JASC 5310
Service difficulty reports · 38,528
Reports filed under 5310 · Fuselage Main, Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5310' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5310' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2022110765910Filler · crackedEXTERNAL POWER DOOR CUTOUT AFT FLNGE IS CRACKED / [01] INSPECTED AREA; FOUND DAMAGE TO BE COMMON TO EXISTING REPAIR CUTOUT FILLER ONLY. REMOVED DAMAGE CUTOUT FILLER IAW SRM 53-10-15-2R-4;[02] VERIFIED MATERIAL FOR CUTOUT FILLER PN: 2024-T3-040 ATAG: A7976 IAW SDR CALA2022102802992Fairing · missingPDA 3 ON WALK AROUND FOUND RT BODY FAIRING PANEL 194CR MISSING FROM AIRCRAFT UPDATED WITH PICTURES INSTALLED NEW PANEL 194CR. RETURN TO SERVICE.SDR SWAA2022102765040Panel · crackedSUPPLEMENTAL INFORMATION: ELECTRICAL SERVICE PANEL PAST REPAIR AT LOWER CUTOUT AREA CRACKED / [01] REPAIRED ELECTRICAL SERVICE PANEL AT LOWER CUTOUT AREA IAW SRM 53-10-15-2R-4SDR DALA2022102806986Panel · corrodedCORROSION ON INBD FACE OF NLG LATERAL PANEL AROUND L/H BUSHING FOR NLG. COMPLIED WITH PRI 603249-14 REV 1.SDR KCSA202210271167Door Frame · corrodedEVIDENCE OF CORROSION AROUND FASTENER HOLES ON AFT CARGO DOOR FRAME APPROX 4 INCHES FROM AFT EDGE OF DOOR AND 26 INCHES FROM TOP EDGE OF DOORSDR R61A2022111500707Beam · corrodedFWD PAX DOOR (L1) LOWER BEAM CORRODED AT THE FWD AND AFT SLIDE FITTINGS. REMOVED AND REPLACED FWD PAX DOOR (L1) LOWER BEAM. REF SRM 51-40-08SDR R61A2022111000694Beam · corrodedFWD SERVICE DOOR (R1) LOWER BEAM CORRODED AT THE FWD AND AFT SLIDE FITTINGS. REMOVED & REPLACED LOWER BEAM AT FWD SERVICE DOOR PER REF SRM 51-40-08.SDR CALA2022102702960Flange · crackedSUPPORT TASK: FRAME 68 STR 22 RH FLANGE HAS CRACK ABOVE DOOR STO P BOLT #3 PER HAECO LCQ NON-ROUTINE 9294158/44158 GENERATED BY V 892444SDR EE4Y2022102616485Skin · dentedDURING THE ACCOMPLISHMENT OF THE INSPECTIONS AS PER ETD2016-190-052739 REV /, WAS FOUND THE DENT LOCATED AT FRAME 17 AND ABOVE STRINGER 22R WITH NICKS.SINCE THE DENT MENTIONED ABOVE IS DEEP AND IS LOCATED OVER-STRUCTURE, THE CUSTOMER PERFORMED DENT RECONTOUR (SDR ASAA2022102540833Shield · corrodedAFT CARGO PIT SHIELD FWD OF THE CARGO DOOR CORRODED. GROUNDED - YES. REMOVED AND REPLACED AFT CARGO PIT SHIELD FWD OF THE CARGO DOOR IAW B737-700 SRM 51-40-02-0G-0W-1" O-.050" R-.033" L-1" D-.017".SDR ASAA2022102540831Channel · corrodedAFT CARGO PIT LH TRANSITION FROM FS727 THRU FS807 CORRODED. GROUNDED - YES. REMOVED AND REPLACED AFT CARGO PIT L/H TRANSITION FROM FS727 THRU FS807 IAW B737-700 SRM 51-40-02-0G-0W=1 O=.040 R=.025 L=1 D=.015.SDR ASAA2022102540830Channel · corrodedAFT CARGO PIT RH TRANSITION AT FS727 THRU FS767 CORRODED. GROUNDED - YES. REMOVED AND REPLACED AFT CARGO PIT R/H TRANSITION IAW B737-700 SRM 51-40-02-0G-0W-2" O-.040" R-0 L-2" D-.040".SDR ASAA2022102540828Web · corrodedAFT PIT CARGO DOOR WEB SILL CORRODED. GROUNDED - YES. REMOVED AND REPLACED AFT PIT CARGO DOOR WEB SILL IAW B737-700 SRM 51-40-02-0G-0.SDR SWAA2022111764339Web · crackedINTERNAL HORZ. PRESSURE DECK STA 663 TO STA 675 - 2 CRACKS NOTED TO BE .5'. ONE AT BS 666 LBL 31; AND THE SECOND AT BS 673 LBL 35. / [01] CUT AND REMOVED THE DAMAGED PART OF THE WEB AT INTERNAL HORZ. PRESSURE DECK STA 663 TO STA 675 BETWEEN LBL 30 AND LBL 60 ISDR SIMA20221025003None · corrodedSSI 53-10-27 ? CORROSION ON RH OUTBD FLOOR SILL BETWEEN FR 17-20. (LEVEL 2 CORROSION)-C/A-RAR R/H OUTBOARD FLOOR SILL BETWEEN FRAMES 17-20 IAW EMB 175 SRM 51-40-08.SDR CALA2022102702954Support Channel · corroded(B757-53-3-0480) MAIN CABIN FLOOR STRUCTURE STA 346 RBL 62 GUTT ER SUPPORT CHANNEL CORRODED AT R1. TRANSCRIBED FROM HAECO GSO NRC# 9282302 REMOVED AND REPLACED SUPPORT P/N 141N5160-78 IAW BOEING DWG# 141 N5160 REV B AND B757-200 SRM 51-40-02. HAECO GSO MECHSDR FDEA202210252655Spar · crackedCENTER WING BOX - INSPECTION OF REAR SPAR AND BOTTOM PANEL AT JUNCTION WITH FUSELAGE FR47 RH SIDE, FASTENER "C" HOLE FOUND CRACK SIGNAL REPAIRED THE CENTER WING BOX REAR SPAR AND BOTTOM PANEL AT JUNCTION WITH FUSELAGE FR47 RH SIDE CRACKED FASTENER Ï¿½CÏ¿½ SDR KCSA202210251152Door Frame · corrodedEVIDENCE OF CORROSION AROUND FASTENER HOLE ON AFT CARGO DOOR FRAME APPROX 16 INCHES FROM AFT EDGE OF DOOR AND 26 INCHES FROM TOP EDGE OF DOORSDR KCSA202210251151Lap Joint · corrodedREF WO 100081853 CORROSION FOUND ON LAPSEAM AT STA 1279 LBL 27. TRANSFERRED FROM LOG BOOK 100081874.SDR SIMA20221024003None · corrodedSSI 53-10-027 ? CORROSION ON RH CENTER FLOOR BEAM AT FR 17 (FORWARD OF SEAT TRACK PROFILE) (LEVEL 2 CORROSION)-C/A-BLENDED AS REQUIRED TO REMOVE CORROSION FROM RH LOWER SEAT TRACK FWD END JUST AFT OF FR 17 IAW EMB 175 SRM 51-10-03. BLENDED AREA IS ACCEPTED AS SDR FDEA202210242651Intercostal · corrodedMAIN CABIN INTERCOSTAL IS CORRODED UPPER AND LOWER SIDE AT NUTPLATES HOLES BS 327 RBL 25 - RBL 39 REMOVED, FABRICATED AND REPLACED INTERCOSTAL IAW BAC DWG 141N5160 REV C. ORIG SUBMISSION DATE: 10/24/2022SDR FDEA202210242650Intercostal · corrodedMAIN CABIN INTERCOSTAL IS CORRODED UPPER AND LOWER SIDE AT NUTPLATES HOLES BS 327 RBL 4- RBL 23 REMOVED, FABRICATED AND REPLACED INTERCOSTAL IAW B757-2 DWG 141N5160. ORIG SUBMISSION DATE: 10/24/2022SDR FDEA202210242653Crease Beam · gougedDURING AGING AIRCRAFT INSPECTION, FOUND EXISTING CREASE BEAM WEB REPAIR WITH A GOUGE AT A FASTENER HOLE, STA 1397, RBL 69 REMOVED & REPLACED CREASE BEAM WEB IAW BAC DWG 146N5590, REV BSDR CALA2022102402926Fitting · crackedFLIGHT DECK WINDSHIELD CONTINUITY FITTINGS LH AND RH HAVE CRACK INDICATIONS "CONTACT ENGINEERING FOR REPAIR INSTRCUTIONS BEFORE NEXT FLIGHT" GENERATED AT HAECO LCQ PER NR 9294615 (44615) BY V8 92444 SUPPORT TASK ACCOMPLISHED A CATEGORY A PERMANENT REPAIR ON THSDR AALA202212200558Fitting · crackedAIRCRAFT IN BASE MAINTENANCE: FLIGHT DECK FRONT WINDSHIELD FRAME LEFT HAND CONTINUITY FITTING CRACKED BETWEEN FR 1 AND FR 2 AT Y0. MAINTENANCE REPLACED CONTINUITY FITTING PER EA 340118.SDR AALA202212200432Window Frame · crackedAIRCRAFT IN BASE MAINTENANCE: FLIGHT DECK FRONT WINDHIELD FRAME RIGHT HAND CENTER POST UPPER SPOT FACE CRACKED AT FR 4 AND Y0. MAINTENANCE REPAIRED WINDSHIELD FRAME PER EA 340118.SDR SIMA20221022004None · gougedCABIN LOWER RH SEAT TRACK IS GOUGED BETWEEN FR 80-81 (MAJOR REPAIR)-C/A- REMOVED DAMAGED SECTION OF RH LOWER FLOOR BEAM BETWEEN FR 80-85 AND FABRICATED AND INSTALLED REPLACEMENT SECTION AND SPLICE REPAIR PARTS IAW EMB-175 SRM 51-40-08 AND 53-00-10 REPAIR 01P FSDR SIMA20221022003Seat Track · corrodedSSI 53-23-005 ? CABIN LOWER LH SEAT TRACK IS CORRODED BETWEEN FR 84-85 (LEVEL 2 CORROSION)-C/A-BLENDED OUT DAMAGED AREA AND ADJACENT TEETH ON CABIN LH LOWER SEAT TRACK BETWEEN FR 84-85 IAW EMB 175 SRM 51-10-03 AND ERS-EJ-5300-4658SDR SIMA20221022002None · corrodedSSI 53-10-27 ? CORROSION ON RH FLOOR SILL BETWEEN FRS 12-15 (LEVEL 2 CORROSION)-C/A-RAR RH FWD FLOOR SILL BETWEEN FRS 12-15 IAW EMB-175 SRM 51-40-08.SDR SIMA20221022001None · corrodedSSI 53-10-027 ? CORROSION ON LH OUTBD FLOOR SILL BETWEEN FR 19-19A (LEVEL 2 CORROSION)-C/A-REMOVED CORROSION ON LH OUTBD FLOOR SILL BETWEEN FR 19-19A AS REQUIRED IAW EMB 175 SRM 51-10-03. BLENDED DAMAGE FOUND TO BE WITHIN LIMITS IAW EMB 175 SRM 51-75-16.SDR SIMA20221021009None · corrodedAFT GALLEY RH SHEAR PANEL CORRODED FRAME 87 (LEVEL 2 CORROSION)-C/A-RAR AFT GALLEY RH SHEER PANEL AT FR 87 IAW EMB-175 SRM 51-40-08SDR SIMA20221021008Upper Sheet · corrodedAFT GALLEY RH FLOOR BEAM UPPER SHEET CORRODED AT FR 85 (LEVEL 2 CORROSION)-C/A-RAR RH FLOOR BEAM UPPER SHEET BETWEEN FR 85-86 IAW EMB-175 SRM 51-40-08SDR SIMA20221021007None · noneFWD PAX DOOR SEAL DEPRESSOR HAS 3 CHAFED AREAS ALONG AFT EDGE (MAJOR REPAIR)-C/A-REMOVED CHAFED SECTION OF FWD PAX DOOR AFT SEAL DEPRESSOR AND INSTALLED SEAL DEPRESSOR FILLER SPLICE IAW EMB-175 SRM 53-10-25SDR SIMA20221021006Shear Panel · corrodedAFT GALLEY CENTER SHEAR PANEL CORRODED FR 87 (LEVEL 2 CORROSION)-C/A-RAR AFT GALLEY CENTER SHEAR PANEL FR 87 IAW EMB 175 SRM 51-42-01, SRM 51-43-03SDR SIMA20221021005None · corrodedAFT GALLEY LH SHEAR PANEL CORRODED FR 87. (LEVEL 2 CORROSION)-C/A-RAR AFT GALLEY LH SHEAR PANEL FR 87 IAW EMB 175 SRM 51-53-03, SRM 51-42-01SDR SIMA20221021004None · corrodedAFT GALLEY FLOOR SPLICE CORRODED ON FR 90 OUTBD OF RH BEAM. (LEVEL 2 CORROSION)-C/A-RAR AFT GALLEY RH FLOOR SPLICE ON FR 90 OUTBD OF RH BEAM IAW EMB 175 SRM 51-40-08.SDR KCSA202210211147Failsafe · corrodedCORROSION ON FAIL SAFE CHORD AT DRAIN HOLE @ BS 1562 BETWEEN STRINGERS S-39L AND S-39RSDR ASAA2022102040955Support Frame · corrodedFWD CARGO L/H FLOOR SUPPORT FRAME HAS CORROSION ON UPPER SKIN AND RIVET SHEARED FR31 TO FR34 GROUNDED - YES. REMOVED AND REPLACED FWD CARGO L/H OUTBD FLOOR SUPPORT FRAME AT FR31 TO FR34 Y=765 IAW A320 SRM 53-21-41-03-A REV 142 01 AUG 2022 AND SRM 51-42-11 REV SDR IPXA2022102187332Crossbeam · damagedINSPECTION TYPE:CCROSSBEAM AT FR49 BETWEEN -Y450 AND -Y953 BENT PN A5381337800000REMOVED AND REPLACED CROSSBEAM IAW SRM 5-40-21SDR IPXA2022102187331Crossbeam · crackedINSPECTION TYPE:CCROSSBEAM AT FR51 BETWEEN -Y450 AND -Y953 CRACKED P/N A5381337900040REMOVED AND REPLACED CROSSBEAM IAW SRM 51-40-21SDR ASAA2022102040873Floor Support · crackedFWD CARGO L/H OUTBD FLOOR SUPPORT FRAME IS CRACKED. GROUNDED - YES. REMOVED AND REPLACED FWD CARGO L/H OUTBD FLOOR SUPPORT BETWEEN FR28 - FR31 AND Y = 765 IAW A320-200 SRM REV. 142 DATE 01 AUG 2022 TASK 51-72-11-911-002 AND SRM 53-21-14-03-A ITEM 005.SDR SWAA2022111462431Crease Beam · corrodedCREASE BEAM WEB IS CORRODED AT BS 867+2-867+8; LBL 65; WL 208. BEGAN REMOVING CORROSION FROM CREASE BEAM WEB PER SRM 51-10-02. REMOVED CORROSION ON CREASE BEAM WEB IN SEVERAL AREAS. UT INSPECTED BLENDED AREA IAW NDTM PART 4 51-00-00 PROCEDURE 2. REPAIRED SDR UIEA2022100801103Intercostal · corroded***CORROSION*** AFT CARGO COMP, CORROSION ON FWD SIDE OF INTERCOSTAL STA 727+8, LBL5-RBL5, WL150. (CORROSION FOUND ON FWD SIDE OF INTERCOSTAL @STA 727+8, LBL 5 TO RBL 5, WL 150 TO BE 100% MATERIAL LOSS AND FOUND OUT OF LIMITS PER SRM 53-00-53-1A-2. REMOVED ANDSDR UIEA2022101401140Support · corroded***CORROSION***CORROSION FOUND ON FLOOR TO BULKHEAD SUPPORT IN FWD. CARGO BAY @STA. 400, RBL 24, WL 156(<P>REMOVED AND REPLACED FWD CARGO FWD LOWER BULKHEAD SUPPORT @STA. 400, RBL 24, WL 156 PER DWG# 284A0603 AND SRM 51-40-02-0G-0</P>)SDR DALA202210200001None · nonePAX DOOR FRAME CRACKED AT STA 280 STR3L LENTIL CLIP CORRECTIVE ACTION: REPAIRED PAX DOOR FRAME AT STA 280 STR 3L LENTIL CLIP IAW REO 670-53-21-493 REV D 2015-07-10 AND SB 6708A-53-40 REV C SEPT 20 2012SDR DALA20221020001Frame · cutSPLICE REPAIR AT FS 319 AT STR 27 IN FWD AVIONICS BAY. CORRECTIVE ACTION: PERFORMED REPAIR
TO FS 319 (PSDR DALA20221020003None · noneTHE FOLLOWING SOR V0XD20220202001 WAS SUBMITTED WITH THE INCORRECT OPERATOR DESIGNATOR REGION CODE VNAA GO 1S AND SHOULD BE VNAA GL 05SDR 2022FA0000636Angle · corrodedFLOOR BEM AT FS 333 JUST INSIDE SERVICES DOOR IS COORODED AT A FASTENER HOLE. CORRECTIVE ACTION: REPAIRED THE FLOOR BEAM BY FABRICATING AND INSTALLING A REPAIR STRAP IAW STS ENGINEERING AUTHORIZATION 20-2021-116.SDR REXA2022102402282Crossbeam · wornMAINTENANCE FOUND CHAFE DAMAGE TO THE AFT CARGO DOOR CROSS BEAM CAUSED BY A DETERIORATED FWD CARGO DOOR PULLEY WITH SUBSEQUENT CABLE CONTACT. DAMAGE MEASURES: L 0.52" W 0.066" DEPTH 0.057" FABRICATED REPAIR ANGLE AND COMPLETED INSTALLATION IAW EA CRJ253-14635SDR JJBA20221021014Mount Bracket · not reportedPERMANENT REPAIR TO PERFORM PER ETD 2020-145-003599 FOR FWD FUSELAGE LH UPPER LATERAL MOUNTING BRACKET. STRUCTURE REPAIRED WITH COLDWORKING OF 11 HOLES
Back to JASC 5310