JASC 3510
Service difficulty reports · 2,418
Reports filed under 3510 · Crew Oxygen System, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3510' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3510' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2013092791523Oxygen Mask · inoperativeFIRST OFFICER`S OXYGEN MASK HAS LEAK & DOESN'T EXPAND FOR PROPER FIT AROUND HEAD. SWAPPED FIRST OFFICER`S WITH FIRST OBSERVER`S. FIRST OFFICERS` OPERATIONS CHECKED GOOD. DEFERRED STICKER FIRST OBSERVER`S SEAT INOPERATIVE. REPLACED FIRST OBSERVER`S MASK IAWSDR CALA2013092791522Oxygen Mask · inoperativeCAPTAIN`S 02 MASK INOPERATIVE, CAN HEAR SQUEAL FROM MIC.SDR CALA2013092591431Oxygen Box · faultyCAPTAIN`S 02 MASK INOPERATIVE, CAN HEAR SQUEAL FROM MIC. SWAPPED FIRST OBSERVER`S OXYGEN BOX WITH CAPTAINS, MIKE WORKS NORMALLY AT CAPTAIN'S POSITION. FIRST OBSERVER`S O2 MIKE INOPERATIVE, BUT O2 MASK OTHERWISE WORKS FOR O2. STICKER APPLIED IAW MEL 2511S. PSDR CALA2013092391358Test Switch · brokenFIRST OFFICER`S O2 DOOR PRESS TO TEST BUTTON IS BROKEN. REPLACED O2 STORAGE BOX.SDR CALA2013092391357Regulator · leakingCREW OXYGEN SYSTEM LOW. REPLACED O2 PRESSURE REGULATOR LEAKS CHECKED OK. NO DROP IN PRESSURE ON 20 MIN.SDR CALA2013091891286Oxygen Mask · failedSECOND OBSERVERS OXYGEN MASK FAILED TEST.SDR GTIA20130914967Oxygen Mask · inoperativeOBS OXYGEN MASK INOPERATIVE. R & R OBSERVERS SEAT OXYGEN MASK IAW AMM 35-12-41, PB 401, OXYGEN MASK TESTED NORMAL.SDR CA130918013Oxygen Mask · damaged(CAN) DURING EMERGENCY DECENT THE CAPTAIN USED THE OXYGEN MASK. DURING THE REMOVAL OF THE MASK FROM THE STOWED POSITION, THE HARNESS INFLATION CENTRAL VALVE & OXYGEN SUPPLY CONTROL KNOB SEPARATED FROM THE MASK. THIS LEFT THE MASK HARNESS CONTINUALLY INFLATESDR CALA2013091191200Oxygen Mask · faultyFO CREW O2 MASK IN TEST POSITION 02 FLOWS LONGER THAN NORMAL. SWAPPED MASKS WITH O2 MASK FROM SECOND OBSERVER'S SEAT. ACCORDINGLY SECOND OBSERVER'S SEAT RENDERED INOPERATIVE, NOT TO BE OCCUPIED. REPLACED O2 MASK, SLIDING OBSERVER`S SEAT RETURNED TO SERVICE.SDR CALA2013090691070Oxygen System · damagedCAPTAIN'S O2 MASK BOX DAMAGED. REPLACED CAPTAIN'S O2 BOX IAW.SDR CALA2013090691068Oxygen Mask · defectiveFIRST OFFICER'S OXYGEN MASK MICROPHONE IS INOPERATIVE. FOUND FIRST OFFICER'S CREW O2 MASK AT FAULT. REPLACED SAME IAW AMM. OPERATIONS CHECKED NORMAL.SDR CALA2013090290943Harness · defectiveCAPTAIN'S OXYGEN HARNESS FAILS TO INFLATE. SWAPPED WITH 2ND OBSERVERS SEAT, CAPTAIN'S WORKS.SDR CALA2013090290935Mechanism · looseCAPTAIN`S 02 MASKS INSIDE BOX LT SIDE SLIDE MECHANISM LOOSE DOES NOT ALLOW PROPER STOWAGE. STOWED CAPTAIN`S O2 MASK CHECKED GOOD.SDR CALA2013082990821Oxygen Mask · leakingCAPTAINS OXYGEN MASK FOUND LEAKING ON ARRIVAL INTO ORD FLIGHT 354-26, COULD HEAR AUDIBLE LEAK WITH OXYGEN ON. REPLACED CAPTAINS OXYGEN MASK & OXYGEN BOX. AFTER MASK & BOX REPLACED LT OXYGEN ON & NO PRESSURE DROP IN 3 HOURS..SDR AALA20130826023Hose · crackedSLC INFLIGHT PDX-DFW CREW REPORTED COCKPIT O2 BOTTLE FOUND LEAKING IN FLIGHT. FLIGHT DIVERTED SLC LANDED WITHOUT INCIDENT. REPLACED REGULATOR SUPPLY HOSE. SYSTEM GROUND CHECKED NORMAL OPERATION CLOSED.SDR CALA2013082790785Oxygen Mask · leakingTHE CAPTAINS O2 MASK HARNESS SECURING HOSE HAS AIR LEAK. SWAPPED O2 MASK WITH 1ST OBSERVERS SEAT. 1ST OBSERVERS SEAT INOPERATIVE IAW MEL. CAPTAIN'S MASK OPERATION CHECKED. PN 649-0148, REPLACED 1ST OBSERVERS MASK ASSEMBLY.SDR GTIA20130826940Bracket · brokenPRIMARY OBSERVER OXYGEN MASK INOPERATIVE DUE TO BROKEN BRACKET.SDR GTIA20130824937Oxygen Mask · faultyCAPTAIN`S OXYGEN MASK WILL NOT INFLATE FULLY. R & R OXYGEN MASK. OPS CHECKED OK IAW AMM.SDR YYFA20130824001Oxygen Mask · inoperativeCAPTAIN'S OXYGEN MASK IS INOPERATIVE.SDR CALA2013082090598Receptacle · damagedFOUND CREW OXYGEN SYSTEM FILL PORT DAMAGED. REPLACED CREW O2 FILL PORT PER MM, OK FOR SERVICE.SDR CALA2013081990540Oxygen Bottle · low pressureOXYGEN LOW READS BELOW PILOT FLT MANUAL LIMIT, SERVICE O2 TO 1470.SDR REXA2013080601561Oxygen Mask · no testF/O SIDE OXYGEN MASK WILL NOT TEST. STOWED F/O OXYGEN MASK. OPS CHECKED GOOD IAW AMM 35-11-12. OK FOR SERVICE.SDR GTIA20130806414Oxygen Mask · inoperativeF/O O2 MASK INOPERATIVE. PERFORMED OPS TEST OF THE FULL FACE/QUICK DONNING O2 MASK IAW AMM. OPS CHECKED GOOD.SDR GTIA20130803408Oxygen Mask · chatteringF/O’S OXYGEN MASK, WHEN INHALING, DOES NOT FLOW SMOOTHLY, IT CHATTERS. R & R F/O O2 MASK IAW AMM 35-12-41-000-001-A AND 35-12-410-001-A. OPS CHECKED GOOD.SDR GTIA20130729406Oxygen Mask · brokenF/O OXYGEN MASK HEADBAND BROKEN. R & R MASK ASSY IAW MM 35-12-40-000-002-A & 35-12-41-400-002-A. OPS CHECKED GOOD.SDR CALA2013073090097Oxygen System · low pressureCOCKPIT O2 PRESSURE GETTING LOW, 1250 PSI. SERVICED CREW O2 IAW AMM 12-15-08.SDR CALA2013072990031Oxygen Mask · leakingSECONED OBSERVER`S, O2 HARNESS LEAKING. R & R MASK IAW MM LEAK AND OPS CHECKED GOOD. ACFT OK FOR SERVICE.SDR CALA2013073090068Oxygen Mask · leakingCAPTAIN'S OXYGEN HARNESS FAILS TO INFLATE (LEAKING). RT RELEASE LEVER ON CAPTS O2 MASK BROKE OFF. CONT O2 FLOW UNLESS LT DOOR CLOSED AND SYS IS RESET. REPLACED CAPTS O2 MASK.SDR REXA2013072601383Oxygen Mask · no testCAPTAIN`S O2 MASK FREE FLOWS DURING O2 MASK TEST OR WHEN LIFT PANEL OPEN. MUST PUSH TO TEST/REST TO GET TO STOP. CHECKED & REPLACED O2 MASK IAW AMM 35-11-12. OPS CHECKED GOOD.SDR CALA2013072990039Solenoid Valve · failedLOW PRESSURE OXYGEN INDICATION FAILED TEST IAW 2SVC REQUIREMENT. REMOVED LP O2 SUPPLY SOLENOID VALVE IAW AMM. REPLACEMENT PART DAMAGED AWAITING NEW VALVE. INSTALLED NEW SOLENOID VALVE IAW MM, VALVE TESTS OK.SDR CA140728014Bottle · faulty(CAN) BA RECEIVED A DISCLOSURE LETTER ON THE 25TH OF JULY 2013, STATING THAT DUE TO A QUALITY ESCAPE, THE CREW OXYGEN BOTTLE IS PRONE TO DISCHARGE PREMATURELY. THE ACTUATION OF BURST DISC COULD ACTUALLY OCCUR AT NORMAL BOTTLE OPERATING PRESSURE AND TEMPERATURESDR UALA2013072605251Oxygen Bottle · low pressureCREW OXYGEN SYS LOW. SERVICED CREW OXYGEN BOTTLE TO FULL.SDR CA130807003Regulator · failed(CAN) FLIGHT CREW ATTEMPTED TO USE THE PORTABLE FIRST AID OXYGEN BOTTLE BUT COULD NOT GET ANY FLOW FROM IT. PRIOR TO SENDING TO VENDOR, MAINTENANCE PERSONNEL FOUND THAT THE OXYGEN APPEARED TO BE FULLY SERVICED AND THE OXYGEN PRESSURE INDICATOR WAS WORKING CORSDR UALA2013072305182Oxygen Mask · no testCAPTAIN'S FWD O2 MASK WILL NOT TEST PROPERLY. AIR WILL KEEP FLOWING WHEN MASK SWITCH IS PUT IN EMERGENCY POSITION. REPLACED MASK, OPS CHECKED OK.SDR CA130726002Disc · ruptured(CAN) THE OXYGEN CYLINDER SAFETY OUTLET ASSEMBLY CONTAINS SAFETY DISC THAT HAS RUPTURED ON FEW UNITS AT PARTS LOGISTICS FACILITY TEARDOWN ANALYSIS REVEALED BY THE SUPPLIER DICTATES 2 SPACERS WERE RESURFACED. FROM MAY 1, 2013 TO JULY 1, 2013, 25 SPACERS WERE RSDR GTIA20130718394Oxygen Mask · inoperativeOBSERVER O2 MASK BROKEN. R & R MASK IAW MM. OPS CHECKED GOOD.SDR UALA2013071905076Line · leakingCREW OXYGEN SYSTEM LOW. O2 SYS SERVICED TO1550 PSI. 2 HOURS 40 MINUTES INTO FLT PRESSURE 1370. SUSPECT SYS LEAK, FOUND O2 LINE FROM LT SIDE TEE FITTING LEAKING AT CAPTAIN`S O2 BOX, LINE HAD BADLY CRUSHED WASHER, R & R LINE, SERVICED O2 TO 1900 PSI AND O2 HESDR REXA2013071601373Stowage Box · failedF/O OXYGEN MASK WOULD NOT TEST PROPERLY WITH PRESS TO TEST. THERE IS NOT A CATS EYE. R & R F/O O2 STOWAGE BOX IAW AMM 35-11-15.SDR REXA2013071601368Stowage Box · no testF/O OXYGEN MASK WOULD NOT TEST PROPERLY WHEN PRESS TO TEST THERE IS NO CATS EYE. R & R F/O O2 STOWAGE BOX IAW 2 AMM 35-11-15.SDR GTIA20130715388Oxygen Mask · inoperativeLEFT OBSERVER OXYGEN MASK TEST LEVER BROKEN. R & R MASK IAW AMM. OPS CHECKED GOOD.SDR UALA2013071504953Warning Light · illuminatedOXYGEN EICAS PRESSURE READING 1190 PSI. SERVICED OXYGEN, OPS CHECKED NORMAL.SDR UALA2013071504942Oxygen Mask · failedCAPTAIN`S OXYGEN MASK SUPPLY IS RESTRICTED. INSTALLED NEW MASK, OPS CHECKED OK.SDR REXA2013071101346Stowage Box · no testCREW REPORTED CAPTAIN`S OXYGEN MASK BOX DOES NOT TEST PROPERLY. REPLACED CAPTAINS OXYGEN MASK BOX REF AMM 35-11-15. ALL CHECKED GOOD.SDR USAA2013071200002Oxygen Mask · leakingINFLIGHT LOSS OF O2 (CREW) LANDED WITH 375 PSI. SERVICED. MX FOUND CAPT O2 MASK LEAKING. SWAPPED TO FIRST OBSERVER SEAT. REMOVED, SERVICED AND REINSTALLED CREW O2 BOTTLE. LEAK CHECK CARRIED OUT. NO FAULTS, ACFT OK FOR CONTINUED SERVICE. CAPTAIN'S MASK REMOSDR UALA2013071204882Oxygen Bottle · low pressureCREW OXYGEN PRESSURE READS 1400 PSI ON LOWER EICAS. REPLACED WITH NEW CREW OXYGEN BOTTLE AND PRESSURE & LEAK CHECKED OK.SDR UALA2013070904788Oxygen System · low pressureOXYGEN PRESSURE LOW. 950 PSI. SERVICED CREW OXYTEN SYSTEM IAW AMM.SDR UALA2013070904778Oxygen Bottle · low pressureCOCKPIT OXYGEN BOTTLE HAS LOW PRESSURE. SERVICED CREW OXYGEN BLTTLE IAW AMM 12-14-35.SDR REXA2013070301329Stowage Box · failedCAPTAIN OXYGEN MASK CAN'T GET YELLOW STAR WITH TEST. R & R OXYGEN STOWAGE BOX IAW AMM 35-11-15. LEAK & OPS CHECKED GOOD.SDR UALA2013070304663Oxygen Box · no testCAPTAIN`S OXYGEN BOX WILL NOT TEST. REPLACED OXYGEN BOX, OPS CHECKED GOOD IAW MM.SDR UALA2013070104580Solenoid Valve · faultyREGULATE LOW PRESSURE DISPLAYED ON DOOR-OXY SYS ECAM PAGE -DOOR-OXY. REPLACED LP OXYGEN SUPPLY SOLENOID VALVE.
Back to JASC 3510