JASC 3397
Service difficulty reports · 22,670
Reports filed under 3397 · Light System Wiring, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3397' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3397' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA960771Wire · brokenAT GATE, FOUND BOTH AFT EMERGENCY EXIT LIGHTS REMAINING ILLUMINATED AT ALL TIMES. REMOVED AFT GALLEY AND REPAIRED BROKEN WIRE. OPS CHECKED OK PER BOEING M/M.SDR CALA9601248Wire · damagedTHE EMERGENCY PATH LIGHTING BETWEEN SEAT ROWS 6 ABC - 8 ABC WERE FOUND INOPERATIVE DURING AN EMERGENCY LIGHT OPERATIONAL CHECK. MAINTENANCE FOUND A FLOOR HARNESS FEEDER WIRE DAMAGED. THE WIRE WAS REPAIRED AND OPERATIONAL CHECKS WERE GOOD IAW MM 33-51-0.SDR AWXA960422Wire · brokenPHX - FLT 2081 - DURING ROUTINE MAINTENANCE CHECK, FOUND ROW 11 EMERGENCY LIGHT INOP. REPAIRED WIRE. OPS CHECK OK. (M)SDR ASAA9680163Wire · disconnectedSEA - PRIOR TO DEPARTURE OF FLT 203 - CREW REPORTED, THE EMERGENCY FLOOR TRACK LIGHTS IN THE FORWARD CABIN WERE INOPERATIVE. RECONNECTED WIRING AT ROW 3 AND OPERATED NORMALLY. (M)SDR AALA961193Wire · brokenJFK - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS BETWEEN PAX SEAT ROWS 20AB TO 23AB INOPERATIVE. REPLACED BROKEN POWER FEED WIRE FROM CABIN SIDEWALL CONNECTOR TO LIGHT STRIP. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AWXA960420Wire · tornPHX - FLT 2035 - DURING ROUTINE MAINTENANCE CHECK, FOUND EMERGENCY FLOOR LIGHTING WIRE TORN FROM FLOOR. REPAIRED EMERGENCY FLOOR LIGHTING WIRES AND TRACK SYSTEM. OPS CHECK GOOD. (M)SDR AWXA960419Wire · brokenPHX - FLT 2211 - REFERENCE MEL 33-51-03, EMERGENCY LIGHT ROW 20 INOP. REPAIRED BROKEN WIRE UNDER SEAT. OPS CHECKED NORMAL. MEL REMOVED. (M)SDR AWXA960416Wire · brokenPHX - FLT 98 - DURING ROUTINE MAINTENANCE CHECK, FOUND FLOOR PROX EMERGENCY EXIT LIGHTS INOP AT SEATS 3,6, 14 AND 17. RESPLICED POWER WIRES AT SEATS ROWS 3, 6, 14 AND 17. OPS CHECK GOOD. (M)SDR AWXA960402Wire · brokenPHX - FLT 98 - DURING ROUTINE MAINTENANCE CHECK, FOUND FLOOR PROX EMERGENCY EXIT LIGHTS INOP AT SEATS 3, 6, 14 AND 17. RESPLICED POWER WIRES AT SEAT ROWS 3, 6, 14 AND 17. OPS CHECK GOOD. (M)SDR 9617259605Wire · brokenDURING LINE MAINTENANCE INSPECTION, FOUND EMERGENCY LIGHT AT SEAT 3C INOPERATIVE. REPAIRED BROKEN WIRE, OPERATIONAL CHECK NORMAL.SDR AWXA960476Wire · disconnectedPHX - FLT 700 - DURING ROUTINE MAINTENANCE CHECK, FOUND ROW 25 EMERGENCY LIGHT INOP. RECONNECTED TERMINAL. (M)SDR ASAA9640067Wire · disconnectedSEA - DURING MAINTENANCE CHECK, THE FORWARD TWO RED EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND INOPERATIVE. RECONNECTED WIRING AND LIGHTS OPERATED NORMALLY. (M)SDR 9616939952Wire · brokenDURING LINE MAINTENANCE INSPECTION, FOUND FORWARD CABIN FLOOR PROXIMITY EMERGENCY LIGHTS INOPERATIVE. FOUND BROKEN WIRE IN TRACK. REPAIRED WIRE, OPERATIONAL CHECK NORMAL.SDR 9616886304Wire · looseDURING LINE CHECK, FOUND FLOOR EMERGENCY LIGHTS INOPERATIVE FROM LAVATORY DR 4L2 TO ROW 57 AND AT ROWS 72 AND 73. RECONNECTED WIRES, OPERATIONAL CHECK GOOD.SDR TWRA96264Wire · brokenDURING DAILY CHECK, FOUND EVAC LIGHT UPPER DECK NEAR FLOOR FORWARD OF CREW SLIDE IS INOPERATIVE. REPAIRED BROKEN WIRE TO LIGHT ASSEMBLY. OPS CHECKED NORMAL PER MM 33-51-00. (M)SDR ASAA9680160Wire · disconnectedSEA - DURING MAINTENANCE CHECK, THE OVERHEAD EMERGENCY EXIT LIGHT IN THE TAILCONE AREA WAS FOUND INOPERATIVE. REPAIRED BROKEN WIRING AND LIGHT OPERATED NORMALLY. (M)SDR 9616959955Wire · pinchedDURING LINE MAINTENANCE INSPECTION, FOUND FORWARD RIGHT CABIN ENTRY DOOR EMERGENCY EXIT SIGN LIGHTS INOPERATIVE. FOUND WIRES PINCHED UNDER SEAT 1D. REPLACED FUSE, REPAIRED AND REPOSITIONED WIRES UNDER SEAT AND OPERATIONAL CHECK NORMAL.SDR TWRA96258Wire · brokenDURING DAILY CHECK, FOUND EMERGENCY EVAC LIGHT INOP AT ROW 7H. RESPLICED WIRE. OPS CHECKED NORMAL AS PER MM 33-51-00. (M)SDR ASAA9640066Wire · disconnectedSEA - DURING MAINTENANCE CHECK, THE AFT 2 EMERGENCY EXIT LIGHTS WERE FOUND TO BE INOPERATIVE. RECONNECTED WIRES AND LIGHTS OPERATED NORMALLY. (M)SDR GTIA96NK183Wire · misinstalledLAST SIX FEET OF FLOOR TRACK LIGHTS IN CABIN, AND FLOOR TRACK LIGHTS IN TAIL CONE, NOT ILLUMINATING WHEN POT IN TEST MODE. SWITCHED CROSSED WIRES ON B5-27 AS REQUIRED. OPS CHECKS GOOD IAW DC-9 MM CHAPTER 33. (M)SDR ASAA9640065Wire · brokenSEA - DURING MAINTENANCE CHECK, THE EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND INOPERATIVE AT ROWS 9-13. REPAIRED BROKEN WIRE AT FLOOR FEED AND LIGHTS OPERATED NORMALLY. (M)SDR AALA961134Wire · brokenDFW - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS BY PAX SEAT 3H INOPERATIVE. REPAIRED BROKEN EMERGENCY FLOOR LIGHT WIRE BY PAX SEAT 3H. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR ASAA9640064Wire · disconnectedSEA - DURING MAINTENANCE CHECK, ALL FOUR RED AND ONE WHITE EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND INOPERATIVE AT OVERWING EXITS. RECONNECTED TRACK LIGHT WIRING AND LIGHTS OPERATED NORMALLY. (M)SDR 96UAL900577Wire · brokenFORWARD GALLEY LT AISLE EMERGENCY LIGHT DOES NOT WORK. *S/D* REPLACED BROKEN LEAD IN, OPERATIONAL CHECKED SATISFACTORY.SDR AWXA960434Wire · disconnectedPHX - FLT 0589 - DURING ROUTINE MAINTENANCE CHECK, FOUND SEAT 1 A, B, EMERGENCY LIGHTS INOPERATIVE. RECONNECTED SPLICE. OPERATIONS OK. (X)SDR TWRA96215Wire · inoperativeDURING DAILY CHECK, FOUND FLOOR EVAC EGRESS LIGHT STRIP AT 'E' GALLEY INOP. REPAIRED HARNESS, OPS CHECKED OK PER MM 33-51-00. (M)SDR AWXA960497Wire · brokenPHX - FLT 2517 - DURING ROUTINE MAINTENANCE CHECK, FOUND NUMEROUS WIRES EXPOSED AT ROW 22, A, B, C. SOME BROKEN. REPAIRED EMERGENCY EXIT FLOOR TRACK WIRING. SYSTEM CHECKS GOOD. (X)SDR ASAA9640063Wire · disconnectedSEA - DURING MAINTENANCE CHECK, SIX EMERGENCY EXIT FLOOR TRACK LIGHTS IN MID CABIN WERE FOUND INOPERATIVE. RECONNECTED LIGHTS AND SECURED TRACK, LIGHTS OPERATED NORMALLY. (M)SDR USAASB96137Wire · shortedLGA - MAINTENANCE FOUND THE FORWARD CABIN FLOOR TRACK EMERGENCY LIGHTS INOP. ALSO, FOUND INOP WERE THE MAIN ENTRY DOOR AND SERVICE DOOR EXIT IDENTIFIERS. MAINTENANCE FOUND THE MAIN ENTRY DOOR EXIT IDENTIFIER LIGHT WIRING SHORTED OUT. REWIRED EXIT IDENTIFIERSDR AWXA960474Wire · cutLAS - FLT 2085 - DURING ROUTINE MAINTENANCE CHECK, FOUND L-1 DOOR BULKHEAD EMERGENCY EXIT LIGHT INOP. FOUND BULKHEAD/SIDEWALL WIRES CUT. SPLICED TOGETHER. OPS CHECK GOOD. (M)SDR TWRA96231Wire · brokenDURING DAILY CHECK, FOUND 1L DOOR JUMPSEAT EVAC LIGHT INOP. REPAIRED BROKEN WIRE 33-51-13. OPS CHECKED OK PER MM 33-51-00. (M)SDR TWRA96228Wire · shortedDURING DAILY CHECK, FOUND UPPER DECK ALL FLOOR EVAC LIGHTS INOP. FOUND WIRE SHORTED TO GROUND. REPAIRED WIRING PER MM 33-51-13. OPS CHECKED PER MM 33-51-00 PG 501. (M)SDR TWRA96225Wire · brokenDURING DAILY CHECK, FOUND R1 MED EMERGENCY LIGHT INOP. REPAIRED WIRE, OPS CHECKED GOOD PER MM 33-51-00. (M)SDR TWRA96223Wire · brokenDURING DAILY CHECK, FOUND 5L MED EMERGENCY LIGHT INOP. REPAIRED WIRING. OPS CHECKED OK PER IAW 33-51-00. (M)SDR SIMA962061Wire · failedORD - FLT 4212 - AIRSTAIR EMERGENCY LIGHT INOP. REPAIRED WIRING BETWEEN PIN L OF 15W AND PIN E OF PLUG 253VC. OPERATIONAL CHECK SATISFACTORY. AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR 9616009910Wire · looseDURING LINE MAINTENANCE INSPECTION, FOUND RIGHT OVERWING EMERGENCY EXIT LIGHTS INOPERATIVE. MAINTENANCE REPAIRED LOOSE GROUND CONNECTION. OPERATIONAL CHECK NORMAL.SDR 96ZZZX4364Wire · exposedDEN - FLT 752 - UPON ARRIVAL, FLIGHT CREW REPORTED EMERGENCY AISLE PATH LIGHTING WIRES EXPOSED AT ROW 11. MAINTENANCE REPAIRED WIRING AND SYSTEM CHECKED OKAY.SDR AWXA960417Wire · brokenPHX - FLT 0102 - DURING ROUTINE MAINTENANCE CHECK, FOUND SEAT 14C EXIT LIGHT INOPERATIVE. REPARIED BROKEN WIRE. OPERATIONS CHECK GOOD. (X)SDR USAASB96135Wire · brokenTPA - MAINTENANCE FOUND THE EMERGENCY LIGHTS INOP ON LEFT SEATAT EMERGENCY EXIT ROW. MAINTENANCE FOUND BROKEN WIRE. REPAIRED SAME. OPSCHECK GOOD. (M)SDR AWXA960495Wire · disconnectedPHX - FLT 2081 - DURING ROUTINE MAINTENANCE CHECK, FOUND SEAT 3C FLOOR PROX LIGHT OUT. RESECURED WIRE CONNECTOR. OPERATIONS CHECK GOOD. (X)SDR 9616129752Wire · brokenDURING LINE CHECK, FOUND EMERGENCY EXIT FLOOR LIGHTS INOPERATIVE AT FORWARD OVERWING EXIT. REPAIRED BROKEN WIRE AT RIGHT SIDEWALL. OPERATIONAL CHECK OK.SDR GTIA96NK180Wire · chafedEMERGENCY EXIT LIGHT AT REAR EDGE OF GALLEY SERVICE DOOR CONTINUOUSLY FLICKER IN FLIGHT. FOUND WIRE CHAFED ON LIGHT ASSEMBLY. REPAIRED AS NECESSARY. (M)SDR CALA9601048Wire · brokenINSPECTION FOUND SEAT 28 ABC EMERGENCY LIGHT INOPERATIVE. MAINTENANCE FOUND A BROKEN WIRE LEADING TO LAMP ASSEMBLY OF SEAT 28 ABC. THE WIRE WAS REPAIRED AND OPERATION CHECKED GOOD.SDR 9615729975Wire · brokenDURING PRE-FLIGHT CHECK, FOUND FLOOR PROXIMITY EMERGENCY LIGHTS IN FORWARD CABIN INOPERATIVE. MAINTENANCE REPAIRED AND RE-POSITIONED WIRE UNDER SEAT 3C. OPERATIONAL CHECK NORMAL.SDR TWRA96191Wire · brokenDURING DAILY CHECK, FOUND 30ABC, 40ABC, 58ABC SEAT EVAC LIGHT INOP. REPAIRED BROKEN WIRE UNDER SEAT, OPS CHECK OK PR MM 33-51-00. (M)SDR ASAA9640061Wire · disconnectedPDX - FLT 106 - EMERGENCY EXIT FLOOR TRACK LIGHTS INOPERATIVE AT ROW 15 (3 RED AND 2 WHITE). RECONNECTED WIRING TO LAMP SOCKETS AND LIGHTS OPERATED NORMALLY. (X)SDR AXWA960490Wire · brokenLAS - FLT 2687 - DURING ROUTINE MAINTENANCE CHECK, FOUND ROW 26 SEAT MOUNT EMERGENCY LIGHT INOPERATIVE, BOTH BULBS. REPAIRED WIRING FOR EMERGENCY LIGHT AT ROW 26. LIGHTS OPERATIONS CHECKS GOOD. (X)SDR AALA961065Wire · defectiveDFW - DURING OVERNIGHT CHECK, FOUND THE AFT STAIR SIDE WALL EMERGENCY EXIT LIGHT MARKERS INOPERATIVE. REPLACED WIRE SECTION FROM POWER LEADS TO AFT STAIR AREA. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA961064Wire · defectiveDFW - DURING OVERNIGHT CHECK, FOUND EMERGENCY EXIT FLOOR PATH LIGHTS INOPERATIVE, FORWARD OF FIRST CLASS TO MID-COACH SECTION. REPLACED TWO JUMPER WIRES. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR SWAA960673Wire · disconnectedDURING WALKAROUND CHECK, FOUND FLOOR EMERGENCY LIGHTS AT ROW 16 INOP. REPAIRED WIRE TO CONNECTOR AT LIGHT PER BOEING M/M.
Back to JASC 3397