JASC 3510
Service difficulty reports · 2,418
Reports filed under 3510 · Crew Oxygen System, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3510' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3510' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2014063091370Oxygen System · lowCREW OXYGEN SYS LOW. SERVICED CREW OXYGEN IAW AMM 12-14-35-0301. OPERATIONS & LEAK CHECKED OK. PRESS PRIOR TO SERVICING 1250PSI.SDR GTIA2014062601364Oxygen Mask · leakingFO'S OXYGEN MASK HAS A LOOSE SEAL. R & R F/O'S OXYGEN MASK IAW AMM 35-12-41, PB 401. OPS CHECKED GOOD.SDR USAA2014062700008Oxygen Bottle · low pressureCREW O2 PRESS AT 120 PSI. SERVICED CREW O2 TO 1500 PSI IAW AMM CHAPTER 20-3512 & INSTALLED BOTTLE IAW AMM 35-11-41-0401.SDR GTIA2014062401362Oxygen Mask · leakingF/O OXYGEN MASK EXPANDABLE HEAD STRAP LEAKING WHEN EXPANDING FOR USE. R & R F/O OXYGEN MASK IAW AMM 35-12-41. OPS CHECKED GOOD.SDR GTIA2014062401361Oxygen Mask · inoperativePRIMARY OBSERVER SEAT OXYGEN MASK INOPERATIVE. R & R PRIMARY OBSERVER SEAT OXYGEN MASK. OPS CHECK OK IAW AMM 35-12-41.SDR 2014FA0000395Shutoff Valve · misinstalledDURING INSTALLATION OF THE CREW OXYGEN BOTTLE AFTER HYDRO TEST, THE COCKPIT OXYGEN SHUTOFF CONTROL CABLE WAS CONNECTED TO THE BOTTLE WHEN THE SHUTOFF VALVE ASSY ON THE BOTTLE REGULATOR WAS ROTATED 180 DEGREES FROM THE CORRECT POSITION. THIS RESULTED IN THE BSDR CA140611003Bottle · leaking(CAN) FLIGHT CREW ADVISED COMPLETE DEPLETION OF FLIGHT CREW OXYGEN WHILE ENROUTE/OVER ICELAND. IN CONSULTATION WITH THE DUTY PILOT/FLEET MANAGER AND FLIGHT DISPATCH THE FLIGHT WAS RECOMMENDED TO CONTINUE AS LONG AS THE ACFT PRESSURIZATION WAS NORMAL AND THE SSDR GTIA2014061001338Oxygen Mask · no testFIRST OFFICER`S OXYGEN MASK WILL NOT TEST. R & R WITH SECOND OBSERVERS OXYGEN MASK, OPS OK IAW AMM 35-12-41.SDR GTIA2014061001337Oxygen Mask · malfunctionedF/O OXYGEN MASK CONTINUOUSLY RUNS. R & R OXYGEN MASK IAW AMM 35-12-41. OPS CHECKED GOOD.SDR CALA2014060991235Oxygen Mask · defectiveCAPTAIN'S OXYGEN HARNESS FAILS TO INFLATE, IS LEAKING. REPLACED CAPTAIN`S O2 MASK, OPERATIONS CHECKED OK.SDR GTIA2014060501335Tube · rupturedOBSERVER OXYGEN MASK HARNESS TUBING RUPTURED INSIDE FABRIC. R & R OBSERVER OXYGEN MASK IAW AMM 35-12-41. OPS CHECKED GOOD.SDR CALA2014060591206Oxygen Bottle · low pressureCREW O2 IS LOW 1510 PSI. SERVICED AS NEEDED CREW OXYGEN.SDR CALA2014060591209Oxygen Mask · faultyHOT MIC AT CAPTAIN`S BOOM. SUSPECT O2 MASK SYS. REINSTALL O2 MASK SYS & CHECK ALL PUSH TO TALK SWITCH. HOT MIC RETURN TO NORMAL.SDR AALA20140603025Regulator · defectivePHX CREW REPORTED OBSERVERS O2 BOTTLE COMPLETELY EMPTY. FLIGHT RETURNED PHX LANDED WITHOUT INCIDENT. REPLACED OBSERVERS O2 REGULATOR & O2 BOTTLE. SYS GND CHECKED NORMAL, OPERATION CLOSED.SDR USAA2014060400001Oxygen Bottle · leakingFLIGHT DIVERTED TO MIA DUE TO CREW O2 LEAKING DOWN TO 640 PSI INFLIGHT. REPLACED O2 BOTTLE IAW AMM 35-11-41 PB 0401. NO LEAKS NOTED.SDR GTIA2014053001326Oxygen Mask · damagedFIRST OBSERVERS OXYGEN MASK HAS HOLE IN HEAD BAND. R & R OXYGEN MASK ASSY IAW AMM 35-12-41.SDR CA140528002Elbow · leaking(CAN) DURING TROUBLESHOOTING A SLOW OXYGEN LEAK, IT WAS FOUND THAT FITTING, PN MS20822-5D THAT APPEARED TO BE LEAKING ON THE RT PILOTS O2 MASK STOW BOX. ONCE REMOVED, UPON INSPECTION THE FITTING APPEARS TO HAVE SOME SORT OF MANUFACTURING DEFECT. THE DEFECT DSDR GTIA2014052301310Oxygen Mask · inoperativeOBSERVERS OXYGEN MASK INOPERATIVE. R & R OBSERVERS OXYGEN MASK IAW AMM 35-12-41 PB 401. OPS CHECKED GOOD.SDR GTIA2014052301309Oxygen Mask · inoperativeF/O OXYGEN MASK WILL NOT TEST. INTERCHANGED F/O OXYGEN MASK WITH 1ST OBSERVER OXYGEN MASK IAW AMM 35-12-41-400-001-A. BOTH OXYGEN MASK OPS CHECKS GOOD.SDR N6WA20140522005Indication Sys · malfunctionedOXYGEN CAUTION MSG IN FLIGHT. DEFERRED FLIGHT OXYGEN PRESS INDICATION ON DMI, IAW MEL 35-12-01A CAT C.SDR GTIA2014051001298Oxygen Mask · inoperativePRIMARY OBSERVER'S OXYGEN MASK INOPERATIVE. R & R OXYGEN MASK IAW AMM 35-12-41-000-002-A/ 400-002-A. OPS CHECKED GOOD IAW AMM 35-12-41-710-001.SDR GTIA2014050801292Oxygen Mask · inoperativeCAPTAIN`S OXYGEN MASK HEAD STRAP HAS A BLOWN TUBE. STRAP WILL NOT INFLATE FULLY. R & R OXYGEN MASK IAW CMM 35-13-44. OP'S CHECKED GOOD. NO LEAKS NOTED.SDR GTIA2014050601290Oxygen Mask · looseFIRST OBSERVER`S SEAT OXYGEN MASK HAS LOOSE HARDWARE. R & R FIRST OBSERVER OXYGEN MASK IAW AMM 35-12-41. OPS CHECKED GOOD.SDR CALA2014050690961Unknown · faultyO2 SERVICED TO FULL IN DENVER, SHOWED 1500 AT DULLES. NOW SHOWING 1360 IN FLT. BOTTLE PRE-SERVICE READING WAS 1600 PSI, SERVICE TO 2000 PSI. COCKPIT INDICATION SHOWED 1900 PSI. CREW WILL MONITOR PRESS INFLIGHT.SDR GTIA2014050501289Oxygen Mask · inoperativeCAPTAINS OXYGEN MASK INOPERATIVE. R & R IAW AMM 35-12-41. OPS CHECKED GOOD.SDR GTIA2014041601259Oxygen Mask · inoperativeSECOND OBSERVERS, OXYGEN MASK INOPERATIVE. R & R OXYGEN MASK IAW AMM 35-12-41, OPS CHECKED GOOD.SDR 9JLA2014040907283Oxygen Mask · defectiveCREW REPORTED THAT THE CO-PILOTS O2 MASK DONNING BUTTON WOULD NOT WORK. FOUND CREW O2 MASK TO BE DEFECTIVE PN 174262-12, SN 01384. AN OVERHAULED CREW MASK WAS INSTALLED.SDR GTIA2014032901239Oxygen Mask · leakingF/O OXYGEN MASK HAS A LEAK IN HEAD STRAP TUBE. R & R OXYGEN MASK IAW MM 35-12-41-000-002 AND 35-12-41-400-002A AND 35-12-41-710-051A.SDR AALA20140322001Regulator · leakingPHX CREW REPORTED LOSS OF CREW OXYGEN PRESS. EMERGENCY DECLARED FLIGHT LANDED PHX WITHOUT INCIDENT. ACFT REMOVED FROM SERVICE. REPLACED CAPTAIN`S & FIRST OFFICER`S DEMAND REGULATORS THAT WERE LEAKING. SYS GND CHECKED NORMAL, OPERATION CLOSED.SDR GTIA2014031701223Oxygen Mask · leakingPRIMARY OBSERVER SEAT INOPERATIVE, OXYGEN MASK LEAKING. R & R OXYGEN MASK IAW AMM 35-12-41. OPS AND LEAK CHECKED GOOD.SDR GTIA2014031701222Oxygen Mask · malfunctionedF/O OXYGEN MASK WILL NOT STOP RUNNING. R & R OXYGEN MASK AND STOWAGE BOX IAW AMM 35-12-41-400-001-A/35-12-41-000-001-A. PERFORMED LEAK CHECKS. NO LEAKS NOTED.SDR USAA2014031800008Selector Knob · brokenRIGHT HAND FLIGHT DECK OBSERVER`S MASK EMERGENCY SELECTOR KNOB BROKEN. REPLACED FLIGHT DECK OBSERVER`S MASK IAW AMM 35-12-41.SDR USAA2014031800007Selector Knob · detachedFIRST OFFICER`S OXYGEN MASK EMERGENCY SELECTOR KNOB DETACHED. REPLACED FIRST OFFICER`S FWD OXYGEN MASK IAW AMM 35-12-41.SDR GTIA2014031701219Oxygen Mask · damagedFO OXYGEN MASK MISSING PLASTIC RIVET ON SIDE. R & R F/O OXYGEN MASK IAW AMM 35-12-41. OPS AND LEAK CHECKED OK.SDR GTIA2014031701218Oxygen Mask · inoperativeF/O OXYGEN MASK WILL NOT STOP RUNNING. R & R OXYGEN MASK AND STOWAGE BOX IAW AMM 35-12-41-400-001-A/35-12-41-000-001-A. PERFORMED LEAK CHECKS. NO LEAKS NOTED.SDR GTIA2014031401214Attach Fitting · damagedF/O OXYGEN MASK INTERNAL CLIPS THAT HOLDS ONE OF THE INFLATABLE HEAD STRAPS TO THE MASK IS MISSING. R & R F/O OXYGEN MASK IAW AMM 35-12-14, PB 401.SDR AALA20140313018Oxygen Bottle · defectiveMEM INFLIGHT ATL DFW. CREW REPORTED CREW OXYGEN BOTTLE PRESS DRAINED CONTINUOUSLY IN FLIGHT. FLIGHT DIVERTED MEM LANDED WITHOUT INCIDENT. REPLACED CREW O2 BOTTLE & LEAK CHECKED. SYS GND CHECKED NORMAL, OPERATION CLOSED.SDR ASMF201403015Oxygen Bottle · leakingAIRCRAFT RETURNED OF FLIGHT DUE TO DURING CRUISE, THE OXYGEN CYLINDER WITH 0 PSI IN THE CABIN CREW. AT TIJ, PERFORMED AN OXYGEN CREW INSPECTION IAW MM 35-12-85, DETECTING OXYGEN LEAK IN THE BOTTLE & THE MANOMETER WAS INDICATED 0 PSI, SO THE OXYGEN BOTTLE WAS SDR CALA2014030390509Actuator · faultyFWD FLIGHT ATTENDANT OXYGEN COMPARTMENT WILL NOT OPEN DURING MANUAL DROP TEST. REPLACED COMPARTMENT DOOR LATCH ACTUATOR.SDR ASMF201403006Oxygen Bottle · leakingAIRCRAFT PERFORMED AN UNSCHEDULED LANDING AT IAD DUE TO A LEAK ON CREW OXYGEN SYS. MX PERFORMED AN OXYGEN CREW INSPECTION IAW MM 35-12-85, DETECTING OXYGEN LEAK IN THE BOTTLE & THE MANOMETER WAS INDICATED 320 PSI. THE OXYGEN BOTTLE WAS REPLACED IAW AMM DMC-BSDR GTIA201402191181Oxygen Mask · leakingCAPTAIN O2 MASK HEADSTRAP LEAKS AND WILL NOT INFLATE. R & R FULL FACE QUICK DONNING IAW AMM. OPS CHECK GOOD.SDR GTIA201402161176Stowage Box · inoperativeNR 2 OBSERVER OXYGEN MASK INOPERATIVE. R & R NR 2 OBSERVER OXYGEN MASK IAW AMM. NO HELP. R & R NR 2 OBSERVER OXYGEN MASK STOWAGE BOX IAW AMM. OPS & LEAK CK GOOD.SDR GTIA201402121165Oxygen Mask · damagedCAPTAIN`S OXYGEN MASK PLASTIC STRAP THAT HOLDS, SECURES MASK BROKEN. R & R CAPTAIN'S OXYGEN MASK IAW AMM. OPS CHECKED GOOD.SDR AALA20140210008Regulator · faultySTL INFLIGHT DAY DFW CREW REPORTED CREW O2 BOTTLE EMPTY. FLIGHT DIVERTED STL LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. REPLACED ALL THREE O2 REGULATORS. SYS GND CHECKED NORMAL OPERATION CLOSED.SDR GTIA201402061153Oxygen Mask · leakingCAPTAIN`S OXYGEN MASK LEAKING AND WILL NOT SEAL PROPERLY. R & R SECOND OBSERVER`S OXYGEN MASK IAW AMM 35-12-41. OPS CK & LEAK CHECKED GOOD.SDR GTIA201402031149Oxygen Mask · inoperativeF/O OXYGEN MASK DOES NOT PROPERLY INFLATE. SWAPPED F/O'S OXYGEN MASK WITH PRIMARY OBSERVERS SEAT OXYGEN MASK. R & R FIRST OBSERVER OXYGEN FULL FACE MASK IAW AMM, OPS CHECKED GOOD.SDR CA140203024Oxygen Bottle · failed(CAN) PRIOR TO DEPARTURE, THE CREW REPORTED OBSERVING THE CREW OXYGEN LEVEL WAS READING 1660 PSI. AFTER DEPARTURE, DURING THE CLIMB AT 14,000 FT, THE EICAS MESSAGE OXY LOW PRESSURE" ILLUMINATED. AT THIS TIME THE CREW NOTICED THE CREW OXYGEN SUPPLY PRESSURE DRSDR GTIA201401271139Oxygen Mask · inoperativeF/O OXYGEN MASK INOPERATIVE, HOSE BECAME DETACHED FROM MASK DURING STOWAGE, OXYGEN FLOWS FREELY UNREGULATED. R & R F/O OXYGEN MASK IAW AMM. OPS CHECKED OK.SDR GTIA201401221130Oxygen Mask · brokenCAPTAIN'S OXYGEN MASK INFLATE HOSE BROKEN. REPLACED OXYGEN MASK IAW AMM, TESTED OK.SDR GTIA201401221129Oxygen Mask · brokenF/O OXYGEN MASK BROKEN. R & R OXYGEN MASK IAW AMM. OPS CHECKED GOOD
Back to JASC 3510