SDR UALA2010020200421Feeder Cable · saturatedEMERGENCY LIGHT ROW 45 TO 51 LT INOP. REMOVED WATER COVERING FEEDER. CHECKS OK.SDR UALA2010020200420Feeder Cable · saturatedAFT GALLEY WALL EMERGENCY LIGHT FWD AND SIDE WALL LT INOP. REMOVING WATER COVERING FEEDER CABLE FIXED PROBLEM.SDR SIMA201003401Wire · brokenDURING MAINTENANCE BASE INSPECTION FOUND THAT THE LEFT NR 1 EMERGENCY LIGHT STRIP HAS A BROKEN WIRE. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED BOTH CONNECTORS IAW EMB 145 SWPM 20-21-00. THE AIRCRAFT WAS RETURNED TO SERVICE.SDR DALA102649852Wire · looseDURING LINE CHECK, MX FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN ROWS 14-18 OF THE CABIN WERE INOPERATIVE. MX FOUND A LOOSE WIRE IN THE CONNECTOR, REPAIRED THE CONNECTOR PIN AND THE SYS RETURNED TO NORMAL OPERATION.SDR AALA20100202DFW06Wire · unsecureESCAPE PATH LIGHT WIRING NOT STOWED AT 33D AVU BOX. SECURED ESCAPE PATH LIGHT WIRING AT 33D. OPS CHECKED NORMAL.SDR SWAA100597Connector · looseDURING SCHEDULED 12Y CHECK, FOUND RT EMERGENCY EXIT BULLNOSE LIGHT INOP AT ROW 21. SECURED CONNECTORS PER SWPM.SDR SWAA100596Connector · looseDURING SCHEDULED 12Y CHECK, FOUND LT EMERGENCY EXIT BULLNOSE LIGHT INOP BETWEEN ROW 1 TO ROW 22. SECURED CONNECTORS PER SWPM.SDR AALA20100131LHR01Wire · damagedEMERGENCY LIGHTS FOR SEAT 11D INOPERATIVE. REPAIRED WIRING IN SEAT LOOM UNDER SEAT 11E. OPS CHECKED NORMAL.SDR SWIA201023614Connector · dirtyALL EMERGENCY LIGHTS ARE INOP WHEN SELECTED TO ON POSITION. (FLT 6381) CLEANED JB12 CONNECTOR.SDR DL757100231Wire · damagedPASSENGER SEAT 26D EMERGENCY LIGHTING SEAT MOUNTED LIGHTS INOP. DAMAGED 26 D LIGHT FUNCTIONAL. FOUND LIGHT AT 24D INOP. REPLACED WIRE CONNECTOR. CHECKS GOOD. MCO REMOVED.SDR UALA2010020100392Feeder Cable · saturatedEMERGENCY LIGHTS INOP: SEATS 45-53L, DOOR 4L FWD LIGHT, DOOR 4R AFT, AFT GALLEY FWD AND LT LOWER WALL. COMMON PROBLEM. REMOVED A LOT OF WATER FROM UNDER FLOOR MAT COVERING FEEDER CABLE. CHECKS OK.SDR DALA102563274Wire · brokenTEST OF EMERGENCY LIGHTS FOUND SEAT 4 PATH LIGHT INOP, REPAIRED BROKEN WIRE UNDER SEAT AND CHECKS OK.SDR MASA2010013100100Connector · dirtyTWO (2) FORWARD EMERGENCY FLOOD LIGHTS INOP. MX CLEANED CONNECTORS ON BATTERY PACK 2.SDR UALA2010020800479Connector · out of toleranceRED EMERGENCY ESCAPE LIGHT INOP AT SEAT 12C MORE TIME NEEDED TO TROUBLESHOOT. RELAMP NO HELP. ALL OTHER ESCAPE LIGHTS OPERATE NORMAL IN COMPLIANCE WITH MEL 3350C. FOUND WIRES PULLED OUT OF CONNECTOR AT SEAT LIGHT, REPLACED CONNECTOR AND SECURED, OPS CK OF ESDR DLM88100236Wire · unsecureEMERGENCY EXIT ROW LIGHTS AT ROW 10 AND 20 INOP. SECURE CONTACT. OPS CK NML.SDR USAA20100201SB014Wire · damagedORD - MAINTENANCE REPORTED THE FLOOR LEVEL EMERGENCY PATH LIGHTS AT SEAT ROWS 4 AND 5 INOPERATIVE. MAINTENANCE REPAIRED EMERGENCY PATH LIGHTING SYSTEM WIRING AT SEAT ROW 4, LEFT SIDE, PER WDM 33-51-41. OPERATIONAL CHECK NORMAL.SDR DALA102553247Connector · brokenTEST OF EMERGENCY LIGHTS FOUND SEAT 16 PATH LIGHT INOP, REPAIRED BROKEN CONNECTOR AT SEAT TRACK AND CHECKS OK.SDR USAA20100201SB013Connector · disconnectedORD - MAINTENANCE REPORTED THE EMERGENCY LIGHT ON SEAT 5A INOPERATIVE. MAINTENANCE RECONNECTED HARNESS PLUG UNDER SEAT ROW 5A. OPERATIONAL CHECK GOOD.SDR UALA2010012900373Feeder Cable · faultyEMERGENCY EXIT LIGHT INOP. DOOR 5 RT AFT LOWER WALL. REPLACED POWER FEEDER CABLE. OPS CKS NORMAL.SDR UALA2010012900372Connector · unsecureEMERGENCY EXIT LIGHT INOP. LOWER WALL ACROSS DOOR 4 RT. SECURED CONNECTOR. OPS CK NORMAL.SDR UALA2010012900367Feeder Cable · shortedEMERGENCY EXIT LIGHTS VERY DIM SEAT ROWS 45 THRU 53 LT, DOOR 4 LT FWD EXIT SIGN, DOOR 4 RT AFT. EXIT SIGN, LOWER WALL EMERGENCY LIGHT ACROSS DOOR 4 LT, AND DOOR 4 GALLEY AREA LOWER WALL EMERGENCY LIGHT. REMOVED WATER FROM FEEDER CABLE. RESECURED. CHECKS OK.SDR UALA2010012900364Feeder Cable · faultyEMERGENCY EXIT LIGHT INOP. LOWER WALL ACROSS DOOR 3 LT. REPLACED FEEDER. CHECKS OK.SDR USAA2010012990217Wire · brokenFLT 605 - PHX - EEL - SEAT ROW 22 LEFT EMERGENCY LIGHT HAS BROKEN WIRE AT CONNECTOR. MAINTENANCE REMOVED AND REPLACED TERMINAL LUGS AT CONNECTOR ROW 22 LEFT.SDR DL757100214Wire · brokenEMERGENCY PATH LIGHTS INOP 28D AFT. REPAIRED BROKEN WIRE AT ROW 29D, CKS GOOD.SDR DALA102543233Connector · damagedDURING TEST PATH LIGHT SEAT 3B WAS INOP, SECURED LOOSE PIN IN PLUG AND TEST OK.SDR UALA2010012800355Wire · damagedEMERGENCY LIGHT WIRES CUT ON WALL ACROSS FROM 1L CLOSET. NEED TO HAVE FEMALE PLUG SPLICED TO BE ABLE TO CONNECT NEW EMERGENCY LIGHT THAT WAS INSTALLED. CUT IS IN FLAT WIRE, WILL NEED NEW LIGHT ASSY. PARTS NEEDED 5879-1 AND 5863-1 LEAD IN CABLE. REPAIRED EMERSDR UALA2010012800341Feeder Cable · disconnectedAFT GALLEY AREA BTWN DOORS 4L & 4R CROSS AISLE AND SIDEWALL EMERGENCY LIGHT(S) ARE INOP. SEATS 45ABC -51ABC. FOUND AFT GALLEY EMERGENCY LIGHT FEEDER CABLE AND CROSS AISLE EEMERGENCY LIGHT ASSY BAD. EMERGENCY LIGHT ASSY PCN 560 -4674. ORDERED LIGHT ASSY. NEESDR USAA2010012990225Connector · disconnectedFLT 223 - BOS-PHX - EMERGENCY LIGHTS - ROW 14 FLOOR LEVEL EMERGENCY LIGHT INOPERATIVE. FOUND LIGHT DISCONNECTED. RECONNECTED CONNECTOR. OPERATIONAL CHECK WAS GOOD.SDR DALA101856316Wire · damagedDURING LINE CHECK, MX FOUND ALL FWD ZONE RT EMERGENCY LIGHTS INOPERATIVE. MX REPAIRED WIRING. OPS CHECK GOOD.SDR SWAA100489Connector · looseDURING SCHEDULED 14Y CHECK, FOUND LT EMERGENCY EXIT BULLNOSE LIGHT INOP BETWEEN ROW 10 TO ROW 16. SECURED CONNECTOR PER MM.SDR 2010FA0000077Circuit Breaker · failedWHEN PILOT SELECTED LANDING LIGHT, LIGHT DID NOT WORK. TECH TROUBLESHOT AND FOUND FAULT TO BE WITH LANDING LIGHT CIRCUIT BREAKER, INTERNAL FAILURE OF CIRCUIT BREAKER.SDR AALA20100126MIA06Connector · not seatedEXTERIOR EMERGENCY LIGHT AT LEFT NUMBER FOUR DOOR INOPERATIVE. RESEATED EMERGENCY LIGHT CONNECTOR AT LEFT NUMBER FOUR DOOR.SDR DL757100212Wire Harness · inoperativeDURING CHECK, MX FOUND SEAT 3CD SEAT MOUNTED EMERGENCY FLOOR LIGHT INOPERATIVE. MX REPLACED THE UNDERSEAT HARNESS ASSY AND LAMP. OPS CHECK GOOD.SDR DL764100207Connector · disconnectedEMERGENCY LIGHTS INOP AT 38GF-40GF. FOUND CONNECTOR DISCONNECTED AT SEAT 40GF. CONNECTED PLUG EMER LIGHTS CK GD.SDR F3LA2010012900323Connector · inoperativeREFERENCE NON ROUTINE C078794. DURING C3 C CHECK INSP NOTED THE OPS TEST OF THE EMERGENCY LIGHTS WITH THE MCDU FAULTING. MX REPAIRED IAW AMM 33-51-38-000-001, AMM 33-51-38-400-001, AMM 25-62-44-000-002 AND AMM 33-51-00-710-001.SDR UALA2010012700336Connector · damagedFROM AISLE ROW 9C BACK TO MID CABIN EMERGENCY LIGHT STRIP INOPERATIVE. REPAIR POWER CONNECTOR, CHECKS NORMAL.SDR TRBA2010002Wire · disconnectedEMERGENCY LIGHT AT BOTTOM OF MAIN CABIN DOOR INOPERATIVE. RECONNECTED EMERGENCY LIGHT WIRES WITH SPLICE IAW SRM 20-43-13. OPT CHECKED GOODSDR DL764100185Connector · disconnectedEMERGENCY LIGHTS INOP AT 38GF-40GF. FOUND CONNECTOR DISCONNECTED AT SEAT 40GF. CONNECTED PLUG EMER LIGHTS CK GD. (FOUND DURING OVERNIGHT CHECK) CATEGORY 'E': PROBLEMS WITH SYS CRITICAL TO ETOPS.SDR SWIA201023553Connector · looseFLOOR LEVEL EMERGENCY LIGHTS AFT OF EMERGENCY ROW INOP. (FLT 4509) RE-SECURED CONNECTOR.SDR SWIA201023539Connector · dirtyEMERGENCY LIGHTS FAIL TO ILLUMINATE WHEN TURNED ON. (FLT 6695) CLEANED CONNECTOR AT JB-12.SDR UALA2010012500301Connector · unsecureEMERGENCY LIGHT AT BOTTOM OF WALL, AFT GALLEY AT DR5 RT, INOP. RESECURED EMERGENCY LIGHT CONNECTOR. OPS CK NORMAL.SDR UALA2010012500300Connector · unsecureEMERGENCY LIGHT ROW 54 TO ROW 59 RT INOPERATIVE. RESECURED EMERGENCY LIGHT CONNECTOR. OPS CK NORMAL.SDR UALA2010012500299Cable · inoperativeEMERGENCY LIGHT ROW 38 RT INOPERATIVE. REPLACED EMERGENCY LIGHT CABLE. OPS CHECK NORMAL.SDR UALA2010012500297Connector · disconnectedSEATS 7, 8, 9, 10, 11, 24, 25 AND 26 SEAT EMERGENCY LIGHTS INOP HAVE AOG NEW POWER BOXES AOG F2197 AND K2305. ALL LIGHTS OPS CHK OK EXCEPT SEATS 7 ABC AND 8 ABC. FOUND CONNECTOR UNDER SEAT TRACK COVER AT SEAT 8B DISCONNECTED. SEC'D CONNECTOR, ALL LIGHTS ANDSDR FDKA2010012500012Connector · dirtyEMERGENCY LIGHT AT 3A INOP. CLEANED AND RE-SECURED CONNECTORS.SDR DALA101389855Wire · brokenDURING LINE CHECK, MX FOUND THAT THE EMERGENCY PATHWAY LIGHTING AT ROW 4C IN THE FIRST CLASS CABIN WAS INOPERATIVE. MX FOUND A BROKEN WIRE AT THE CONNECTOR UNDER SEAT 4D. THE WIRE WAS RE-PINNED TO THE CONNECTOR AND THE SYS RETURNED TO NORMAL OPERATION.SDR DALA100969996Connector · disconnectedDURING LINE CHECK, MX FOUND THAT THE RT AFT RED EMERGENCY PATHWAY LIGHTING WAS INOPERATIVE. MX FOUND A CONNECTOR IN THE WIRE HARNESS UNPLUGGED, RECONNECTED IT, AND FUNCTIONALLY CHECKED THE SYS.SDR RAIA2010012400002Wire · brokenDURING THE PRE FLIGHT INSPECTION THE CREW REPORTED THAT THE FLOOR EMERGENCY LIGHT AS BEING INOPERATIVE. MAINTENANCE INSPECTED THE LIGHT AND FOUND A BROKEN WIRE. THE WIRE WAS REPAIRED AND THE LIGHTS OPS CHECKED GOOD.SDR MASA2010012400059Connector · looseHNL - REPORTED EMERGENCY EXIT PATH LIGHTING THAT FAILED TO ILLUMINATE. MX FOUND AND SECURED A LOOSE WIRING CONNECTION AT THE LIGHTING ASSEMBLY.SDR UALA2010012500291Connector · unsecureFLOOR EMERGENCY LIGHT STRIP UNPLUGGED LAST ROW OF ECONOMY CABIN. FOUND PLUG UNSECURE. SECURED EMERGENCY LIGHT STRIP PLUG, OPS TEST OK.
Back to JASC 3397