JASC 5210
Service difficulty reports · 45,713
Reports filed under 5210 · Passenger/Crew Doors, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5210' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5210' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA202102029015Retainer · missingAIRCRAFT IN BASE MAINTENANCE: THE RETAINER FOR THE DISARM COLLAR IS MISSING ON DOOR 2L. INSTALLED NEW RETAINER ON L2 DOOR PER AMM 52-12-02-400-801.SDR GTIA2021020135581Assist Assy · depletedL1 DOOR ASSIST REQ SERVICE. SERVICED L1 DOOR ASSIST IAW AMM 52-10-00. PG NK2236 CAL DUE 2/21 TW NK2650CAL DUE 2/21SDR GTIA2021020135580Bottle · depletedL-1 DOOR ASSIST BOTTLE LOW. SERVICED L-1 DOOR ASSIST BOTTLE IAW AMM 52-22-00.SDR YENA2021020400085Arming Lever · bindingFLIGHT 2232, BDA-JFK. FORWARD DOOR (L1) ARMING LEVER HARD TO ARM; INSPECTED L1 DOOR SLIDE, MECHANISM FOUND DEBRIS ON GIRT BAR, CLEAR DEBRIS AND PERFORMED OPS CHECK IAW AMM 52-11-22.SDR IPXA2021020165186Cable · out of rigINSPECTION TYPE:NAWHILE WORKING ON L1 CABIN DOOR FOUND AFT UPPER CABLE AND LOWER CABLE OUT OF RIGRIGGED L1 DOOR CABLES PER AMM 52 11 02 830 801 PARA F. STEP (10) PERFORMED F/W PASSENGER DOOR OPERATION TEST PER AMM 52 11 02. OPS CHECK GOOD DOOR OK TO CONTINUE FSDR QXEA2021020200044Unknown · unknownMAIN CABIN DOOR WOULD NOT CLOSE COMPLETELY. STUCK IN AN INTERMEDIATE POSITION AND UNABLE TO CLOSE FURTHER. REMOVED FROM SERVICE. PERFORMED OPERATIONAL CHECK OF THE L1 ENTRY DOOR, NO FAULTS NOTED. REF SDS MANUAL 52-11-00. PERFORMED ARMED / DISARMED OF L1 DOOR RSDR GTIA2021020135579Bottle · depletedR2 DOOR ASSIST NEEDS SERVICING. SERVICED R2 DOOR ASSIST IAW AMM 52-10-00.SDR DXTA202101314659Pin · stiffUPON LANDING WE WERE UNABLE TO OPEN MAIN CABIN DOOR. THE MECHANICS WERE ABLE TO OPEN FROM THE OUTSIDE. DOOR APPEARED TO HAVE BEEN FROZEN IN PLACE. CORRECTIVE ACTION: MET CREW ON THE RAMP AND FOUND ICE ACCUMULATED ON THE OUTSIDE OF THE MED DOOR. OPENED THE SDR SWIA202156951Intercostal · corrodedPAX DOOR INTERCOSTAL DD6 HAS CORROSION. (C-CHECK) RO 3/11/2021 REMOVED AND REPLACED PAX DOOR INTERCOSTAL DD6 REF CRJ 700 SRM 51-42-06-001-001-A01 DWG 601R31702 REV N COMPLIED WITH TASK CARD 51-900-1002-SKY. LEAK CHECK GOOD. SEE CONTINUE CARD FOR DETAILS.SDR SWIA202156690Intercostal · corrodedPAX DOOR AFT DD3 INTERCOSTAL HAS CORROSION (C-CHECK) RO 3/4/2021 REMOVED AND INSTALLED NEW AFT DD3 INTERCOSTAL IAW CRJ 900 SRM 51-42-06-001-001-A01 AND BOMBARDIER DWG 601R31702 REV. N. / SEE CONTINUE CARD FOR DETAILS. / COMPLIED WITH SKYWEST TASK CARD #5SDR SWIA202156689Intercostal · corrodedPAX DOOR DD7A INTERCOSTAL HAS CORROSION (C-CHECK) RO 3/4/2021 REPLACED PAX DOOR INTERCOSTAL DD7A REF CRJ900 SRM 51-42-06-001-001-A01 & DRAWING 601R31702 REV N. SEE CONTINUATION CARD FOR DETAILS. CHECKS GOOD. COMPLIED WITH TASK CARD 51-900-1002-SKY.PRESSDR SWAA2021022245908Bracket · crackedAFT ENTRY DOOR PANEL 834DZ HAS A CRACKED BRACKET / REMOVED CRACKED BRACKET FROM AFT ENTRY DOOR PANEL 834DZ AND REPLACED WITH NEW BRACKET P/ 411A2129-548; IAW SRM 51-40-02-0G-0. ATAG A14534SDR SWIA202156358Anchor Fitting · corrodedWHILE REMOVING PAX DOOR AFT COUNTERBALANCE ANCHOR-FITTING (PN 601R38074-3) TO FOM, FOUND SERRATED SIDE TO BE CORRODED. NO ALLOWABLE LIMITS PER SRM 52-00-27 (C-CHECK) RO 2/17/2021 RECEIVED REPLACEMENT PAX DOOR AFT ANCHOR FITTING, REFERENCE CAMP 22008656 FOR SDR R61A2021020200138Door · lack of lubeL1 DOOR HARD TO OPEN AND CLOSE. CLEANED AND LUBED L1 DOOR MECHANISMS, OPS CHECK GOOD.SDR AALA202102019033Girt Bar · lack of lubeAIRCRAFT WAS GROUNDED: 4R DOOR MODE SELECT LEVER DIFFICULT TO OPERATE. CLEANED AND LUBED 4R DOOR GIRT MECHANISM AND REINSTALLED DOOR ASSEMBLY IAW WORK CARD 72L80025001, OPS CHECK GOOD.SDR AALA202102019031Battery · faultyAIRCRAFT WAS NOT GROUNDED: DOOR 3L EPAS DISPLAYS FLASHING GREEN LIGHT. REPLACED EPAS BATTERY OF DOOR 3L WITH SERVICEABLE UNIT IAW AMM 52-11-20, OPS CHECK GOOD.SDR AALA202101309004Valve · low pressureAIRCRAFT WAS NOT GROUNDED: R4 DOOR ASSIST BOTTLE LOW. R & R VALVE FILLING PER AMM 52-10-00.SDR DALA2021020100607Door · stickingLOG 7516328 2 FLIGHTS IN A ROW THE GATE AGENT COULDN'T OPEN THE FORWARD LEFT ENTRY DOOR FROM THE OUTSIDE. LUBED DOOR PER B737 FIM 52-10. EXERCISED DOOR SEVERAL TIMES. OPS CHECKS GOOD.SDR GTIA2021020135578Bottle · depletedR1 DOOR ASSIST REQ SERVICE. SERVICED R1 DOOR ASSIST IAW AMM 52-10-00. TW NK2650 CAL DUE 2/21. PG NK2236 CAL DUE 2/21SDR SWIA202156961Retainer · nickedPAX DOOR LOWER CENTER SEAL RETAINER HAS MULTIPLE NICKS AND IS BENT (C-CHECK) RO 3/11/2021 REMOVED AND REPLACED PAX DOOR LOWER SEAL RETAINER REF CRJ 700 SRM 51-42-06-001-001-A01 AND DWG 601R31702 REV NC. COMPLIED WITH TASK CARD 51-900-1002-SKY. LEAK CHECK SDR SWIA202156950Support Angle · corrodedPAX DOOR AFT SUPPORT ANGLE HAS MULTIPLE SPOTS OF COROSION (C-CHECK) RO 3/11/2021 REMOVED AND REPLACED PAX DOOR AFT SUPPORT ANGLE REF CRJ 700 SRM 51-42-06-001-001-A01, CRJ 700 SRM 51-42-21-001-001-A01 & DWG 601R31702 REV N. SEE CONTINUE CARD FOR DETAILS. LSDR SWIA202156949Intercostal · corrodedPAX DOOR INTERCOSTAL DD2 HAS COROSION (C-CHECK) RO 3/11/2021 REMOVED AND REPLACED PAX DOOR INTERCOSTAL DD2 REF CRJ 700 SRM 51-42-06-001-001-A01 AND DWG 601R31702 REV N COMPLIED WITH TASK CARD 51-900-1002-SKY. LEAK CHECK GOOD. SEE CONTINUE CARD FOR DETAILSDR SWIA202156913Plate · chafed* PAX DOOR AFT GUIDE PLATE CHAFED. (C-CHECK) RO 3/10/2021 EVALUATED PAX DOOR AFT GUIDE PLATE AND FOUND TO BE OUT OF LIMITS, (OVER 10% MATERIAL LOSS) REF: CRJ 200. SRM 52-00-00, TOOL USED: TUC 8529, CAL DUE DATE: 31-AUG-21. REPLACED GUIDE PLATE AT PAX DOORSDR SWAA2021021745354Link · looseL1 DOOR LOWER RADIUS LINK LOOSE. NO HARDWARE INSTALLED. REMOVED AND REPLACED L1 DOOR LOWER RADIUS LINK REF B737-700 AMM 52-11-00-400-401 52-11-06-820-.SDR 9JLA2021020324276Link · brokenTHE FLIGHT CREW REPORTED THAT THE MAIN ENTRY DOOR STEP LINK BROKE DURING USE. THE MAINTENANCE TEAM REPLACED THE STEP LINK WITH A NEW CONDITION LINK. THE AIRCRAFT WAS RETURNED TO SERVICE. THIS IS A VERY COMMON PROBLEM WITH THE BEECHJET AND COULD CAUSE HARM IF SSDR DALA2021020100619Seal · tornSHIP 3503 DOOR 1L UPPER DOOR FRAME SEAL TURN. CORRECTIVE ACTION: REMOVED AND REPLACED 1L UPPER DOOR FRAME SEAL IAW A350 AMM A350- A-52-11-73. OK FOR SVC.SDR DALA2021020100617Seal · dirtySHIP 3319 "DOOR L AFT CABIN" DISPLAY ON UPPER ECAM WITH MASTER CAUTION LIGHT. CORRECTIVE ACTION: CYCLED DOOR INDICATION WENT CLOSED. TROUBLESHOT PER A330 TSM 52-13-00. PSCU TEST OK. CLEANED DOOR SEAL & SILL PLATE. OP CK SEVERAL TIMES NORMAL.SDR AALA202101309002Cylinder · inoperativeAIRCRAFT IN BASE MAINTENANCE: DID NOT PASS OPERATIONAL TEST PASSENGER CREW DOOR 842 DAMPING FUNCTION AT AFT GALLEY AREA. REPLACED CYLINDER DOOR DAMPER ON PASSENGER CREW DOOR 842 PER AMM 52-13-14-400-001-B.SDR AALA202101309001Cylinder · inoperativeAIRCRAFT IN BASE MAINTENANCE: DID NOT PASS OPERATIONAL TEST PASSENGER CREW DOOR 832 DAMPING FUNCTION AT AFT GALLEY AREA. REPLACED CYLINDER DOOR DAMPER ON PASSENGER CREW DOOR 832 PER AMM 52-13-14-400-001-B.SDR GTIA2021020135577Bottle · low pressureDURING WEEKLY CHECK FOUND L2 DOOR ASSIST BOTTLE LOW. SERVICED L2 DOOR IAW AMM 52-10-00 LEAK CHECK GOOD.SDR AALA202102019028Bottle · depletedAIRCRAFT WAS NOT GROUNDED: DOOR 4L EMERGENCY POWER ASSIST SYS PRESSURE BOTTLE BLOWN. R & R DOOR 4L EMERGENCY POWER BOTTLE ASSIST BOTTLE ASSEMBLY IAW AMM 52-11-22SDR DXTA2021013104659Pin · stiffUPON LANDING WE WERE UNABLE TO OPEN MAIN CABIN DOOR. THE MECHANICS WERE ABLE TO OPEN FROM THE OUTSIDE. DOOR APPEARED TO HAVE BEEN FROZEN IN PLACE. CORRECTIVE ACTION: MET CREW ON THE RAMP AND FOUND ICE ACCUMULATED ON THE OUTSIDE OF THE MED DOOR. OPENED THE SDR DXTA202101310465Door · malfunctionedUPON LANDING WE WERE UNABLE TO OPEN MAIN CABIN DOOR. THE MECHANICS WERE ABLE TO OPEN FROM THE OUTSIDE. DOOR APPEARED TO HAVE BEEN FROZEN IN PLACE. CORRECTIVE ACTION: MET CREW ON THE RAMP AND FOUND ICE ACCUMULATED ON THE OUTSIDE OF THE MED DOOR. OPENED THE SDR DXTA2021013104657Door · out of balanceMAIN CABIN DOOR NEEDS ADJUSTING. THE DOOR LOWERS VERY QUICKLY WITH VERY LITTLE COUNTERBALANCE WEIGHT HOLDING DOOR IN THE CLOSED POSITION. THE CONDITION MAY HAVE CAUSED UPPER STEP PANEL TO COME OFF. CORRECTIVE ACTION: GAINED ACCESS TO MAIN CABIN DOOR SPRING SDR SWIA202156960Stiffener · corrodedPAX DOOR AFT WEB STIFFENER PN 601R317743-7 FASTENERS HOLES AREA CORRODED. (C-CHECK) RO 3/11/2021 REMOVED AND REPLACED PAX DOOR AFT WEB STIFFENER REF CRJ 700 SRM 51-42-06-001-001-A01SDR SWIA202156959Attach Angle · corrodedPAX DOOR AFT WEB ATTACHMENT ANGLE PN 601R31772-5 FOUND TO BE CORRODED. (C-CHECK) RO 3/11/2021 REMOVED AND REPLACED PAX DOOR AFT WEB ATTACHMENT ANGLE PN 601R31772-5 REF CRJ 700 SRM 51-42-13-001-001-A01SDR SWIA202156953Stiffener · crackedPAX DOOR FWD WEB @ FS 347 STIFFNER IS CRACKED (C-CHECK) RO 3/11/2021 REMOVED AND REPLACED PAX DOOR STIFFENER FS 347 REF DWG 601R31702 REV NC AND CRJ 700 SRM 51-42-06-001-001-A01SDR SWIA202156947Intercostal · corrodedPAX DOOR INTERCOSTAL DD7 HAS COROSION (C-CHECK) RO 3/11/2021 REMOVED AND REPLACED PAX DOOR INTERCOSTAL DD7 REF CRJ 700 SRM 51-42-06-001-001-A01 DWG 601R31702 REF N COMPLIED WITH TASK CARD 51-900-1002-SKY. LEAK CHECK GOOD. SEE CONTINUE CARD FOR DETAILS.SDR SWIA202156946Intercostal · corrodedPAX DOOR INTERCOSTAL P/N 601R31902-317 HAS CORROSION (C-CHECK) RO 3/11/2021 REMOVED AND REPLACED PAX DOOR INTERCOSTAL REF CRJ 700 SRM 51-42-06-001-001-A01 AND DWG 601R31702 REV N COMPLIED WITH TASK CARD 51-900-1002-SKY. LEAK CHECK GOOD. SEE CONTINUE CARD SDR SWIA202156945Intercostal · corrodedPAX DOOR INTERCOSTAL DD1 HAS COROSION (C-CHECK) RO 3/11/2021 REMOVED AND REPLACED PAX DOOR INTERCOSTAL DD1 REF CRJ 700 SRM 51-42-06-001-001-A01 AND DWG 601R31702 REV N COMPLIED WITH TASK CARD 51-900-1002-SKY. LEAK CHECK GOOD. SEE CONTINUE CARD FOR DETAILSSDR SWIA202156944Intercostal · corrodedPAX DOOR INTERCOSTAL DD3 HAS COROSSION (C-CHECK) RO 3/11/2021 REMOVED AND REPLACED PAX DOOR INTERCOSTAL DD3 REF CRJ 700 SRM 51-42-06-001-001-A01 AND DWG 601R31702 REV N COMPLIED WITH TASK CARD 51-900-1002-SKY. LEAK CHECK GOOD.SDR SWIA202156943Former · corrodedFWD FORM ON PAX DOOR HAS MULTIPLE SPOTS OF CORROSION (C-CHECK) RO 3/11/2021 REMOVED AND REPLACED WITH NEW FWD PAX DOOR FORMER REF CRJ 700 SRM 51-42-06-001-001-A01, REF CRJ 700 SRM 51-42-21-001-001-A01 AND DWG 601R31702 REV -N. SEE CONTINUE CARD FOR DETAILSDR SWIA202156842Intercostal · corrodedPAX DOOR INTERCOSTAL AT DD2 IS CORRODED (C-CHECK) RO 3/10/2021 REMOVED AND INSTALLED SERVICEABLE DD2 INTERCOSAL IAW CRJ 200 SRM 51-42-06 AND 51-42-21. COMPLIED WITH TASK CARD 51-900-1003-SKY (CL600-2B19). FORM 337 COMPLETED. PART FOR PART REPLACEMENT, NOSDR IPXA2021012965049Warning Light · inoperativeDURING PREFLIGHT EVACUATION SLIDE WARNING SYS LIGHT INOPERATIVE. DEFERRED PER MEL 52-73-01-1. PLACARD INSTALLED. NO DMP.R/R'D EVAC SLIDE WARNING LIGHT ASSY IAW AMM 52-73-11. OPS CHECK GOOD. M734099 CLOSED. PLACARD REMOVED. EFF SOURCE REF: IPC 52-11-11-2SDR R61A2021012900125Door · out of balanceL1 DOOR HARD TO OPEN. C/W FIM TASK 52-11-00-810-806-A, FOUND WEAK COUNTERBALANCE RODS AND L1 DOOR BOX MECHANISM LACKING LUBRICATION. R & R COUNTERBALANCE RODS AND LUBED L1 DOOR BOX MECHANISM.SDR DALA2021012900558Fitting · crackedCRACK DOOR L2 LUG FITTING UPPER POSITION IN PASSENGER CABIN. CORRECTIVE ACTION: REPLACED SUPPORT ARM DOOR L2 IN PASSENGER CABIN, AS PER A330 AMM 52-12.SDR AALA202101299014Strap · out of positionAIRCRAFT WAS NOT GROUNDED. MANUAL INFLATION HANDLE STICKING OUT OF RIGHT OVERWING EXIT. SECURED MANUAL INFLATION STRAP OF RIGHT OVERWING EXIT, PER AMM 52-21-11.SDR AALA202101299013Accumulator · low pressureAIRCRAFT WAS NOT GROUNDED. DOOR L1 EMERGENCY CYLINDER ACCUMULATOR PRESSURE LOW 1675 AT 23 DEGREES CELSIUS. SERVICED DOOR L1 EMERGENCY CYLINDER ACCUMULATOR, PER AMM 52-10-00.SDR AALA202101299012Accumulator · low pressureAIRCRAFT WAS NOT GROUNDED. DOOR R2 EMERGENCY CYLINDER ACCUMULATOR PRESSURE LOW 1675 AT 23 DEGREES CELSIUS. SERVICED DOOR R2 EMERGENCY CYLINDER ACCUMULATOR, PER AMM 52-10-00.SDR AALA202101299010Accumulator · low pressureAIRCRAFT WAS NOT GROUNDED. DOOR R1 EMERGENCY CYLINDER ACCUMULATOR RESSURE LOW 1675 AT 23 DEGREES CELSIUS. SERVICED DOOR R1 EMERGENCY CYLINDER ACCUMULATOR, PER AMM 52-10-00.
Back to JASC 5210