JASC 3510
Service difficulty reports · 2,419
Reports filed under 3510 · Crew Oxygen System, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3510' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3510' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2012103106281Oxygen Bottle · low pressureCREW OXYGEN SYSTEM LOW. REMOVED CREW O2 BOTTLE AND SERVICED TO 1500 PSI. REINSTALLED CREW O2 BOTTLE, NO LEAKS NOTED.SDR UALA2012103106269Stowage Box · defectiveCAPT O2 MASK TEST FUNCTION INOP. REPLACED O2 MASK STOWAGE BOX, TESTS OKAY.SDR UALA2012103006251Oxygen Mask · inoperativeCAPTAIN'S O2 MASK INOPERATIVE. REPLACED CAPT O2 MASK PER MM. NEW MASK OPS CHECKS GOOD.SDR UALA2012102906235Oxygen Mask · faultyF/O OXY MASK HOT MIKE WHEN MASK SELECTED. SFOMM..ACTUALLY CONTINUOUS STUCK MIC ON F/O'S SIDE WITH ANY MIC AND ANY PTT SWITCH PUSHED. SWAPPED AUD SEL PANEL AND AUD ACCESS UNIT, NO HELP. DISCONNECTED GLARESHIELD PTT SWITCH NO HELP. ALL EQUIP RECONNECTED AND SDR AALA20121030001Oxygen Mask · unserviceableDFW - INFLIGHT MIA-LAS. CREW REPORTED FIRST OFFICER OXYGEN MASK UNUSABLE. FLIGHT DIVERTED DFW LANDED WITHOUT INCIDENT. REPLACED FIRST OFFICER O2 MASK ASSEMBLY. SYSTEM GROUND CHECK NORMAL OPERATION.SDR UIEA2012102500495Regulator · leakingWHILE LEAK CHECKING CREW OXYGEN CYLINDER REPLACEMENT, FOUND LEAK AT OXYGEN REGULATOR. R & R CREW O2 REGULATOR, TRANSDUCER ASSY IAW AMM 35-11-03, OPS ; LEAK CHECK GOOD.SDR UALA2012102306069Regulator · leakingOXY PRESS READING DROPS TO ZERO DURING OXY TEST THEN GRADUALLY RESTORES TO PRE-TEST READING. REPLACED BOTTLE REGULATOR PER AMM 35-11-03 AND O2 PRESSURE TRANSDUCER PER AMM. LEAK CHECKS GOOD AND TEST NORMAL.SDR UALA2012102206045Oxygen Mask · brokenF/O O2 MASK INOP RED INFLATE BROKEN. SWAPPED F/O MASK FOR FIRST OBSEVERS MASK. FIRST OBSERVERS SEAT NOT TO BE OCCUPIED. BROKEN MASK INSTALLED IN OXYGEN COMPARTMENT BUT NOT HOOKED UP DUE TO MASK LEAKING. REPLACED O2 MASK AT FIRST OBSERVER POSITION PER AMM. SDR CALA2012101700678Oxygen Mask · disconnectedCAPTAIN`S O2 MASK CAME DETACHED FROM HOSE WHILE STOWING MASK AFTER USE. CREW OXY PRESSURE DEPLEATED. HOSE TIED IN KNOT TO PREVENT COMPLETE LOSS. R & R CAPTAIN`S O2 MASK WITH SERVICEABLE ASSY. O2 MASK AND MIC CHECKED NORMAL. CREW O2 SERVICED.SDR UALA2012101705916Oxygen Mask · leakingF/O'S OXYGEN HARNESS FAILS TO INFLATE (IS LEAKING). REPLACED F/O O2 MASK PER AMM.SDR UALA2012101205815Oxygen Bottle · low pressureCREW OXYGEN SYSTEM-LOW. RECORD PRESSURE PRIOR TO SERVICING. CONFIRMED PRESS DOWN TO APPROX 980 PSI. REMOVED AND SERVICED CREW BOTTLE PER AMM. OPS AND LEAK CHECKS GOOD. SAFETIED VALVE OPEN AFTER BOTTLE RE-INSTALLED.SDR UALA2012100805709Oxygen Mask · faultyF/O O2 MASK PRESS TO TEST 100 PERCENT BUTTON BROKE. REPLACED 1ST OFFICER'S O2 MASK, OPS CHECKS OKAY.SDR UALA2012101005776Oxygen Mask · defectiveFLIGHT DECK OBSERVER O2 MASK IS DEFECTIVE. REPLACED O2 MASK. REMOVED AND INSTALLED PER AMM.SDR FDEA201209253425Oxygen Mask · failedCAPTAIN'S PRESS TO TEST AND RESET LEVER ON O2 BOX FAILS TO GIVE PROPER TEST NR O2 FLOW OR INTERMITTENT FLOW TO IRIS. SWAPPED CAPTAIN'S AND NR 2 COURIER O2 MASK BOX ASSY'S IAW MM 35-11-51-4-99. CAPTAINS O2 MASK TESTED GOOD. REMOVED AND REPLACED MASK ANSDR USAA2012092500024Oxygen Mask · defectiveFIRST OFFICER'S OXYGEN MASK HEADSTRAP IS INOPERATIVE. REMOVED AND REPLACED FIRST OFFICER'S O2 MASK IAW AIRBUS MAINTENANCE MANUAL 35-12-41-400-002.SDR FDEA201209203362Oxygen Mask · failedSECOND OBSERVER OXYGEN MASK FAILED PREFLIGHT CHECK. THE FLOW INDICATOR SHOWED RED DURING TEST. REPLACED SECOND OBSERVER`S OXYGEN MASK, OP CHECKED NORMAL IAW 35-12-000-4.SDR USAA2012091900008Oxygen Mask · brokenCAPTAIN'S BOOM MIC TRANSMITS WEAK. FOUND MASK HAS STUCK MICROPHONE. REMOVED AND REPLACED CAPTAIN'S MASK IAW AIRBUS MAINTENANCE MANUAL 35-12-41.SDR UALA2012091905304Fill Port · strippedCREW O2 BOTTLE FILL PORT HAS STRIPPED THREADS. REPLACED FILL PORT.SDR E81R2012091600001Harness · mismanufacturedCOPILOT NOTED QUICK-DONNING CREW MASK HEAD HARNESS ORIENTED UPSIDE DOWN COMPARED TO PILOT'S O2 MASK WHEN TEST FITTED. MASK FUNCTIONS OK, AND HEAD HARNESS COULD BE RE-ORIENTED TO FIT, BUT CONNECTIONS WOULD FACE AWAY FROM MASK BODY INSTEAD OF TOWARDS MASK BODY.SDR UALA2012091705246Oxygen Box · defectiveCAPTAIN'S OXYGEN HARNESS FAILS TO INFLATE (IS LEAKING). REPLACED O2 BOX, OPS CHECK GOOD.SDR UALA2012091305185Oxygen Bottle · dischargedCOCKPIT OXYGEN READS 0 PSI. PERFORMED LEAK TEST OF O2 SYSTEM NO LEAKS NOTED. SUSPECT COCKPIT MASK BUTTON STUCK. REMOVED AND REPLACED COCKPIT OXYGEN BOTTLE. P/N 'OFF' 801307-00 MR35219.SDR UALA2012090605039Oxygen System · low pressureCOCKPIT OXYGEN QTY LOW NEEDS SERVICING. SERVICED COCKPIT O2.SDR UALA2012083004881Oxygen Bottle · leakingCREW OXYGEN PRESSURE DECREASING. APPARENT LEAK. REPLACED CREW O2 BOTTLE PER MM. PERFORMED LEAK CHECK OF CREW MASKS AND CREW O2 BOTTLE. NO LEAKS NOTED. OK TO CONTINUE.SDR REXA0829201201297Smoke Goggles · missingOBSERVER SEAT SMOKE GOGGLES MISSING. REPLACED SMOKE GOGGLES IAW AMM 35-10-00.SDR USAA2012082400013Stowage Box · defectiveCAPTAIN'S OXYGEN MASK INTERMITTENTLY WILL NOT TEST - RED EMERGENCY BUTTON APPEARS WORN OUT. REMOVED AND REPLACED CREW OXYGEN MASK STORAGE BOX IAW AIRBUS MAINTENANCE MANUAL 35-12-41.SDR UALA2012082004597Valve · misriggedWHILE SERVICING CREW O-2 FOUND INDICATION ERRONEOUS BETWEEN FLT DECK AND BOTTLE, ALSO MAIN BOTTLE WON'T FILL TO FULL. FOUND O-2 BOTTLE VALVE SAFETIED TO OFF POSITION, OPENED VALVE AND SERVICED BOTTLE TO FULL, ALL INDICATIONS NORMAL.SDR UALA2012081604569Oxygen Mask · leakingCOCKPIT OXYGEN BOTTLE - LOW. PRESSURE SLOWLY DROPPING. MAY HAVE A SLOW LEAK MAINT TEXT: AIRCRAFT ARRIVED WITH CREW OXYGEN PRESS AT 270 PSI. REPLACED FIRST OFFICERS MASK ASSY THAT WAS LEAKING AND SERVICED CREW BOTTLE TO 1730 PSI. NO LEAKAGE NOTED.SDR UALA2012081604552Oxygen Mask · damagedFIRST OFFICERS O2 MASK PRESS TO TEST SWITCH STICKS ON AND O2 CONTINUES TO FLOW. REMOVED AND REPLACED FIRST OFFICER 02 MASK AS PER MM, OPS CHECKED GOOD.SDR UALA2012081304486Oxygen Mask · leakingFIRST OFFICERS OXYGEN HARNESS IS LEAKING AND FAILS TO INFLATE. BLADDER RUPTURED. REPLACED OXYGEN MASK, OPS CHECKED GOOD.SDR UALA2012080904330Stowage Box · leakingCAPT OXYGEN MASK STOW BOX LEAKING FROM RESET VALVE. SUPPLEMENTAL DATA UPDATE, REPLACED CAPTAINS O2 MASK STOWAGE BOX PER MM. LEAK AND OPS CHECKS GOOD.SDR USAA2012081300021Oxygen Mask · out of adjustFIRST OFFICER'S OXYGEN MASK EMERGENCY PRESSURE SELECTOR WILL NOT TEST - NO AIR FLOW. MAINTENANCE ADJUSTED MASK IN BOX. PRESS-TO-TEST WORKS NORMAL WITH AIRFLOW AND TEST INDICATION FUNCTIONS NORMAL.SDR UALA2012080904335Stowage Box · malfunctionedCAP O2 MASK NOT OPERATING PROPERLY. REMOVED AND REPLACED CAPTAIN'S O2 MASK STOWAGE BOX, OPS OK.SDR AALA20120729004Oxygen Bottle · low pressureCREW O2 BOTTLE BELOW LIMITS. REMOVED AND REPLACED CREW O2 BOTTLE. OPS CHECK NORMAL.SDR UALA2012072704074Hose · defectiveOXYGEN MASK HOSE DEFECTIVE AT2 (1=CAPT, 2=1ST OF, 3= 1ST OBS). FIRST OFFICER OXYGEN HOSE AROUND HEAD POPPED WHEN DONNED AND DOESN'T HOLD AIR. REPLACED MASK ASSY.SDR USAA2012072600011Smoke Hood · missingSMOKE MASK MISSING FROM AIRCRAFT. INSTALLED SMOKE MASK.SDR UALA2012071703848Oxygen Mask · failedFIRST OFFICERS OXYGEN MASK DOES NOT REPRESSURIZE AFTER SELF TEST. REPLACED FIRST OFFICERS OXYGEN MASK STOWAGE BOX, LEAK CHECKED GOOD. OPS CHECKED NORMALSDR UALA2012070503607Oxygen Mask · leakingFIRST OFFICERS OXYGEN HARNESS FAILS TO INFLATE AND IS LEAKING. REPLACED 2ND OBSERVER MASK ASSY.SDR UALA2012070303558Oxygen Mask · brokenRT CREW O2 AFT MASK HAS CONTROL SLIDE BROKEN. REMOVED AND REPLACED RT CREW AFT O2 MASK IAW MM ON TASK CARD 5121N0002.SDR UIEA2012070300294Stowage Box · damagedCREW OXYGEN WAS FOUND TO BE LOW. ON INSPECTION AND LEAK CHECK AFTER BOTTLE REPLACEMENT IAW AMM 12-15-08, THE CAPTAIN'S OXYGEN MASK STOWAGE BOX WAS FOUND TO BE DAMAGED AND LEAKING. THE CAPTAIN'S OXYGEN MASK STOWAGE BOX WAS REPLACED IAW AMM 35-11-18. LEAK AND SDR UALA2012070303560Oxygen Mask · defectiveCAPTAINS O2 MASK DEFECTIVE. REMOVED AND REPLACED O2 MASK, OPS GOOD.SDR UALA2012070303556Oxygen Mask · damagedRT CREW O2 AFT MASK HAS CONTROL SLIDE BROKEN. REPLACED RT AFT CREW O2 MASK PER AMM 35-12-41 ON PEMCO NR 5121N00021.SDR DALA1239829002O2 Generator · misinstalledDURING A PSV-Q CHECK, AFT FLIGHT ATTENDANT OXYGEN GENERATOR AT THE LEFT SERVICE DOOR AND THE AFT FLIGHT ATTENDANT CEILING MOUNTED OXYGEN GENERATOR WERE FOUND WITH THE SAFETY CAPS INSTALLED. REMOVED THE SAFETY CAPS.SDR 9JLA2012071704285Oxygen Mask · leakingTHE CREW REPORTED THAT DURING THE POST FLIGHT CHECKS IT WAS NOTED THAT THE PILOTS QUICK DONNING OXYGEN MASK WAS LEAKING, REMOVED THE PILOTS MASK PN 9914067-41, SN 10647. INSTALLED AN O/H MASK. FUNCTIONAL CHECKS SATISFACTORY.SDR UALA2012062203332Oxygen Mask · no testF/O O2 MASK WILL NOT TEST PROPERLY. REPLACED F/O MASK ASSY.SDR UALA2012061503289Stowage Box · defectiveON TAXI IN - CREW O2 PRESS WENT TO ZERO. REPLACED FIRST OFF O2 STOWAGE BOX ASSY PER AMM, OPS CHECKS NORMAL.SDR UG8A201206190001Oxygen Mask · separatedDURING A DECLARED EMERGENCY FOR SMOKE AND HEAT IN COCKPIT, THE PILOT OXYGEN MASK BROKE UPON DEPLOYMENT. IT APPEARS THE MASK WAS DEFECTIVE. IT WAS IN DUE O/H BY THE END OF JUNE 2012. THE MASK WAS REPLACED AND THE ACFT WAS RETURNED TO SERVICE.SDR ZKFR20120605001Check Valve · leakingOXYGEN SYS NON-RETURN VALVE LEAKING ALLOWING OXYGEN TO FLOW BACKWARDS AND LEAK OUT OF FILLER PORT. THIS WAS A BRAND NEW CHECK VALVE FROM MFG. REMOVED AND REPLACED UNIT.SDR ZKFR20120530001Check Valve · leakingOXYGEN SYSTEM LEAKING: FOUND OXYGEN SYSTEM NON-RETURN VALVE INOP AND ALLOWING OXYGEN TO FLOW BACKWARDS AND LEAKING OUT OF FILLER PORT. REMOVED AND REPLACED NON-RETUEN VALVE AND LEAK CHECKED GOOD. THIS NON RETURN VALVE WAS JUST INSTALLED 9 MONTHS AGO FOR THSDR UALA2012051802813Regulator · leakingF/D CREW O2 LEAK, FLIGHT DIVERTED. CREW REPORTED O2 LEAKING DOWN TO 410 PSI FROM 1250 PSI IN 3 HRS FLT TIME. REPLACED PRESSURE REGULATOR, O2 HOLDS STEADY.SDR DALA1518440175Flex Hose · unknownCREW OXYGEN SYSTEM HAS LOW PRESSURE, FLEX HOSE REPAIRED IAW EA 01-074935-03.
Back to JASC 3510