JASC 5310
Service difficulty reports · 38,528
Reports filed under 5310 · Fuselage Main, Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5310' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5310' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA202301184878Crease Beam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON PASSENGER CABIN FORWARD ENTRY FLOOR STRUCTURE CREASE BEAM INNER CHORD LOCATED AT BS 344 AND LBL 60. REPLACED CHORD PER SRM 53-10-15-1A-1 4.SDR SIMA202301119001Window Frame · crackedCOCKPIT LH FRAME 08 BELOW LH DV WINDOW IS CRACKED AT UPPER RIVET HOLE. (MAJOR REPAIR) -C/A-REMOVED AND REPLACED LH COCKPIT FRAME 08 BELOW LH DV WINDOW IAW EMB 170 SRM 51-40-08.SDR SIMA20221219002Window Frame · crackedCOCKPIT RH FRAME 08 BELOW RH DV WINDOW IS CRACKED AT UPPER RIVET HOLE. (MAJOR REPAIR) -C/A-REMOVED AND REPLACED RH COCKPIT FRAME 08 BELOW RH DV WINDOW IAW EMB 170 SRM 51-40-08.SDR AALA202302098410Door Sill · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON LEFT AFT PASSENGER / CREW DOOR CUT OUT LOWER SILL BETWEEN FR 66 AND FR 68 AT S23L. MAINTENANCE REPLACED LOWER SILL PER SRM 51-72-11.SDR SWAA2023020182960Angle · corrodedCORROSION ANGLE LOCATED BETWEEN BS767 TO BS787 AND RBL21; WL156 AFT CARGO COMPARTMENT 2022-695520<[01] REPLACED ANGLE LOCATED BETWEEN BS767 TO BS787 AND RBL21; WL156 AFT CARGO COMPARTMENT IAW B737-700 SRM 51-10-02 Ï¿½TEM 9 AND DWG #146A8123 SHEET 16 REV -.<BR>SDR SWAA2023012583035Stub Frame · crackedFWD GALLEY DOORWAY FWD STUB FRAME CRACKED AT STR 17R MOP SILL ATTACH POINT; MARKED<[01] NDT HFEC INSPECTED MARKED STUB FRAME AREA; IAW 737 NDTM PART 6 51-00-00 PROC 23. CRACKS; .250' LONG; NOTED AT FASTENER HOLE.<BR>EQUIP USED: NORTEC 500D IS000681 DUE 02/23;[SDR YENA2022122001277Doubler · corrodedDURING HEAVY MAINTENANCE, CORROSION IN THE INTERNAL DOUBLER OF WASTE PANEL. CORRODED DOUBLER WAS REMOVED IAW SRM 51-12-03, 51-10-03. EVALUATED OUT OF LIMITS. REPAIRED IAW SRM 53-23-60- R51.SDR DALA2022121908179Door Frame · corrodedCORROSION ON LOWER DOOR JAMB EXTRNAL SURFACE FROM STA 370 TO 427 AT FWD CARGO COMPARTMENT (CCD). SUMMARY LEVEL CORROSION 2. DOOR JAMB EXTRNAL SURFACE FROM STA 370 TO 427 WAS REPLACED PER B717-200 51-40-08-0G PAR 3 AND SRM 51- 41-02-0G AND 51-41-05-0G. (LP #254SDR DALA2022121908178Door Frame · corrodedCORROSION ON AFT CARGO COMPARTMENT DOOR JAMB REPAIR DOUBLER AT STA Y=954 BTW LONGERON PROJECTION 27RH AND 26RH. SUMMARY OF NRC 00138: CORROSION LEVEL 2. AFT CARGO COMPARTMENT DOOR JAMB REPAIR DOUBLER AT STA Y=954 BTW LONGERON PROJECTION 27RH AND 26RH WAS REPLASDR CALA2022121903431Floor Support · corrodedFLOOR SUPPORT Y1292 FR68-FR69 CORRODED AT FR68. REMOVED AND REPLACED FLOOR SUPPORT Y1292 FR68 TO 69 I.A.W SRM 51 -42-11-001 AND APPLIED TOP COAT I.A.W SRM 51-23-11. EMP: V934614 WC: 41180 STA: ST ENG BFMSDR CALA2022121903430Floor Support · corrodedFLOOR SUPPORT Y1292 FR66-FR68 HAS CORROSION AT FR66 AND FR68. REMOVED AND REPLACED FLOOR SUPPORT Y1292 FR66 TO FR68 I.A.W SRM 51-42-11 AND APPLIED TOP COAT I.A.W SRM 51-23-11. EMP: V934614 W C: 41184 STA: ST ENG BFMSDR SWAA2023012682794Door Frame · crackedFWD ENTRY DOORWAY UPPER FRAME CRACK; BS 312; STR 5L; IB RADIUS; MARKED<[01] FWD ENTRY DOORWAY UPPER FRAME AT BS 312; STR 5L; WILL BE REPAIRED ON FAULT [TTG8Q00GQLVU];[02] FWD ENTRY DOORWAY UPPER FRAME AT BS 312; STR 5L; WILL BE REPAIRED ON FAULT [TTG8Q00GV0TF]SDR DALA2022122708401Doubler · damagedERA 604453-14 REPAIR TO AFT WASTE BOX DOUBLER AND DOOR HAS FOLLOW ON ACTIONS REQUIRED.ACCOMPLISH SECTION II REPETITIVE INSPECTIONS EVERY 850 FH AFTER SECTION I. ACCOMPLISH SECTION III DTE RESTRICTION WITHIN 8500 FL OF SECTION I. OPERATION BEYOND 8500 HOURS REQSDR CALA2022121903423Fitting · crackedF.O LOWER WINDHISELD CONTINUITY FITTING AT LOWER CENTER POST PRODUCED A CRACK INDICATION DURING THE HFEC INSPECTION. GENERATED A T HAECO LCQ PER NR 9298244 (32244) BY V061690 EA 5310-07675 AD 2 020-17-03. THE FRONT WINDSHIELD FRAME RH CONTINUITY FITTING, ACCOMSDR 2022F00521Door Frame · damagedELONGATED DAMAGED HOLES FOUND AT MULTIPLE LOCATIONS ON BS
348.2 DOOR FRAME, FORWARD SIDE PER BOEING SB 737-53A1240 AND
SB 737-53-0029 CRITERIA.SDR F3LA2022201200167Plate · crackedDISCREPANCY: REFERENCE PEMCO N/R#13253.0397 AFT WET AREA, LEFT SHEAT PLATE CRACKED. CORRECTIVE ACTION: REMOVED AD REPLACED CRACKED SHEAR PLATE AT AFT WET AREA L/H IAW A320 SRM 51-72-911-001.//ENDSDR DALA2022121908226Door Frame · frozenR4 DOOR DIFFICULT TO INSERT SAFETY. MAY BE DUE ICING AT BLOCK-IN. FOUND ICE ON DOOR SILL AND FRAME. REMOVED ICE, DOOR OPS NORMAL.SDR CALA2022121903420Web · corrodedFWD CABIN WEB AT -Y1732 CORRODED AT FR20. FWD CABIN WEB AT -Y1732 REMOVED AND REPLACED IAW SRM 51-42-11/00 1 AND APPLIED TOPCOAT IAW SRM 51-23-11. EMP: V934614 WC: 41297 S TA: ST ENG BFMSDR CALA2022121903419Floor Support · corrodedFLOOR SUPPORT Y515 FR68 TO FR70 CORRODED AT 2 LOCATIONS REMOVED/REPLACED SUPPORT Y515 FR68 TO FR70 P/N D5347209400400 BT CH 0003912854 IAW SRM 51-72-11-911-001. EMP: V934337 WC: 41168 S TA: ST ENG BFMSDR CALA2022121903418Floor Support · corrodedFLOOR SUPPORT Y515 FR64 TO FR67 CORRODED AT 2 LOCATIONS REMOVED/REPLACED FLOOR SUPPORT Y515 FR64 TO FR67 P/N D5347209400 800 BTCH 0003809500 IAW SRM 51-72-11-911-001. EMP: V934337 WC: 4 1167 STA: ST ENG BFMSDR CALA2022121903416Floor Support · corrodedFLOOR SUPPORT Y765 FR66 TO FR70 CORRODED AT 2 LOCATIONS FLOOR SUPPORT Y765 FR66 TO FR70 REMOVED TO BE FOUND OUT OF LIMIT 6 S IAW 53-00-14-283-002 L=1.500" W=2.00", D=1.10" RECEIVED NEW FL OOR SUPPORT P/N D5347219220000, BTCH 0004031110, AND INSTALLED NEW FLOORSDR CALA2022121903415Floor Support · corrodedFLOOR SUPPORT -Y1292 FR66-FR68 CORRODED AT FR66 AND FR68. FLOOR SUPPORT -Y1292 FR66-FR68 REMOVED IAW SRM 51-42-11, FOUND T WC: 41175 STA: ST ENG BFM O BE OUT LIMITS IAW SRM TASK 53-00-14-283-002 L=1.500", W=1.4--" , D=-,078" T93986. RECEIVED NEW FLOOR SUPPORT SDR JR2R20221216913Angle · corrodedFLOOR ANGLE, FWD SIDE OF FR16 AT RBL28 CORRODEDSDR JR2R20221216922Shear Panel · corrodedFLOOR WEB AT FR87 FROM LBL11 TO LBL40 CORRODEDSDR JR2R20221216943Gusset · corrodedFLOOR GUSSET AT FR90 RBL34 CORRODEDSDR SWAA2023020781706Doubler · crackedCRACK ON CUT OUT SURROUND DOUBLER OF ELECTRICAL GROUND POWER RECEPTACLE OF ACCESS PANEL 114AR 2022-696734<[01] EDDY CURRENT EQUIPMENT P/N: NORTEC500D; S/N: N500X11290U021704; DUE DATE: 01-FEB-23.;[02] PERFORMED REPAIR ON SURROUND DOUBLER OF FRAME OUTER CHORD ASDR SWAA2023013081535Structure · crackedCRACK FLOOR STRUCTURE LOCATED ON LH INNER CHORD AT LEVEL OF STR 17L BS 303.9 AT FWD GALLEY AREA 2022-691828<[01] REPLACED INNER CHORD AND ANGLES (2EA) LOCATED AT LEVEL OF STR 17L BTW BS 360 AND BS 259.5 AT FWD GALLEY AREA IAW B737-700 SRM 51-10-02 ITEM 9 AND DSDR SWAA2023013081541Stub Frame · crackedCRACK SERVICE DOOR FWD ; LOWER STUFF FRAME LOCATED AT BS 294.5 BTW STR 14R TO STR 17R AT FWD GALLEY AREA . PERFORMED REPAIR SERVICE DOOR FWD ; LOWER STUFF FRAME LOCATED AT BS 294.5 BTW STR 14R TO STR 17R AT FWD GALLEY AREA IAW B737 SRM 53-10-15-2R-7 REPAIR 7SDR SWAA2023012582282Stub Frame · crackedFWD CABIN SERVICE DOOR SURROUND LOWER STUB FRAME CRACKED BS294 RBL55 WL209.<[01] THIS DISCREPANCY WILL BE ACCOMPLISHED ON CARD TTG8Q00GQW4V;[02] VERIFIED CORRECTIVE ACTION 1 AND MEASUREMET TABLE.SDR CALA2022121603404Beam · corrodedMAIN CABIN FLOOR STRUCTURE. FR 66 BEAM AT Y1292 CORRODED. () REMOVED CORROSION I.A.W 51-74-00 L= 0.657", W= 0.740", D= 0.035" BEAM FROM MAIN CABIN FLOOR STRUCTURE I.A.W SRM 51-42-11 EMP#: V9 FOUND OUT OF LIMITS I.AW 53-00-14-283-002, REMOVED LH OTBD BEAM 36321SDR CALA2022121603403Beam · corrodedMAIN CABIN FLOOR STRUCTURE. BEAM FWD OF FR 68 AT -Y969 AT FASTEN ER HOLE CORRODED. () REMOVED AND REPLACED FLOOBEAM FWD OF FR68 IAW SRM 51-42-11 SEE F ORM 44-008 ATTACHED EMP#: V936761 WORK ACCOMPLISHED AT ST ENGINE ERING OF MOBILE AT BFM ON NR#: 48036SDR CALA2022121603402Beam · corrodedMAIN CABIN FLOOR STRUCTURE. BEAM AFT OF FR 66 AT -Y969 CORRODED. () REMOVED AND REPLACED FLOORBEAM AFT OF FR66 IAW SRM 51-42-11 SEE FORM 44-008 ATTACHED EMP#: V936761 WORK ACCOMPLISHED AT ST ENGIN EERING OF MOBILE AT BFM ON NR#: 48037SDR CALA2022121603399Floor Support · corrodedFLOOR SUPPORT Y765 FR66 TO FR70 CORRODED AT 2 LOCATIONS FLOOR SUPPORT Y765 FR66 TO FR70 REMOVED TO BE FOUND OUT OF LIMIT 6 S IAW 53-00-14-283-002 L=1.500" W=2.00", D=1.10" RECEIVED NEW FL OOR SUPPORT P/N D5347219220000, BTCH 0004031110, AND INSTALLED NEW FLOORSDR CALA2022121603397Dummy Rail · corrodedFWD CABINDUMMY RAIL FR12 TO 16, Y503.2 CORRODED AT FR16 REMOVED OLD RAIL AND FABRICATE NEW RAIL Y503.2 IAW, AIRBUS DRAWI NG D5311287 AND INSTALLED IAW SRM 51-42-11. EMP#: V936191 STATIO N: BFM WC# 41296SDR SWIA2023011967127Pressure Deck · crackedPRESSURE DECK WAS CRACKED AT BS 461 BETWEEN BL 0 & RBL 9. REPAIRED PRESSURE DECK IAW REO 601R-53-41-2598 REV -. LEAK CHECKS GOOD.SDR AALA202212299457Trans Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: RIGHT TRANSITION PANEL CORRODED BETWEEN STA 747 AND 767 AND RIGHT BUTT LINE 22. BLENDED REPAIR PER SRM 51-10-02.SDR AALA202212299320Trans Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: FORWARD CARGO LEFT TRANSITION PANEL CORRODED LOCATED AT STA 500A TO 500F AND LEFT BUTT LINE 23. REMOVED AND REPLACED LEFT TRANSITION PANEL.SDR AALA202212298532Trans Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: LEFT TRANSITION PANEL CORRODED BETWEEN STA 727J THROUGH 747 AND LEFT BUTT LINE 22. BLENDED REPAIR PER SRM 51-10-02.SDR FDEA202212143026Beam · crackedFWD CARGO COMPT AT STA. 595 AFT PRESSURE BULKHEAD BEAM AT X= -6 AND Z= -80 HAS A 1.5 IN. CRACK AT THE LOWER RADIUS. REPAIRED FWD CARGO COMPT. STA 595 AFT PRESSURE BULKHEAD BEAM AT X= -6 AND Z= -80 REF SRM 53-20-08-2R FIG. 201. "MAJOR REPAIR"SDR YADA202212164001Latch · out of adjustPILOT REPORTED SMOKE FROM RT CIRCUIT BREAKER PANEL, NR 2 AVIONICS BREAKER MELTED, COMM 2 AND ADF 1 BREAKERS ALSO SMOKED. AIRCRAFT RETURNED TO AIRPORT OF ORIGIN. PILOT ALSO REPORTED THAT SMOKE ABATED AFTER NR 2 AVIONICS BREAKER PLUNGER POPPED OUT. MAINTENANSDR CALA2022121403378Frame · crackedPDA 3 EXTERNAL POWER PANEL CUTOUT BOTTOM FRAME CRACKED& MISSING SECTION SEE PHOTO ACCOMPLISHED NDT (HFEC) INSP OF EXTERNAL POWER CUTOUT FOR SRM 53-10-15-2R-4 REPAIR 4 STEPS 4.C (7) AND D. 4. REF: 737 NDT PART 6 51-00-00 PROC 23. NO DEFECTS NOTED, OKAY TO CONTISDR 2022FA0000762Window Frame · corrodedDURING MAINTENENCE INSPECTION FOUND CORROSION ON CABIN WINDOW FRAME BETWEEN STA 977 AND STA 999 RH, BETWEEN STA 1153 AND STA 1175 LH, BETWEEN STA 1263 AND STA 1285 RH.SDR SWAA2023012680999Pressure Deck · crackedCRACK IN HORIZONTAL PRESSURE DECK BS 664.5 RBL 40.5 WL 206 CRACK IS .35 INCHES LONG. FOUND WITH HFEC INSPECTION. MARKED ENDS OF CRACK.<[01] UPDATED THE MEASUREMENT TABLE AND VERIFIED THE APPLICABILITY OF SRM 53-40-51-2R-2;[02] HORIZONTAL PRESSURE DECK BS 663 TSDR SWAA2023012680994Pressure Deck · crackedCRACK IN HORIZONTAL PRESSURE DECK BS 672 RBL 41.5 WL 206 CRACK IS .4 INCHES LONG. FOUND WITH HFEC INSPECTION. CUT AND REMOVED THE DAMAGED PART OF THE PRESSURE DECK IAW SRM 53-40-51-2R-2 REPAIR 2. HFEC INSPECTED ALL OPEN HOLES AND CUT EDGE IN THE REPAIR ARESDR SWIA2023011967126Beam · damagedF.S 409+128 BL 0.00 LH FWD VERTICAL BEAM DEFECT NOTED AT TOP FASTENER HOLE. REMOVED AND REPLACED VERTICAL BEAM IAW SRM 51-42-06, REV 39, SRM 51-42-22, REV 39, AND REO 601R-53-41-889 REV-C.SDR FDEA202212120247Floor Support · corrodedAFT CARGO COMPT STA 1844-1854 FLOORBOARD SUPPORT CORRODED. MRKD RBL60 REMOVED AND REPLACED FLOOR SUPPORT AGA3857-2 REF. DWG. AGA3857.SDR JR2R20221212423Crossbeam · corrodedCROSSBEAM FR17 CORRODED AT RBL11.SDR JR2R20221212282Doubler · corrodedFWD RH SILL DOUBLER CORRODED AT FWD SIDE AT FR17SDR JR2R20221212281Doubler · corrodedFWD RH FLOOR DOUBLER AT FR14 CORRODEDSDR FDEA202212110178Frame · crackedFORWARD AVIONICS COMPT: LEFT SIDE, APPROX STA 465 (UNDER RAM AIR DUCT FOR ACM #1) AT BOOT. A BOOT ATTACHMENT BOLT HAS CHAFED/WORN INTO THE FRAME. MARKED R & R BOLT PER SRM 51-31-01-OG,CHECK FOR DAMAGE ON FRAME, REPAIR AS NECESSARY.