JASC 3397
Service difficulty reports · 22,660
Reports filed under 3397 · Light System Wiring, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3397' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3397' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2020FA0000502Connector · missingROWS 35 AND 36 EMERGENCY LIGHTS INOPERABLE. REPLACED SIDE WALL CONNECTOR, IAW AWM 33-51-08. OPERATIONS CHECK GOOD, IAW MM 33-51-00.
SDR AALA202011179007Connector · inoperativeAIRCRAFT WAS GROUNDED. ROWS 35 AND 36 EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED SIDE WALL CONNECTOR, PER AWM 33-51-08.SDR F3LA2020111700045Connector · looseDISCREPANCY: FWD FACING EXIT LIGHT OVER EXIT ROW 13 INOPERABLE. CORRECTIVE ACTION: GROUND CONNECTOR TO EXIT LIGHT ASSEMBLY LOOSE. SECURED GROUND CONNECTOR, OPERATIONS CHECK OF EMERGENCY LIGHT SYSTEM GOOD, REF AMM 33-51-00-710-805-A.SDR AALA202011129003Light · disconnectedAIRCRAFT WAS NOT GROUNDED. EMERGENCY POWER SUPPLY UNIT EXIT LOAD EMERGENCY LIGHT FAULT. FOUND AFT EMERGENCY LEFT OVERWING LIGHT (63WL) DISCONNECTED, RECONNECTED OVERWING EMERGENCY LIGHT (63WL).SDR DALA2020111103672Connector · inoperativeROW 20 CEILING EMERGENCY DOME LIGHTING INOPERABLE. CORRECTIVE ACTION: R & R CONNECTOR 204WLA, PER AWM 33-51-02 SH3 AND ESPM 20-48-24.SDR DALA2020111303712Wire · shortedDURING INSPECTION FOUND EMERGENCY LIGHT CHECK W/C 3350-7390, ROWS 1-5 EMERGENCY LIGHTS INOPERATIVE. FOUND WIRES PULLED OUT OF ROW 5 SEAT MOUNTED EMERGENCY LIGHT AND SHORTED. REPLACED SAME AND REPLACED FUSES IN M2816 POWER SUPPLY, PER B737 AMM 33-51. EMERGENSDR AALA202011099005Feeder Cable · faultyAIRCRAFT WAS NOT GROUNDED. LEFT HAND ROW 18 EMERGENCY EXIT LIGHT INOPERATIVE. REMOVED AND REPLACED CABLE ASSEMBLY AT SEAT 18C EXIT LIGHT. OPERATIONS CHECKS NORMAL.SDR DALA2020111003656Connector · looseDURING INSPECTION FOUND SEAT 11D EMERGENCY LIGHT INOPERATIVE. FOUND LOOSE CONNECTOR UNDER SEAT, TIGHTENED CONNECTOR. PERFORMED OPERATIONS CHECK OF EMERGENCY LIGHTS, PER B737 AMM 33-51. OPERATIONS CHECK GOOD.SDR QXEA2020110600311Circuit Breaker · trippedEMERGENCY LIGHTS ILLUMINATE WITH EMERGENCY LIGHTS SWITCH IN "ARM" POSITION. REMOVED FROM SERVICE. FOUND CIRCUIT BREAKER "E3-EMERGENCY LIGHTS RELAY" OPEN. RESET CIRCUIT BREAKER, PER GPM 9.2.2.1. OPERATIONS TEST OF EMERGENCY LIGHTS GOOD, PER AMM 33-51-00-710SDR REXA2020110400736Connector · brokenEMERGENCY FLOOR PATH LIGHTING FROM ROWS 2 TO ROW 5 NOT LIGHTING UP. FOUND BROKEN CONNECTOR ON FLOOR TRACK LIGHT. REPLACED CONNECTOR, PER ESPM 20-17-00. EMERGENCY LIGHTS CHECK GOOD, PER AMM 33-51-00.SDR CALA2020110401240Connector · disconnectedEMERGENCY ESCAPE PATH LIGHTS INOPERABLE AT AISLE 34 LEFT AND RIGHT SIDE. RECONNECTED D9185 ON AISLE 34 EMERGENCY ESCAPE PATH LIGHTS, IAW B 767 WDM 33-51-15. OPERATIONS CHECK GOOD, IAW B767 AMM 33-15-10 ADD EMP: N.SDR SIMA20201031001Connector · unsecureRT OVERWING EMERGENCY LIGHT INOPERABLE. C/A: R & R RT OVERWING EMERGENCY LIGHT, IAW EMB AMM33-50-07-000-801-A AND 33-50-07-400-801-A. NO FIX, FOUND CANNON PLUG LOOSE. RETIGHTENED CANNON PLUG. OPERATIONS CHECKED GOOD.SDR DALA2020110603622Wire · disconnectedEMERGENCY EXIT SIGNS INOPERATIVE. CORRECTIVE ACTION: RECONNECTED WIRES. OPERATIONS CHECK GOOD, REF A320 AMM 33-50.SDR SWAA2020110427112Connector · disconnectedAFT GALLEY LEFT EMERGENCY EXIT LIGHT INOPERABLE. REINSTALLED ELECTRICAL CONNECTORS ON AFT GALLEY LEFT EMERGENCY EXIT LIGHT, AS PER B737 AMM 33-51-01-960-802. TEST OK, AS PER B737 AMM 33-51-00-720-801 AND 33-51-00-710-801.SDR SWAA2020110226886Connector · inoperativeAAR QC WALK: RT OVERWING LOWER LEFT EMERGENCY LIGHT INOPERABLE. RESECURED RT OVERWING LOWER LEFT EMERGENCY LIGHT CONNECTORS, AS PER REF B737 AMM 33-51-00-960-802. PERFORMED OPERATIONS CHECK AND FOUND NORMAL .SDR SWAA2020110226135Connector · inoperativeEMERGENCY EXIT SIGN LIGHT INOPERABLE AT LEFT LOWER OVERWING EMERGENCY EXIT DOOR. RECONECTED CONNECTOR D12448, AS PER SWPM 20-30-12 AND WDM 33-51-13 AND PERFORMED OPERATIONS CHECK, AS PER B737 AMM 33-51-00-710-801. TEST FOUND NORMAL.SDR AALA202010309013Connector · disconnectedAIRCRAFT WAS GROUNDED. EMERGENCY LIGHTS ROW 16-19 WILL NOT EXTINGUISH. FOUND CONNECTOR AT SEAT LEG DISCONNECTED. RECONNECTED CONNECTOR, PER STANDARD PRACTICES.SDR CALA2020102901221Wire · brokenROW 30-31 EMERGENCY LIGHTS ARE INOPERABLE. A3NB-33-3-6033, PER HAECO LCQ N/R 9292017/40017 GENERATED BY V894373. REPAIRED BROKEN EEPL WIRE FOR SEATS 30-31 LT, PER A310/A320 AWM 3 3-51-08 PG 2, ESPM 20-43-11-0101 A. OPERATION CHECKS GOOD, PER AMM 33-51-00-71SDR AALA202010289012Connector · misroutedAIRCRAFT WAS GROUNDED. FOUND NR 1 CABIN CEILING EMERGENCY LIGHT INOPERATIVE. REMOVED THAT LIGHT ASSEMBLY AND FOUND THE TWO PLUGS CRISSCROSSED. RESEATED PLUGS, IAW AMM 33.50.00 THE EMERGENCY LIGHTING SYSTEM TESTED NORMAL.SDR AALA202010269011Wire Harness · inoperativeAIRCRAFT WAS NOT GROUNDED. EMERGENCY AISLE WHITE LED LIGHT INOPERATIVE AT ROW 26ABC. REMOVED AND REPLACED SEAT EMERGENCY LIGHT HARNESS, PER ESPM 20-33-11.SDR AALA202010259001Wire · brokenAIRCRAFT WAS NOT GROUNDED. ROW 20 EMERGENCY EXIT LIGHT INOPERATIVE. BROKEN WIRE REPAIRED.SDR AALA202010239008Connector · disconnectedAIRCRAFT WAS NOT GROUNDED. EMERGENCY LIGHT INOPERATIVE SEAT 36. RECONNECTED SEAT 36 EMERGENCY LIGHT CONNECTOR.SDR AALA202010239011Connector · disconnectedAIRCRAFT WAS NOT GROUNDED. FOUND SEAT 6C EMERGENCY LIGHT INOPERATIVE. SUPPLEMENTAL INFORMATION: RECONNECTED CONNECTOR PLUG UNDER SEAT 6A, PER ESO 33457 AND CMM 25-26-77. SEAT 6C EGRESS LIGHTS OPERATION CHECK NORMAL. (CLOSED)SDR DALA2020102003407Connector · unsecureROW 11JH UNDERSEAT FLOOR EMERGENCY LIGHT INOPERABLE. CORRECTIVE ACTION: SECURED LIGHT ASSEMBLY CONNECTOR AT SEAT HARNESS. OPERATIONS CHECK GOOD, PER A330 AMM 33-51.SDR DALA2020102003411Connector · damagedSEAT 18 AB EMERGENCY LIGHT INOPERABLE. CORRECTIVE ACTION: REPINNED 18AB AISLE LIGHT CONNECTOR, PER A330 WDM 33-51-22. OPERATIONS TEST OK, PER A330 AMM 33-51.SDR AALA202010159004Wire · unsecureAIRCRAFT WAS NOT GROUNDED. SEAT 12C EMERGENCY LIGHTING WIRING LOOSE. REMOUNTED LIGHT ASSEMBLY AT SEAT 12C, PER AMM 33-50-00.SDR SIMA20201011005Connector · damagedEMERGENCY LIGHT STRIPS NR 1, 3, 5, 6, 7, 8 CONNECTOR WIRING DAMAGED/BROKEN. C/A COMPLETE: REPLACED EMERGENCY LIGHT STRIPS 1, 3, 5, 6, 7, AND 8, IAW EMB145 AMM 33-50-12 SEE NRTC BOW348179 FOR AIRCRAFT INSTALLATION AND OPERATIONAL CHECKSDR SIMA20201011003Connector · inoperativeREF AML PAGE 4674487 ITEM NR 1 "SERVICE DOOR EMERGENCY LIGHT INOPERABLE" MEL 33-29 AUTH NR 100120D-C. C/A: REPLACED CONNECTOR P178 & REPAIRED WIRE AT PIN C OF CONNECTOR P7128, IAW SWPM 20-50-01 & 20-21-00 SERVICE DOOR EMERGENCY LIGHT. OPERATIONS CHECK GOOD, SDR SIMA20201011002Connector · damagedSEAT 3 B/C EMERGENCY EXIT SIGN INOPERABLE. C/A: T/S SEAT 3 B/C EMERGENCY EXIT SIGN, IAW FIM TASK 33-50-00-810-804-A FOUND BACKPLATE ON CANNON PLUG TO BE LOOSE. OPERATIONS CHECK GOOD, NO FURTHER DEFECTS NOTED AT THIS TIME.SDR AALA202010119003Connector · looseAIRCRAFT WAS NOT GROUNDED: EMERGENCY POWER SUPPLY UNIT 10WL FAILED TEST. SECURED CANNON PLUG PER TSM 33-51-00-810-822-A.SDR DALA2020101203338Wire Harness · out of positionDURING INSPECTION FOUND LIFE RAFT CEILING LIGHT AT SEAT 4B HALF OUT. INSPECTED LIGHT ASSEMBLY, PER B737 AMM 33-22 AND FOUND WIRE HARNESS OBSTRUCTING LED STRIP. SECURED HARNESS AND RE-INSTALLED. OPERATIONS CHECK GOOD.SDR SIMA20201009002Wire · brokenSERVICE DOOR EMERGENCY LIGHT INOPERABLE. C/A: R & R SERVICE DOOR EMERGENCY LIGHT LAMP, IAW AMM 33-50-09-000-801-A AND 33-50-09-400-801-A, NO FIX. FOUND SERVICE DOOR EMERGENCY LIGHT BROKEN WIRE, IAW WM 30-50-50-001. NEEDS WIRE AND CONNECTOR DEFERRED DUE TO LSDR YENA2020101500488Connector · unsecureDURING HEAVY MAINTENANCE, CEILING EMERGENCY LIGHT LOCATED ABOVE ROW 18 INOPERABLE, REF FAS N/R 00040 WO N809JB-01-01. T/S CEILING EMERGENCY LIGHT ROW 18 FOUND CONNECTOR 205WL LOOSE. RECONNECTED AND SATISFACTORY OPERATIONS CHECK GOOD, IAW A320 WDM 33-51-02.SDR DALA2020100903316Wire · brokenDURING INSPECTION FOUND FOUND BROKEN WIRES ON AFT RED EGCY. R/R LIGHT ASSY IAW B737 AMM 33-52 OPS NORMAL.SDR VNAA2020100811102Connector · disconnectedINSPECTED AND FOUND BATTERY PACK NR 4 CONNECTOR DISCONNECTED. RECONNECTED CONNECTOR, IAW CRJ 900 AMM 33-51-17-400-802-A04. REINSTALLED CEILING PANEL, OPS CHECK GOOD, IAW AMM 33-51-00-710-802-A27 AND AMM 25-26-05-400-802-A39.SDR MASA2020100510591Connector · disconnectedMULTIPLE EMERGENCY LIGHTS INOPERABLE. MX RECONNECTED BATTERY PACK CONNECTOR.SDR SIMA20201002007Connector · missingNR 1 AND NR 2 EMERGENCY FLOOR LIGHT STRIPS ARE MISSING CONNECTORS ON A/C SIDE. C/A COMPLETE: INSTALLED NEW AND SERVICEABLE CONNECTORS AT NR 1 AND NR 2 EMERGENCY FLOOR LIGHT STRIPS ON A/C SIDE, IAW EMB 145 SWPM 20-21-00. SEE BOW347724 TASK NR 1 FOR OPERATIONASDR SIMA20201002005Connector · brokenNR 1 EMERGENCY LIGHT STRIP CONNECTOR ON A/C SIDE IS BROKEN. C/A COMPLETE: R & R NR 1 EMERGENCY LIGHT STRIP CONNECTOR ON A/C SIDE, IAW EMB 145 SWPM 20-21-00. INSTALLED NR 1 EMERGENCY LIGHT STRIP, IAW EMB 145 AMM 30-50-12. OPERATIONS CHECK GOOD, IAW EMB 145 ASDR CALA2020100701152Connector · brokenR1 DOOR EMERGENCY EXIT IDENTIFIER LIGHT (LOWER DOOR SURROUND) IS IN OP, INTERMITTENT {A3NB-33-3-6012} - GENERATED BY V061627 ON N/R 9296370 AT HAECO LCQ.SDR DALA2020092803225Wire Harness · damagedDURING INSPECTION FOUND EMERGENCY LIGHTS AT 36 DEF ARE INOPERATIVE. CORRECTIVE ACTION: REPLACED SEAT HARNESS AT 36 DEF. SYSTEM OPERATION IS NORMAL.SDR DALA2020092903224Diode · failedDURING INSPECTION FOUND EMERGENCY PATH LIGHTS AT ROWS 27-37 INOPERATIVE. CORRECTIVE ACTION: REPLACED THE DIODE AT PACK M10568. SYSTEM OPERATION IS NORMAL.SDR AALA202009299007Wire Harness · brokenAIRCRAFT WAS GROUNDED. FOUND ROW 11 ABC HARNESS FOR EMERGENCY EXIT LIGHT IN AISLE BROKEN. REMOVED AND REPLACED SET HARNESS, PER ESPM 20-33-50.SDR SWAA2020093018531Pin · recessedLEFT SIDE EMERGENCY AISLE LIGHT (L1085) INOP BETWEEN SEAT ROW 11 & 12. PERFORMED T/S, FOUND RECESSED PIN ON GD-3744. RESECURED PIN AND PERFORMED EMERGENCY LIGHTS OPS TEST. FOUND NORMAL AT LIGHT L1085 BETWEEN ROW 11 & ROW 12 LEFT SIDE, AS PER REF B737 AMM 33SDR DALA2020092803207Wire · disconnectedDURING INSPECTION FOUND EMERGENCY FLOOR LIGHTS AT SEAT 43 RIGHT SIDE INOPERATIVE. CORRECTIVE ACTION: FOUND DISCONNECTED WIRE SPLICE CONNECTOR BEHIND SIDEWALL PANEL AND CONNECTED. SYSTEM OPERATION IS NORMAL.SDR DALA2020092803179Wire · miswiredEMERGENCY DOME LIGHT INOPERABLE AT ROW 30. CORRECTIVE ACTION: INSPECTED AND FOUND CONNECTORS REVERSED, CORRECTED WIRES. OPERATIONS CHECK NORMAL, PER A321 AMM 33-51.SDR JJBA20200926006Wire · damagedEXTERNAL EMERGENCY LIGHT ON THE SERVICE DOOR INOPERATIVE. REPLACED EXTERNAL EMERGENCY LIGHT HOUSING ASSEMBLY ON THE SERVICE DOOR. INSTALLED NEW WIRE & CRIMPED SPLICE SP7376 & SOCKET FOR CONNECTOR P7198 C PORT. R & R CONNECTOR P7198 AND REPLACED WIRES FROM OSDR R61A2020092600645Wire · disconnectedWHILE A/C WAS OUT OF SERVICE FOR HEAVY CHECK EMERGENCY LIGHT ON FWD AX ENTRY CEILING PANEL INOP. TROUBLESHOOT EMERGENCY EXIT LIGHT INOP ON FWD LT ENTRANCE DOOR PANEL FOUND WIRE PULLED OUT OF CONNECTOR ON EMEGENCY LIGHT. RESEATED CONTACT AND WIRE, IAW EMB175 SDR AALA202009249014Connector · inoperativeAIRCRAFT WAS NOT GROUNDED: PASSENGER DOOR OPEN INDICATION ON LEFT FORWARD EMERGENCY EXIT ON DOOR PAGE. REMOVED AND REPLACED BOX CONNECTION FOR DEU AT L2 EMERGENCY EXIT DOOR, IAW AMM 23-73-47.SDR AALA202009219026Connector · unsecureAIRCRAFT WAS GROUNDED: EMERGENCY LIGHTS OUT ON SEATS 18C, 19C, 22C, 23C, 26C, 27C, ALL HAVE WIRING ISSUES. REPLACED EMERGENCY POWER SUPPLY UNIT (AALA202009209002) 13WL BATTERY PACK (AALA202009219025) AND SECURED CONNECTORS AT ROW 22C AND 23C. ALL NORMAL PER SDR AALA202009209001Wire · chafedAIRCRAFT WAS GROUNDED: FOUND EMERGENCY EXIT LIGHTING WIRES CHAFED AT ROW 19ABC, AT CONNECTOR 7260VC. REPAIRED CHAFED WIRING ON EMERGENCY LIGHT SYSTEM LOCATED AT SEAT ROW 19ABC.
Back to JASC 3397