JASC 3397
Service difficulty reports · 22,670
Reports filed under 3397 · Light System Wiring, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3397' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3397' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA9880057Wire · defectiveSEA - PRIOR TO DEPARTURE FO FLT 722, CREW REPORTED THE EMERGENCY FLOOR TRACK LIGHTS IN THE FORWARD CABIN WERE INOPERATIVE. REPAIRED WIRE IN FLOOR TRACK AND OPERATED NORMALLY. (M)SDR 9804821227Wire · brokenDURING LINE CHECK, FOUND EMERGENCY LIGHTS INOPERATIVE AT SEAT ROWS 22 TO 30 OUTBOARD SIDE. FOUND BROKEN WIRE AT PASSENGER SEAT 30A. SECURED WIRE, OPERATIONAL CHECK OK.SDR 9804749150Wire · brokenDURING LINE CHECK, FOUND A SECTION OF WIRING FOR EMERGENCY EXIT FLOOR LIGHTING PULLED OUT AT FORWARD END OF CABIN. MAINTENANCE INSTALLED NEW WIRE CONNECTION, OPERATIONAL CHECK OK.SDR AALA980554Wire · failedDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY LIGHTS IN AFT STAIR AREA INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT WIRE AND SPLICE IN TAIL COMPARTMENT. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR WWMA9800054Wire · looseDURING PREFLIGHT, THE EMERGENCY FLOOR LIGHTS AT ROWS 6BC AND 7BC FAILED TO ILLUMINATE. MAINTENANCE FOUND A SOLDER CONNECTION AT FUSE HAD WORK HARDENED, RESOLDERED WIRE AND PERFORMED OPS CHECK.SDR AALA980541Wire · brokenDFW - DURING OVERNIGHT MAINTENANCE, OVERHEAD EMERGENCY EXIT AISLE LIGHT AT ROW 13 INOPERATIVE. REPAIRED WIRE ON ELECTRICAL CONTACT SWITCH. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA980523Wire · corrodedDFW - DURING OVERNIGHT CHECK, EMERGENCY LIGHT FOR TAIL CONE RELEASE HANDLE WAS INOPERATIVE. REPLACE SPLICES FOR LIGHT ON TAIL CONE RELEASE HANDLE. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR F3LA98009Wire · loosePHX - DURING SERVICE CHECK, MAINTENANCE REPORTED FLOOR PROXIMITY LIGHTING AT ROW 4 A, B, C INOPERATIVE. MAINTENANCE REPAIRED WIRING AND SECURED WIRING HARNESS AND SYSTEM CHECKED OK. (M)SDR 98ZZZX1435Wire · chafedRIGHT LANDING LIGHT INOPERABLE. FOUND WIRE BUNDLE CHAFING AGAINST FORWARD VENTRAL TANK TRANSFER VALVE ASSEMBLY. LOCATION IS BETWEEN WIRE BUNGEE 'DF' AND CONNECTOR 'JA-D9'. UPON REMOVAL OF FORWARD VENTRAL TANK, THE WIRING FOR THE FUEL QUANTITY SYSTEM OF THE SDR ASAA9840055Wire · disconnectedSEA - DURING MAINTENANCE CHECK, THE EMERGENCY EXIT FLOOR TRACK LIGHTS AT ROW 17 AND THE AFT FOUR LIGHTS WERE FOUND TO BE INOPERATIVE. RECONNECTED WIRING AND LIGHTS OPERATED NORMALLY. (M)SDR AALA980513Wire · shortedDFW - DURING OVERNIGHT CHECK, EMERGENCY EXIT FLOOR PATH LIGHT IN MID AND AFT CABIN INOPERATIVE. REPAIRED SHORTED WIRE IN TAIL COMPARTMENT. REPLACED FORWARD/AFT MODULES AND BATTERIES. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR 9804559914Wire · brokenDURING LINE MAINTENANCE INSPECTION, FOUND EMERGENCY LIGHTS BETWEEN ROWS 18 THRU 20 INOPERATIVE. REPLACED BROKEN WIRE UNDER SEATS 19DEF, OPERATIONAL CHECK NORMAL.SDR SIMA9807402Wire · brokenORD - FLT 4147 - EMERGENCY ESCAPE PATH LIGHT INOP AT SEAT POSITION 3A. ITEM DEFERRED MEL 33-22. SPLICED BROKEN WIRE AND REPLACED BULB IAW STANDARD PRACTICE. OPS CHECK GOOD AT THIS TIME MEL CLEARED AND A/C RETURNED TO SERVICE. (M)SDR TSAA9833181Wire · brokenON SERVICE CHECK, FOUND LEFT OVERWING EMERGENCY EXIT IDENTIFIER INOP. WIRE FOUND BROKEN AT CONNECTOR, RECONNECTED WIRE SYSTEM CHECK GOOD. AIRCRAFT RETURNED TO SERVICE. (M)SDR AALA980494Wire · damagedMIA - FLT 1819 - DURING GROUND OPERATIONS THE OUTBOUND CREW REPORTED THE EMERGENCY EXIT FLOOR PATH LIGHTING FORWARD OF PASSENGER SEAT 3R WAS MISSING. REPLACED EMERGENCY EXIT FLOOR PATH LIGHTING STRIP FROM PASSENGER SEAT 3R FORWARD DUE TO 20 FEET OF WIRE BEINGSDR SIMA980722Wire · brokenONE FLORO PROX LIGHT INOP BY GALLEY DUE TO BROKEN WIRE. ISSUED MEL 33-22 AND RETURNED A/C TO SERVICE. REPAIRED BROKEN WIRE IN ACC WITH STD PRACTICES. PERFORMED OPERATIONAL CHECK SATISFACTORILY AND RETURNED A/C TO SERVICE. (M)SDR AALA980539Wire · failedDFW - DURING OVERNIGHT MAINTENANCE FIRST CLASS EMERGENCY EXIT FLOOR LIGHT TRACKING INOPERATIVE. REPAIRED SPLICE BETWEEN R2 LIGHTS. GROUND CHECKED NORMAL OPERATION. (M)SDR AALA980496Wire · brokenSFO - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT PASSENGER SEAT 28B INOPERATIVE. REPAIRED BROKEN EMERGENCY EXIT LIGHT WIRE AT PASSENGER SEAT 28B. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR ASAA9840054Wire · disconnectedPDX - DURING MAINTENANCE CHECK, THE AFT TWO EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND TO BE INOPERATIVE. RECONNECTED WIRING AND LIGHTS OPERATED NORMALLY. (M)SDR 9804239928Wire · pinchedDURING LINE MAINTENANCE INSPECTION, FOUND FORWARD CABIN FLOOR PROXIMITY EMERGENCY LIGHTS AND LIGHTS AT GALLEY DOOR REMAINING ON WITH SWITCH IN OFF POSITION. FOUND WIRES PINCHED AT SEAT 3C. REPAIRED WIRES AND REPOSITIONED. ALSO, REPLACED POWER SUPPLY, OPERATSDR ASAA9880048Wire · chafedLAX - DURING MAINTENANCE CHECK, THE EMERGENCY FLOOR TRACK LIGHTS IN THE AFT CABIN WERE FOUND INOPERATIVE. REPAIRED CHAFFED WIRE IN FLOOR TRACK AND OPERATED NORMALLY. (M)SDR ASAA9840053Wire · disconnectedPDX - DURING MAINTENANCE CHECK, THE AFT TWO EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND TO BE INOPERATIVE. RECONNECTED WIRING AND LIGHTS OPERATED NORMALLY. (M)SDR 9804119967Wire · brokenDURING LINE MAINTENANCE INSPECITON, FOUND EMERGENCY LIGHTS ON TAIL CONE WALKWAY AND RIGHT RELEASE HANDLE INOPERATIVE. REPAIRED TWO BROKEN WIRES IN TAIL CONE AND REPLACED BATTERY PACK, OPERATIONAL CHECK NORMAL.SDR ASAA9840046Wire · disconnectedSEA - DURING MAINTENANCE CHECK, THE AFT THREE EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND TO BE INOPERATIVE. RECONNECTED WIRING AND LIGHTS OPERATED NORMALLY. (M)SDR 9804059917Wire · brokenDURING LINE MAINTENANCE INSPECTION, FOUND TAIL CONE EMERGENCY LIGHTS INOPERATIVE. FOUND POWER SUPPLY DISARM WIRE BROKEN IN TAIL CONE AREA. REPAIRED WIRE AND REPLACED POWER SUPPLY, OPERATIONAL CHECK NORMAL.SDR COMA9860051Wire · failedEMERGENCY LIGHTS INOP ROWS 2 THRU 5. REPLACED EMERGENCY LIGHT POWER STRIP.SDR ASAA9840045Wire · disconnectedPDX - DURING MAINTENANCE CHECK, THE AFT TWO EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND TO BE INOPERATIVE. RECONNECTED WIRING AND LIGHTS OPERATED NORMALLY. (M)SDR ASAA9840044Wire · disconnectedSEA - DURING MAINTENNCE CHECK, THE EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND INOPERATIVE AT ROWS 15 THROUGH 17. RECONNECTED WIRING AND LIGHTS OPERATED NORMALLY. (X)SDR AALA980442Wire · brokenDFW - DURING OVERNIGHT MANTENANCE, EMERGENCY EXIT LIGHTS IN CABIN WOULD NOT ILLUMINATE. REPAIRED TWO OPEN CIRCUITS IN EMERGENCY EXIT LIGHT SYSTEM ZONE 'A'. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA980433Wire · brokenDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY FLOOR LIGHTING AT FORWARD GALLEY WAS INOPERTIVE. REPAIRED BROKEN WIRE AT EMERGENCY FLOOR LIGHT FORWARD GALLEY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR TWAA9803003Wire · brokenSTL - FLT 433 - A BURNING SMELL WAS DETECTED IN REAR OF CABIN AT 300 FT AGL. REPAIRED BROKEN WIRE AT WIRE BUNDLE FOR LIGHTING BALLAST, ROW 19 RT SIDE. (M)SDR ORJA9837Wire · disconnectedEMERGENCY LIGHTS AT SEAT 9DEF WILL NOT ILLUMINATE. RECONNECTED BROKEN WIRE, OPS CHECK OK. (M)SDR AALA980437Wire · brokenLHR - DURING MAINTENANCE, EMERGENCY PATH LIGHT AT SEAT 21B INOPERATIVE. REPLACED EMERGENCY PATH LIGHT CABLE ASSEMBLY AT SEAT 21B. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA980415Wire · brokenDFW - DURING OVERNIGHT MAINTENANCE, FORWARD EMERGENCY EXIT FLOOR PATH LIGHTS WERE INOPERATIVE. REPAIRED EMERGENCY FLOOR PATH WIRE AT FORWARD CABIN. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR ORJA9836Wire · disconnectedEMERGENCY LIGHTS OUT ROW 6DEF AND 30DEF INOP. RECONNECTED BROKEN WIRES, OPS NORMAL. (M)SDR DLL10980493Wire · brokenEMERGENCY TRACK LIGHTING FIRST CLASS LEFT SIDE 2ND RED BULB INOP. REPLACED SOCKET AND LAMP, OPS NORMAL.SDR ASAA9880037Wire · disconnectedSEA - FLT 232 - PRIOR TO DEPARTURE, THE EMERGENCY FLOOR TRACK LIGHTS IN THE FIRST CLASS CABIN WERE INOPERATIVE. REPAIRED FLOOR TRACK WIRING IN FIRST CLASS CABIN AND LIGHTS OPERATED NORMALLY. (M)SDR MASA98042Wire · damagedFLT 4604 - DEN-GJT - DURING PREFLIGHT, PILOT REPORTED THE EMERGENCY LIGHTS WERE NOT WORKING PROPERLY. MAINTENANCE REPAIRED A WIRE TO THE FLGIHT ATTENDANTS EMERGENCY LIGHT SWITCH AND REPLACED THE DIODES. AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR 9803529751Wire · looseDURING LINE MAINTENANCE INSPECTION, FOUND MID CABIN OVERHEAD EMERGENCY LIGHT INOPERATIVE. TIGHTENED LOOSE WIRE AT BATTERY PACK, OPERATIONAL CHECK NORMAL.SDR USAASB98049Wire · brokenPIT - MAINTENANCE FOUND THE LOW LEVEL EMERGENCY LIGHTS AT SEAT ROWS 6 THROUGH 9 INOP. MAINTENANCE REPAIRED A BROKEN WIRE NEAR SEAT ROW 9. OPERATIONAL CHECK GOOD. (M)SDR PCAA9800738Wire · looseSEVERAL EMERGENCY FLOOR PROXIMITY LIGHTS INOPERATIVE. SECURED SEVERAL LOOSE JUMPER WIRES, REPAIRED WIRING IN EMERGENCY PROXIMITY LIGHTING CIRCUIT AND REPLACED FORWARD AND AFT BATTERY PACK FUSES. OPERATIONAL TEST OF SYSTEM NORMAL. AIRCRAFT RETURNED TO SERVICSDR 9803389916Wire · brokenDURING LINE MAINTENANCE INSPECTION, FOUND CATWALK EMERGENCY LIGHTS INOPERATIVE. REPAIRED BROKEN WIRING IN WIRE BUNDLE, OPERATIONAL CHECK NORMAL.SDR ORJA9834Wire · brokenEMERGENCY SEAT TRACK LIGHT INOP AT 15 DEF. REMOVED AND REPLACED LAMP AND REPAIRED WIRING, OPS CHECK GOOD. (M)SDR MASA98039Wire · shortedFLT 5508 - MIA-TLH - ON START UP IN MIA, CREW NOTICED THE EMERGENCY TRACK LIGHTS IN THE MIDDLE FLOOR SECTION WOULD NOT ILLUMINATE. MAINTENANCE ACTION WAS DEFERRED PER MEL 33-51-1. IN SUBSEQUENT MAINTENANCE, A SHORTED WIRE WAS REPAIRED. (M)SDR AALA980406Wire · shortedBNA - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTING WOULD NOT ILLUMINATE. REPAIRED SHORTED WIRE IN EMERGENCY FLOOR LIGHTING AT FORWARD GALLEY SIDEWALL LIGHT STRIP. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR 9803319863Wire · disconnectedDURING LINE CHECK, FOUND EMERGENCY LIGHTS DIM. MAINTENANCE ACCOMPLISHED EA 98-0911488. OPERATIONAL CHECK OK.SDR DL76L980477Wire · brokenON LAYOVER CHECK, FOUND EMERGENCY LIGHT INOP AT 22B. FOUND BROKEN WIRE AT PLUG NEAR SIDEWALL. REPAIRED BROKEN WIRE. EMERGENCY LIGHT CK OK.SDR AALA980402Wire · brokenDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY FLOOR LIGHTING AT PAX SEAT ROWS 7 TO 16 WAS INOPERATIVE. REPAIRED BROKEN WIRE AT EMERGENCY FLOOR LIGHT PAX SEAT ROWS 7 TO 16. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR 9803299138Wire · misinstalledDURING PREFLIGHT, THE EMERGENCY EXIT LIGHTS CHARGING CIRCUIT BREAKER WAS FOUND TO BE POPPED. MAINTENANCE CORRECTED MIS-WIRING AT ATTENDANT'S EMERGENCY EXIT LIGHT SWITCH AND REPLACED THE RIGHT NACELLE EMERGENCY BATTERY PACK. OPERATIONAL CHECK NORMAL.SDR DLM88980442Wire · chafedAFT SECTION OF FLOOR TRACK EMERGENCY LIGHTS FROM SEAT 30 TO 38 INOP. FOUND WHEN REPLACING MISSING TRACK LIGHT SOCKET AT ROW 28. FOUND WIRE CHAFED AT LIGHT ASSEMBLY L2-848. REPAIRED WIRE, CK OK.
Back to JASC 3397