JASC 3397
Service difficulty reports · 22,664
Reports filed under 3397 · Light System Wiring, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3397' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3397' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2012011600297Connector · looseEMERGENCY EXIT LIGHT INOPERATIVE, SEAT ROW 55 LEFT. CONNECTED LOOSE CONNECTOR, OPS NORMAL.SDR SWIA201229258Wire · disconnectedFIRST 4 SEGMENTS OF EMERGENCY LIGHT FLOOR STRIPS ARE OUT. (FLT 6292) RECONNECTED WIRE CONNECTOR AT SEAT 5 CB.SDR UALA2012011600309Connector · disconnectedEMERGENCY EXIT EEL LIGHT INOP DOOR 5 RIGHT GALLEY AREA LOWER AFT WALL. CONNECTED CONNECTOR AT LIGHT ASSY, OPS NORMAL.SDR UALA2012011600287Connector · saturatedEMERGENCY EXIT EEL LIGHTS INOP SEAT ROWS 45 THRU 53 LEFT, DOOR 4 LEFT FWD EXIT SIGN, DOOR 4 RIGHT AFT EXIT SIGN, LOWER WALL EEL ACROSS DOOR 4 LEFT AND DOOR 4 GALLEY AREA LOWER WALL EEL. THIS IS A REPETITIVE PROBLEM IN THIS SPECIFIC AREA ON 84XX AIRCRAFT. FOUSDR GLBA201201141Wire · chafedBOTTOM OVERWING EMERGENCY LIGHT DO NOT ILLUMINATE ON THE LT OR RT WING. MX REPAIRED CHAFED WIRES ON THE RT AFT EXT EMERGENCY LIGHTS, IAW AIM 14.3.0, OPS CHECKED GOOD IAW MM 33-50-00.SDR USAA2012011700032Wire Harness · faultySEAT MOUNTED EMERGENCY EXIT LIGHTS INOPERATIVE AT ROW 14 LEFT. REMOVED AND REPLACED WIRE HARNESS ASSEMBLY. OPS CHECKED GOOD.SDR USAA2012011700031Wire Harness · faultySEAT MOUNTED EMERGENCY EXIT LIGHTS INOPERATIVE AT ROW 6 LEFT. REMOVED AND REPLACED WIRE HARNESS ASSEMBLY. OPS CHECKED GOOD.SDR VJ3R2012FA0000028Circuit Breaker · brokenPILOT REPORTED TAXI LIGHT INOPERATIVE. ON TROUBLESHOOTING THE TECH FOUND THE CIRCUIT BREAKER AT FAULT. INSTALLED NEW CIRCUIT BREAKER. OPS CHECKED OK. SWITCH THAT FAILED WAS INSTALLED TO COMPLY WITH AD 2008-13-17. THIS ACFT HAS HAD 4 OF THE IMPROVED CIRCUITSDR VJ3R2012FA0000027Circuit Breaker · brokenPILOT REPORTED NAVIGATION LIGHTS INOPERATIVE. ON TROUBLESHOOTING, FOUND THE CIRCUIT BREAKER AT FAULT. INSTALLED NEW CIRCUIT BREAKER. OPS CHECKED OK. SWITCH THAT FAILED WAS INSTALLED TO COMPLY WITH AD 2008-13-17. THIS ACFT HAS HAD 6 OF THE IMPROVED CIRCUIT BSDR DALA1208670910Connector · disconnectedDURING LINE CHECK, MAINTENANCE FOUND THAT THE FIRST EMERGENCY PATHWAY LIGHTING ON THE CATWALK IN THE TAIL COMPARTMENT WAS INOPERATIVE. MAINTENANCE FOUND PIN AND RECEPTACLE AT THE CONNECTOR NOT PROPERLY SEATED. RESEATED CONNECTOR AND THE SYSTEM RETURNED TO NOSDR NOCA00712Wire · brokenSEAT ROWS 1F AND 31F EMERGENCY LIGHTS INOP. FOUND BROKEN WIRES AT FLOOR LEVEL SEAT BASE. RE-SPLICED WIRES PER SWPM 20-30-12, LIGHT OPERATION CHECKS OK.SDR DALA1201485650Wire · openDURING LINE CHECK MAINTENANCE FOUND EMERGENCY PATH LIGHTS ROW 29-33 INOP. MAINTENANCE REPAIRED OPEN WIRE UNDER SEAT 29A. ALSO REPLACED JIFFY JUNCTIONS SPLICE AS PER SWPM 20-90-14. OPERATION OF PATH LIGHT NOW CHECK OK PER AMM 33-51.SDR DALA1204311812Harness · defectiveEMERGENCY PATH LIGHTS AT SEAT 27B ARE INOPERATIVE. JUMPER HARNESS WAS REPLACED. SYSTEM OPERATION IS NORMAL.SDR SWAA1201119Wire · brokenG1 GALLEY EXIT SIGN SPLICES BROKEN. REPAIRED WIRE PER BS WPM.SDR SWIA201229261Connector · disconnectedEMERGENCY FLOOR TRACK LIGHTING ARE OUT FROM ROW 2-6. (SERVICE) TIGHTENED LOOSE TRACK LIGHTING STRIPS CONNECTION AT ROW 6.SDR SWIA201229241Connector · out of adjustNR 7 EMERGENCY LIGHT STRIP IS OUT. (SERVICE) ADJUSTED CONNECTOR.SDR SIMA2012012001Wire · cutDURING MAINTENANCE BASE INSPECTION FOUND THE AFT FLOOR EMERGENCY LIGHT STRIP WIRE CUT. THE AIRCRAFT WAS REMOVED FROM SERVICE. INSTALLED AFT FLOOR EMERGENCY LIGHT STRIP IAW EMB AMM 33-50-12. THE OPERATIONAL CHECK WAS GOOD. THE AIRCRAFT WAS RETURNED TO SERVISDR UALA2012010900167Connector · looseEMERGENCY CROSSOVER LIGHT BETWEEN DOORS 5L & 5R IS INOP. REPAIRED LOOSE CONNECTION.SDR UALA2012010900166Connector · shortedEMERGENCY EXIT SIGN AT DOOR 1L IS INOPERATIVE. REPAIRED SHORT CIRCUIT UNDER CARPET.SDR 2012FA0000016Circuit Breaker · failedPILOT REPORTED BEACON LIGHT INOP. ON TROUBLESHOOTING THE TECH FOUND THE BEACON LIGHT CIRCUIT BREAKER AT FAULT. INSTALLED NEW BEACON LIGHT CIRCUIT BREAKER. OPS CHECKED OK.SDR 2012FA0000015Circuit Breaker · failedPILOT REPORTED BEACON LIGHT INOPERATIVE. ON TROUBLESHOOTING, THE TECH FOUND THE BEACON LIGHT CIRCUIT BREAKER AT FAULT. INSTALLED NEW BEACON LIGHT CIRCUIT BREAKER. OPS CHECKED OK.SDR 2012FA0000014Circuit Breaker · failedPILOT REPORTED LANDING LIGHT INOPERATIVE. ON TROUBLESHOOTING, FOUND THE LANDING LIGHT CIRCUIT BREAKER AT FAULT. INSTALLED NEW LANDING LIGHT CIRCUIT BREAKER. OPS CHECKED OK.SDR UALA2012010900153Connector · unsecureEMERGENCY EXIT LIGHT INOPERATIVE SEAT ROW 45 LEFT. SECURED CONNECTOR, OPS CHECKED NORMAL.SDR UALA2012010900152Connector · unsecureEMERGENCY EXIT LIGHT INOPERATIVE SEAT ROW 22 LEFT. SECURED CONNECTOR, OPS CHECKED NORMAL.SDR DALA1201143250Wire · brokenDURING NON ROUTINE CHECK, FOUND SEAT MOUNTED EMERGENCY EXIT PATH LIGHT AT 9ABC INOPERATIVE. MAINTENANCE REPAIRED BROKEN WIRE AND OPERATIONAL CHECK WAS NORMAL. AIRCRAFT RETURNED SERVICE.SDR UALA2012010600131Connector · unsecureEMERGENCY LIGHT ROW 41 LT INOPERATIVE. RESECURED CONNECTOR. OP CHECKED NORMAL.SDR TRBA201200902Fuse · inoperativeCREW REPORTED AN ELECTRICAL SMOKE ODOR, REPORTED AT CARGO 4. ACFT WAS REMOVED FROM SERVICE. CHECKED CABIN ENTRANCE LIGHT AND SERVICE DOOR LIGHT SOCKETS AND FOUND BROKEN. R & R FUSE, OPS CHECKED GOOD. THE ACFT WAS RETURNED TO SERVICE.SDR UALA2012010600132Wire · out of positionTHE 4 LT EXTERIOR FUSELAGE EMERGENCY EXIT LIGHT INOP. FOUND SECTION OF EMERGENCY AISLE LIGHTS, AND ONE EMER EXIT LIGHT AND SIGN LIGHT AND DOOR 4L EXT LIGHT IS OUT. ALL RECEIVE POWER FROM M10818 POWER SUPPLY, REF WDM 33-51-15 PG 1. (ON ORDER B29). FOUND OPENSDR DALA1201123164Wire · brokenEMERGENCY LIGHTS AT ROW 9L INOPERATIVE. MAINTENANCE FOUND TWO WIRES BROKEN. INSTALLED ENVIRONMENTAL SPLICES. OPERATIONAL CHECK IS NORMAL.SDR DALA1200991501Wire · disconnectedSEAT 32AB PATH LIGHT INOP WIRES BROKEN AT SIDEWALL DISCONNECT. RECONNECTED WIRES AT SIDEWALL AT SEAT 32AB. ETOPS CATEGORY 'E': PROBLEMS WITH SYSTEMS CRITICAL TO ETOPSSDR DALA1200889009Connector · brokenDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING AT ROW 14DE IN THE CABIN, WAS INOPERATIVE. MAINTENANCE FOUND THE CONNECTOR IN THE SEAT TO WALL WIRE HARNESS BROKEN. MCO/PLC PER MEL 33-00-24.SDR USAA2012010900030Wire · brokenSEAT ROW 8L EMERGENCY EXIT LIGHT INOPERATIVE. REPAIRED BROKEN WIRE AT SEAT 8L EMERGENCY EXIT LIGHT. OPS CHECKED GOOD.SDR NOCA00612Connector · looseEMERGENCY LIGHTS FROM 23AB TO 26AB INOP. TROUBLESHOT EMERGENCY LIGHTS FROM 23AB TO 26AB AND FOUND LOOSE CONNECTORS. RECONNECTED MM THE LIGHT AND PERFORMED LAMP TEST AS PER REF B767 AMM 33-51-11, TEST NORMAL.SDR NOCA00412Connector · looseALL CROSS AISLE EMRGENCY LIGHT INOP AT ROW 27CDE. TROUBLESHOT ALL CROSS AISLE EMERGENCY LIGHT AT ROW 27CDE AND FOUND LOOSE CONNECTOR. RECONNECTED THE LIGHTS AND PERFORMED LAMP TEST AS PER REF B767 33-51-00, TEST NORMAL.SDR DALA1201093760Connector · shortedEMERGENCY LIGHT TEST FOUND PATH LIGHTS ROW 10-15 INOP. FOUND CONNECTOR AT ROW 14 SHORTED, REPLACED FUSES AND RE-TERMINATED CONNECTOR AND TESTS OK.SDR DALA1200870997Wire · brokenDURING LINE CHECK, MAINTENANCE FOUND THAT THE RED EMERGENCY PATHWAY LIGHTING IN THE GALLEY WAS INOPERATIVE. MAINTENANCE FOUND A BROKEN WIRE UNDER THE CARPET AND REPLACED THE LIGHT ASSEMBLY. THE SYSTEM RETURNED TO NORMAL OPERATION.SDR DALA1200860963Wire · shortedDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN ROWS 1-12 AND ROWS 31-38 OF THE CABIN WERE INOPERATIVE. MAINTENANCE FOUND A WIRE SHORTED AT THE EXIT IDENTIFIER BY DOOR L1 AND APPLIED THE PROPER REPAIR.SDR SWAA120117Wire · damagedDURING SCHEDULED MV2 CHECK, FOUND EEPLS WIRE INOP AT ROW 22. REMOVED AND REPLACED WIRE PER MM.SDR SIMA201200604Wire · brokenDURING MAINTENANCE BASE INSPECTION FOUND THE NR 3 EMERGENCY FLOOR LIGHT STRIP HAS A BROKEN WIRE. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE LEFT NR 3 EMERGENCY LIGHT IAW EMB 145 AMM 33-50-12. THE AIRCRAFT WAS RETURNED TO SERVICE.SDR DALA1300776805Wire · looseDURING LINE CHECK, MX FOUND MID GALLEY FORWARD EMERGENCY LIGHT INOPERATIVE. MX REPAIRED LOOSE WIRE AND REPLAMPED LIGHT. LIGHT OPERATES NORMAL.SDR SWAA2012021001312Connector · defectiveEMERGENCY EXIT LIGHT AT SEAT ROW 23 BULLNOSE INOP. FOUND WIRE PULLED OUT OF CONNECTOR. REPLACED CONNECTOR IAW SWPM AND AMM.SDR UALA2012010500119Connector · damagedEMERGENCY LIGHT INOPERATIVE ROW 57 RT. REPAIRED CONNECTOR, CHECKED OKAY.SDR DALA1201071812Wire Harness · disconnectedDURING DRC MAINTENANCE FOUND EMERGENCY EXIT SEAT LIGHTS AT ROWS 22AB TO 26AB INOPERATIVE. THE SEAT HARNESS AT ROW 22AB IS DISCONNECTED AND RECONNECTED THE HARNESS. SYSTEM OPERATION IS NORMAL.SDR DALA1201061505Connector · defectiveEMERGENCY ESCAPE PATH LIGHTS AT SEAT 24F ARE INOPERATIVE. MAITENANCE RE-TERMINATED CONNECTOR. SYSTEM OPERATION IS NML.SDR DALA1201050191Wire Harness · defectiveEMERGENCY PATH LIGHTS AT SEAT 38B ARE INOPERATIVE. MTC REPLACED THE HARNESS. SYSTEM OPERATION IS NORMAL.SDR DALA1200840661Connector · faultyLINE MAINTENANCE INSPECTION FOUND EMERGENCY LIGHT AT SEAT 25 INOPERATIVE. FAULTY WIRE CONNECTOR RE-PINNED AND LIGHT OPERATION NORMAL.SDR DALA1200830661Wire · damagedLINE MAINTENANCE INSPECTION FOUND EMERGENCY LIGHT AT SEAT 40 INOPERATIVE. FAULTY WIRE SPLICED AND LIGHT OPERATION NORMAL.SDR USAA2012010500001Connector · disconnectedSEAT MOUNTED EMERGENCY LIGHT ON SEAT 8C IS INOPERATIVE. MAINTENANCE FOUND CONNECTOR 5751VC DISCONNECTED - RECONNECTED 5751VC.SDR UALA2012010300040Connector · dirtyLAVATORY BY BUSINESS GALLEY, EMERGENCY LIGHT FLICKERS. CLEANED SECTION CONNECTORS AS PER AMM, ALL OPS OKAY. OPS CHECKED AND ALL OKAY.SDR DALA1200676316Wire · brokenDURING A MAINTENANCE VISIT, THE EMERGENCY FLOOR LIGHT FORWARD OF SEATS 35 D-G WERE FOUND TO BE INOPERATIVE. MAINTENANCE FOUND BROKEN WIRES AND REPLACED THE LIGHT ASSEMBLY AT SEAT 34 D-G. SYSTEM OPERATION WAS NORMAL AFTER THE LIGHT ASSEMBLY WAS REPLACED.
Back to JASC 3397