JASC 5210
Service difficulty reports · 45,713
Reports filed under 5210 · Passenger/Crew Doors, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5210' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5210' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA2020042089003Bottle · low pressureAIRCRAFT NOT GROUNDED - R4 DOOR, EMERGENCY CYLINDER PRESSURE LOW. SERVICED R4 DOOR EMERGENCY CYLINDER PER AMM 52-10-00-614-001, TO 1500 PSI IN OUTDOOR CONDITIONS.SDR AALA2020042089002Bottle · low pressureAIRCRAFT NOT GROUNDED - R1 DOOR, EMERGENCY CYLINDER PRESSURE LOW. SERVICED R1 DOOR EMERGENCY CYLINDER PER AMM 52-10-00-614-001, TO 1500 PSI IN OUTDOOR CONDITIONS.SDR AALA2020042089001Bottle · low pressureAIRCRAFT NOT GROUNDED - L1 DOOR, EMERGENCY CYLINDER PRESSURE LOW. SERVICED L1 DOOR EMERGENCY CYLINDER PER AMM 52-10-00-614-001, TO 1500 PSI IN OUTDOOR CONDITIONS.SDR FDEA2020041760753Door Frame · crackedRH #2 DOOR UPPER HINGE CUTOUT IS CRACKEDSDR SIMA2020041716004Support Bracket · crackedDURING HMBV INSPECTION, QC FOUND PAX DOOR HANDLE BOX SUPPORT ASSY BRACKET CRACKED.-C/A-REMOVED AND REPLACED PAX DOOR HANDLE BOX SUPPORT BRACKET IAW EMB 145 SRM 51-40-02.SDR AALA202004179002Bottle · low pressureAIRCRAFT IN BASE MAINTENANCE - R1 DOOR, ASSIST ACCUMULATOR LOW PRESSURE. SERVICED R1 DOOR ASSIST BOTTLE PER AMM 52-10-00, LEAK CHECK GOOD AT THIS TIME.SDR AALA202004179001Bottle · low pressureAIRCRAFT IN BASE MAINTENANCE - L2 DOOR ASSIST ACCUMULATOR LOW. SERVICED L2 DOOR ASSIST BOTTLE PER AMM 52-22-00, LEAK CHECK GOOD AT THIS TIME.SDR AALA2020041769003Bottle · low pressureAIRCRAFT NOT GROUNDED - R4 DOOR DAMPER (DOOR ASSIST BOTTLE) REQUIRES SERVICING. SERVICED R4 DOOR DAMPER (DOOR ASSIST BOTTLE) PER AMM 52-10-00.SDR COEA2020041602806Skin · damagedHATS WO 162821 NR DTI806-04 EMPIRE WO 197942 NR 51 HEAVY CHECK HATS/MAJOR REPAIR: FUSELAGE PAX DOOR SURROUND SKIN DAMAGE DUE TO SHOOT BOLT IMPACT AT FRAME 36 & 39. CORRECTIVE ACTION: REPAIRED PER SRAS ES-1437/16...15553 ISSUE B, DATED 2/21/2020.SDR SWIA202005110585Intercostal · corrodedPAX DOOR INTERCOSTAL DD2 PN.601R318053-3 HAS CORROSION (C-CHECK) RO 5/7/2020 REPLACED PAX DOOR INTERCOSTAL DD2 PER SRM & BOMBARDIER DRAWING. SEE CONTINUATION CARD FOR DETAILS. COMPLIED WITH TASK CARDSDR SWIA202005110582Intercostal · corrodedPASSENGER DOOR: INTERCOSTAL DD5 P/N 601R318091-5 HAS CORROSION (C-CHECK) RO 5/7/2020 REPLACED PAX DOOR INTERCOSTAL DD5 PER SRM & BOMBARDIER DRAWING. SEE CONTINUATION CARD FOR DETAILS. COMPLIED WITH TASK CARDSDR SWIA202005110581Door Frame · corrodedPASSENGER DOOR: FRAME LOCATED AT FS313.56 BETWEEN DD4 AND DD5 IS CORRODED. (C-CHECK) RO 5/7/2020 REPLACED PASSENGER DOOR FRAME AT FS 313.56 BETWEEN DD4 AND DD5 AS PER CRJ 700 SRM AND BOMBARDIER DWG. COMPLIED WITH SKYWEST TASK CARD. CHECKS GOOD.SDR SWIA20205060511Intercostal · corrodedCORROSION FOUND ON PASSENGER DOOR INTERCOSTAL DD7A P/N# 601R317052-1. (C-CHECK) RO 5/4/2020 REMOVED THE CORROSION FROM THE PAX DOOR INTERCOSTAL DD7A. FOUND TO BE OUT OF LIMITS.REMOVED & INSTALLED NEW PAX DOOR INTERCOSTAL MID DD7A REF. CRJ 700 SRM AND BOMBASDR SWIA20205060510Doubler · crackedCRACK FOUND ON PASSENGER DOOR DOUBLER PULL IN CAM. (C-CHECK) RO 5/4/2020 INSTALLED NEW PASSENGER DOOR PULL IN CAM DOUBLER IAW CRJ700 SRM & DWG. OPERATIONAL TEST GOOD. COMPLIED WITH SKYWEST TASK CARD.SDR SWIA20205060509Intercostal · corrodedCORROSION FOUND ON PASSENGER DOOR INTERCOSTAL DD2. (C-CHECK) RO 5/4/2020 REMOVED & INSTALLED NEW PAX DOOR MID DD2 INTERCOSTAL REF CRJ 700 SRM AND BOMBARDIER DWG. SKYCARD COMPLIED WITH. ALL CHECKS GOODSDR SWIA20205060508Intercostal · crackedCRACK FOUND ON PASSENGER DOOR INTERCOSTAL DD1 P/N# 601R31902-318. (C-CHECK) RO 5/4/2020 REMOVED & INSTALLED NEW INTERCOSTAL P/N 601R31902-318 ON PASSENGER DOOR. REF: CRJ-700 SRM AND DWG. SKYCARD. COMPLIED WITH. ALL CHECKS GOODSDR SWIA20205060507Intercostal · corrodedCORROSION FOUND ON PASSENGER DOOR INTERCOSTAL P/N# 601R31902-317 DD5. (C-CHECK) RO 5/4/2020 PASSENGER DOOR INTERCOSTAL P/N# 601R31902-317 DD5 HAS EXFOLIATED CORROSION BEYOND LIMITS. INSTALLED NEW PASSENGER DOOR INTERCOSTAL P/N# 601R31902-317 DD5. REF: CRJ-SDR SWIA20205060506Intercostal · corrodedCORROSION FOUND ON PASSENGER DOOR INTERCOSTAL DD3. (C-CHECK) RO 5/4/2020 REMOVED & INSTALLED NEW PAX DOOR MID DD3 INTERCOSTAL IAW CRJ 700 SRM AND BOMBARDIER DWG. SKYCARD COMPLIED WITH ALL CHECKS GOODSDR SWIA20205060505Intercostal · corrodedCORROSION FOUND ON PASSENGER DOOR INTERCOSTAL DD1. (C-CHECK) RO 5/4/2020 REMOVED & INSTALLED NEW PAX DOOR MID DD1 INTERCOSTAL IAW CRJ 700 SRM AND BOMBARDIER DWG. COMPLIED WITH SKYCARD. ALL CHECKS GOODSDR SWIA20205060504Former · corrodedAFTER REMOVING PASSENGER DOOR INNER SKIN FOUND SEVERE CORROSION ON FWD FORMER FS311.75. (C-CHECK) RO 5/4/2020 REMOVED & INSTALLED NEW PAX DOOR FWD FORMER REF CRJ 700 SRM AND REF BOMBARDIER DWG. SKYCARD COMPLIED WITH. ALL CHECKS GOODSDR DALA2020041602268Bolt · shearedSHIP 5641 L1 PAX DOOR EXTERIOR HANDLE WILL NOT GO FLUSH WHEN CLOSED. CORRECTIVE ACTION: REMOVED THE TWO COVERPLATES UNDER BUTTERFLY HANDLE FOUND SHEARED BOLT LODGED UNDER MECHANISM. REMOVED BOLT AND EXTRACTED THREADED END OF BOLT. INSTALLED NEW BOLT AND RETAINSDR SWIA202005110580Former · corroded*PAX DOOR FWD FORMER HAS MULTIPLE SPOTS OF CORROSION. (C-CHECK) RO 5/7/2020 REMOVED AND REPLACED PAX DOOR FWD FORMER REF CRJ 700 SRM & BOMBARDIER DWG. CHECKS GOOD. COMPLIED WITH SKYWEST TASK CARD.SDR SWIA202005110578Former · crackedPAX DOOR AFT FORMER FS347.27 IS CRACKED UNDER INNER SKIN FASTENER HOLE, ABOUT 49" UP FROM BOTTOM (C-CHECK) RO 5/7/2020 REPLACED PAX DOOR AFT FORMER AT FS 347.27 AS PER CRJ 700 SRM AND BOMBARDIER DWGSDR SWIA20205060523Skin · corroded*PAX DOOR INNER SKIN HAS MULTIPLE AREA'S OF CORROSION. CIRCLED IN GREASE PENCIL AND FLAGGED. (C-CHECK) RO 5/4/2020 REMOVED, REPLACED AND INSTALLED NEW PAX DOOR INNER SKIN REF CRJ 700 SRM.SDR AALA202004179011Bushing · migratedAIRCRAFT WAS GROUNDED: UPON ARRIVAL THE L1 DOOR WAS FOUND TO BE JAMMED SHUT AND WOULD NOT OPEN TO ALLOW PASSENGERS TO DEPLANE. MAINTENANCE FOUND THE FORWARD LOWER ARM BUSHING HAD MIGRATED OUT ABOUT .5 INCHES CAUSING THE FORWARD ROLLER TO BIND. SUPPLEMENTAL REPSDR GTIA2020041635164Bottle · low pressureR2 DOOR ASSIST BOTTLE REQUIRES SERVICING.-SERVICED R2 DOOR ASSIST BOTTLE IAW AMM 52-10-00.SDR AALA202004159007Bottle · low pressureAIRCRAFT NOT GROUNDED - L2 DOOR PRESSURE LOW. SERVICED L2 DOOR PRESSURE PER AMM 52-22-00, OKAY FOR CONTINUED SERVICE.SDR AALA202004159005Battery Pack · dischargedAIRCRAFT NOT GROUNDED - R1 DOOR EPAS NOT BLINKING. REMOVED AND REPLACED BATTERY PACK IN R1 EPAS, OPERATIONAL CHECKS NORMAL PER AMM 52-12-20.SDR SWIA20205060492Intercostal · corroded*PAX DOOR INTERCOSTAL DD4 IS CORRODED. FLAGGED (C-CHECK) RO 5/4/2020 REMOVED & INSTALLED NEW PAX DOOR MID DD4 INTERCOSTAL IAW CRJ 700 SRM AND BOMBARDIER DWG. COMPLIED WITH SKYCARD ALL CHECKS GOODSDR SWIA20205060491Intercostal · corroded*PAX DOOR INTERCOSTAL DD6 IS CORRODED. (C-CHECK) RO 5/4/2020 REMOVED AND INSTALLED NEW PAX DOOR INTERCOSTAL DD6 P/N 601R318057-1 . REF CRJ 700 SRM AND BOMBARDIER DWG. COMPLIED WITH SKYWEST TASKCARD. PRESSURE CHECKS GOOD.SDR SWIA20205060490Former · corroded*PAX DOOR FORMER,FS329.76 IS CORRODED. FLAGGED (C-CHECK) RO 5/4/2020 REMOVED AND INSTALLED NEW PAX DOOR FORMER P/N 601R318078-3 REF CRJ 700 SRM AND BOMBARDIER DWG. SKYCARD COMPLIED WITH ALL CHECKS GOODSDR AALA202004149005Diaphragm · defectiveAIRCRAFT NOT GROUNDED - L1 DOOR ASSIST BOTTLE LOW. REPLACED DIAPHRAGM DISK IN L1 DOOR ASSIST BOTTLE PER AMM 52-10-00, OPERATIONAL CHECK GOOD.SDR AALA202004149004Bottle · low pressureAIRCRAFT IN BASE MAINTENANCE - L4 DOOR ASSIST CYLINDER PRESSURE LOW - APPROX. 1350PSI. SERVICED L4 DOOR CYLINDER PER AMM 52-10-00. OKAY FOR SERVICE.SDR AALA202004149003Bottle · low pressureAIRCRAFT IN BASE MAINTENANCE - R3 DOOR ASSIST CYLINDER PRESSURE LOW - IN RED BAND. SERVICED R3 DOOR CYLINDER PER AMM 52-10-00. OKAY FOR SERVICE.SDR AALA202004149002Bottle · low pressureAIRCRAFT IN BASE MAINTENANCE - L3 DOOR ASSIST CYLINDER PRESSURE LOW - IN YELLOW BAND. SERVICED L3 DOOR CYLINDER PER AMM 52-10-00, OKAY FOR SERVICE.SDR AALA202004149001Bottle · low pressureAIRCRAFT IN BASE MAINTENANCE - R1 DOOR ASSIST CYLINDER PRESSURE LOW - APPROX. 400 PSI. SERVICED R1 DOOR CYLINDER PER AMM 52-10-00, OKAY FOR SERVICE.SDR GTIA2020041335161Bottle · low pressurePASSENGER / CREW R2 DOOR REQUIRE SERVICING -SERVICED PASSENGER / CREW DOORS ASSIST BOTTLE AT R2 IAW AMM 52-10-00-210-004SDR ASAA2020041132639Handle · malfunctionedL-1 DOOR WILL NOT CLOSE WITH INTERIOR HANDLE DOOR OPERATES NORMAL WITH EXTERIOR HANDLE. GROUNDED - YES. EXCESSIVE FORCE NEEDED TO BE APPLIED TO INTERIOR HANDLE. DOOR DOES NOT CLOSE AND HANDLE SPRINGS BACK WHEN RELEASED. OPS CK NORMAL. OK FOR SERVICE.SDR AALA2020041039003Accumulator · low pressureAIRCRAFT NOT GROUNDED - L4 DOOR ASSIST ACCUMULATOR IS LOW. SERVICED L4 DOOR ASSIST ACCUMULATOR PER AMM 52-13-14.SDR CALA2020041300828Pan · abnormal(B757-53-3-0545) LH SIDE UPPER LOBE FUSELAGE L1 DOOR HANDLE PAN HAS TWO GOUGES. REF ST-SAA NR 0091391. CHECKED LIMITS TO 2EA GOUGES AT LH SIDE UPPER LOBE FUSELAGE L1 DOOR HANDLE PAN L=2.0 W=.10 D=.012. OUT OF LIMITS IAW B757-3 SRM 52-10-01 FIG 101 DETAIL VI ASDR AALA2020041319002Bottle · low pressureAIRCRAFT IN BASE MAINTENANCE - R4 DOOR ASSIST BOTTLE PRESSURE BEYOND LIMITS. R4 DOOR ASSIST BOTTLE SERVICED PER AMM 52-10-00, LEAK TEST GOOD.SDR AALA2020041309003Damper · low pressureAIRCRAFT NOT GROUNDED - CIDS PANEL SHOWS LOW PRESSURE ON R2 DOOR DAMPER. SERVICED R2 DOOR DAMPER PER AMM 52-10-00, NO LEAKS NOTED, OPERATIONAL CHECK GOOD.SDR GTIA2020041335159Bottle · low pressureL1 DOOR ASSIST BOTTLE REQUIRES SERVICE.-SERVICED L1 DOOR ASSIST BOTTLE IAW AMM 52-10-00.SDR AALA2020041309002Cylinder · low pressureAIRCRAFT NOT GROUNDED - R2 DOOR CYLINDER IS BELOW PRESSURE LIMITS. SERVICED R2 DOOR CYLINDER PER AMM 52-10-00, OKAY FOR SERVICE.SDR DALA2020040902231Plate · missingSHIP 667 DURING GIRT BAR LUBE FOUND 1 DOOR STOP BEARING PLATE MISSING AT 1L AND 4R. CORRECTIVE ACTION: INSTALLED DOOR BEARING PLATES AT 1L AND 4R IAW B757 AMM 52-11. (6878946)SDR SWIA202005110600Support Bracket · corroded* THE PAX DOOR PANEL 832AB UPPER SUPPORT BRACKET FROM FS320.163 TO FS338.963 HAS CORROSION. (MARKED) (C-CHECK) RO 5/7/2020 REPLACE PAX DOOR UPPER SUPPORT BRACKET PER SRM.SDR SWIA202005110599Bracket · corroded* THE PAX DOOR UPPER BRACKET AT FS335.763 FOR PANEL 832AB HAS CORROSION. (MARKED) (C-CHECK) RO 5/7/2020 REPLACED 2 EA BRACKETS FOR PANEL 832AB (P/N: 601R31902-148 AND 601R31902-555) AS PER CRJ 700 SRMSDR SWIA202005110598Bracket · corroded* THE PAX DOOR UPPER BRACKET AT FS323.363 FOR PANEL 832AB HAS CORROSION. (MARKED) (C-CHECK) RO 5/7/2020 REPLACED PAX DOOR UPPER BRACKETS (P/N: 601R31902-147 AND 601R31902-556) FOR PANEL 832AB AS PER CRJ 700 SRM.SDR SWIA202005110597Skin · corroded* THE PAX DOOR INNER SKIN HAS MULTIPLE LOCATIONS OF CORROSION. (MARKED) (C-CHECK) RO 5/7/2020 REPLACED PASSENGER DOOR INNER SKIN WITH FABRICATED NEW. REF CRJ-700 SRM AND DWGSDR SWIA202005110564Intercostal · corroded* THE PAX DOOR INTERCOSTAL AT DD3 BETWEEN FS320.163 AND FS338.963 HAS CORROSION. (MARKED) (C-CHECK) RO 5/7/2020 REPLACED PAX DOOR INTERCOSTAL AT DD3 BETWEEN FS320.163 & 338.963 PER SRM & BOMBARDIER DRAWING. SEE CONTINUATION CARD FOR DETAILS. COMPLIED WI
Back to JASC 5210