JASC 3397
Service difficulty reports · 22,670
Reports filed under 3397 · Light System Wiring, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3397' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3397' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DLM90060051Wire · brokenFLOOR EMERGENCY LIGHTS INOP ROW 10 -13 CDE. FOUND BROKEN WIRE. RESPLICED, CHECKS NORMAL NOW.SDR CHQA200600008Wire · chafedTHREE CABIN EMERGENCY LIGHT PROXIMITY STRIPS CHAFED TO THE WIRE. REMOVED AND REPLACED THREE CABIN EMERGENCY LIGHT PROXIMITY STRIPS IAW EMB 145 MM 33-50-12. OPS CHECK GOOD AT THIS TIME.SDR SWIA200616140Wire · looseONE WHITE EMERG FLOOR LIGHT INOP ON FLOOR STRIP. RESECURED WIRING ON FLOOR STRIP. OPERATIONAL CHECK GOOD.SDR RAIA00601015Wire · unsecurePREFLIGHT 5461-STL- EMERGENCY LIGHT FORWARD STRIP INOP. MAINTENANCE RESECURED WIRING TO FORWARD EMERGENCY LIGHT STRIP.SDR AALA20060021Connector · looseMIA - EMERGENCY LIGHTS FROM SEATS 6G TO 18G AND SEAT 23G INOPERATIVE. SECURED CONNECTION AT SEATS 6G TO 18G AND RESECURED PLUG 23G. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR COMA0560809Wire · looseFLIGHT 5751 - AFT SECTION OF EMERGENCY FLOOR LIGHTS ARE INOPERABLE. SECURED LOOSE CONNECTOR WIRE. SYSTEM TEST NORMAL.SDR ASOA06085Switch · brokenDURING A GROUND INSPECTION, THE EMERGENCY LIGHTS REMAINED ON WHEN IN THE ARMED POSITION. MAINTENANCE REMOVED AND REPLACED THE EMERGENCY EXIT LIGHT TOGGLE SWITCH. MAINTENANCE REMOVED AND REPLACED THE EMERGENCY EXIT LIGHT TOGGLE SWITCH. OPERATIONAL CHECKS GOOSDR SIMA200601601Wire · brokenDURING PREFLIGHT, FOUND EMERGENCY EXIT LIGHT AT SEAT 8C INOPERATIVE. REPAIRED BROKEN WIRE AT EMERGENCY EXIT SIGN. OPERATIONAL CHECK GOOD. AIRCRAFT RETURNED TO SERVICE. (K)SDR SWAA060116Wire · brokenDURING SCHEDULED RON CHECK, FOUND LT OVERWING EMERGENCY EXIT LIGHT INOP. FOUND WIRE NR W1460-509-20 BROKEN BETWEEN CONNECTORS NR D2976 AND D10714. REMOVED AND REPLACED BROKEN WIRE AND LIGHT ASSY PER WDM AND MM.SDR SA06004Connector · looseRIC - MAINTENANCE REPORTED THE LOW LEVEL EMERGENCY LIGHTS AT ROW 23 INOPERATIVE. MAINTENANCE RESEATED THE QUICK-DISCONNECT PLUG BENEATH THE SEAT. OPERATIONAL CHECK GOOD.SDR BB06002Connector · looseEMERGENCY ESCAPE PATH LIGHTING INOPERATIVE FROM SEAT ROWS 19AB THROUGH 24AB. RESECURED WIRING CONNECTOR AT SEAT 24AB. NO FURTHER FAULTS.SDR SDR2006004Socket · burnedBURNED ODOR IN MID SECTION OF THE CABIN. NO FIRE OR SMOKE EVIDENCE NOTED HOWEVER, FOUND A LIGHT SOCKET BURNED OUT. REPLACED LIGHT SOCKET. (K)SDR AALA20060017Wire · brokenMIA - EMERGENCY PATH LIGHTS IN FORWARD FIRST CLASS GALLEY INOPERATIVE. FOUND BROKEN LINE AT LIGHT ASSEMBLY. REPLACED LIGHT ASSEMBLY. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR COMA0560802Wire · brokenFLIGHT 5233 - EMERGENCY LIGHT AT EXIT DOOR IS INOPERABLE. REPAIRED BROKEN WIRE AT LIGHT.SDR WX0600006Wire · disconnectedCREW REPORTED EMERGENCY LIGHTS NOT WORKING FORWARD OF THE FIRST ROW. MAINTENANCE RECONNECTED EMERGENCY LIGHTS AND OPERATIONALLY CHECKED GOOD IAW MM 33-41-02. AIRCRAFT RETURNED TO SERVICE.SDR AALA20060012Connector · looseJFK - EMERGENCY LIGHT AT 36C INOPERATIVE. FOUND LOOSE CONNECTOR. RESECURED CONNECTOR FOR EMERGENCY LIGHT AT 36C. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR DXTA200601185Rheostat · burnedDURING ENGINE START OF THE NR 2 ENGINE A STRONG ELECTRICAL ODOR WAS SMELLED BY THE CREW AT 38 PERCENT N2. AN ELECTRICAL ARC CLOSE TO LEFT KNEE, WENT TO IDLE CUTOFF ON THE NR 2 ENGINE AND SHUT THE BATTERY SWITCH OFF, LOTS OF SMOKE AND ODOR IN COCKPIT. T/S FOUSDR AALA20060011Connector · disconnectedCDG - EMERGENCY ESCAPE PATH LIGHTS BETWEEN 28AB AND 36AB INOPERATIVE. FOUND CONNECTOR AT 37AB DISCONNECTED. RECONNECTED CONNECTOR AT 37AB FOR EMERGENCY ESCAPE PATH LIGHTS BETWEEN 28AB AND 36AB. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AMTA200600015Wire · disconnectedFLOOR PATH LIGHTING INOPERATIVE ROW 26 TO R3 EXIT. RECONNECTED PATH LIGHT AT ROW 26. OPS CHECK GOOD. (K)SDR AWXA200600390Wire Harness · damagedMCN - EEL - DURING C34 CHECK, DISCOVERED ESCAPE PATH WIRING HARNESS WITH MULTIPLE DAMAGED CONNECTORS FROM BS 344 TO BS 947 AT WL 208. MAINTENANCE REPAIRED THE ESCAPE PATH WIRING HARNESS IAW BOEING 737-300 SWPM 20-30-12 STEP 14C. OPERATIONAL CHECKS WERE GOOD SDR RAIA00601009Wire · brokenPOST FLIGHT 5542 - DSM - FLOOR ESCAPE PATH EMERGENCY LIGHT INOP. MAINTENANCE INSPECTED AND REPAIRED BROKEN WIRE TO CONNECTOR.SDR MASA200600009Diode · failedFLOOR PROX ILLUMINATION EMERGENCY ESCAPE PATH LIGHTING INOP. MAINTENANCE REMOVED AND REPLACED FLOOR DIODE.SDR C2XA06CLOO2Wire · brokenMKE FLIGHT NR 3009, THE CREW REPORTED A STRONG ELECTRICAL ODOR COMING FROM BREAKER BOX BEHIND CAPTAINS SEAT WHILE TAXING INTO GATE. THE TAXI LIGHT CAME ON, FLICKERED, THEN WENT OUT WITHOUT SWITCH BEING TURNED ON. MAINTENANCE INSPECTED AND RELEASED AIRCRAFT ISDR SWIA200616083Connector · dirtySEGMENT OF EMERGENCY EXIT LIGHTS FAIL TEST. CLEANED CONNECTOR FOR CENTER EMERGENCY LIGHTS BATTERY PACK, OPERATIONAL CHECK GOOD.SDR WX0600004Connector · brokenMAINTENANCE FOUND THE EMERGENCY LIGHTS INOPERATIVE AT 21D THROUGH 24D ON THE FLOOR. MAINTENANCE REPLACED THE BROKEN CRIMP ON THE CONNECTOR IAW MM 33-53-00. OPERATIONAL CHECK GOOD. AIRCRAFT RETURNED TO SERVICESDR C2XA06CLOO1Wire · brokenDURING ROUTINE MAINTENANCE THE PASSENGER ENTRANCE DOOR EMERGENCY LIGHT WAS INOPERATIVE. MAINTENANCE INSPECTED AND REPAIRED THE PASSENGER DOOR EMERGENCY LIGHT WIRE. OPERATIONAL CHECKS WERE GOOD.SDR RAIA00601005Wire · out of adjustPOST FLIGHT 5476, LT OVERWING EMERGENCY LIGHT DOES NOT ILLUMINATE. MAINTENANCE ADJUSTED WIRING ON LT OVERWING EMERGENCY LIGHT.SDR MASA200600002Connector · damagedEMERGENCY FLOOR LIGHTS ROW 1 INOP. MAINTENANCE REMOVED AND REPLACED CONNECTOR.SDR DL777050841Connector · burnedFOUND CONNECTOR ABOVE L1 DOOR BURNT AND MELTED. REPAIRED SAME.SDR AALA20050847Contact · dirtyRDU - OVERHEAD EMERGENCY LIGHTS AT ROW 29 INOPERATIVE. CLEANED CONTACTS ON EMERGENCY LIGHT BATTERY PACKS FOR OVERHEAD EMERGENY LIGHTS AT ROW 29. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AT0600001Connector · looseROW 12 EMERGENCY AISLE LIGHT IS OUT. REPAIR LOOSE CONNECTOR, OPS CHECK GOOD IAW MM 33-51.SDR AWXA200501617Wire · brokenPHX - EEL - DURING OVERNIGHT INSPECTION DISCOVERED ROW 13 LT SEAT EMERGERNCY PATH LIGHT OUT. MAINTENANCE REPAIRED BROKEN WIRE AT ROW 13. OPERATIONAL CHECKS WERE GOOD.SDR KC82006F00000Wire · arcedPILOT REPORTED SMOKE IN THE COCKPIT. HE TURNED OF THE GLARESHIELD LIGHTING AND THE SMOKE STOPPED. FOUND GLARESHIELD FLORESCENT TUBE LEAD WIRES ARCING TO GROUND. REPLACED FLORESCENT TUBE WITH NEW FLORESCENT TUBE AND INSULTED LEAD WIRE ENDS. OPERATIONAL CHECSDR 2005UALA01506Cable · inoperativePASSENGER SEAT 4F FWD EEL LIGHT INOP. REPLACED Y SPLITTER CABLE.SDR BB05108Wire · brokenFLOOR LEVEL EMERGENCY LIGHTS AFT CABIN RIGHT SIDE NEAR GALLEY FOUND INOPERATIVE. REPAIRED BROKEN WIRE AT TRACK LIGHT ASSEMBLY. NO FURTHER DIFFICULTIES.SDR ASOA051158Connector · disconnectedFLT 4578 - DURING A HANGAR INSPECTION IN BTR, THE FORWARD MOST EMERGENCY FLOOR LIGHT STRIP WAS FOUND TO BE INOPERATIVE. MAINTENANCE RECONNECTED THE FORWARD MOST EMERGENCY FLOOR LIGHT STRIP. OPERATIONAL CHECKS GOOD. AIRCRAFT OK FOR SERVICE. (M)SDR ASOA051151Wire · damagedDURING A GROUND INSPECTION IN SLC, THE EMERGENCY EXIT SIGN, DS158, WAS FOUND TO BE INOPERATIVE. MAINTENANCE FOUND AND REPAIRED DAMAGED WIRING AT CANNON PLUG P341. OPERATIONAL CHECKS GOOD. AIRCRAFT OK FOR SERVICE. (M)SDR RAIA00512025Connector · looseMX - STL - FLOOR EMERGENCY EXIT STRIP LIGHT AT OVERWING EMERGENCY EXIT INOP. MAINTENANCE RE-SECURED ELECTRICAL CONNECTOR TO FLOOR STRIP.SDR AALA20060132Connector · inoperativeAFW - LEFT HAND NUMBER THREE DOOR (STATION 1522) EMERGENCY ESCAPE LIGHT INOPERATIVE. REPLACED EMERGENCY ESCAPE LIGHT SQUIBB CONNECTOR AT LEFT NUMBER THREE DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR MASA200501071Wire · disconnectedROW 9 FLOOR EXIT LIGHT INOP. MX RECONNECTED WIRE.SDR RAIA00512042Connector · loosePRE FLIGHT 5415 - STL - ESCAPE PATH LIGHTING INOP. MAINTENANCE RESECURED LOOSE CONNECTION AT LIGHT STRIP.SDR CA060104000Wire · burnedFLT 5046 CLT-RTF, WHEN THE FO’S SIDE FLOOD LIGHT WIRING CAUGHT FIRE. A/C LANDED WITHOUT INCIDENT AND THE CREW HAD EXTINGUISHED FIRE IN APPROX 4 SECONDS PER THE CAPTAIN. A/C IMPOUNDED BY NTSB AND WAS RELEASED BACK TO MX UPON OUR RECEIPT OF DIGITAL PICTURES OFSDR AMTA200501206Wire · disconnectedEMERGENCY FLOOR TRACK LIGHTING FROM ROW 25 TO RT AFT LAV, INOPERATIVE. RECONNECTED WIRES TO LIGHT ASSY AT ROW 25. OPS CHECK GOOD. (K)SDR SWIA200516039Wire · brokenLAST THREE EMERGENCY LIGHTS OUT. REPAIRED BROKEN WIRE UNDER FLOORBOARD AT SEAT 9A, OPERATIONAL CHECK GOOD.SDR CA051222006Resistor · overheatedWHILE CARRYING OUT COMPANY CAMPAIGN 681-33-21-018, RESISTOR R145 FOR FLUORESCENT LIGHT CIRCUIT FOUND SHOWING SIGNS OF OVERHEATING. SYSTEM DISABLED AND DEFERRED.SDR MASA200501063Wire · fireF/O'S SIDE FLOOD LIGHT WIRING FIRE. MAINTENANCE REMOVED AND REPLACED FLOOD LIGHT ASSEMBLY, OPS CHECKED GOOD.SDR AALA20050837Connector · looseBOS - EMERGENCY ESCAPE PATH LIGHT AT SEAT 4G INOPERATIVE. FOUND LOOSE CONNECTOR ON SEAT 4G. RESECURED CONNECTOR ON SEAT 4G. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR SWIA200516040Wire · broken1 OF 5 LIGHT BULBS INOP ON FLOOR LEVEL EMERGENCY FLOOD LIGHT. REPAIRED WIRING TO SECTION OF INOP LIGHTS. OPERATIONAL CHECK GOOD.SDR RAIA00512038Connector · disconnectedPRE FLIGHT 5408 - STL - EMERGENCY TRACK LIGHTING INOP. MAINTENANCE INSPECTED AND FOUND CONNECTOR UNPLUGGED. RECONNECTED AND LIGHTS OPS CHECKED NORMAL.SDR RAIA00512035Connector · loosePRE FLT 5396 - STL - ESCAPE PATH LIGHTING IN FRONT OF CABIN INOP. MAINTENANCE RESECURED LOOSE CONNECTORS.
Back to JASC 3397