SDR AALA20090727SJU02Pin · looseSJU - FIRST CLASS EMERGENCY LIGHT INOPERATIVE. RE-LOCK PUSH OUT PIN AT SEAT 5E-F CONNECTOR. OPS CHECKED NORMAL WD 33-51-01.SDR AALA20090727SJU01Connector · looseSJU - EMERGENCY LIGHT FOR SEAT 36D INOPERATIVE. REINSTALLED LOOSE CONNECTOR AT 36F SIDEWALL.SDR AALA20090726LHR02Cable · chafedLHR - SEAT MOUNTED EMERGENCY LIGHTS IN AFT CABIN INOPERATIVE. REPAIRED SEAT TO SEAT CABLE AT ROWS 36-37 UNDER SSWD 20-10-13. OPS CHECKS OK.SDR RAIA2009072800003Connector · looseCREW REPORTED THE GALLEY BULKHEAD EMERGENCY EXIT SIGN AS BEING INOPERATIVE. MAINTENANCE RESET THE ELECTRICAL CONNECTOR GOING TO THE LIGHT ASSEMBLY AFTER WHICH THE EMERGENCY LIGHT OPERATED AS PER THE AMM PROCEDURES.SDR SWAA094802Wire · brokenDURING SCHEDULED 18Y CHECK, FOUND EMERGENCY EXIT LIGHT INOP IN COCKPIT. REPAIRED BROKEN WIRE PER WDM.SDR SWIA200922248Wire · looseFORWARD EMERGENCY LIGHT ON LEFT FLOOR LIGHT STRIP INOP. (FLT 7801) RE-SECURED CONNECTOR WIRES.SDR MASA2009072500227Connector · looseASH FLIGHT 2925 PHX - ICT. REPORTED THAT THE FLOOR LEVEL EMERGENCY ESCAPE PATH LIGHTING AFT OF ROW 8 WAS INOP. MX SECURED THE LIGHTING POWER SUPPLY CONNECTOR.SDR NWAA092609862Wire · brokenDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING FOR THE CATWALK IN THE TAIL COMPARTMENT WAS INOPERATIVE. MAINTENANCE REPLACED THE BATTERY PACK AND REPAIRED A BROKEN GROUND WIRE. THE LIGHTS RETURNED TO AN OPERATIONAL CONDITION.SDR SWIA200922240Wire · looseLAST FIVE FLOOR EMERGENCY LIGHTS INOP. (FLT 6292) RESECURED WIRES ON LIGHT STRIP CONNECTOR.SDR UALA2009072702218Feeder Cable · faultyEXIT PATH LIGHTING BETWEEN ROWS 31 AND 33 IS INOP. FOUND EEL STRIP UNPLUGGED AT ROW 31. ALSO FOUND EEL LIGHTING INOP BETWEEN ROWS 16 AND 21. REPLACED EEL FEEDER AT ROW 16, TESTS OKAY.SDR UALA2009072702217Connector · unsecureF/A REPORTS EEL LIGHTS ARE INOP FROM ROW 15 AFT. SECURED AND CLEANED EEL CONNECTOR IN AFT GALLEY FLOOR. ALL LIGHTS CHECKED OKAY.SDR FDKA2009072300159Connector · dirtyFRL FLT 6214 CVG. AFT CEILING EMERGENCY EXIT LOCATOR FORWARD SIDE LIGHT OUT. MX CLEANED AND RESECURED CONNECTOR. OPS GOOD.SDR SWIA200922176Wire · brokenFORWARD MOST RED EMERGENCY TRACK LIGHT INOP. (FLT 6236) REPAIRED WIRE.SDR AALA20090726SFO04Connector · brokenSFO - EMERGENCY EXIT LIGHT AT SEAT 32D INOPERATIVE. REMOVED AND REPLACED THE BROKEN PIN CONNECTOR. OPS CHECKED OK.SDR AALA20090726SFO03Connector · brokenSFO - SEAT 24D EMERGENCY EXIT LIGHT INOPERATIVE. REMOVED AND REPLACED THE BROKEN PIN CONNECTOR. OPS CHECKED NORMAL.SDR UALA2009072402201Connector · unsecureEMERGENCY LIGHT STRIP INOP AT RT MID LAV. RE-CONNECTED EMERGENCY LIGHT STRIP CONNECTOR. OPS CHECKED OK.SDR USAA20090727SB123Wire · exposedORD - MAINTENANCE REPORTED THE FOLLOWING EMERGENCY LIGHTS INOPERATIVE: PATH LIGHTS AT FORWARD CLOSET AND AT SEAT ROWS 3, 4 AND 5 AND THE EXIT SIGN ABOVE R1 SERVICE DOOR. MAINTENANCE FOUND WIRING TO SPLICE UNDER SEAT ROW 5ABC EXPOSED AND RUBBING ON FRAME AT BSDR USAA20090724BB118Wire · brokenPHL - WITH EMERGENCY EXIT LIGHTS SWITCH IN OFF POSITION, WITH POWER TURNED OFF, AFT INTERIOR EMERGENCY EXIT LIGHT ILLUMINATED. REPAIRED BROKEN WIRE BETWEEN F/A SEAT AND EXIT DOOR AT FLOOR LINE.SDR AALA20090724SFO02Pin · brokenSFO - EMERGENCY EXIT LIGHT ON SEAT 32D INOPERATIVE. REMOVED AND REPLACED BROKEN PIN CONNECTOR. OPS CHECK OK AS PER MM.SDR SWAA094746Wire · disconnectedDURING SCHEDULED MV1 CHECK, FOUND FWD EEPLS INOP. RECONNECTED WIRE TO LIGHT ASSY PER MM.SDR UALA2009072302185Connector · looseWALL EEL INOP AFT GALLEY LT AND FWD WALLS. SECURED EEL CONNECTION AT ASSY.SDR UALA2009072302184Feeder Cable · faultyEEL INOP ROWS 45-55 ABC & DOOR 4L FWD EEL EXIT SIGN. REPLACED FEEDER CABLE.SDR ABXA200907230035Connector · not seatedEMERGENCY EXIT LIGHT OVER R1 DOOR WILL NOT TEST. RESEATED ELECTRICAL CONNECTOR 9084. EMERGENCY EXIT LIGHT OPS CK GOOD.SDR SWIA200922190Connector · looseFORWARD FLOOR EMERGENCY LIGHTS INOP. (FLT 6586) RESECURED CONNECTOR.SDR RAIA2009072900001Wire · loosePRE FLT 8010 - STL - DURING PRE FLT INSPECTION, CREW REPORTED THAT THE EMERGENCY LIGHT OVER ROW 12 WAS INOPERATIVE. MAINTENANCE RESECURED A LOOSE WIRE TO THE LIGHT ASSEMBLY. OPERATIONAL CHECK OF THE LIGHTS AFTER THE REPAIR CHECKED GOOD.SDR SWAA094749Wire · disconnectedDURING SCHEDULED HC1 CHECK, FOUND EEPLS INOP AT ROW 1. RECONNECTED WIRE PER MM.SDR USAA2009072491904Wire · damagedFLT 75 - SEA - EEL - SEAT MOUNTED EMERGENCY PATHWAY LIGHTS AT ROW 26L INOPERATIVE. MAINTENANCE REPAIRED DAMAGED WIRES AT 26L EMERGENCY PATHWAY LIGHTS.SDR CHQA200900162Connector · looseDURING INSPECTION THE NR 2 & 3 FLOOR EMERGENCY LIGHT STRIPS WOULD NOT ILLUMINATE. THE CONNECTOR ON THE NR 3 INVERTER WAS RE-SECURED AND THE EMERGENCY LIGHTS OPERATED NORMALLY.SDR UALA2009072202162Connector · unsecureEMERGENCY EXIT LIGHT INOP. AT SEAT 35 LEFT. SECURED CONNECTOR. OPS. CKS. NORMAL.SDR USAA2009080492015Wire Harness · brokenLOGPAGE:8558629 - FLT 321 - LAS-ORD - EMERGENCY LIGHTS - FLOOR LEVEL RED EMERGENCY LIGHT AT ROW 8 LEFTHAND SIDE INOPERATIVE. FOUND WIRE BROKEN FROM CONNECTOR UNDER SEAT ASSEMBLY. COMPLIED WITH TEMPORARY REPAIR TO EMERGENCY LIGHT BROKEN WIRE. REINSPECTION WESDR DL76L091249Wire · brokenON DRC - PASSENGER SEAT 39F EMERGENCY ESCAPE PATH LIGHT OUT. FWD TO MCO AND PLACARD PER MEL M33-51-03A. FOUND WIRE UNDER SEAT BROKEN.SDR DL76G091248Connector · damagedON DAILY CHECK FOUND ESCAPE LIGHTS INOP AT SEATS 21B /32B /27F. REPLACED LIGHT SOCKET AT 21B. REPLACED CONNECTORS AT 32B AND 27F. OPN NORMAL.SDR SWIA200922174Connector · dirtyEMERGENCY EXIT LIGHT AND PORTION OF LIGHT STRIP INOP. (FLT 6439) CLEANED CONNECTOR.SDR USAA2009072291898Wire · brokenFLT 321 - LAS - ORD - EMERGENCY LIGHTS - FLOOR LEVEL RED EMERGENCY LIGHT AT ROW 8 LEFT SIDE INOPERATIVE. FOUND WIRE BROKEN FROM CONNECTOR UNDER SEAT ASSEMBLY. COMPLIED WITH TEMPORARY REPAIR TO EMERGENCY LIGHT BROKEN WIRE. REINSPECTION WEEKLY AND FINAL REPAISDR UALA2009072202161Connector · unsecureEMERGENCY LIGHTS ON FLOOR AT 1L DOOR, CLOSET, GALLEY COME ON FOR 90 SECONDS. RESEATED CONNECTOR ON POWER SUPPLIES M735 AND M1557 AND TESTED OKAY.SDR UALA2009072202160Connector · unsecureEMERGENCY LIGHTS NEAR FORWARD LAV CAME ON MOMENTARILY. RESEATED CONNECTOR ON POWER SUPPLIES M735 AND M1557 AND TESTED AND NOW OKAY.SDR UALA2009072102155Feeder Cable · disconnectedFLOOR EMERGENCY LIGHT STRIP INOP FROM ROW 3 THRU 10. FOUND FEEDER CABLE DISCONNECTED. RECONNECTED, LIGHT OP CHECKS OKAY.SDR C2XA09CL100Connector · looseDURING ROUTINE MAINTENANCE, THE LEFT OVERWING EMERGENCY LIGHT EXIT SIGN WAS INOPERATIVE. MAINTENANCE INSPECTED AND RESECURED THE EXIT SIGN CONNECTOR. OPERATIONAL CHECKS WERE GOOD.SDR FDKA2009072000156Connector · dirtyFRL 6222 CVG-DTW. CABIN EMERGENCY LIGHT BY GALLEY DOOR INOP. MX CLEANED CONNECTOR, OPS GOOD.SDR UALA2009072202169Wire Harness · inoperative2EA ADJACENT EMERGENCY LIGHTS ON SEAT 3F ARE INOPERATIVE. REPLACED LIGHT ASSY AND SECURED HARNESS. CHECKS GOOD.SDR SWIA200922167Wire · brokenFOUR FLOOR PROXIMITY EMERGENCY EXIT LIGHTS INOP. (FLT 6455) REPAIRED BROKEN WIRE.SDR AALA20090719LGA02Wire · damagedEXIT LIGHT BY FLOOR ACROSS FROM FORWARD LAVATORY INOPERATIVE. REPAIRED WIRE AT EXIT LIGHT BY FORWARD LAVATORY. OPS CHECK NORMAL.SDR UALA2009072002120Light · inoperativeFLOOR EEL LIGHTS FROM ROW 15 AFT INOP. CLEANED CONNECTIONS AT LIGHT STRIP IN AFT GALLEY, OPS CHECKS NORMAL NOW.SDR SWIA200922114Connector · not seatedEMERGENCY ESCAPE PATH MARKING LIGHT INOP. (FLT 6288) RESEATED CONNECTOR.SDR FDKA2009071700155Connector · looseFRL FLT 6201 SYR. GALLEY WALL EXIT LOCATOR WILL NOT ILLUMINATE. RESECURED LOOSE LIGHT CONNECTOR. OPS GOOD.SDR SWAA094617Wire · looseDURING SCHEDULED MV2 CHECK, FOUND EEPLS INOP BETWEEN ROW 1 TO ROW 4. SECURED WIRE PER MM.SDR UALA2009072002116Connector · disconnectedSEAT MOUNTED EMERGENCY LIGHT AT SEAT 24JK INOPERATIVE. FOUND LIGHT DISCONNECTED, SECURED CONNECTOR, OPS NORMAL.SDR FDKA2009071600154Connector · dirtyFRL FLT 6217 CVG. AFT CEILING EMERGENCY EXIT FORWARD SIDE LOCATOR OUT. MX CLEANED CONNECTORS AND RESET OPS GOOD.SDR UALA2009071602099Connector · looseEEL GUIDE STRIPS INTERMITTENT ROWS 23 TO 25H. SECURED CONNECTOR AT SEAT ROW 23HJK. OP CHECK OKAY.SDR RAIA2009071700005Connector · dirtyDURING PRE-FLIGHT INSPECTION, THE CREW REPORTED THAT THE EMERGENCY LIGHT IN THE GALLEY WAS INOPERATIVE. MAINTENANCE CLEANED THE CONNECTOR AT THE EMERGENCY LIGHT POWER SUPPLY. THE EMERGENCY LIGHTING SYSTEM OPS CHECKED GOOD AFTER REPAIR.
Back to JASC 3397