JASC 5210
Service difficulty reports · 45,724
Reports filed under 5210 · Passenger/Crew Doors, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5210' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5210' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWIA200922424Handle · out of positionMAIN CABIN DOOR WILL NOT OPEN FROM OUTSIDE. (FLT 6157) FOUND OUTER HANDLE IMPROPERLY STOWED. OPERATIONAL CHECKS NORMAL.SDR AALA20090822TUL03Torque Box · crackedLEFT NUMBER FOUR PASSENGER ENTRY DOOR HANDLE TORQUE BOX CRACKED AT CAM BASKET MOUNT HOLE. REMOVED AND REPLACED HANDLE TORQUE BOX UNDER ESO 90108.SDR AALA20090822TUL02Pan · crackedRIGHT NUMBER FOUR PASSENGER ENTRY DOOR HANDLE BOX CRACKED. REMOVED AND REPLACED DOOR HANDLE BOX UNDER ESO 90108.SDR AALA20090822TUL01Torque Box · crackedRIGHT NUMBER ONE PASSENGER ENTRY DOOR TORQUE BOX IS CRACKED AT CAM BASKET MOUNT HOLES. REMOVED AND REPLACED TORQUE BOX UNDER ESO 90284.SDR ASOA200900919Drag Angle · crackedASD AFT SIDEWALL DRAG ANGLE CRACKED. COMPLIED WITH REO 601R-52-11-513 FOR DRAG ANGLE REPAIR. JOB COMPLETE.SDR AALA20090821TUL05Pan · damagedLEFT NUMBER 2 DOOR PASSENGER ENTRY OUTER HANDLE PAN HAS GROOVE WORN IN IT. REMOVED AND REPLACED PAN UNDER ESO 90282.SDR AALA20090821TUL02Pan · gougedLEFT NUMBER 4 PASSENGER ENTRY DOOR HANDLE PAN GOUGED. REMOVED AND REPLACED PAN PER ESO 90108.SDR NWAA093176309Rod End · brokenDURING GROUND OPERATIONS FOUND DOOR 5L DIFFICULT TO OPEN. REPLACED BROKEN ROD END AND RIGGED DOOR PER AMM 52-11-09. DOOR FUNCTION TESTED GOOD AND AIRCRAFT WAS RETURNED TO SERVICE.SDR C2XA09TY233ALatch · stuckMAIN CABIN DOOR HARD TO OPEN TOP LATCH WAS JAMMED. ADJUSTED DOOR OPS CHECK GOOD. AIRCRAFT RETURNED TO SERVICE.SDR QXEA2009082400628Door · malfunctionedSMF - FLIGHT ATTENDANT REPORTED THAT MAIN CABIN DOOR WAS DIFFICULT TO PUSH OPEN. INSPECTED DOOR MECHANISM WITH NO DEFECTS NOTED AND C/W OPS TEST IAW AMM 52-11-00-710-801. CHECKS GOOD. COULD NOT DUPLICATE. RETURNED TO SERVICE. NO PARTS REPLACED.SDR QXEA2009082400627Motor · failedPDX - MAIN CABIN DOOR DIFFICULT TO OPEN. FOUND MCD POWER ASSIST CABLE HANGING UP IN MOTOR ASSY. REMOVED AND REPLACED MCD POWER ASSIST MOTOR ASSY IAW CRJ-700 AMM TASK 52-11-08-000-801-A02 AND TASK 52-11-08-400-801-A02. OPS CHECK GOOD. MCD NO LONGER DIFFICULSDR SWIA200922415Spring · faultyUNABLE TO OPEN MAIN CABIN DOOR. (FLT 6154) REPLACED THE FORWARD AND AFT MAIN DOOR COUNTERBALANCE SPRINGS.SDR USAA2009090492379Door Frame · crackedCLT - Q3 - MAJOR REPAIR - CRACK AT R-1 DOOR INSIDE LOWER AFT FORWARD CORNER STOP CASTING. REPLACED R-1 DOOR ASSEMBLY IAW US AIRWAYS JOB CARD 03C10652008.SDR USAA2009082092184Cylinder · low pressureFLT 77 - SEA - EMERGENCY EGRESS SYSTEM - L-1 DOOR ASSIST BOTTLE HAS LOW PRESSURE. MAINTENANCE SERVICED L-1 DOOR ASSIST BOTTLE PER AIRBUS MAINTENANCE MANUAL 52-10-00.SDR SWIA200922416Door · bindsUNABLE TO OPEN MAIN CABIN DOOR. (FLT 6053) OPERATIONAL CHECKS AND INSPECTION NORMAL.SDR RAIA2009082700001Door · out of adjustCREW REPORTED THAT THE MAIN CABIN DOOR WAS DIFFICULT TO OPEN. MX ADJUSTEDTHE MAIN CABIN DOOR AND PERFORMED AN OPS CHEC. OPS CKD GOOD. (K)SDR AALA20090817TUL01Stop Fitting · crackedFORWARD ENTRY DOOR HAS INTERNAL CRACK IN RADIUS, FORWARD JAMB AT LOWER SIDE OF NUMBER 2 STOP BRACKET SUPPORT STRUCTURE. STOP DRILLED CRACK, DYE-CHECK CONFIRMED, INSTALLED DOUBLER UNDER SRM 52-05-00 FIG 31 (SHEET 3).SDR FDEA200908173028Gate · corrodedR1 PAX DOOR LWR GATE HAS CORROSION. RI DOOR LWR GATE CORROSION FOUND EXCEEDED SRM ALLOWABLE LIMIT. DOOR GATE REMOVED AND REPLACED IAW AMM 52-11-38 REV 04. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100 CRITERIA.SDR QXEA2009082000622Door · malfunctionedSEA - MAIN CABIN DOOR DIFFICULT TO OPEN. PERFORMED OPERATIONAL TEST OF FORWARD PASSENGER DOOR PER Q400 AMM 52-11-00-710-802. CHECKS GOOD. COULD NOT DUPLICATE. RETURNED TO SERVICE. NO PARTS REPLACED.SDR SWIA200922369Door · malfunctionedUNABLE TO OPEN MAIN DOOR FROM INSIDE. (FLT 6717) OPERATIONAL CHECK NORMAL.SDR RAIA2009081700006Linkage · dirtyCREW REPORTED THAT THE PASSENGER DOOR WAS DIFFICULT TO OPEN AND CLOSE. MAINTENANCE INSPECTED, CLEANED AND LUBED THE PASSENGER DOOR OPERATING LINKAGE. OPS CHECKED GOOD AS PER AMM.SDR USAA2009081892159Damper · low pressureSAL - BC7 - EES - LOW PRESSURE CYLINDER DOOR DAMPER AT DOOR R-2. CHARGED THE DAMPER AND EMERGENCY OPERATION CYLINDER AT R-2 DOOR IAW A320 AMM 52-10-00.SDR USAA2009081892158Damper · low pressureSAL - BC7 - EES - LOW PRESSURE CYLINDER DOOR DAMPER AT DOOR L-2. CHARGED THE DAMPER AND EMERGENCY OPERATION CYLINDER AT L-2 DOOR IAW A320 AMM 52-10-00.SDR USAA2009081892157Damper · low pressureSAL - BC7 - EES - LOW PRESSURE CYLINDER DOOR DAMPER AT DOOR L-1. CHARGED THE DAMPER AND EMERGENCY OPERATION CYLINDER AT L-1 DOOR IAW A320 AMM 52-10-00.SDR UALA2009081702512Cable · frayedLEFT AFT ENTRY DOOR COUNTERBALANCE PRIMARY CABLE IS FRAYING, BS 1461-1480, STR 1L-2L. REMOVED AND REPLACED LEFT AFT ENTRY DOOR COUNTERBALANCE PRIMARY CABLE. SYSTEM TESTED GOOD.SDR UALA2009081702511Pulley · wornLEFT AFT ENTRY DOOR COUNTERBALANCE PRIMARY SWIVEL CABLE PULLEY WORN, BS 1461- BS 1480, STR 1L - 2L. REPLACED COUNTERBALANCE PULLEY AT BS 1461-1480, STR 1L-2L. DOOR OPS CHECK NORMAL.SDR USAA2009081792142Cylinder · low pressureFLT 1201 - CLT-CLT - EMERGENCY EQUIPMENT - L2 PASSENGER DOOR EMERGENCY OPERATING CYLINDER PRESSURES BELOW LIMIT. SERVICED L1 & L2 PASSENGER DOOR EMERGENCY OPERATING CYLINDER PER MAINTENANCE MANUAL 52-10-00-614-01.SDR USAA2009081792140Cylinder · low pressureFLT 1201 - CLT-CLT - EMERGENCY EQUIPMENT - L1 PASSENGER DOOR EMERGENCY OPERATING CYLINDER PRESSURES BELOW LIMIT. SERVICED L1 & L2 PASSENGER DOOR EMERGENCY OPERATING CYLINER PER MAINTENANCE MANUAL 52-10-00-614-01.SDR USAA20090817EM052Mechanism · out of adjustFLIGHT 1821, CLT-MYR - THE 1L DOOR WOULD NOT OPEN FROM THE OUTSIDE. MAINTENANCE INSPECTED THE 1L DOOR AND FOUND NO DAMAGE AND ADJUSTED THE DOOR MECHANISM. PRIOR HISTORY - ON AUGUST 6, 2009 THE L1 DOOR WAS HIT BY THE JETWAY. MAINTENANCE PERFORMED A SATISFACTSDR A6WA200940529Drag Angle · crackedPASSENGER DOOR STAIR AFT DRAG ANGLE CRACKED. AFT DRAG ANGLE REPAIR CARRIED OUT IAW REO 601R-52-11-513. (K)SDR AALA20090814TUL22Beam · crackedFORWARD ENTRY DOOR NUMBER 6 BEAM CRACKED AT BAYONET CRANK MOUNT HOLE. STOP DRILLED CRACK, DYE CHECKED, INSTALLED PASSENGER DOOR BEAM DOUBLER.SDR RAIA2009081700005Roller · out of adjustCREW REPORTED THAT THE PASSENGER DOOR WAS HARD TO OPEN. MAINTENANCE ADJUSTED THE UPPER DOOR ROLLERS AND PERFORMED AN OPERATIONAL CHECK OF THE DOOR. OPS CHECKED GOOD.SDR RAIA2009081700004Door · stiffTHE FLIGHT ATTENDANT REPORTED THAT THE MAIN CABIN DOOR WAS HARD TO OPEN. MAINTENANCE LUBED THE DOOR SEAL AND PERFORMED AN OPERATIONAL CHECK OF THE DOOR. OPS CHECKED GOOD.SDR UALA2009081702505Bottle · low pressureDOOR 1L ASSIST BOTTLE LOW PRESSURE. REPLACED DIAPHRAGM AND O-RINGS PRESSURE GOOD.SDR FDEA200908143015Gate · corrodedL1 DOOR, LOWER DOOR GATE HAS CORROSION. REMOVED AND REPLACED IAW AMM 52-11-38 REV. 4. OPERATION CHECK CARRIED OUT IAW AMM 52-11-00 REV. 4, FOUND SATISFACTORY. REPAIR CLASSIFIED AS MINOR AS PER GMM 6-2-100 CRITERIA.SDR SWIA200922363Door · stuckUNABLE TO OPEN MAIN CABIN DOOR. (FLT 6486) OPERATIONAL CHECK NORMAL.SDR AALA20090813SFO01Stop Fitting · wornSFO - CREW DESCRIBED POPPING SOUND COMING FROM THE FORWARD CABIN DOOR AREA. EMERGENCY DECLARED, RETURNED TO SFO WITHOUT INCIDENT. MAINTENANCE WAS ABLE TO DUPLICATE SOUND AND FOUND POPPING SOUND COMING FROM FORWARD EDGE OF LEFT NUMBER ONE DOOR AREA JUST FORWASDR USAA2009081392103Bottle · low pressureFLT 183 - PHX - EMERGENCY EGRESS SYSTEM - CIDS PANEL CAUTION LIGHT ILLUMINATED. MAINTENANCE SERVICED R-1 DOOR ASSIST BOTTLE PER AIRBUS MAINTENANCE MANUAL 52-10-00.SDR USAA2009081392101Bottle · low pressureFLT 1498 - LAX - EMERGENCY EGRESS SYSTEM - CAUTION LIGHT ON CIDS PANEL ILLUMINATED. MAINTENANCE SERVICED L-3 DOOR ASSIST BOTTLE.SDR CALA2009081100451Guide Arm · out of rigL1 DOOR IS DIFFICULT TO OPERATE, ADJUSTED L1 DOOR GUIDE ARM PER MM 52-11-00. OPS CHECKS GOOD.SDR A6WA200940467Latch · inoperativeREQUEST INSP OF MAIN PASSENGER DOOR. WILL NOT LATCH CLOSED FROM INSIDE OR OUTSIDE. (K)SDR ASOA200900889Drag Angle · crackedASD AFT SIDEWALL LOWER DRAG ANGLE CRACKED.SDR AALA20090810TUL02Door Frame · crackedFORWARD ENTRY DOOR PAN (FRAME) CRACKED AT AFT END OF THE NUMBER ONE BEAM. REMOVED AND REPLACED FORWARD ENTRY DOOR FRAME AT UPPER AFT END OF THE NUMBER ONE BEAM PER ESO 80172.SDR IPXA09M56950Skin · damagedINSPECTION TYPE:N/A SMALL BENT AREA AT THE TOP AFT EXTERIOR SURFACE OF THE L1 DOOR. REPAIRED EXTERIOR SURFACE OF THE L1 DOOR PER EO MD11-5210-34409-B / SRM 52-10-01 REPAIR 3.SDR USAA2009081092055Cylinder · low pressureFLT 312 - ATL - EMERGENCY EGRESS SYSTEM - L2 DOOR ASSIST BOTTLE LOW PSI. MAINTENANCE SERVICED L2 DOOR ASSIST BOTTLE.SDR USAA2009081092054Cylinder · low pressureFLT 312-ATL - EMERGENCY EGRESS SYSTEM - R2 DOOR ASSIST BOTTLE LOW PSI. MAINTENANCE SERVICED R2 DOOR ASSIST BOTTLE AS REQUIRED.SDR USAA2009081092050Cylinder · low pressureFLT 150 - PHL - EMERGENCY EGRESS SYSTEM - CHECK DOOR PRESSURE, MESSAGE SHOWING ON CIDS PANEL FOR DOOR 1R. MAINTENANCE SERVICED 1R DOOR TO PROPER LEVEL.SDR USAA2009081092049Cylinder · low pressureFLT 614 - ATL - EMERGENCY EGRESS SYSTEM - R-1 DOOR ASSIST BOTTLE PRESSURE LOW. MAINTENANCE SERVICED R-1 DOOR ASSIST BOTTLE AS REQUIRED.SDR IPXA09M56956Bottle · dischargedL1 DOOR ACCUM DISCHARGED. SERVICED L-1 DOOR PNEUMATIC ASSIST BOTTLE PER MM 12-25-04-3, OPS CK GOOD.SDR SWIA200922789Drag Angle · crackedPASSENGER DOOR DRAG ANGLE CRACKED. (C CHECK) REPAIRED PER REO.
Back to JASC 5210