JASC 3510
Service difficulty reports · 2,419
Reports filed under 3510 · Crew Oxygen System, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3510' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3510' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UPS06546701Oxygen Mask · unknownINSPECTION TYPE:P1 REMOVE OXYGEN MASK, REPLACE WITH SERVICEABLE MASK. REMOVED AND REPLACED PER T/C 35-003-01.SDR UPS06546700Oxygen Mask · unknownINSPECTION TYPE:P1 REMOVE OXYGEN MASK, REPLACE WITH SERVICEABLE OXYGEN MASK. REPLACED MASK PER TC 35-003-01.SDR UPS06M46696Oxygen Mask · damagedINSPECTION TYPE: PS3 FIRST OFFICERS O2 MASK BUTTON IS MISSING PARTS RE-INSERTED TOP CAP ON FIRST OFFICER O2 MASK BUTTON AS REQUIRED.SDR F3LA200600015Stowage Box · no testDURING C-3 CHECK, CAPTAINS O2 MASK FAILED PRESS-TO-TEST. REPLACED CAPTAINS O2 BOX ASSY PER AMM 35-12-41-000-001, 35-12-41-406-001 AND 35-12-41-710-001. OPS CHECKED GOOD.SDR MASA200600918Oxygen Mask · unwanted deployASH 5068 CLT - AFT LAV O2 MASK DEPLOYED. MAINTENANCE RESECURED MASK.SDR MASA200600784Oxygen Mask · unwanted deployASH 7379 ORD - PAX OXYGEN MASK FELL FROM THE CEILING WHILE TAXING. MX SECURED THE MASK.SDR UPS06146418Oxygen Mask · no testCAPT'S 02 MASK W/NOT TEST. REMOVED AND REPLACED CAPT QUICK DONNING 02 MASK AND PLACED W/SERVICEABLE 02 MASK IAW A300-680 AMM 35-12-54-4.SDR F06027Oxygen Mask · deployedTHE CREW REPORTED AN O2 MASK IN THE CABIN HAD FALLEN. CONTRACT MAINTENANCE STOWED THE MASK.SDR MASA200600595Oxygen Mask · deployedASH 7146 DAB - LAVATORY OXYGEN MASK DEPLOYED IN FLIGHT. MX INSPECTED AND REPACKED THE MASK ASSEMBLY.SDR UPS06546302Oxygen Mask · leakingINSPECTION TYPE:N/A 1ST OBS O2 MASK SUPPLY HOSE LEAKING AT MASK CONNECTOR. REMOVED AND REPLACED MASK LEAK CHECK NORMAL.SDR AWXA200600355Oxygen Mask · leakingCREW REPORTED THAT THE O2 MASK LEAKED WHEN OXYGEN TURNED ON FOR USE. CREW DEFERRED PORTABLE OXYGEN UNIT. MAINTENANCE REPLACED MASK AND CLEARED MEL.SDR AWXA200600357Oxygen Mask · failedMCI - FLT 15 - DURING FLIGHT, EN ROUTE TO PHX FROM JFK, CREW REPORTED THAT THE CAPTAINS OXYGEN MASK INFLATE TUBE BROKE. CREW DIVERTED TO MCI AND LANDED WITHOUT FURTHER EVENT. MAINTENANCE SWAPPED CAPTAINS O2 MASK WITH SECOND OBSERVERS MASK AND MEL'D THE SECONSDR UPS06M46206Indicator · reads lowINSPECTION TYPE:PS2, THE CREW O2 BOTTLE NR 3 READS APPROX 200 PSI LOWER AT THE BOTTLE THAN AT THE REMOTE FLIGHT DECK INDICATOR. THE LIMIT IS 150 PSI DIFFERENCE ACCORDING TO TASK CARD NR 0102. REMOVED AND REPLACED FLIGHT DECK REMOTE O2 IND IAW M/M 35-14-02. SDR UPS06M46205Indicator · reads lowINSPECTION TYPE:PS2, THE CREW O2 BOTTLE NR 4 IS LOW PRESS AT THE BOTTLE AND READS APPROX 200 PSI LESS THAN THE REMOTE FLIGHT DEAC INDICATOR, LIMIT IS 150PSI DIFFERENCE). REMOVED AND REPLACED NR 4 O2 BOTTLE IAW MM CH 35-11-01. REPLACED COCKPI T O2 INDICATOR ISDR 2006FA0000249Gasket · leakingPILOT O2 MASK HAD ORIGINAL O/H DATE OF 6/05. MASK WAS PLACED IN SERVICE IN AC 55093. MASK DID NOT TEST PROPERLY AT DELIVERY DATE OF 6/23/05. MASK WAS SENT BACK, FOUND TO HAVE A LEAK. MASK WAS REPAIRED AND SENT BACK TO AC. MASK WAS FOUND TO BE LEAKING AGAISDR UPS06146181Oxygen Mask · no testFO'S 02 MASK W/N TEST. RESEATED FO'S 02 MASK CONNECTOR. OPS NORMAL IAW MM 35-12-51-5.SDR WX0600012Control Box · malfunctionedLAS - DLH - CREW REPORTED THE FIRST OFFICERS TRANSMITTER INOPERATIVE ON ANY MIC. AIRCRAFT RETURNED TO LAS AND LANDED WITHOUT INCIDENT. MAINTENANCE FOUND THE FIRST OFFICERS OXYGEN MASK SYSTEM CAUSING DISTORTION IN THE FIRST OFFICERS COMM. REMOVED AND REPLACESDR AWXA200600043Line · brokenYVR - EMERGENCY EQUIPMENT, CREW REPORTED THAT THE AIR LINE TO THE F/O'S O2 MASK BROKE OFF. CREW O2 VALVE WAS TURNED OFF. MAINTENANCE REMOVED AND REPLACED THE F/O'S O2 MASK IAW AMERICA WEST AIRLINES TASK CARD R1B35001.SDR AWXA200600015Regulator · stuckEMERGENCY EQUIPMENT, DURING C 16 CHECK DISCOVERED CAPTAIN'S OXYGEN MASK DEMAND REGULATOR STUCK IN EMERGENCY POSITION. MAINTENANCE REMOVED AND REPLACED THE O2 MASK IAW TASK CARD R1B35001. OPERATIONAL CHECKS WERE GOOD. VENDOR TEAR DOWN DOES NOT CONFIRM FAULT.SDR UPS05M45883Oxygen Mask · inoperativeFO O2 MASK FAILED TEST. SWAPPED F/O 02 MASK WITH 2ND OBSERVERS MASK IAW MM 35-13-10-4.SDR AU510002130Oxygen Bottle · leakingCOCKPIT OXYGEN BOTTLE LEAKING FROM VALVE.SDR AU510001655Connector · leakingCREW OXYGEN MASK BOX ASSEMBLY CONNECTOR LEAKING. LOSS OF OXYGEN.SDR AALA20060129Oxygen Mask · inoperativeAFW - SECOND OBSERVER OXYGEN MASK REGULATOR INOPERATIVE. REPLACED SECOND OBSERVER OXYGEN MASK. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20050759Oxygen Bottle · dischargedINFLIGHT CREW OXYGEN PRESSURE DROPPED TO ZERO PSI IN CRUISE. REPLACED CREW OXYGEN CYLINDER AND FIRST OFFICER OXYGEN REGULATOR. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR QXEA200501557Line · leakingDEN - LOW OXYGEN PRESSURE CAUTION MESSAGE. AIRCRAFT RETURNED TO THE GATE. MAINTENANCE REPLACED THE CAPILLARY LINE AT THE GAUGE. OPERATIONAL CHECKS GOOD. AIRCRAFT RETURNED TO SERVICE.SDR MALA050825Oxygen Bottle · leakingDURING CLIMB, THE OXYGEN CWP LIGHT ILLUMINATED. OXYGEN DROPPED FROM 1400 PSI TO 800 PSI. RETURNED TO MEM. INSPECTED AREA AROUND O2 CYLINDER AND TIGHTENED B-NUTS. CHECKS GOODSDR 2005UALA01220Oxygen Mask · leakingCREW OXYGEN WAS LEAKING. REPLACED SECOND OBSERVER'S FULL FACE MASK. THIS MASK WAS ORIGINALLY INSTALLED IN THE CAPT'S POSITION AND THEN SWAPPED. OXYGEN LEAK FOLLOWED AFTER SWAP. NO NEW WRITE UPS FOR OXYGEN AFTER THE MASK WAS REPLACED.SDR ABXA050272Regulator · failedDURING CRUISE FLT, F/O USED O2 MASK, THE REGULATOR FOR F/O'S O2 FAILED. WENT TO 100 PERCENT 02 UNDER PRESSURE (EMERG) NOTE: USED 200 LBS OF O2 UNTIL TURNING OFF F/O REGULATOR. REMOVED AND REPLACED F/O'S O2 REGULATOR AND OPS AND LEAK CHECKED GOOD IAW DC9SDR MASA200500830Oxygen Mask · unwanted deployASH 7207 IAD - REAR FLIGHT ATTENDANT OXYGEN MASK POPPED OUT. MX SECURED THE MASK.SDR VNAA0510009Hose · rupturedCLIMBING THRU FL120, THE CREW HEARD A HISSING SOUND AND REPORTED THAT THE CREW OXYGEN QUANTITY WAS DEPLETED. THE QRH WAS FOLLOWED AND THE FLIGHT DIVERTED TO PIT. MAINTENANCE FOUND THE OXYGEN HOSE UNDER THE FIRST OFFICER'S MASK STOWAGE BOX RUPTURED. THE HOSESDR UPS05M45578Oxygen Mask · inoperativeINSPECTION TYPE:PS4, F/O'S OXYGEN MASK REGULATOR FAILS PRESS TO TEST. REMOVED AND REPLACED F/O'S OXYGEN MASK PER MM 35-13-01-4.SDR ABXA050243Fitting · leakingAT FLIGHT LEVEL 350, NOTICED CREW 02 BOTTLE WAS LOSING PRESSURE. DESCENDED TO LOWER ALTITUDE (170). REMAINDER OF FLIGHT, PRESSURE REMAINED AT 1000 PSI. SERVICED CREW 02 BOTTLE TO 1800 (WAS 1000) PSI. FOUND LINE FROM BOTTLE TO VALVE FITTING ON BULKHEAD LEAKSDR XN0A1270Transmitter · malfunctionedCREW O2 TO 0 PSI IN TAXI OUT SWF, BACK TO THE RAMP. RESET PRESS TRANSMITTER ON CREW BOTTLE, CHECK GOOD IAW 35-11-00.SDR UPS05845484Regulator · inoperativeCREW OXYGEN REGULATOR INOP. REPLACED CAPTAIN'S 02 REGULATOR PER 35-10-07. OPS CHECK NORMAL.SDR UPS05445459Strap · brokenCAPT'S O2 MASK SUPPORT STRAP BROKEN. REPLACED CAPT'S O2 MASK STRAP.SDR MASA200500640Oxygen Mask · deployedASH 2677 GRR. OXYGEN MASK THAT DROPPED WITH OUT COMMAND IN ROW 6. MX SECURED MASK.SDR AWXA200500943Oxygen System · reads lowCMH - DIVERSION - FLT 0064 - DURING FLIGHT, EN ROUTE TO BOS FROM LAS, CREW NOTICED THE FLIGHT DECK OXYGEN PRESSURE READING LOW, 350 PSI. CREW DIVERTED TO CMH AND LANDED WITHOUT FURTHER INCIDENT. MAINTENANCE SERVICED FLIGHT DECK OXYGEN IAW AMERICA WEST AIRLINSDR UPS05545062Oxygen Mask · leaking"A" CPTS OXYGEN MASK HARNESS "POPPED" AND STARTED LEAKING ON A CHECK TEST, CARD 0101. REMOVED AND REPLACED CPTS O2 MASK/REGULATOR ASSY IAW AMM 35-11-51-4. OPS CHECK GOOD .SDR ASOA05649Line · leakingDURING CLIMB OUT, AT APPROXIMATELY 4,000 FT, THE CREW HEARD A LOUD NOISE FOLLOWED BY A HISSING SOUND FROM BEHIND THE COCKPIT. THE CREW THEN RECEIVED A LOW OXYGEN MESSAGE ON EICAS. AN EMERGENCY WAS DECLARED AND AIRCRAFT RETURNED TO DEPARTURE, LANDING SAFETLY.SDR UPS05444910Regulator · inoperativeF/O'S 02 REG INOP. R/R F/O REGULATOR PER AMM 35-11-07 OPS CK GOODSDR A6WA200540221Pbe · damagedGALLEY PBE FALLING APART. REMOVED AND REPLACED FLIGHT ATTENDANT PBE WHOLE ASSEMBLY IAW 35-30-00. (M)SDR DLM90050333Bottle · unserviceableCREW OXYGEN PRESSURE DROPPED TO ZERO ON CLIMB. REPLACED CREW OXYGEN BOTTLE AND REGULATOR. NO LEAKS.SDR UPS05844499Oxygen Mask · inoperative02 MASK INOPERATIVE. DEFERRED M302656. REMOVED AND REPLACED 1ST OBSERVER'S 02 MASK PER MM 35-10-08. OPS CHECK NORMAL. THIS CLEARS M302656.SDR UPS05844495Oxygen Mask · will not testF/O'S 02 MASK DOESN'T SEAL DURING TEST. REPLACED 02 MASK AT F/O'S POS. OPS & LEAK CHECK GOOD PER MM 35-10-00.SDR UPS05844467Oxygen Mask · leakingINSPECTION TYPE:N/A F/O'S OXYGEN MASK LEAKS. REMOVED AND REPLACED F/O'S REGULATOR AND MASK PER MM CHAPT 35-10-08-2 AND CHAPT 35-10-07-4. OPS LEAK CHECK GOOD.SDR UPS05244442Oxygen Mask · inoperativeCREW PREFLIGHT - F/O O2 MASK WOULD NOT TRANSMIT. REMOVED AND REPLACED F/O'S 02 MASK ASSY. OPS CKS GOOD IAW MM 35-11-00.SDR 2005UALA00384Hose · leakingAFTER LEVEL-OFF A/C LEAK RE-DEVELOPED AND SLOW STEADY PRESSURE DROP. LOCATED OXYGEN HOSE LEAK AT PRESSURE REGULATOR. REPLACED HOSE AND SERVICED CREW OXYGEN BOTTLE.SDR AWXA200500366Screw · faultyABQ - EMERGENCY EQUIPMENT FAILURE - FLT 0757 - DURING DESCENT INTO ABQ FOR CAPTAINS WINDSHIELD FAILURE WITH CREW OXYGEN MASKS DONNED, THE CAPTAINS MASK BECAME FOGGED UP. WHEN EMERGENCY POSITION WAS SELECTED ON THE MASK AIRFLOW AND ABILITY TO SPEAK WERE INHIBISDR UPS05544194Elbow · leakingINSPECTION TYPE:N/A PER TECH ALERT H29535 FOUND CAPT'S SUPPLY HOSE ELBOW FITTING SLOW LEAK (ELBOW FITTING ATTACHED TO STOWAGE BOX) LIMNE CAPPED. REPLACED CAPT'S AND F/O`S ELBOW FITTING AND AS A PRECAUTION, R2 CAPTS AND F/O`S MASK AND MASK STOWAGE BOXES PER MMSDR UPS05244125Regulator · leakingINSPECTION TYPE:N/A CREW OXYGEN SYSTEM LEAKING AT REGULATOR DIRECTLY ABOVE BOTTLE. REMOVED AND REPLACED CREW 02 PRESS REDUCING REGULATOR PER MM 35-11-21. LEAK AND OPS CHECK GOOD.
Back to JASC 3510