SDR JR2R20230213793Beam · corrodedFLOOR BEAM CORRODEDAT RBL11 FWD OF FR85SDR JR2R20230213795Doubler · corrodedFLOOR WEB ON TOP OF FR87 CORRODED BETWEEN RBL12 THRU RBL42SDR JR2R20230213836Gusset · corrodedFLOOR GUSSET AT FR90 RBL24 CORRODEDSDR JR2R20230213794Beam · corrodedFLOOR BEAM AT RBL11 CORRODED FWD OF FLOOR BEAM 87SDR JR2R20230213797Beam · corrodedFLOOR BEAM AT LBL11 CORRODED AT FR87SDR JR2R20230213791Doubler · corrodedFLOOR WEB ON TOP OF FR14 CORRODED BETWEEN RBL35 AND RBL48SDR JR2R20230213790Beam · corrodedFLOOR BEAM 14 CORRODED BETWEEN RBL11 THRU RBL16SDR CALA2023021300425Unknown · crackedLOWER FUS.CENTER WING BOX CTR BULKHEAD VAPOR BARRIER UPPER CHORD ATTACHED ANGLE CRACKED @ APPROX. LBL6, STA 663.75 REF. AAR N/R:9515623. REPAIRED WING CENTER BULKHEAD VAPOR BARRIER UPPER CHORD ATTACHED ANGLE LBL 6, STA 663.75SDR CALA2023021300424Unknown · crackedLOWER FUS.CENTER WING BOX CTR BULKHEAD VAPOR BARRIER UPPER CHORD ATTACHED ANGLE CRACKED @ APPROX. RBL6 , STA 663.75 REF. AAR N/R:9515625 REPAIRED WING CENTER BULKHEAD VAPOR BARRIER UPPER CHORD ATTACHED ANGLE RBL 6, STA 663.75.SDR REXA2022022400242None · crackedR/H AFT TRU LATCH CUTOUT ANGLE IS CRACKED. INSTALLED NEW AVIONIC BAY DOOR LANDING ON RH SIDE BETWEEN FS 193 TO 168 IAW CRJ 900 SRM 51-42-06-001-001-A01 AND 51-42-13-001-001-A01SDR REXA2022022400241None · crackedR/H FWD EQUIPMENT BAY FLOOR IS CRACKED AT F.S. 193.00. INSTALLED NEW ELECTRIC BAY WEB DOUBLER IAW CRJ-900 SRM 51-42-06-001-001-A01. REF. CRJ-900 SRM 53-11-43-201-001-A01SDR SWAA2023022202392Web · elongatedFLIGHT DECK REPAIR EA 21-153-00734 HAS 2 ELONGATED HOLES AT B/S 260 MARKED IN RED.<[01] REAMED TWO HOLES NEXT OVER-SIZE BY 1/32 INCHES IN ACCORDING EA M-21-153-00734 SWA REPAIR FLIGHT DECK FLOOR WEB DENT REPAIR AT BS 260(TTG8Q00HQESA) STEP 16; NOTE ONE.;[02] PSDR R61A2023022000158Shear Tie · corrodedDURING GROUND INSP FOUND BROWN WATER COMING FROM BELOW AFT CARGO AREA. UPON FURTHER INSP FOUND WASTE SERVICE BOX DRAIN TUBE CLAMP BROKEN. ALSO FOUND 2 EA SHEAR CLIPS CORRODED,WASTE SERVICE BOX DELAMINATED AND SKIN CORRODED. REMOVED AND REPLACED SHEAR CLIPS ANDSDR FDEA202302120250Splice · corrodedLOWER CENTER CARGO COMPARTMENT BILGE STATION 5-62, LONGERON 48 RIGHT HAND SPLICE FITTING FOUND WITH COROSSION. LOWER CENTER CARGO COMPARTMENT BILGE STATION 5-62, LONGERON 48 RIGHT HAND CORRODED SPLICE FITTING REMOVED AND REPLACED SPLICE AS PER SRM 51-33-01SDR CALA2023021300418Floor Support · corrodedCORRODED FLOOR SUPPORT AT STA 440 LEFT SIDE OUTBOARD AREA BLENDED FLOOR SUPPORT L/H SIDE AT STA 440, FOUND TO BE OUT OF LIMITS, REPLACED ON AMES DOC #47541FAB02 AND ECRA 5335-01123SDR SWAA2023032102054Intercostal · crackedCRACK WEB - INTERCOSTAL LOCATED BETWEEN BS847 TO BS867 CEILING AREA AFT CARGO COMPARTMENT 2023-116760<[01] REPLACED WEB - INTERCOSTAL (1 E/A) AND FASTENERS LOCATED BETWEEN BS847 TO BS867 CEILING AREA AFT CARGO COMPARTMENT IAW B737- 700 SRM 51-10-02 PARAGRAPH 9SDR SWAA2023032102057Intercostal · crackedCRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BTW BS277 TO BS294.5 BL0 FWD GALLEY AND LAV 2023-116762<[01] REPLACED WEB- INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS277 TO BS294.5 BL0 FWD GALLEY AND LAV IAW B737-700 SRM 51-40-02; SRM 51-10-02 ITEM 9 AND DWSDR SWAA2023032002086Intercostal · crackedFWD CABIN FLOOR INTERCOSTAL AT 312-328 RIGHT B/L 28 IS CRACKED<[01] REMOVED INTERCOSTAL AT FWD CABIN FLOR STA 312 TO 328 RIGHT BL 28 FOR CRACKED SRM 51-40-02 -0G-0;[02] VERIFIED STEP 1AND OK TO INSTALL NEW INTERCOSTAL;[03] RECEIVED NEW PART PO#2002351) INSTALLSDR SWAA2023032002014Frame · crackedCRACK FRAME 259.5 AT LEVEL STR8L AT PASSENGER CABIN 2023-106328<[01] TOOL USED EDDY CURRENT INSTRUMENT P/N NORTEC500D S/N N500X12101V022235 DUE DATE 03-AUG-2023.;[02] REPAIRED FRAME ON BS259.5 AT LEVEL STR8L AT PASSENGER CABIN I.A.W. EA 23-153-00632 AND EA 23-SDR AALA202302212891Door Sill · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON RIGHT AFT PASSENGER / CREW DOOR CUT OUT LOWER SILL AT FR 68 AND S23R. MAINTENANCE REPAIRED LOWER SILL PER SRM 53-41-14-300-001, REPAIR PRINCIPLE 5, FIGURE 001, SHEET 01 AND SHEET 03.SDR SWAA2023021502209Filler · missingEXTERNAL POWER RECEPTACLE DOOR CUTOUT EXISTING CENTER LOWER REPAIR DOUBLER HAS MISSING MATERIAL.<[01] REMOVED AND REPLACED FILLER #13 FROM PREVIOUS REPAIR IAW SRM 53-10-15-2R-4SDR IPXA2023021190887Frame · noneINSPECTION TYPE:SEG1*MAJOR REPAIR* EXISTING REPAIR FOUND AT AFT CARGO COMPT FRAME STA 1360, S-26L.ACCOMPLISHED REPAIR PER UPS EO# B757-5310-85613-A AND EA# 757-5360-27-A3128 REV-SDR IPXA2023021190886Frame · noneINSPECTION TYPE:SEG4*MAJOR REPAIR* UPON INSPECTION FOR EO (B757-5310-73926-A) FOUND AN EXISTING REPAIR AT STA 1240 RH STR 25R-27RREPLACED REPAIR PER UPS EO B757-5310-85398-A AND VT MAE EA 757-5360-A3125 AND UPS RCD 266225SDR IPXA2023021190895Frame · dentedINSPECTION TYPE:SEG4*MAJOR REPAIR* STA 1360 RH STA 26R-25R FRAME HAS 2 DENTS OUT OF LIMITSACCOMPLISHED REPAIR ON FRAME PER UPS EO B757-5310-85838-A AND VT MAE EA 757-5360-27-A3130 AND UPS RCD 266454SDR CALA2023021300408Unknown · corroded(SUPPORT TASK) MAIN CABIN CREASE BEAM INNER CHORD CORRODED AT AP PROX STA 755 RBL60. TRANSCRIBED FROM HAECO GSO NRC# 9284229 REMOVED/BLENDED CORROSION, FOUND TO BE OUT OF LIMITS PER B757-20 ON CUT EDGES AND FASTENER HOLES, ALODINED, PRIMED AND APPLIED CI 0 SRSDR SWAA2023031301699Intercostal · crackedMAIN CABIN INTERCOSTAL BETWEEN STA 277-294.5 BL 0 CRACKED<[01] REMOVED INTERCOSTAL DAMAGED AT MAIN CABIN STA. 277 TO 294.5 BL '0'. REF. SRM. 51-40-02;[02] LOCATED AND DRILLED NEW MAIN CABIN INTERCOSTAL AT STA 277-294.5 BL0 REF SRM 51-40-05-0G-0;[03] VERIFIED SSDR SWAA2023031301704Angle · crackedMAIN CABIN INTERCOSTAL ANGLE BETWEEN STA 380-400 RBL 10' CRACKED<[01] REMOVED INTERCOSTAL ANGLE DAMAGED AT MAIN CABIN STA. 380 TO 400 RBL. 10'. REF. SRM. 51-40-02;[02] LOCATED & DRILLED NEW ANGLE BETWEEN STA. 380-400; RBL 10; AS PER SRM 51-40-05; & DWG. 143A54SDR SWAA2023031301703Angle · crackedMAIN CABIN INTERCOSTAL ANGLE BETWEEN STA 380-400 BL 0' CRACKED<[01] REMOVED INTERCOSTAL ANGLE DAMAGED AT MAIN CABIN STA. 380 TO 400 BL. '0'. REF; SRM. 51-40-02;[02] VERIFIED STEP 1;[03] OK TO INSTALL NEW INTERCOSTAL;[04] INSTALLED INTERCOSTAL ANGLE AT MAIN CABSDR IPXA2023022191207Seat Track · damagedINSPECTION TYPE:C15LBL 24.75 SEAT TRACK I/B FLANGE AT STA 1215 WITH 1 FASTENER HOLE OUT OF ROUND.REPAIRED IAW VT MAE# 757-5360-27-A3146SDR SIMA20230210001Seal Rest · corrodedFWD CARGO DOOR LOWER CUTOUT CORRODED AT 6 SILL ATTACHMENT NUT PLATES.(LEVEL 2 CORROSION) -C/A-RAR CORRODED FWD CARGO DOOR LOWER FWD CUTOUT REST IAW EMB 175 AMM 20-10-01, EMB 175 AMM 53-21-29 AND EMB 175 SRM 51-40-08. PERFORMED PERMANENT REPAIR TO CORRODED FWD SDR IPXA2023021190870Frame · noneINSPECTION TYPE:SEG1*MAJOR REPAIR* EXISTING REPAIR FOUND FRAME 1320, STR 25R TO 26R.ACCOMPLISHED REPAIR IAW UPS EO B757-5310-85615-ASDR KCSA202302101004Shear Tie · crackedMANDATORY: PERFORM EO- EO 5312-22-01 (ENGINEERING ORDER) REV. 00 AD 2021-17-06(G), RB 747-53A2904 - STA 1000 FRONT SPAR SHEAR TIE AND INTERCOSTAL LUG FITTING INSPECTION AND REPAIR. NOTE: SDR IDENTIFIED FOR BS 1000 LBL 33.99 ADJACENT TO CENTER WING TANK UPPER SDR VNAA202302100004Doubler · corrodedANTENNA DOUBLER IS CORRODED BETWEEN F.S. 280 TO F.S. 295 AND AT STGR 27
CORRECTIVE ACTION REMOVED ANTENNA DOUBLER BETWEEN F.S.295-F.S.310 IAW CRJ 700 SRM 51-42-06-001-001-A01. INSTALLED NEW ANTENNA DOUBLER BETWEEN F.S.295-F.S.310 IAW CRJ 700 SRM 51-42-06-SDR VNAA202302100002None · noneSB_670BA-53-040-REQ (FUSELAGE CENTER
FUSELAGE, PRIMARYSTRUCTURE FS280.00
TO FS295.00 INSPECTION AND REINFORCEMENT OFLINTEL STRINGER 3 OF THE MAIN PASSENGER DOOR)
CORRECTIVE ACTION: C/W SB_670BA-53-040-REQ (FUSELAGE CENTER FUSELAGE, PRIMARY STRUCTURE
FS280.SDR SWAA2023032001189Frame · crackedCRACK FRAME ON BS 312 BTW STR 5L TO 6L FWD GALLEY AND LAV 2023-106300<[01] REPAIRED LOCATED FRAME ON BS 312 BTW STR 5L TO 6L FWD GALLEY AND LAV IAW B737-700 EA NO:M-22-153-01244 REV: B.<BR>SEE INDIVIDUAL SIGNOFFS BELOW;[02] REPAIRED LOCATED FRAME ON BS 312 BTWSDR SWAA2023031301498Frame · crackedCRACK ON FRAME BS 312 BETWEEN STR-4L AND UPPER MAIN SILL .<[01] REPAIRED FRAME BS 312 BETWEEN STR-4L AND UPPER MAIN SILL ON FAULT #[TTG8Q00HTL5N];[02] VERIFIED ITEM 1 CORRECTIVE ACTIONS. <BR>VERIFIED MEASUREMENTS.SDR IPXA2023020990834Frame · noneINSPECTION TYPE:SEG4*MAJOR REPAIR* UPON INSPECTION FOR EO (B757-5310-73926-A) FOUND AN EXISTING REPAIR AT STA 1560 LH S25L-S27LACCOMPLISHED ALTERNATE INSPECTION PER UPS EO B757-5310-26668-C, UPS RCD 266226 AND VTMAE 757-5360-27-A3126 REV-SDR CALA2023021000401Angle · crackedLOWER FUS.CENTER WING BOX CTR BULKHEAD VAPOR BARRIER UPPER CHORD ATTACHED ANGLE CRACKED @ APPROX. LBL6, STA 663.75 REF. AAR N/R:9515623. REPAIRED WING CENTER BULKHEAD VAPOR BARRIER UPPER CHORD ATTACHED ANGLE LBL 6, STA 663.75 PER REF.B737 SRM 57-10-10- 2R-5,RESDR FDEA202302090239Unknown · unknownDURING INSPECTION OF APU OIL LEVEL FOR SERVICE CHECK, LIFT TRUCK FORWARD BARRIER HIT PANEL LOCATED IN FRONT OF 313AL DOOR DUE TO MALFUNCTION OF THIS LIFTRUCK. EA: G-5310-T0372876 P2 C/W WITH STEPSDR VNAA202302090003Frame · corrodedDISCREPANCY: F.S. 1088.20 FRAME IS CORRODED BETWEEN STGR 26R TO STGR 26L.
CORRECTIVE ACTION:
COMPLIED WITH REPAIR TO F.S. 1088.20 FRAME BETWEEN STGR 26R TO STGR 26L IAW OLIVER WYMAN CAVOK EA 23-C7-53-0116, DATED 2/26/23, REV IR.SDR VNAA202302090002Frame · corrodedF.S. 333 FRAME IS CORRODED BETWEEN STGR 27 TO STGR 26L.
CORRECTIVE ACTION:
REPAIRED FS 333 LOWER FRAME SEGMENT IAW CRJ-700 SRM 53-00-06-201-006-A01.SDR VNAA202302090001None · corrodedNUT PLATE CHANNEL BETWEEN F.S. 1000 TO F.S. 1015 AND BETWEEN STGR 27 TO STGR 26L IS CORRODED.
CORRECTIVE ACTION:
INSTALLED NEW NUT PLATE CHANNEL P/N MM670-70327-001 BETWEEN F.S. 1000 TO F.S. 1015 AND BETWEEN STGR 27 TO STGR 26L IAW CRJ700 SRM 51-42-06-0SDR IPXA2023021090863Floor Panel · damagedINSPECTION TYPE:CK1C*MAJOR REPAIR* MDC PANEL 241LJ IS BROKEN.FABBED I.A.W. SREO A300-5220-40552-B.SDR IPXA2023021090862Floor Panel · damagedINSPECTION TYPE:CK1C*MAJOR REPAIR* MDC PANEL 261 RF IS DAMAGED.FABBED I.A.W. SREO A300-5320-40542-B.SDR IPXA2023021090861Unknown · damagedINSPECTION TYPE:CK1C*MAJOR REPAIR* MDC PANEL 261 KF IS BROKEN.FABBED I.A.W. SREO A300-5320-40552-B.SDR IPXA2023021090860Floor Panel · damagedINSPECTION TYPE:CK1C*MAJOR REPAIR* MDC PANEL 261 LF IS DAMAGED.FABBED I.A.W. SREO A300-5320-40552-B.SDR IPXA2023021090859Floor Panel · damagedINSPECTION TYPE:CK1C*MAJOR REPAIR* MDC PANEL 251 CN IS BROKEN.FABBED I.A.W. SREO A300-5320-40552-B.SDR IPXA2023021090858Floor Panel · damagedINSPECTION TYPE:CK1C*MAJOR REPAIR* MDC PANEL 252 CN IS DAMAGED.FABBED I.A.W. SREO A300-5320-40552-BSDR FDEA202302080226Track · crackedLOWER CENTER CARGO COMPARTMENT STATION 1701, X-75 CEILING AREA SEAT TRACK FOUND WITH CRACK. LOWER CENTER CARGO COMPARTMENT CEILING AREA, CRACKED SEAT TRACK AT STATION 1701, X-75.25 REPAIRED BY SECTIONAL SEAT TRACK REPLACEMENT FROM STATION 1711 TO EXISTING SDR IPXA2023020890776Adapter · brokenINSPECTION TYPE:CK1CMDC SEAT TRACK ADAPTER BROKEN BETWEEN Y1959 AND Y2462 AT FRAME 33.REMOVED AND REPLACED SEAT TRACK ADAPTER IAW-SRM 51-40-21.