SDR AALA20001218Wire · brokenDFW - DURING OVER-NIGHT MAINTENANCE, EMERGENCY EXIT LIGHT ON AFT AIRSTAIR INOPERATIVE. REPAIRED BROKEN WIRE. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)SDR ASAA0040100Wire · disconnectedANC - FLT 140 - THE EMERGENCY EXIT FLOOR TRACK LIGHTS AT ROWS 14-16 WERE FOUND TO BE INOPERATIVE. RECONNECTED WIRING/LIGHT ASSEMBLY AND LIGHTS OPERATED NORMALLY. (M)SDR ASAA0080474Wire · disconnectedLAS - PRIOR TO FLT 601, THE EMERGENCY EXIT FLOOR TRACK LIGHTS AT ROWS 20-23 WERE FOUND TO BE INOPERATIVE. CONTRACT MAINTENANCE RECONNECTED WIRING/LIGHTS AND THE LIGHTS OPERATED NORMALLY. (M)SDR C2XA00IA218Wire · brokenDURING CONTINENTAL EXPRESS C-CHECK, THE LAST EMERGENCY AISLE PATH LIGHT STRIP WAS FOUND WITH A BROKEN WIRE. MAINTENANCE REMOVED AND REPLACED THE AFFECTED LIGHT STRIP IAW EMB145 MM 33-50-00, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE. (M)SDR ASAA0080471Wire · brokenSEA - PRIOR TO DEPARTURE OF FLIGHT 584 - CREW REPORTED THE EMERGENCY FLOOR TRACK LIGHTS IN THE FORWARD CABIN WERE INOPERATIVE. REPAIRED BROKEN WIRE IN FLOOR TRACK AT ROW 3 AND OPERATED NORMALLY. (M)SDR AALA20001178Wire · brokenDFW - DURING OVERNIGHT MAINTENANCE, STAIRWELL EMERGENCY LIGHT INOPERATIVE. REPAIRED BROKEN WIRE. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)SDR ASAA0080468Wire · brokenANC - PRIOR TO DEPARTURE OF FLIGHT 190, CREW REPORTED THE EMERGENCY FLOOR TRACK LIGHT WIRES AT ROW 24 WERE EXPOSED. REPAIRED BROKEN WIRE IN FLOOR TRACK AT ROW 24 AND OPERTED NORMALLY. (M)SDR AALA20001175Wire · brokenDFW - DURING OVERNIGHT MAINTENANCE, TAIL CONE EMERGENCY LIGHT ON RAIL INOPERATIVE. REPAIRED BROKEN WIRE ON LIGHT. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)SDR C2XA00IA208Wire · brokenIAH - DURING POST FLIGHT INSPECTION, THE CREW REPORTED THAT THE FIRST TOW RED AND WHITE AISLE PATH EMERGENCY LIGHTS WERE INOPERATIVE. MAINTENANCE REPAIRED A BROKEN WIRE IN THE LIGHT TRACK, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE. (M)SDR AALA20001173Wire · brokenSFO - DURING OVER-NIGHT, MAINTENANCE EMERGENCY EXIT ESCAPE PATH LGIHTS AT SEATS 22H, 24A, AND 26A INOPERATIVE. REPAIRED BROKEN WIRE AT SEAT 24A. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)SDR C2XA00IA207Wire · brokenIAH - DURING A-CHECK INSPECTION, THE FIRST FOUR EMERGENCY FLOOR LIGHTS WERE FOUND TO BE INOPERATIVE. MAINTENANCE REPAIRED A BROKEN WIRE IN THE LIGHT TRACK, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE. (M)SDR AALA20001169Wire · brokenDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT ESCAPE PATH LIGHTS FROM ROW 20 TO ROW 27 ON RIGHT SIDE INOPERATIVE. REPAIRED BROKEN WIRE AT ROW 20. SYSTEM GROUND CHECK NORMAL OPERATION. (M)SDR ASAA0080464Wire · brokenSEA - AFTER ARRIVAL OF FLIGHT 759, CREW REPORTED THE EMERGENCY FLOOR TRACK LIGHT COVER DAMAGED AND SECTIONS OF THE EMERGENCY FLOOR TRACK LIGHTS IN THE AFT CABIN INOPERATIVE. REPAIRED BROKEN WIRE IN FLOOR TRACK AT ROW 28 AND OPERATED NORMALLY. (M)SDR AALA20001170Wire · shortedSFO - DURING OVER-NIGHT MAINTENANCE, EMERGENCY EXIT ESCAPE PATH LIGHTS AT SEATS 24A AND 24B INOPERATIVE. REPAIRED WIRE AT ROW 20. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)SDR AALA20001162Wire · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT OVER TAIL CONE HANDLE INOPERATIVE. REPAIRED EMERGENCY EXIT LIGHT ASSEMBLY OVER TAIL CONE HANDLE. SYSTEM GROUND CHECKED NORMAL OPERATION. (X)SDR SWAA001253Wire · shortedDURING SCHEDULED D CHECK, FOUND EMERGENCY LIGHT CONTROL C/B TRIPPED WHEN SWITCH TURNED ON. SPLICED LIGHTING WIRE SECTION PER MM.SDR ASAA0040098Wire · disconnectedPDX - PRIOR TO FLIGHT 521 - THE EMERGENCY EXIT FLOOR TRACK LIGHTS AT ROWS 26 AND AFT WERE FOUND TO BE INOPERATIVE. RECONNECTED WIRING AND LIGHTS OPERATED NORMALLY. (M)SDR ASAA0080418Wire · disconnectedSAN - DURING MAINTENANCE CHECK, THE EMERGENCY FLOOR TRACK LIGHTS IN THE FORWARD CABIN WERE FOUND INOPERATIVE. RECONNECTED WIRING IN FLOOR TRACK AND OPERATED NORMALLY. (M)SDR AALA20001117Wire · damagedMIA - DURING OVERNIGHT MAINTENANCE, EMERGENCY ESCAPE FLOOR PATH LIGHTING AT SEAT 21H TO 24H INOPERATIVE. REPAIRED EMERGENCY ESCAPE FLOOR PATH LIGHTING WIRE AT PIN B OF PLUG 5750. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR ASAA0080417Wire · disconnectedSEA - DURING MAINTENANCE CHECK, THE EMERGENCY FLOOR TRACK LIGHTS IN THE FORWARD CABIN WERE FOUND INOPERATIVE. RECONNECTED WIRING TO LIGHT ASSEMBLY AT ROW 3 AND OPERATED NORMALLY. (M)SDR AALA20001113Wire · brokenDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT ESCAPE PATH LIGHTS AT COFFEE BAR IN FIRST CLASS INOPERATIVE. REPAIRED EMERGENCY EXIT ESCAPE PATH LIGHT WIRING AT COFFEE BAR. SYSTEM GROUND CHECK NORMAL OPERATION. (M)SDR 2000UALA00398Wire · failedEEL LIGHTS ON FLOOR FROM ROW 18 TO ROW 24 ARE INOPERATIVE. *S/D* REPAIRED EEL LIGHTING PIG TAIL AT ROW 22 LEFT. SYSTEM CHECKS OK.SDR SWAA001217Wire · exposedEEPLS WIRING EXPOSED AT MID CABIN. REPAIRED TRACK LIGHT ASSY PER MM.SDR AALA20001109Wire · brokenDURING OVERNIGHT MAINTENANCE EMERGENCY EXIT ESCAPE PATH LIGHTS INOPERATIVE. REPAIRED EMERGENCY EXIT ESCAPE PATH LIGHT WIRING. SYSTEM GROUND CHECK NORMAL OPERATION.SDR TWAA0010402Wire · exposedTHE EGRESS LIGHT WIRING WAS EXPOSED AND SEPARATED BETWEEN ROWS 16 AND 17 ON RT SIDE OF AISLE. SPLICED THE BREAK AND SECURED THE WIRES. CHECK-C 9-19-99 STL. ---CLOSED---SDR ASAA0040095Wire · disconnectedSEA - DURING MAINTENANCE CHECK, THE EMERGENCY EXIT FLOOR TRACK LIGHTS AT ROWS 12 AND 13 WERE FOUND TO BE INOPERATIVE. RECONNECTED WIRING AND LIGHTS OPERATED NORMALLY. (M)SDR AALA20001102Wire · brokenDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT ESCAPE PATH LIGHTS AT SEAT 26D INOPERATIVE. REPAIRED WIRING AT SEAT 26D. SYSTEM GROUND CHECK NORMAL OPERATION. (M)SDR AALA20001100Wire · brokenORD - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT ESCAPE PATH LIGHTS AT SEAT 29C INOPERATIVE. REPAIRED WIRING AT SEAT 29C. SYSTEM GROUND CHECK NORMAL OPERATION. (M)SDR AALA20001080Wire · shortedDTW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT ESCAPE PATH LIGHTS FROM ROWS 21 TO AFT, INOPERATIVE. REPAIRED WIRE AT SEAT 30. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)SDR AALA20001090Wire · brokenDFW DURING OVERNIGHT MAINTENANCE EMERGENCY EXIT ESCAPE PATH LIGHTS BETWEEN FIRST CLASS AND COACH INOPERATIVE. REPAIRED BROKEN WIRE FOR EMERGENCY EXIT ESCAPE PATH LIGHTS BETWEEN FIRST CLASS AND COACH. SYSTEM GROUND CHECK NORMAL OPERATION.SDR ASAA0040085Wire · disconnectedPDX - DURING MAINTENANCE CHECK, THE EMERGENCY EXIT TRACK LIGHTS AT ROWS 21-25 WERE FOUND TO BE INOPERATIVE. RECONNECTED WIRING/LIGHTS AND THE LIGHTS OPERATED NORMALLY. (M)SDR DLL19001220Wire · brokenFOUND DURING LAYOVER THREE FOOT SECTION OF EMERGENCY TRACK LIGHTING AT LEFT SIDE OF MIDDLE GALLEY INOPERATIVE - REPAIRED BROKEN WIRE IN TRACKSDR AALA20001069Wire · brokenDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT ESCAPE PATH LIGHTS FROM RIGHT FIRST CLASS TO SEAT 20G INOPERATIVE. REPAIRED WIRE AT SEAT 2D. SYSTEM GROUND CHECK NORMAL OPERATION. (M)SDR AALA20001070Wire · brokenBOS DURING OVERNIGHT MAINTENANCE EMERGENCY EXIT ESCAPE PATH LIGHTS FROM FORWARD COAT CLOSET TO FORWARD GALLEY INOPERATIVE. REPAIRED WIRING SYSTEM GROUND CHECK NORMAL OPERATION.SDR GTIA000238Wire · looseISP - FLT 349 - LOOSE WIRE IN FLOOR PATH LIGHTING. REPAIRED LOOSE WIRE IN FLOOR PATH LIGHTING. (M)SDR AU000501Wire · broken(AUS) CABIN DOME LIGHT DIMMER POTENTIOMETER WIRE BROKEN AND SHORT CIRCUITING.SDR AALA20001063Wire · brokenDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT ESCAPE PATH LIGHTS IN CABIN INOPERATIVE. REPAIRED WIRING FOR EMERGENCY EXIT ESCAPE PATH LIGHTS. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)SDR ASAA0010076Wire · disconnectedSEA - DURNIG MAINTENANCE CHECK, THE EMERGENCY EXIT TRACK LIGHTS WERE FOUND TO BE INOPERATIVE. REPAIRED AFT EMERGENCY EXIT TRACK LIGHT WIRING AND LIGHTS OPERATED NORMALLY. (M)SDR AALA20001051Wire · brokenDFW - DURING OVERNIGHT MAINTENANCE, REAR STAIR EMERGENCY LIGHTS INOPERATIVE. REPAIRED REAR STAIR EMERGENCY LIGHT WIRES. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)SDR AALA20001049Wire · brokenLAX - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT ESCAPE PATH LIGHTS AT ROW 21 INOPERATIVE. REPAIRED WIRE AT ROW 21. SYSTEM GROUND CHECK NORMAL OPERATION. (M)SDR AALA20001050Wire · brokenDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT ESCAPE PATH LIGHT AT R2 DOOR INOPERATIVE. REPAIRED WIRE AT R2 DOOR. SYSTEM GROUND CHECK NORMAL OPERATION. (M)SDR AWXA0000400Wire · brokenNON ROUTINE LINE, EMERGENCY LIGHT INOP AT SEAT 3C. REPAIRED BROKEN WIRE AT CONNECTOR, OPS CHECK GOOD.SDR AWXA0000399Wire · brokenNON ROUTINE LINE, EMERGENCY LIGHTS NOT WORKING AT ROW 29 AND 31. FOUND WIRES CUT AND STOWED AT ROW 29 AND WIRE NOT CONNECTED TO CONNECTOR AT ROW 31. REPAIRED WIRING AT ROW 29 AND 31, OPS CHECK GOOD.SDR AALA20001048Wire · brokenDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT IN STAIRWELL INOPERATIVE. REPAIRED WIRE CONNECTIONS. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)SDR GTIA000230Wire · brokenDTW - EMERGENCY FLOOR TRACK LIGHTING FORWARD SECTION INOPERATIVE. REPAIRED BROKEN WIRE OPS CHECKS GOOD IAW DC9 MM 33-53-00. (M)SDR GTIA000227Wire · exposedACY - FLT 208 - EMERGENCY TRACK FLOOR LIGHTING IN GALLEY AREA WIRES SHOWING. RE-SECURED TRACK LIGHT WIRES AND STRIP, OK TO CONTINUE. (M)SDR AALA20001031Wire · brokenDFW - DURING OVERNIGHT MAINTENANCE, AFT STAIRS SIDEWALL EMERGENCY LIGHTS INOPERATIVE. REPAIRED WIRE SPLICE JUST AFT SIDE WALL EMERGENCY LIGHT. SYSTEM GROUND CHECK NORMAL OPERATION. (M)SDR SWAA001127Wire · disconnectedEEPLS WIRING DISCONNECTED. REONNECTED WIRES PER MM.SDR AU000519Wire · burned(AUS) SIDEWALL LIGHTING SYSTEM TOMBSTONE AT POSITION 40A SMOKING FROM POWER WIRE.SDR TWAA0009501Wire · disconnectedDURING ROUTINE INSPECTION, IT WAS NOTED THAT EGRESS FLOOR LIGHTING WAS INOP. SPLICED IN REPLACEMENT JUMPER CABLE. AC06 05-18-00 LAX.
Back to JASC 3397