SDR CALA2024052001519Connector · disconnectedEMERGANCY LIGHT ON OVERHEAD BIN AT ROW 23 DEF INOP RELAMPED ASSY IRW 737 AMM 33-51-03, OPS CHECK FAILED. MEL PLCARD APPLIED REQUESTED. TOMC APPROVED. PLEASE UPDATE WITH PARTS/TIME NEEDED IF UNABLE TO FIX. FOUND PLUG UNCONNECTED ABOVE STOWBIN AT SEAT 23 RIGHTSDR DALA2024051705302Connector · unsecureSHIP 3149 MAIN AISLE OVERHEAD EXIT LIGHT INOP. CORRECTIVE ACTION: RESECURED LIGHT ASSY CONNECTION PER A319 AMM 33-51-13. AC OK FOR SERVICE. (5249532)SDR FDEA202405150671Wire · brokenWHEN SELECTING EMERGENCY LTS SWITCH ON OVERHEAD TO ON, COCKPIT OVERHEAD LT DOES NOT ILLUMINATE. ALL OTHERS OPERATE NORMALLY. PER WDM 33-51-21 FOUND GOOD GROUND BITWEEN GD602 AND G TERMINAL OF RESISTER R10381 AND DISCOVERED THAT WIRE WAS BROKEN FROM RESISTESDR SIMA20240610002Terminal · damagedR/H SERVICE DOOR EMERGENCY EXIT LIGHT NEXT TO FLOOR INOP. COMPLETE:RAR TERMINAL ENDS ON R/H SERVICE DOOR EMERGENCY LIGHT NEXT TO FLOOR IAW EMB 170 SWPM 20-41-10. OCK GOOD.EASI# 102.SDR SWAA2024052984871Wire · tornFWD LAV EMERGENCY EXIT INDICATOR LIGHT WIRE TORN. INVESTIGATION SHOWED GROUND WIRE W4142-0152-20 FOR EMERGENCY LIGHT L1187 PULLED OUT OF GD3782-DC. REPAIRED WIRE PER SWPM 20-90-15 AND WDM 33-51-21. FUNCTIONAL CHECK OF EMERGENCY LIGHTS TO BE PERFORMED ON CCNSDR DXTA2024051311758Wire · detachedFLOOR EMERG EXIT LIGHT: EMERGENCY FLOOR LIGHT IN THE LAVATORY IS INOPERATIVE. APPEARS AS THOUGH THE CONNECTOR HAS DISCONNECTED. ARRIVED AT AIRCRAFT AND VERIFIED FAULT. REMOVED LAV FRONT FACIA AND FOUND WIRES PULLED OUT OF CONNECTOR. RESECURED PINS IN CONNECSDR DALA2024051505247Ground Wire · loose11D EMERGENCY LIGHTS NOT WORKING. OK TO DEFER THE EMERGENCY LIGHT ON THE SEAT TRIM OF LLD TO A320 MEL 33-50-03A, MEL AND PLACARD INSTALLED. NO "M" PROCEDURES TO C /W. MCC NOTIFIED. FOUND POWER & GROUND WIRES GOING INTO LIGHT DISCONNECTED & LOOSE . RESECURED PSDR DALA2024051305140Wire · damagedSHIP 3301 EMERGENCY ESCAPE PATH MARKING ON SEAT 33AB INOP. CORRECTIVE ACTION: REPLACED LIGHT ASSY AND REPAIRED WIRING. (9606249)SDR DALA2024051405165Connector · damagedSHIP 3273 DISC: PASSENGER SEAT 17D ESCAPE PATH LIGHT CONNECTOR DAMAGED. C/A: FWD TO MCO PER MEL 33-50-03A. NO "M" PROCEDURES. PLACARD INSTALLED. (LP: 5490511)SDR AALA202405139164Wire · brokenAIRCRAFT WAS NOT GROUNDED: ROWS 11,12,13 ABC SEAT EMERGENCY AISLE LIGHTS INOPERATIVE. REPLACED DECODER/ENCODER UNIT (AALA202405133513), EMERGENCY POWER SUPPLY UNIT (AALA202405131064), EMERGENCY SUPPLY POWER UNIT BATTERY (AALA202405130019), AND REPAIRED BROKEN SDR DALA2024050905061Wire · damagedSHIP 3324 L3 EMERGENCY LIGHT FOUND INOP. CORRECTIVE ACTION: REPAIRED WIRING. OK FOR SERVICE. (4967847)SDR 3J7R2024050900001Wire Splice · looseEMERGENCY LIGHTS FLASHING ON AND OFF AT FORWARD RIGHT OVERWING POSITION AND FLOOR LEVEL EMERGENCY EXIT DIVAN POSITIONS. AFTER CHARGING FOR ONE HOUR BOTH LIGHTS HAVE FAILED ENTIRELY.SDR DALA2024051005093Wire · detached(LOG 5859053) ON SVC CHECK FOUND EMERGENCY LIGHT OUT ON "37 DELTA" SEAT. FOUND A WIRE CAME OUT FROM CONNECTOR. WIRE CRIMPED AND INSERTED TO CONNECTOR. OPS CK NORMAL. PERFORMED PER B737 AMM 33-51 AND WDM 33-51-14.SDR SWAA2024050883133Connector · out of adjustL/R OWE SLIDE LIGHT INOP ***CORRECTION TO TITLE*** L/H OWE SLIDE LIGHT INOP<[01] RECONNECTED LEFT FWD ESCAPE SLIDE LIGHT CONNECTOR AND PERFORMED GOOD FUNCTIONAL TEST PER AMM 33-51-04-960-801 STEP D (4).;[02] RELAMP L/R OWE SLIDE LIGHT AND PERFORMED GOOD FUNCTISDR AALA202405174342Wire Harness · no testAIRCRAFT WAS NOT GROUNDED: MAINTENANCE FOUND THE EMERGENCY LIGHT AT SEAT 2AC BURNT OUT WHILE ACCCOMPLISHING AN OPERATIONAL CHECK OF THE EMERGENCY LIGHTING SYSTEM. **ORIGINAL REPORT WAS AALA202405100360: MAINTENANCE REPLACED THE EMERGENCY PATHWAY SEAT LIGHT ON SDR AALA202405072884Connector · looseAIRCRAFT WAS NOT GROUNDED: EMERGENCY EXIT PATH LIGHTING ON ROW 24 ABC INOPERATIVE. FOUND LOOSE CONNECTOR ON SEAT, SECURED CONNECTOR OF EMERGENCY EXIT LIGHT 24ABC PER AMM 33-51-19.SDR AALA202405072046Connector · disconnectedAIRCRAFT WAS GROUNDED: EMERGENCY PATH LIGHTS AT SEAT 1H TO 5 H IS NOT WORKING INOP. MAINTENANCE OUND DISCONNECTED CONNECTOR D9574 AT SEAT 5H SECURED CONNECTOR PERFORMED EMERGENCY LIGHT OPS CHECK I.A.W AMM 33-51-00.SDR AALA202405078229Feeder Cable · cutAIRCRAFT WAS NOT GROUNDED: IN SEAT EMERGENCY LIGHT 13C INOP. FOUND CABLES AT LIGHT CONNECTOR CUT. REPLACED MALE CONTACTS IAW ESPM 20-48-31. LIGHT FULLY OPERATIONAL AND OK FOR SERVICE.SDR AALA202405076848Wire · brokenAIRCRAFT WAS NOT GROUNDED: ROW 22 EMERGENCY LIGHT INOPERATIVE FOUND WIRE LEADING TO LED LIGHT BROKEN. REPAIRED WIRE IN REFERENCE TO ESPM 20-53-33.SDR DALA2024050604940Connector · unsecureSHIP 3361 SEATS 38H, 41H, AND 43B RED) FLOOR PROXMITY EMERGENCY LIGHTS INOP. CORRECTIVE ACTION: RE-SECURED CONNECTORS PER A330 AMM 33-52. OK FOR SERVICE. (5267354)SDR DALA2024050604939Wire · damagedSHIP 3414 44HJ EEPLS CLEAR LIGHT INOP. CORRECTIVE ACTION: REPAIRED WIRE CONNECTOR PER A330 AMM 33-52. OK FOR SERVICE. (5867052)SDR DXTA2024050611675Connector · damagedLAV EMERG LIGHT: LAV SEAT 9 AISLE EMERGENCY LIGHT INOP. DOES WORK WITH REGULAR INTERIOR LIGHTING BUT NOT WITH EMER LIGHTS. REMOVED DEFECTIVE CONTACT PIN AND INSTALLED NEW CONTACT PIN IAW AMM 20-00-00 OPS CHECK GOOD AT THIS TIME.SDR DALA2024050304904Wire · disconnectedSHIP 3357 EEPL WHITE LIGHTS INOP AT POS 39AB, 35JH, 36JH AND 37JH. CORRECTIVE ACTION: RECONNECTED WIRES AT SEATS 35JH AND 37JH AND OPS CHK GOOD. 36JH AND 39AB. (5681797)SDR DALA2024050304903Connector · looseSHIP 3308 ESCAPE PATH (AFT) LIGHT INOP AT SEAT 3J. CORRECTIVE ACTION: FOUND CONNECTION LOOSE AT PLUG. RESECURED CK'S GOOD. (4760674)SDR AALA202405021635Wire · brokenAIRCRAFT WAS NOT GROUNDED: EMERGENCY LIGHT INOPERATIVE UNDER SEAT 7 AND 17. INSPECTED AND FOUND BROKEN SPLICES AT BOTH SEATS, REMOVED AND REPLACED BROKEN SPLICES AT SEAT 7 AND 17 (AALA202405024687).SDR AALA202405024687Wire · brokenAIRCRAFT WAS NOT GROUNDED: EMERGENCY LIGHT INOPERATIVE UNDER SEAT 7 AND 17. INSPECTED AND FOUND BROKEN SPLICES AT BOTH SEATS, REMOVED AND REPLACED BROKEN SPLICES AT SEAT 7 (AALA202405021635) AND 17.SDR AALA202405070752Wire · inoperativeAIRCRAFT IN BASE MAINTENANCE: INOPERATIVE EMERGENCY LIGHTS ON SEAT ROWS 11,12, AND 13 LEFT-HAND SIDE AT PASSENGER CABIN. ACCOMPLISHED WIRING MODIFICATION FOR EMERGENCY LIGHTING PER ENGINEERING AUTHORIZATION NUMBER 354020 AND PERFORMED CHECK OF THE CABIN LIGHT SDR DALA2024050604935Wire · damagedSHIP 3318 EMERGENCY LIGHT AT SEAT 36JH INOP. CORRECTIVE ACTION: REPAIRED WIRING PER A330 AMM 33-51. OK FOR SERVICE. (5950231)SDR DALA2024050304908Wire · shortedSHIP 195 DURING SERVICE CHECK FOUND EMERGENCY ESCAPE PATH LIGHTS INOP, FROM ROW 33 TO ROW 43, LEFT SIDE. CORRECTIVE ACTION: T/S PER WDM 33-51, FOUND WIRE SHORTED @ SEAT 42B, REPAIRED CONNECTOR, AND R&R POWER SUPPLY ASSY M90089, REF AMM 33-51, AND REPLACED BATTSDR CALA2024050301308Wire · exposedCLEANERS REPORT EXPOSED WIRES ROW 14BA. (LEFT HAND SIDE) WERE STILL NOT WORKING. UNABLE TO FURTHER TROUBLESHOOT DUE TO LACK OF TIME. FOUND EXPOSED WIRE TO BE BROKEN AND FOR THE EMERGENCY SEAT UNABLE TO READ OR RETREAVE SEVERED WIRE NUMBER (RED WIRE 22 LIGHTS. SDR AALA202405019376Wire Harness · unsecureAIRCRAFT WAS GROUNDED: SEAT 13C EMERGENCY LIGHTING HARNESS HANGING DOWN FROM SEAT HOUSING EXPOSED TO PASSENGER FOOT AREA. RE-SECURED EMERGENCY LIGHTING ELECTRICAL HARNESS AT 13C. OPERATIONAL CHECK OF EMERGENCY LIGHTING NORMAL AT TIME OF INSPECTION.SDR AALA202405019557Wire Harness · unsecureAIRCRAFT WAS GROUNDED: 29C EMERGENCY LIGHT HARNESS HAVING DOWN OUT OF SEAT HOUSING. RE-SECURED EMERGENCY LIGHTING HARNESS AT 29D, CHECK EMERGENCY LIGHTING NORMAL.SDR JJBA20240502068Connector · disconnectedFOUND MULTIPLE EMERGENCY LIGHTS INOPERATIVE. FOUND CONNECTOR DISCONNECTED, RE-CONNECTED CONNECTOR. OPS CHECK SATSDR AALA202404294504Ground Wire · brokenAIRCRAFT WAS NOT GROUNDED: EMERGENCY LIGHT AT SEAT 11C INOP. FOUND GROUND WIRE WH15NVR1 BROKEN IAW AWM 33-51-06. SPLICED GROUND WIRE IAW ESPM 20-43-11. OPS CHECK GOOD.SDR DALA2024050104845Connector · damaged(LOG 5738053) 30D EMERGENCY EXIT AISLE LIGHT INOP. FOUND WALL SIDE MOLEX CONNECTOR PIN LOOSE. SECURED IT AND CHECKED NML PER B737 WDM 33-51.SDR SWAA2024043079875Circuit Breaker · trippedFOUND RT AFT EMER LTS CB OUT. RESET W/CHRIS IN MX CONTROL 146124. EMER LTS OPERATE NORMALLY. INFO ONLY<[01] NOTED BY MXSDR DXTA2024042911616Diode · failedTHE LAVATORY FLOOR EMERGENCY LIGHT IS INOP. IT DOES NOT COME ON IN EITHER THE ARM (NO POWER ON AIRCRAFT) OR IN THE ON POSITION. RE SPLICED THE DIODE. OPS CHECK GOOD. IAW SPM 20-30-25.SDR AALA202405022403Connector · brokenAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANT REPORTS EMERGENCY LIGHTS ON RIGHT SIDE OF AIRCRAFT ARE BLINKING. **SUPPLEMENTAL REPORT FOR (AALA202404302403): REPAIR BROKEN WIRE TO TO CONNECTOR D10012 AND REMOVE AND REPLACED 17 DEF WALL LIGHT. PER AMM 22-21-00**(CSDR FDEA202404260297Switch · failedAIRPLANE HAD A STRONG ACRID SMOKE SMELL WHEN RUNWAY TURNOFF LIGHT WERE TURNED ON. FOUND RIGHT RUNWAY TURNOFF SWITCH BAD. WHEN SWITCH ACTIVATED SMOKE EMITS FROM RT RUNWAY TURNOFF SWITCH. REMOVED AND REPLACED OVERHEAD PANEL P5 PER SMP, OPS CHECK LIGHT FUNSDR AALA202404267458Ground Wire · brokenAIRCRAFT WAS GROUNDED: SEAT 22ABC AISLE EMERGENCY LIGHT WILL NOT ILLUMINATE. UPON FURTHER INSPECTION FOUND BROKEN GROUND WIRE UNDER FLOOR TRACK UNDER SEAT 22A. REPAIRED WIRE IAW ESPM 20-53-21-0201. OPS CHECK GOOD. OK FOR SERVICE.SDR DALA2024042604714Wire Harness · damagedSEAT FLOOR PROXY LIGHTS INOP. REPAIRED WIRING HARNESS PER A330 AMM 33-52.SDR DALA2024042404679Connector · unsecureSHIP 3329 EMER LIGHTS AT 40B & 42B INOP. CORRECTIVE ACTION: SECURED CONNECTIONS AT SEATS 40B & 42B LIGHTS CK OK. (5308866)SDR DXTA2024042411584Connector · unsecureLAV FLOOR EMERGENCY LIGHT INOP GAINED ACCESS TO AIRCRAFT. APPLIED ELECTRICAL POWER AND TURNED ON EMERGENCY LIGHTS, VERIFIED THAT LAV FLOOR LIGHT IS NOT ON. TURNED OFF ELECTRICAL POWER, AND EMERGENCY LIGHTS. REMOVED LAV EMERG LIGHT PANEL, PERFORMED GVI ON PANELSDR AALA202404249091Connector · disconnectedAIRCRAFT WAS NOT GROUNDED: AISLE SEAT MOUNTED EMERGENCY LIGHTS INOP AT ROW 17 AND 18 SECURED WALL MOUNTED PLUG (AALA202404249091) AND REPLACED COVER (AALA202404241466) REFERENCE AMM 25-21-41.SDR AALA202404230550Wire · cutAIRCRAFT WAS GROUNDED: SEAT 17A EMERGENCY EXIT LIGHT HAS BEEN RIPPED OFF OF THE WALL. ACCOMPLISHED WIRE REPAIR (AALA202404230550), PER SWPM 20-30-12 AND WDM 33-51-21. REMOVED AND REPLACED EMERGENCY EXIT SIGN LIGHT ASSEMBLY (AALA202404231454), PER AMM 33-51-01.SDR AALA202404252352Connector · defectiveAIRCRAFT WAS NOT GROUNDED: MAINTENANCE FOUND EMERGENCY LIGHT AT SEAT ROW 11 INOPERATIVE DURING SYSTEM TEST OF THE EMERGENCY LIGHTING SYSTEM. MAINTENANCE REPLACED EMERGENCY LIGHT CONNECTOR AT SEAT ROW 11 AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.SDR DALA2024042204634Wire · damagedSHIP 3302 SEAT MOUNTED EMERGENCY LIGHT AT 58B INOP. CORRECTIVE ACTION: REPAIRED WIRING PER A330 AMM 33-52. (5844246)SDR DALA2024042204640Socket · damagedSHIP 3303 PATH LIGHTS INOP AT SEATS 32JH-34JH. CORRECTIVE ACTION: REPLACED SOCKET AT PLUG REF ESPM 20-48 OPS CHECK OF PATH LIGHTING OK. (5644119)SDR AALA202404225884Connector · disconnectedAIRCRAFT WAS NOT GROUNDED: EMERGENCY EXIT PATH LIGHTS INOP AT ROWS 11, 20, AND 21. FOUND CONNECTOR AT ROW 20/21 DISCONNECTED. RECONNECTED CANON PLUG AT ROW 20/21.SDR SWAA2024042377338Circuit Breaker · trippedINFO ONLY FOUND EMERGENCY PANEL LIGHT BREAKER POPPED CONTACTED DAVE IN MOC -NO 10 DAY HISTORY - PERFORMED ONE TIME RESET BREAKER REMAINED CLOSED <BR>P6-3 BREAKER D8<[01] 02 - INSPECTED PER [GENERAL MPM 52.06.05 (INFO ONLY ITEM; NOTED BY MX)]<BR>NOTED BY MX REF
Back to JASC 3397