JASC 5246
Service difficulty reports · 697
Reports filed under 5246 · Fluid Service Doors, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5246' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5246' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2025010649808Plate · corrodedCORROSION FOUND UNDER NUTPLATES FOR LAV SERVICE AREA. 1.REMOVED DAMAGE PARTS I.A.W SRM 51-40-02-0G REV.61 2.FABRICATE P/N(146U8023-2) PER BOEING DWG NO.146U8023 SH 4 REV."-";PL REV."N";PSDL REV."D" AND ORIGINAL PART AS A SAMPLE I.A.W. GMM-MTX CH 9.08 REV.9 REQSDR DALA2024122311921Access Door · puncturedSHIP 3116 WATER SERVICE DOOR 171AL HAS A PUNCTURE IN COMPOSITE ACCESS DOOR TO POTABLE WATER FILLING AND DRAINAGE. CORRECTIVE ACTION: INSTALLED NEW DOOR IAW A319 AMM 52-42. OPS CK GOOD. CDL & PLACARD REMOVED. (6754518)SDR SWAA2025010777816Access Door · damagedELONGATED HOLES ON GROUND SERVICE ACCESS DOOR 114AR LOWER FUSELAGE 2024-763752<[01] REPLACED GROUND SERVICE ACCESS DOOR 114AR LOWER FUSELAGE IAW B737-700 AMM 52-49-02-000-801 AND AMM 52-49-02-400-801 <BR>SEE INDIVIDUAL SIGN OFF BELOW;[02] REPLACED GROUND SERVISDR DALA2024121211687Service Panel · corrodedSHIP 5652 CORROSION ON LAVATORY SERVICE PANEL INNER AREA BTW STA 1680 TO 1700, S29R TO S27R AT AFT CARGO COMPARTMENT. CORRECTIVE ACTION: SUMMARY OF NRC 00510. LAVATORY SERVICE PANEL INNER AREA BTW STA 1680 TO 1700, S29R TO S27R AT AFT CARGO COMPARTMENT WAS REPSDR R61A2024120800573Access Door · corrodedDURING HEAVY CHECK CF III LOWER EXTERNAL SKIN FOUND WASTE WATER DOOR CORRODED BETWEEN FR 88-89 AND BETWEEN STR 25-27 RH. REMOVED AND REPLACED ACCESS DOOR IAW EMB 170/175 AMM 20-10-01SDR R61A2024120700562Door · corrodedDURING HEAVY CHECK WASTE WATER SERVICE DOOR FOUND TO HAVE CORROSION ON OUTER SERVICE. REMOVE AND REPLACED WASTE WATER SERVICE DOOR IAW AMM 53-03-60SDR BAGA2024121000315Door · corrodedHEAVY CHECK SUBMISSION - FOUND CORROSION ON THE LAV WASTEWATER DOOR. REMOVED AND REPLACED THE WASTEWATER DOOR.SDR CALA2024120201382Door · missingPDA 2 REF L/P 3032232, LAVATORY SERVICE DOOR MISSING FROM AIRCRAFT. REF L/P # 3032232 FOR CDL DEFERRAL. THIS LOG TO IDENTIFY PDA ONLY.C/W CDL 52 D FOR MISSING AFT LAV PANEL.SDR VNAA2024112611102Service Door · ground damageOUTER LAV DOOR IMPACTED BY LAV CART (AFT LAV) / PERFORMED PERMANENT REPAIR IAW REO 690-53-51-442.SDR CALA2024111801174Door · missingPDA 1 REF LOG PAGE 9871306 FWD POTABLE WATER SERVICE DOOR FOUND MISSING ON ARRIVAL. BROKEN OFF AT TWO DOOR HINGES. MISSING DOOR PANEL NUMBER IS 191FL, P/N 491Z2301-5, REF DMC-B787-A52-40-12-010-941A-D, ITEM 47. MISSING DOOR OPENING MEASURES 16 INCH BY 16 INCH.SDR DXTA2024111901151Door · openAFTER TAKEOFF DURING THE UPWIND AT APPROXIMATELY 500 FEET, RECEIVED AMBER "SMALL SERVICE DOOR" CAS MESSAGE. QRH PROCEDURES ACCOMPLISHED. RETURNED TO DEPARTURE POINT AND AFTER EXITING AIRPLANE, DISCOVERED SERVICE DOOR FOR NUMBER 3 HYD ACCUMULATOR/BRAKE ACCUMULASDR ASAA2024111254284Doubler · gougedWATER SERVICE DOOR AFT LATCH CONTACT AREA ON INTERNAL SURFACE OF CUTOUT IS GOUGED. GROUNDED - YES. REMOVED AND REPLACED WATER SERVICE DOOR DOUBLER AND COMPLIED WITH EA900ER-53EA-27894 REPAIR.SDR DXTA2024102100888Door · missingLAV SERVICE DOOR MISSING. VIBRATION WAS FELT WHILE CLIMBING FOR 15 - 20 SECONDS THEN STOPPED. HAD A SMALL SERVICE DOOR OPEN CAS MESSAGE. REINSTALLED REPAIRED FAIRING ASSY IAW BD700-A-J53-67-31 FAIRING REPAIRED. . ALL WORK ACCOMPLISHED IAW AMM BD700-A-J53-67SDR DALA2025040302524Door · corrodedWASTE SERVICE DOOR HAS CORROSION. SUMMARY SEE NR FOR ADDITIONAL INFORMATION 001-0088:5360-2017/001 00164 REMOVED AND REPLACED SERVICE DOOR PER A220 AMP 52-47-06. CORROSION LEVEL 1. (LP# 0610687)SDR BAGA202411140283Door · corrodedHEAVY CHECK- RELEASE DATE 11/14/2024- WASTE DOOR 146BR HAS CORROSION, REPLACED DOOR.SDR DALA2024101410088Access Door · crackedSHIP 3144 CRACK POTABLE WATER PANEL 171AL AT LOWER FUSELAGE. CORRECTIVE ACTION: COMPLIED WITH ER/A 611985-14. (0605480)SDR CALA2024100700757Door · missingLAV SERVICE DOOR FOUND MISSING ON ARRIVAL. PICTURE ADDED. REF LOGPAGE 9447573 FOR CORRECTIVE ACTION.SDR DALA2024091609071Door · crackedSHIP 3149 REFUEL PNL DOOR BELLY FAIRING MOUNTED CRACKED. CORRECTIVE ACTION: REPLACED THE BELLY MOUNTED REFUEL PANEL MPN D5331034701200 IAW A319 AMM 52-42. (5538565)SDR CALA2024091300626Door · openUPON ACFT ARRIVAL LEFT FUELING STATION DOOR (521QB) FOUND HANGING OPEN. PANEL INSPECTED, NO DEFECTS NOTED, NO PDA APPARENT. OK TO CONTINUE.SDR CALA2024091000619Service Panel · missingPDA 2 REF LG PG 9183368 WATER SERVICE PANEL MISSING REQUEST DEFERRAL OF WATER SERVICE PANEL, WATER TANK COMPRESSOR DEFERRED IN COMPLIANCE WITH THIS CDL DISPATCH DESK: DD26 NAME: VU DATE: 07-SEP-24-WATER SERVICE DOOR MISSING. CDL 52E APPLIED. WATER SERVICE DOOSDR BAGA2024100700006Access Door · corrodedAFT LWR FUS WASTE ACCESS 146BR, AFT LWR FUS WASTE ACCESS 146BR FOUND CORROSION ON INNER SIDE, WASTE AREA, CORROSION REMOVED/REPAIRD S PER REO 500-52-47-129- HEAVY CHECK SDR SUBMISSION.SDR SWAA2024092034973Door · corrodedPOTABLE WATER SERVICE DOOR PANEL 146AR STOP PADS HAS CORROSION<[01] RESTORED STOP PADS AT POTABLE WATER SERVICE DOOR PANEL 146AR BACK TO A SERVICABLE CONDITION AS PER SOPM 20-30-03; SRM 51-10-02-0G-0; AMM 51-21-41-370-803 AND AMM 51-21-72-370-804.;[02] FINAL ISDR SWAA2024101634309Door · corrodedLAV SERVICE DOOR INNER SURFACE HAS CORROSION ON AFT EDGE<[01] REMOVED AND REPLACED DAMAGED LAV SERVICE PANEL PER AMM 52-49-07-000-801; 52-49-07-400-801; AMM 20-50-11-910-801; PERFORMED A GOOD RESISTANCE CHECK ON BONDING JUMPER PER AMM 52-49-07-400-801 STEP 3.CSDR CALA2024083002330Door · corrodedFWD LAV SERVICE DOOR HAS CORROSION ON DOOR, LATCHES, AND HINGES MARKED FLAGGED #91571 REF AMES NR 172653-0100-0084 ACCOMPLISHED WORK BACKSPACE, SEE PARTIAL WORK SHEET #162 PAGE 1 REPLACED DOOR ASSY P/N 19-5249-3-0048 TAG 3906766 BATCH RC-10222 OF 1 56 AND LATCSDR SWAA2024082628118Door · missingON WALKAROUND CREW REPORTED TO MX LAV SERVICE DOOR MISSING<[01] OK. TO CONTINUE ON CDL PER AUTH #210325;[02] INSTALLED NEW LAV SERVICE DOOR IAW AMM 52-49-07 OPS CHECK GOODSDR SWAA2024092026846Support Bracket · corrodedCORROSION SUPPORT BRACKET LOCATED ON WATER SERVICE DOOR 146AR AT FUSELAGE EXTERIOR 2024-504325<[01] REPLACED SUPPORT BRACKET LOCATED ON WATER SERVICE DOOR 146AR AT FUSELAGE EXTERIOR IAW B737-700 SRM 51-10-02 ITEM 9<BR>SEE INDIVIDUAL SIGN OFF BELOW;[02] CERTIFISDR CALA2024080200347Latch · faultyAFT POTABLE WATER LATCH BROKEN SERCURED DOOR 172AR TOILET SERVICE DOOR CLOSED REF MT 52-028 REF MT 52-028 PANEL 172AR. ISSUE DEFERRAL PER GMM 05-30-05 FOR THE RELAIR/REPLACEMENT WITH A RECHECK PRIOR TO EA FLIGHT CORRECTION. ITS THE TOILET SERVICE DOOR. OK TO ASDR UIEA2024071200648Angle · crackedLHW L/E REFUEL DOOR FWD ZEE FOUND CRACK.(<P>PERFORMED REPAIR AT CRAKCK AREA AS PER RI-57-00-16992 REV.A NO FURTHER DEFECTS NOTED</P>)SDR CALA2024070800148Service Panel · dentedDENT FOUND FORWARD OF AF T LAV SERVICE PANEL, AIRCRAFT WILL BE FERRIED. MAINTENANCE REPAIRED DENT FWD OF AFT LAV SERVICE PANEL AT STA 827 IAW REO-G25108 STAGE 3 AND ECRA 5361-01121 AND RECEIVED FINAL REO-G25108 REV IR. REPAIR AT STA 827 S25L-S26L. THIS IS ASDR SWAA2024080503699Panel · corrodedCORROSION ON INNER SURFACE OF LAV SER PNL 145AL. 8-18<[01] REMOVED AND REPLACED NEW DOOR ASSY P/N 146A7410-6 ISSUE TAG JT2322 AS PER B-737-AMM 52-49-07-400-801; TOOL USED BONDING MILLI-OHMMETER C/ID:168696 DUE DATE:21-MAR-25<BR>01 - REMOVED AND REPLACED PER [RSDR UIEA2024061800534Door · puncturedLH WING, FIXED LEADING EDGE STRUCTURE AREA INNER SIDE FUELING STATION DOOR WITH ONE PUNCTURED.(<P>LH WING, FIXED LEADING EDGE STRUCTURE AREA INNER SIDE FUELING STATION DOOR WAS REPAIRED IAW SRM 57-41-01-2R-1 FIG 201 SHEET 3 PAG 2-4 & SRM 51-70-17-0G-0 PAR 4B FSDR DALA2024061306062Door · crackedSHIP 3140 CRACK DOOR POTABLE WATER PANEL 171AL AT LOWER FUSELAGE. CORRECTIVE ACTION: REPAIRED PER ER/A 618126-14. (0390598)SDR SWAA2024071299794Hinge · corrodedCORROSION HINGE WASTE SERVICE DOOR 145AL AT FUSELAGE EXTERIOR 2024-384025<[01] REPLACED HINGE WASTE SERVICE DOOR 145AL AT FUSELAGE EXTERIOR IAW-B737-800-SRM-51-40-02-0G-0;[02] REPLACED HINGE WASTE SERVICE DOOR 145AL AT FUSELAGE EXTERIOR IAW-B737-800-SRM-51-40-SDR DALA2024061005958Door · bentON ARRIVAL FOUND FUEL SELECTOR PANEL DOOR BENT OPEN. DAMAGE TO THE SLAT SEAL, DAMAGE TO FUEL SELECTOR PANEL, AND DAMAGE TO THE GUARDED SWITCHES. ALL REFUEL ASSOCIATED LATCHES WERE FOUND OPEN / UNLATCHED. REPLACED GUARDED SWITCHES IAW B717 AMM 28-21-14. REPAIRESDR DALA2024052805554Door · corrodedLAV SERVICE PANEL - ACCESS DOOR HAS CORROSION AT INBD HINGE ATTACHMENT AREA. SCEPTRE LOG PAGE ENTERED FOR SDR REPORTING. SUMMARY SEE NR FOR ADDITIONAL INFORMATION 001-0254:2021-2025/003 00220 REMOVED AND INSTALLED NEW DOOR ASSEMBLY PER A220 AMM 52-47-06. (LP# SDR DALA2024052305452Door · crackedAIRCRAFT 3055, AN A319/A320/A321 LAVATORY SERVICE DOOR PANEL NO.172AR WAS FOUND WITH 2 CRACKS ON THE INTERIOR SIDE SKIN AT THE HINGE ATTACHMENTS. THE DAMAGE IS FOUND WITHIN A CONTACT AIRBUS ZONE, MAINTENANCE REACHED OUT TO ENGINEERING FOR REPAIR. THE DAMAGE ISSDR CALA2024052001503Door · missingPDA 2 DURING WALK AROUND FOUND LAV SERVICE DOOR MISSING. LAV SERVICE DOOR MISSING. REQUESTING CDL PIC ATTACHED. LAV SERVICE DOOR PLACED ON CDL DISPATCH DESK: DD22 NAME: SH DATE: 18-MAY-24- CDL 52D APPROVED. TOILET SERVICE DOOR REQUIRES REPLACEMENTSDR SWAA2024071687149Door · corrodedCORROSION INTERNAL SKIN TOILET SERVICE DOOR 145AL AT LOWER FUSELAGE 2024-345277<[01] TOOL USED STEP 4 ULTRASONIC THICKNESS GAGE; P/N: 45 MG; S/ N: 221860711; DUE DATE: 21-NOV-24;[02] EQUIPMENT P/N 45MG; S/N 221861811; DUE DATE 30-NOV-24 WAS USED ON STEP 8;[03]SDR DALA2024051305154Service Panel · corrodedSHIP 6713 CORROSION ON WASTE SERVICE PANEL AT AFT CARGO COMPARTMENT. CORRECTIVE ACTION: SUMMARY OF NRC 00144. DUE TO EXCESSIVE CORROSION INTERNAL DOUBLER, CHANNEL (1 EA), WERE REPLACED PER B757-200 SRM. (0335802)SDR JR2R20240509113Doubler · crackedAFT WASTE DOOR 152AR DOOR CUT-OUT (INTERNAL DOUBLER) CORRODED. REPAIRED.SDR SWAA2024051581207Bonding Strap · corrodedPANEL 145AL TOILET SERVICE DOOR CORRODED AT BONDING STRAP ATTACH POINT. REMOVED DOOR ASSY. PRIMED AND PAINTED DOOR PER [AMM 51-21-99-300-801-NG (DECORATIVE EXTERIOR PAINT SYSTEM APPLICATION - PERMANENT) REMOVED BONDING STRAP, REMOVED CORROSION, OUT OF ALLOSDR DALA2024050304918Door · crackedAIRCRAFT 3051, LAVATORY SERVICE DOOR PANEL NO.172AR WAS FOUND WITH 2 CRACKS ON THE INTERIOR SIDE SKIN AT THE HINGE ATTACHMENTS. CORRECTIVE ACTION: REMOVED ANY DAMAGED PILES INCREMENTALLY ON A PLY-BY-PLY BASIS ENSURING ALL DAMAGE IS REMOVED FULLY. ACCOMPLISHED SDR CALA2024042901255Skin · corrodedB757-53-3-0481 - CORROSION ON SKIN AROUND LAVATORY SERVICE DOOR, AFT LOWER FUSELAGE. ACCOMPLISHED WORK PER UAL EC/RA #5360-01795 AND VT MAE EA 757-53 60-13-A3566 REV-, FAA 8100-9 APPROVAL ATTACHED. RII VERIFIED JOB PERFORMEDSDR SWAA2024042577993Door · missingAFTER LANDING IN OMA; ON POST FLIGHT INSPECTION DISCOVERED LAVATORY SERVICE DOOR MISSING.<[01] OK TO CONTINUE PER CDL 52-40-8. AUTHORIZATION #190049.;[02] INSTALLED NEW SERVICE DOOR FOR EXTERIOR LAV SERVICE DOOR IAW AMM 52-49-07SDR SWAA2024052377743Door · corrodedCORROSION AT TOILET SERVICE DOOR 145AL BONDING FASTENER ATTACH AREA SURFACE.<[01] CORROSION FOUND OUT OF LIMITS PER SRM 52-40-01-1A-4; REPLACED AND INSTALLED NEW TOILET SERVICE DOOR PER AMM 52-49-07-000-801 AND SRM 51-40-02-0G-0.;[02] VERIFIED STEP 1.SDR REXA2024080500619Diaphragm · corrodedSTRUCTURE INSIDE FWD TOILET SERVICE DOOR IS CORRODED. REMOVED AND REPLACED DIAPHRAGMS AND BRACKET IAW CRJ 900SRM 51-40-11-001-001-A01 AND 51-42-06-001-001-A01.SDR JR2R20240401876Service Door · corrodedLAV SERVICE DOOR CORRODEDSDR REXA2024073000577Angle · corrodedFWD WATER WASTE DOOR INTERNAL IMPACT ANGLE IS CORRODED REMOVED FWD WATER WASTE DOOR INTERNAL IMPACT ANGLE FOR REPLACEMENT IAW CRJ900 SRM 51-42-06-001-001-A01 INSTALLED NEW SERVICEABLE IMPACT ANGLE P/N SH670-32310-1 IAW CRJ900 SRM 51-42-06-001-001-A01, AND CSDR SWAA2024042567393Door · corrodedCORROSION TOILET SERVICE DOOR 145AL AT FUSELAGE EXTERIOR. PERFORMED REPAIR ON TOILET SERVICE DOOR 145AL LOCATED AT FUSELAGE EXTERIOR. IAW B737-700 SRM 52-40-01-2R-8 REPAIR 8.SDR JR2R20240322526Door · corrodedSKIN DOUBLER CORRODED AT LAV WASTE BOX . P/N 170-66931-001
Back to JASC 5246