INOPERATIVE DURING FLIGHT CREW GROUND TEST. RESEATED CONNECTOR ON FLOOR EMERGENCY LIGHTS AT ROW 10-11. OPS CHECKED SATISFACTORY WITH NO ADDITIONAL DEFECTS.SDR UALA2012020600702Connector · looseUPPER DECK EMERGENCY LIGHTS AT SEAT 13 AND 14 ARE ALL OUT AND 15 AND 16 HAVE ONE EACH LIGHT INOP. SECURED CONNECTIONS AND OPS CHKD GOOD.SDR UALA2012020600698Connector · unsecureSEAT 23-25 HJK EMERGENCY LIGHTS IS INOP. SECURED CONNECTION TO LIGHTS.SDR UALA2012020600688Feeder Cable · damagedCLEANERS VACUUMED UP PORTION OF EEL LIGHTING AFT OF DOOR 1L. REPLACED FEEDER CABLE. GROUND CHECKS NORMAL.SDR ABXR2012020400024Wire · shortedDURING INSPECTION, FOUND WING ANTI-COLLISION LIGHTS POPS CIRCUIT BREAKER. REPAIRED SHORTED WIRING AND REPLACED SWITCH IAW SWPM.SDR SIMA20120203001Wire · brokenDURING B-INSPECTION FOUND THE NR 4 AND NR 5 EMERGENCY LIGHT STRIP HAS BROKEN WIRES. ALSO FOUND THE EMERGENCY LIGHT ON FORWARD LOWER SERVICE DOOR SHROUD PANEL HAS BROKEN WIRES. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE NR 4 & NR 5 EMERGSDR UHLA2012020300077Connector · disconnectedCOCKPIT EMERGENCY LIGHT INOP. RECONNECTED ELECTRICAL CONNECTOR ON THE COCKPIT EMERGENCY LIGHT IAW EMB 170 AMM 33-50-03. OPS CHECK GOOD.SDR MYWA201202030016Wire · brokenFOUND BROKEN WIRE ON BATTERY PACK CONNECTOR M1672 PIN 13. REPAIRED WIRE IAW AMM 20-38-12. OPS CHECKS NORMAL.SDR DALA1206680931Wire Harness · faultyDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY EXIT SIGN AT THE WING EXIT HATCH IN ROW 13DE WAS INOPERATIVE. MAINTENANCE REPLACED THE WIRE HARNESS AND FUNCTIONALLY CHECKED THE SYSTEM.SDR SIMA2012037004Connector · detachedDURING MAINTENANCE INSPECTION FOUND THE SERVICE DOOR EMERGENCY LIGHT IS INOPERATIVE. THE AIRCRAFT WAS REMOVED FROM SERVICE. FEMALE CONNECTOR ON AIRCRAFT SIDE BECAME DETACHED FROM ATTACHING WIRE. INSTALLED NEW CONNECTOR AND THE OPERATIONAL CHECK OF THE EMERGSDR SIMA201203401Connector · looseDURING MAINTENANCE INSPECTION FOUND EMERGECNY LIGHT FLOOR STRIPS 2 AND 3 NOT LIGHTING. THE AIRCRAFT WAS REMOVED FROM SERVICE. FOUND LOOSE CONNECTORS ON FLOOR STRIPS 2 AND 3, RECONNECTED CONNECTORS IAW EMB AMM 33-50-12-400-801-A STEP 2. THE OPERATIONAL CHECKSDR SWIA201229547Connector · looseEMERGENCY LIGHT ON SIDEWALL BY LEFT EMERGENCY DOOR OVERWING NOT LIGHTING UP. (SERVICE) RE-SECURED CONNECTION OF LIGHT ASSEMBLY.SDR SWIA201229521Wire · damaged(FLT 4759) CAPTAIN'S FLOODLIGHT WIRES WERE EXPOSED, ARCED, AND POPPED CIRCUIT BREAKER. REPLACED PILOT SIDE CONSOLE FLOOD LIGHT.SDR DALA1206166313Connector · looseDURING A MAINTENANCE VISIT, THE EMERGENCY ESCAPE PATH LIGHTS FROM ROWS 9-12 ON LEFT SIDE WERE FOUND TO BE INOPERATIVE. MAINTENANCE FOUND THE CONNECTOR LOOSE AT ROW 9 ON THE LEFT SIDE AND RECONNECTED IT. SYSTEM OPERATION WAS NORMAL AFTER THE CONNECTOR WAS RESDR AALA20120203TUL04Connector · damagedEMERGENCY LIGHTS IN FORWARD CABIN FROM ROW 20 INOPERATIVE. FOUND PINS PUSHED BACK AND SHORTING AT SEAT 10F. REPAIRED CONNECTOR AT SEAT 10F. OPS CHECK NORMAL.SDR UALA2012020200641Connector · unsecureEMERGENCY EXIT EEL LIGHT INOP SEAT ROW 23 LEFT. SECURED CONNECTOR, OPS CHECKS NORMAL.SDR DALA1205690984Wire Harness · defectiveDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING AT ROW 12DE IN THE CABIN, WAS INOPERATIVE. MAINTENANCE REPLACED THE SEAT WIRE HARNESS AND FUNCTIONALLY CHECKED THE SYSTEM.SDR UALA2012020200647Connector · unsecureEMERGENCY EXIT EEL LIGHT INOP SEAT ROW 45 RIGHT. SECURED LOOSE CONNECTOR.SDR UALA2012020200646Connector · unsecureEMERGENCY EXIT EEL LIGHT INOP SEAT ROW 40 RIGHT. SECURED CONNECTOR.SDR UALA2012020200642Connector · unsecureEMERGENCY EXIT EEL LIGHT INOP DOOR 4 LEFT GALLEY LOWER FORWARD WALL CROSSAISLE. SECURED CONNECTOR, OPS CHECKS NORMAL.SDR UALA2012020200640Connector · unsecureEMERGENCY EXIT EEL LIGHT INOP SEAT ROW 34 LEFT. SECURED CONNECTOR, OPS CKS NORMAL.SDR NOCA01912Wire · damagedEXIT LIGHT INOPERABLE L4 PASSENGER DOOR LOCATION AT FLOOR LEVEL. REPAIRED WIRING PER WDM 33-51-14, OPS CHECK GOOD.SDR SWIA201229553Wire · damagedFLOOR EMERGENCY LIGHT AT 7A IS OUT. (FLT 5403) REPAIRED FLOOR EMERGENCY LIGHT WIRE AT 7A.SDR ASOA20120201004Wire · brokenEMERGENCY LIGHT FLOOR STRIP INOP. R & R LIGHT STRIP. OPS CHECK GOOD.SDR SIMA2012034001Connector · defectiveDURING MAINTENANCE INSPECTION FOUND THE AFT FLOOR EMERGENCY STRIP LIGHT HAS A BROKEN PLUG. THE AIRCRAFT WAS REMOVED FROM SERVICE. REPLACED FLOOR PROXIMITY EMERGENCY LIGHT CONNECTOR IAW EMB WM 20-21-00. THE OPERATIONAL CHECK WAS GOOD. THE AIRCRAFT WAS RETURSDR ASOA201200354Connector · disconnectedEMERGENCY EXIT SIGN LIGHT IN FRONT OF LT SIDE NR 1 FIRST CLASS SEAT IS OUT. FOUND ELECTRICAL CONNECTOR P341 DISCONNECTED, RECONNECTED ELECTRICAL CONNECTOR IAW ESPM 20-26-00, SYS OPS CHECKED GOOD IAW AMM 33-51-00-710-801.SDR UALA2012020200618Connector · looseSEAT ROW EMERGENCY LIGHT 45ABC IS INOP. SECURED CONNECTION.SDR SWIA201229452Connector · disconnectedAFT HALF OF EMERGENCY STRIP FLOOR LIGHTS ARE OUT. (FLT 4748) CONNECTION ON FLOOR STRIP IN FRONT OF LAVATORY DISCONNECTED. RECONNECTED STRIP AS NEEDED.SDR DALA1205343266Wire Harness · damagedDURING NON ROUTINE CHECK, FOUND THE EMERGENCY ESCAPE PATH LIGHT WITH BROKEN HARNESS AT SEAT 19. MAINTENANCE REPAIRED BROKEN WIRE HARNESS AT CONNECTOR AND FUNCTIONAL CHECK WAS NORMAL. AIRCRAFT RETURNED TO SERVICE.SDR SWAA120644Splice · disconnectedDURING SCHEDULED SPV CHECK, FOUND RT EMERGENCY EXIT BULLNOSE LIGHT INOP AT ROW 15. RECONNECTED SPLICE AT LIGHT. REPAIRED LIGHT ASSY PER WDM AND MM.SDR SWIA201229440Wire · brokenOVERHEAD EMERGENCY EXIT LIGHT PANEL AT ROW 9 IS OUT. (FLT 6264) REPAIRED TERMINAL WIRE AT EMERGENCY EXIT ROW 9.SDR DALA1205060937Wire · brokenDURING LINE CHECK, MAINTENANCE FOUND THAT A EMERGENCY PATHWAY LIGHT IN THE VENTRAL STAIRWAY WAS INOPERATIVE. MAINTENANCE FOUND BROKEN WIRES BEHIND THE LIGHT AND RE-TERMINATED THE LIGHT ASSEMBLY. THE SYSTEM RETURNED TO NORMAL OPERATION.SDR DALA1205050937Wire Harness · defectiveDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING AT ROW 16DE IN THE CABIN, WAS INOPERATIVE. MAINTENANCE REPLACED THE WIRE HARNESS AND FUNCTIONALLY CHECKED THE SYSTEM.SDR DALA1204981806Connector · looseEMERGENCY PATH LIGHTS AT SEAT 21B ARE INOPERATIVE. MTC FOUND LOOSE CONNECTOR AND SECURED.SDR DALA1207405643Connector · looseDURING LINE CHECK MAINTENANCE FOUND EXIT SIGN AT 3R INOP. MAINTENANCE RECONNECTED LOSE CONNECTOR. EXIT SIGN NOW WORKS OK PER AMM 33-51.SDR DJFA20120126010Wire · burnedDURING TROUBLESHOOTING OF A PILOT DISCREPANCY FOR THE LAV VANITY LIGHTS INOPERATIVE, MAINTENANCE TECHNICIANS FOUND WIRING THAT APPEARS TO HAVE BURNED THROUGH NEAR AN OXYGEN LINE IN THE PSU. ADDITIONALLY, 2 LIGHTING INVERTERS WERE FOUND FAILED. THE BURNED WIRSDR UALA2012012600543Wire · corrodedMAIN GALLEY DOOR 4 LT FWD AND SIDE EMERGENCY LIGHT INOP. REPAIRED WET AND CORRODED WIRING.
Back to JASC 3397