SDR C2XA08IA028Wire Harness · burnedMAF - FLIGHT 2179 THE CREW REPORTED AN ELECTRICAL BURNING ODOR AT ROW 6 AND 7. THE AIRCRAFT LANDED AT MAF WITHOUT INCIDENT WHERE CONTRACT MAINTENANCE INSPECTED THE AIRCRAFT AND PLACED THE SIDEWALL LIGHT AT ROW 6/7 ON MEL 33-20-00/1 CAT C CTL NR 137792, AND THSDR AMTA200800025Wire · brokenAFTER LANDING, FOUND EMERGENCY LIGHTS OVERHEAD CIRCUIT BREAKER (D-4) POPPED. WILL NOT RESET. FOUND BROKEN WIRE LEADING TO OVERWING EMERGENCY LIGHTS BATTERY POWER SUPPLY. REPAIRED IAW SWP EMERGENCY LIGHT. OPS CHECKS NORMAL. (K)SDR 2008UALA00333Feeder Cable · defectiveEEL LIGHTS FROM ROWS 32-34 ARE INOPERATIVE. REPLACED FEEDER.SDR SA08002Wire · shortedPHL - NUMEROUS SEAT MOUNTED EMERGENCY LIGHTS WERE FOUND INOPERATIVE. MAINTENANCE REPAIRED WIRE AT SEAT 20 LT, AND REPLACED EMERGENCY POWER SUPPLY UNIT, FIN 11WL. OPERATIONALLY CHECKS OK.SDR BB08004Wire · brokenMAD - MAINTENANCE REPORTED THE FLOOR PATH EMERGENCY LIGHTING AT SEAT 12F INOPERATIVE. MAINTENANCE SPLICED BROKEN WIRE. OPERATIONAL CHECK GOOD.SDR C2XA08ON069Connector · looseFLT MX - ONT - WHILE PERFORMING 2A CHECK INTERVAL INSPECTION MX FOUND CEILING PANEL EMERGENCY EXIT SIGN BETWEEN SEAT 1A AND GALLEY DOES NOT ILLUMINATE. MX FOUND CONNECTOR TO BE LOOSE AND RECONNECTED AND OPERATIONALLY CHECK SATISFACTORY. AIRCRAFT WAS RELEASEDSDR 2008UALA00311Connector · looseEMERGENCY EXIT EEL LIGHTS ARE INOP AT SEATS 2J FWD & AFT, 4F FWD & AFT, FROM ROW 55 THRU 59 LEFT, AT ROW 61 LEFT AND AT DOOR 5 LEFT AFT LOWER WALL CROSS AISLE. SECURED CONNECTOR.SDR AALA200800082Connector · looseLGA - EMERGENCY LIGHTS AT SEAT ROW 9 INOPERATIVE. SECURED LOOSE CONNECTOR FOR EMERGENCY LIGHT AT SEAT ROW 9. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR C2XA08IA026Wire · brokenIAH - DURING MAINTENANCE INSPECTION THE LAST THREE AISLE PATH LIGHTING STRIPS WERE FOUND TO BE INOPERATIVE. MAINTENANCE INSPECTED THE AIRCRAFT AND REPAIRED A BROKEN WIRE AT SP9221, OPERATIONALLY CHECKED WITH NO DEFECTS, AND THE AIRCRAFT WAS APPROVED FOR RETURSDR C2XA08TY012Wire · disconnectedTYS - DURING ROUTINE MX THE EMERGENCY FLOOR LIGHT STRIP BETWEEN ROWS 10 & 12 WAS FOUND INOP. MX RECONNECTED THE LIGHT STRIP WIRES AND THE OPS CHECK WAS GOOD. A/C WAS RELEASED FOR RETURN TO SERVICE.SDR SB08002Wire · brokenDFW - MAINTENANCE REPORTED THE ESCAPE PATH EMERGENCY LIGHTS AT SEAT ROWS 18, 19 AND 24 INOPERATIVE AND THE EMERGENCY EXIT LIGHT AT SEAT ROW 6 INOPERATIVE. MAINTENANCE REPAIRED A BROKEN WIRE 8 INCHES FROM LIGHT AT SEAT ROW 6 PER SWPWM 20-30-12, REPLACED A BROKSDR 2008UALA00288Connector · looseEMERGENCY LIGHTS FAIL TEST SHOW BATTERY AFT LEFT. LOOSE CONNECTOR. RESEATED CONNECTOR. LIGHTS TESTED NORMAL.SDR SWAA080343Connector · looseDURING SCHEDULED BRDG CHECK, FOUND EMERGENCY EXIT LIGHTS ILLUMINATED WITH SWITCH IN THE OFF POSITION. FOUND LOOSE CONNECTOR. SECURED CONNECTOR PER WDM.SDR 2008UALA00285Connector · looseEEL LIGHT AT 7C INOP. LOOSE CONNECTOR AT SEAT ROW 7. RESECURED LOOSE CONNECTOR, LIGHTS OPS NORMAL.SDR RAIA00801018Wire · loosePRE FLT 5597 - EMERGENCY LIGHTING INOPERATIVE. MAINTENANCE RESECURED WIRING TO THE FORWARD MOST LIGHTING STRIP. OPS CHECK GOOD.SDR 2008UALA00275Connector · disconnectedEXIT PATH LIGHTS 2E-12F. FOUND CONNECTOR UNPLUGGED. RESECURED.SDR TRBA2008006Wire · brokenEMERGENCY EXIT LIGHT BY SERVICE DOOR ON FLOOR INOP. REPAIRED BROKEN WIRES AT SERVICE DOOR EMERGENCY EXIT SIGN IAW SRM 20-27-14 PERFORMED OPT CHK FOUND WORKING PROPERLYAT THIS TIME IAW JIC 33-50-00.SDR AALA200800056Wire · damagedBOS - EMERGENCY LIGHT AT SEAT ROWS 20 TO AFT CABIN. REPAIRED WIRE FOR EMERGENCY LIGHT AT SEAT ROWS 20 TO AFT CABIN. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR 2008UALA00238Connector · looseSTAIR WELL CEILING EMERGENCY LIGHT BETWEEN MAIN DECK AND UPPER DECK & UPPER DECK CEILING EMERGENCY LIGHTS AT SEATS 13 & 17 ARE INOP. RESECURED CONNECTOR.SDR 2008UALA00233Feeder Cable · unsecureFIRST CLASS AND FWD X AISLE EEL LIGHTS INOP. SECURED CABLE.
SDR 2008UALA00232Connector · looseLEFT EEL INOP IN FIRST CLASS AT LAV. SECURED CONNECTOR.SDR AALA200800052Wire · brokenMIA - EMERGENCY LIGHT AT SEAT 32D INOPERATIVE. REPAIRED BROKEN WIRE FOR EMERGENCY LIGHT AT SEAT 32D. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR RAIA00801012Connector · loosePRE FLT 7949 - MKE - EMERGENCY LIGHT INOP. MAINTENANCE SECURED THE CONNECTOR TO THE LIGHT. OPS CHECKED GOOD.SDR RAIA00801013Connector · dirtyPRE FLT 5450 - STL - EMERGENCY LIGHTS TURN ON WHEN PUT IN ARMED MODE. MAINTENANCE REMOVED THE FLIGHT ATTENDANT LIGHTING PANEL AND CLEANED THE CONNECTION. OPS CHECKED GOOD.SDR 2008UALA00193Wire · brokenEEL WIRE BROKEN AT LAV 112 SIDE WALL.SDR SWAA080316Wire · looseEEPLS INOP AT ROW 2 ABC. FOUND LOOSE WIRE. SECURED WIRE PER WDM.SDR HNAA0800027Diode · inoperativeCABIN ROW 7, FLOOR EMERGENCY LIGHTS WERE FOUND INOPERATIVE. REPAIRED WIRING AND REPLACED CONNECTOR/DIODE AT CR4, OPERATIONAL CHECK GOOD.SDR 2008UALA00174Wire · looseLOOSE WIRE ATTACHED TO SMALL THIN PANEL FOUND LOOSE AT SEAT 28H. INSTALLED NEW EEL STRIP, OP CHECK OK.SDR 2008UALA00166Connector · unsecureWALL EEL INOP: RIGHT SIDE WALL AFT GALLEY. SECURED CONNECTOR.SDR 2008UALA00165Connector · disconnectedSEAT EELS INOP: 4E & 5E BOTH SECTIONS. SECURED CONNECTOR.
SDR AALA200800047Connector · disconnectedDFW - EMERGENCY LIGHT AT SEAT 19D INOPERATIVE. SECURED CONNECTOR FOR EMERGENCY LIGHT AT SEAT 19D. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR NWAA080479866Connector · corrodedDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN THE TAILCONE CATWALK WAS INOPERATIVE. MAINTENANCE FOUND THE COMPARTMENT FLOODLIGHTS CONNECTORS WERE CORRODED AND REPLACED THEM. THE LIGHTS WERE OPERATIONALLY CHECKED AND THE AIRCRAFTSDR FDKA200801014Connector · dirtyFDM 6033 JFK (0630 PHX LCL) - EMERGENCY LIGHT PANEL NOT ILLUMINATING. MX CLEANED AND REPAIRED CONNECTOR. OPS GOOD.SDR MASA200800017Connector · looseASH 2773 PHX - AFT EMERGENCY FLOOR LIGHTS 40% INOP. MX RESECURED CONNECTOR TO FLOOR LIGHTS.SDR SWIA200819041Feeder Cable · brokenFLT 3937 - LAST SECTION OF EMERGENCY LIGHTING IS INOP. REPLACED EMERGENCY LIGHT CONNECTOR CABLE. OPS CHECK GOOD.SDR RAIA00801008Connector · loosePRE FLT NR 5527-STL-EMERGENCY LIGHT AT MID CABIN LOCATION INOPERATIVE. MAINTENANCE RESECURED THE FIXTURE CONNECTION. SYSTEM OPS CHECKED GOOD.SDR BB08001Wire Harness · brokenPHX - ROW 19L EMERGENCY LIGHT INOP. MAINTENANCE REMOVED & REPLACED WIRE HARNESS & EMERGENCY LIGHT ON ROW 19L. OPS CHECKS GOOD.SDR FDKA200801007Connector · looseFDM 6088 MCO - EMERGENCY LIGHT SIGN OUT AT GALLEY. MX RESECURED LOOSE CONNECTOR. OPS CK GOOD.SDR AMTA200800010Wire · shortedEMERGENCY LIGHT PATHWAY LIGHT AT FWD GALLEY AND RT FWD CABIN INOPERATIVE. DRIED OUT WET WIRES AND PLUGS BY A2 LAVATORY. OPS CHECK GOOD. (K)SDR TRAX200800056Wire · damagedLEFT AFT MOST EXTERNAL EMERGENCY LIGHT INOP. EXTERIOR EMERGENCY LIGHTS - ONE OF TWO REARWARD ON EACH SIDE. FOUND WIRE (BETWEEN LIGHT AND TB107) BROKEN. REPAIRED WIRE IAW CRJ 200 ELECTRICAL/ELECTRONICS STANDARD PRACTICES MANUAL. OPS CK GOOD.SDR C2XA08ON063Connector · looseONT OVERNIGHT MX - WHILE PERFORMING OPERATIONAL CHECK ON EMERGENCY LIGHTING SYSTEM MX FOUND EMERGENCY EXIT LIGHTS WILL NOT ILLUMINATE FROM 8ABC TO 14ABC INCLUDING EXIT HATCH LIGHTING. MX PERSONNEL FOUND CONNECTOR LOOSE AND RE-TIGHTEN CONNECTOR AT SEAT 12A BATSDR 2008UALA00117Connector · brokenL2 DOOR EXIT SIGN FWD OF DOOR HAS A BROKEN CONNECTOR. REPLACED CONNECTOR.SDR SWAA080158Connector · brokenDURING SCHEDULED BRDG CHECK, FOUND RT OVERWING EMERGENCY EXIT LIGHT CONNECTOR BROKEN. REPAIRED CONNECTOR PER MM.SDR 2008UALA00104Connector · disconnectedEEL FLOOR LIGHT STRIP INOP AT SEAT ROW 11. RESECURED CONNECTOR.SDR NSVA20070252Socket · inoperativeSMOKE ODOR IN CABIN, LIGHT BULB AT SEAT 10F CHATTERED AND CAUSED SOCKET TO BURN OUT. TROUBLESHOT SMOKE ODOR TO CHATTERING LIGHT BULB. REMOVED LIGHT BULB. DEFERRED IAW MEL 33-20-01-01 CAT C. ID 28794SDR 2008UALA00066Wire · brokenL1 DOOR LWR EMERGENCY EXIT IDENTIFIER SIGN L979 WIRES ARE BROKEN.SDR 2008UALA00002Wire · chafedEMERGENCY LIGHT TEST FAILS 3 SVC CK. FOUND WIRES CHAFED UNDER SEAT 4ABC. REPAIRED WIRES AT 4ABC, TESTS ALL NORMAL.SDR 2008UALA0002Wire · chafedEMERGENCY LIGHT TEST FAILS 3 SERVICE CHECK.SDR DL76S080149Wire · damagedEMERGENCY LIGHT INOP AT SEAT 14F AND 10F. REPAIRED WIRES, OPS CK OK.SDR FDKA200801001Connector · unsecureFDM 6137 DAY (0743 PHX LCL) - EMERGENCY FLOOR PROX LIGHTS OUT BETWEEN ROW 3 TO 7. MX RESECURED CONNECTOR ON FLOOR PROX LIGHT AT ROW 7.