SDR UPS07449143Plate · misrepairedINSPECTION TYPE:C M/D LEFT BS 800 TENSION TIE ATT STEEL PLATE FOUND SHORT EDGE MARGIN. M/D LEFT BS 800 TENSION TIE ATTACHED STEEL PLATE SHORT EDGE MARGIN REPAIRED AS PER RS R53-25-35710. CONTINUE INSPECTION IS REQUIRED AS PER RS R53-25-35710 AND UPS EO B747-SDR UPS07449142Plate · misrepairedINSPECTION TYPE:C M/D RIGHT BS 800 TENSION TIE ATT STEEL PLATE FOUND SHORT EDGE MARGIN. M/D RIGHT BS 800 TENSION TIE ATTACH STEEL PLATE SHORT EDGE MARGIN REPAIRED AS PER RS R53-25-35710. CONTINUE INSPECTION IS REQUIRED AS PER RS R53-25-35710 AND UPS EO B747-SDR UPS07449141Tension Tie · crackedINSPECTION TYPE:C M/D RIGHT BS 780 TENSION TIE TO FRAME CONNECTION FOUND 1EA HOLE CRACK AT TENSION TIE CHANNEL RUNNING UP AND DOWN APPROX .0625 INCH CRACK LENGTH .125 INCH. M/D RIGHT BS 780 TENSION TIE FWD CHANNEL REPAIRED AS PER RS R53-25-35713, CONTINUE INSSDR UPS07449140Plate · misrepairedINSPECTION TYPE:C M/D RIGHT BS 920 TENSION TIE ATT STEEL PLATE FOUND SHORT EDGE MARGIN. M/D RIGHT BS 920 TENSION TIE ATTACH STEEL PLATE SHORT EDGE MARGIN REPAIRED AS PER RS R53-25-35716. CONTINUE INSPECTION IS REQUIRED AS PER RS R53-25-35716 AND UPS EO B747-SDR CALA0700003Door Frame · crackedINSPECTION FOUND FORWARD CARGO DOOR CUTOUT FORWARD FRAME WEB CRACKED AT DOOR STOP FITTING FWD/LWR AREA, STA 400, S24R, WL 160. THE FRAME WAS REMOVED AND A NEW FRAME WAS INSTALLED IAW SRM 51-40-02.SDR UPS07449148Tension Tie · crackedINSPECTION TYPE:C M/D BS 920 STR 8-9L TENSION TIE LEFT O/B AFT CHANNEL FOUND CRACK. CRACK LENGTH .125 INCH. M/D BS 920 STR 8-9L TENSION TIE LEFT O/B AFT CHANNEL REPAIRED AS PER RS R53-25-35716. CONTINUE INSPECTION IS REQUIRED AS PER RS R53-25-35716 AND UPS SDR UPS07449133Tension Tie · crackedINSPECTION TYPE:C M/D RIGHT BS 840 TENSION TIE TO FRAME CONNECTION FOUND 1EA HOLE CRACK AT TENSION TIE FWD CHANNEL (CRACK LENGTH 0.060"). M/D LEFT TO RIGHT TENSION TIE FWD CHANNEL REPLACED AND INSTALLED AS PER SRM 51-10-01 PG 9 & SRM 51-30-02 & UPS EO B747-53SDR UPS07449131Tension Tie · crackedINSPECTION TYPE:C M/D LEFT BS 840 TENSION TIE TO FRAME CONNECTION FOUND 1EA HOLE CRACK AT FWD CHANNEL APPROX 0.060" RUNNING UP. M/D LEFT TO RIGHT TENSION TIE FWD CHANNEL REPLACED AND INSTALLED AS PER SRM 51-10-01 PG 9 & SRM 51-30-02 & UPS EO B747-5310-23715 ASDR UPS07449125Tension Tie · crackedINSPECTION TYPE:C M/D- RIGHT BS 840 TENSION TIE TO FRAME CONNECTION FOUND 1EA HOLE CRACK AT TIE CLIP APPROX 0.040 INCH RUNNING UP. M/D RIGHT BS 840 TENSION TIE TO FRAME CONNECTION TIE CLIP REPLACED & INSTALLED AS PER SRM 51-10-01 PG 9 & 51-30-02.SDR UPS07849075Window Frame · corrodedINSPECTION TYPE:C2 RIGHT & LEFT WINDOW FRAME Z-ANGLES (CENTER WINDSHIELD) ARE CORRODED AND PITTED. REPAIRED CENTER WINDSHIELD Z-ANGLE IAW SAA EA 008-5310-01-A0570 UPS EO DC8-5310-25945-A, BAC MSG 1-269510850, AND FAA FORM 8100-9.SDR USAA07003Door Frame · gougedAFT CARGO DOOR FWD FRAME BS 797 GOUGED. REPAIRED IAW EA 98374, DEFECT SIZE: .010 INCH.SDR SWIA200717835Buttstrap · corrodedFOUND CORROSION AT RIGHT AND CENTER BUTTSTRAPS NEAR LAV AREA, DISCOVERED DURING C-CHECK INSPECTION. REPLACED RIGHT AND CENTER BUTTSTRAPS NEAR LAV AREA IAW SRM 120 51-10-02 PG 3 SEC 3A.SDR SWIA200717834Buttstrap · corrodedFOUND CORROSION AT CARGO DOOR ENTRANCE BUTTSTRAP, DISCOVERED DURING C-CHECK INSPECTION. REPLACED BUTTSTRAP AT CARGO DOOR ENTRANCE IAW SRM 120 51-10-02 PG 3 SEC 3A.SDR SWIA200717833Buttstrap · corrodedFOUND CORROSION AT PASSENGER DOOR ENTRANCE BUTTSTRAP, DISCOVERED DURING C-CHECK INSPECTION. REPLACED BUTTSTRAP AT PASSENGER DOOR ENTRANCE IAW SRM 51-10-02 PG 3 SEC 3A.SDR CALA0600548Door Frame · crackedINSPECTION FOUND A 1.5 INCH CRACK AT LOWER STOP PAD BRACKET OF FORWARD CARGO DOOR CUTOUT AFT FRAME, STA 493. THE FRAME WAS REPLACED IAW SRM 51-40-02 AND BOEING DRAWING 65-20723.SDR UPS07848865Door Frame · crackedINSPECTION TYPE:C2 HFEC INSP DETECTED A .156" CRACK ON THE UPPER FWD CORNER OF THE B-PIT DOOR JAMB. CUT OUT DAMGED AREA AT THE UPPER FWD B-PIT DOOR JAMB IAW SRM 53-2-0 FIG 20. FABRICATED AND INSTALLED FILLERS, DOUBLER AND TRIPLER AT THE UPPER FWD B-PIT DOOR SDR 06FDEA04375Door Frame · crackedLT AFT SERVICE DOOR FWD FRAME IS CRACKED AT CUTOUT FOR GUIDE ARM, AT INBD LOWER CORNER. INSTALLED REPAIR DOUBLER REF EA NR I060464, FED EX EA NR 7-5210-105271. CLASSIFIED AS A MAJOR REPAIR.SDR DLM88070421Door Frame · corrodedFWD CARGO DOOR JAMB REPAIR - CORROSION ON DOOR JAMB(LOWER SIDE) OF FWD CARGO COMPARTMENT BETWEEN STA 370-427. PERMANENT REPAIR INSTALLED PER SRM 53-05D, FIG 804D.SDR SWAA065111Door Frame · crackedDURING SCHEDULED SPV CHECK, FOUND AFT CARGO DOOR CUTOUT FWD FRAME CRACKED AT NR 5 DOOR STOP. REMOVED AND REPLACED FRAME SECTION PER SRM.SDR DLM88070422Door Frame · corrodedREPAIR TO MID CARGO DOOR JAMB CORROSION - PERMANENT REPAIR INSTALLED PER SRM 53-05D, FIG 63.SDR QXEA200603370Door Frame · chafedOKC - FORWARD CARGO DOOR FORWARD LOWER CORNER CHAFED ON UPPER FRAME. REPAIRED IAW CRJ 700 SRM 51-12-00, 51-21-11 AND 51-25-16.SDR 06FDEA04358Crossbeam · crackedDURING ACCESS OPENING ON MAIN CARGO DECK CROSSBEAM FS 44,Y1456/Y1956, P/N R538D1048-200-00, WAS FOUND CRACK AND NEED TO BE REPLACED TRACK REPLACED PER SRM 51-40-00. REPAIR EVALUATED PER GMM 6-2-100 AND CLASSIFIED AS "MAJOR".SDR 06FDEA04356Crossbeam · crackedDURING ACCESS OPENING ON MAIN CARGO DECK CROSS TRACK FR 50,-Y450/-Y953, P/N A53812934-200-00, WAS FOUND CRACKED AND NEEDED TO BE REPLACED. TRACK REPLACED PER SRM 51-40-00.SDR 2006UALA02408Door Frame · crackedCRACK WAS FOUND COMMON TO THE FWD FRAME OF THE FWD CARGO DOOR CUTOUT AND THE AFT FRAME OF AFT CARGO DOOR CUTOUT. MAJOR REPAIR: REMOVED DAMAGE. ACCOMPLISHED ANGLE REPAIR PER AAR EAI060551 AND I060553 REV IR AND UA EVA 60762.SDR TRAX200601137Beam · crackedBOX BEAM CRACKED AT UPPER CENTER LOCATION. PERFORMED EDDY CURRENT INSPECTION OF UPPER BOX BEAM JUST FWD OF FIRE LOOP STAND OFF CLIP PER MTC REQUEST IAW CRJ 200 NDTM PART 1. 51-20-06. BOX BEAM IS CRACKED AT UPPER CENTER LOCATION. REMOVED UPPER FIRE BOTTLSDR USAA061444Crease Beam · corrodedRIGHT CREASE BEAM AT BS 235.8 CORRODED. CUT OUT AND REMOVED CORROSION IAW EA 98283 LEVEL 2 C53-101-01, DEFECT SIZE: .50 X 4 INCHES.SDR AWXA200700006Crease Beam · corrodedMCN - CORROSION ON CREASE BEAM INNER CHORD, BS 967 - BS 987, LBL 54 - LBL 55, WL 208. REPLACED CREASE BEAM INNER CHORD, BS 967 - BS 987, LBL 54 - LBL 55, WL 208 I/A/W B737-300 SRM 541-40-02.SDR GUUA12150603Skin · ground damageFLIGHT: 9214, DURING GROUND HANDLING BAGGAGE CART DAMAGE BELOW CARGO DOOR LOCATED AT F.S 482.75 TO F.S 500. CUT OUT DAMAGE SECTION OF SKIN 17.0 IN X 7.0 IN FABRICATED AND INSTALLED EXTERNAL REPAIR DOUBLER 20.0 IN X 10.0 IN IAW STRUCTURAL REPAIR MANUAL 51-70-SDR USAA061434Crease Beam · corrodedBETWEEN STA 324-327 RBL 60 CORRODED. REMOVED & REPLACED 2 CREASE BEAMS PER SRM 51-40-02; CORR TASK JL-46-53500, LEVEL 1, DEFECT SIZE: 120 SQ INCHES.SDR USAA061429Door Frame · crackedBS 492 FRAME AT LOWEST DOOR STOP CRACKED. REMOVED DAMAGE, FABRICATED AND INSTALLED FILLER AND REPAIR ANGLES IAW EA 98327, DEFECT SIZE: .125 INCH.SDR USAA061424Crease Beam · corrodedRIGHT CREASE BEAM BETWEEN CHORD & WEB AT STA 1636 CORRODED. REMOVED & REPLACED WEB PER SRM 51-40-02. CORR TASK JA-58-53516, LEVEL 1, DEFECT SIZE: 1 X 3 INCHES.SDR AWXA200700088Door Frame · crackedMCN - MAJOR REPAIR - FORWARD GALLEY DOOR, AFT FRAME CRACKED AT 4TH STOP FITTING FROM THE TOP. REPAIRED FORWARD GALLEY DOOR, AFT FRAME AT 4TH STOP FITTING FROM THE TOP IAW AWA ER 03-5300-06354-HF2.SDR TRAX200601117Beam · corrodedFS 280 BEAM CORRODED. REPAIRED IAW REO 670-53-11-047.SDR K11A2008122272301Beam · corrodedI-BEAM ON TOP OF NOSE W/W CORRODED.SDR SWIA200617678Door Frame · crackedCRACK IN PAX DOOR FRAME BELOW AFT STEP SUPPORT, DISCOVERED DURING C-CHECK INSPECTION. NEW FRAME INSTALLED IAW SRM 120 51-10-02, PG 3, SEC 3.A AND RII CARD 52-800-1000.SDR 2006UALA02367Door Frame · crackedFORWARD CARGO DOOR CUTOUT AFT FRAME CRACKED IN THREE LOCATIONS NEAR AT LWR DOOR STOP FITTING NEAR STR S-24R. MAJOR REPAIR: REMOVED DAMAGE. FABRICATED AND INSTALLED EXTERNAL NESTED ANGLE REPAIR PER AAR EA I060540 AND UAL EVA 60751.SDR 06FDEA04218Crossbeam · damagedFUSELAGE MAIN FRAME CROSSBEAM EXTRANEOUS HOLE REPAIR FS 67;-Y2017. COMPLIED WITH EA 6-5310-101996 FUSELAGE MAIN FRAME CROSSBEAM EXTRANEOUS HOLE REPAIR FR 67 Y-2017.SDR AWXA200602068Rail · corrodedSAL - CORROSION ON MAIN CABIN DUMMY RAIL, FS 16, +Y503.2. REPLACED MAIN CABIN DUMMY RAIL, FS 12 - FS 16, +Y503.2 IAW A320 SRM 51-72-11.SDR TRAX200601104Doubler · unknownLEFT FS 640 DOUBLER SUSPECT CRACKED, REF EO600-53-69 0002.SDR SWAA064879Door Frame · corrodedDURING SCHEDULED 22Y CHECK, FOUND R2 DOOR CUTOUT AFT FRAME CORRODED AT BS 993, STR 17R. REPAIRED FRAME SECTION PER SRM.SDR AWXA200700017Door Frame · corrodedMCN - CORROSION ON R2 DOOR CUTOUT INNER CHORD AT BS 917 - BS 1006, WL 208, RBL 45 - RBL55. REPLACED R2 DOOR CUTOUT INNER CHORD AT BS 917 - BS 1006, WL 208, RBL 45 - RBL55 IAW B737 SRM 51-40-02-0G, FIG 3, 8, 12.SDR AMTA200600713Panel · corrodedFS 400-449 LBL 22 RBL 22 NR 1 PANEL 120AF CORROSION EXISTS ON ITS FORWARD AND OUTBOARD EDGES OF THE PANEL. OUT OF LIMITS. FABRICATED REPLACEMENT PANEL NR 120 AF ON FAB TRAVELER 7520622. (M)SDR A6WA200640410Post · crackedFOUND BULKHEAD POST AT FS 409 PLUS 128, RBL 18 LOWER OUTBOARD RIVET HOLE IS CRACKED APPROXIMATELY .25 INCH LONG. MAINTENANCE TRIMMED OUT CRACKED PORTION OF STIFFENER AND REPAIRED WITH A REPAIRED WITH A REPAIR ANGLE IAW BOMBARDIER AEROSPACE REO-601-53-41-056. SDR QXEA200603313Door Frame · damagedC3 - EXTERNAL GALLEY SERVICE DOOR SURROUND, STATION FS 319.00, TOP 3 STOP FITTINGS HAVE WEAR MARKS FROM THE DOOR. REPAIRED IAW REO 670-53-21-238.SDR 2006UALA02344Door Frame · damagedFWD CARGO DOOR CUTOUT AFT FRAME IS CRACKED IN THREE PLACES AROUND LOWER BOTTOM DOOR STOP. CRACKS ARE AT OB LOWER CORNER AND TWO CRACKS AT INBD UPPER CORNER. ALSO, AFT CARGO DOORWAY FWD FRAME STA 794.3 RBL 19 TO RBL 21 CORRODED. REMOVED DAMAGE. INSTALLED REPASDR AWXA200700018Door Frame · crackedMCN - CRACK ON R1 DOOR CUTOUT FORWARD UPPER FRAME AT BS 300, S10R. CRACK ON R1 DOOR CUTOUT FORWARD UPPER FRAME AT BS 300, S10R IAW B737 SRM 51-40-02-0G, FIG 3, 8.SDR 06FDEA04192Crossbeam · crackedFUSELAGE-MAIN FRAME-CROSS BEAM CRACK REPAIR FRAME 59;Y1600. COMPLIED WITH EA# 6-5310-101995, STEP 1-3 FUSELAGE-MAIN FRAME CROSSBEAM CRACK REPAIR FRAME 59;Y1600. COMPLIED WITH EA NR 6-5310-101995, STEP 1-3, FUSELAGE-MAIN FRAME CROSSBEAM CRACK REPAIR FRAME 59;SDR CA061207002Window Frame · corroded(CAN) REMOVED FRONT WINDSHIELDS TO COMPLY WITH COCKPIT WINDOW FRAME INSPECTION REQUIREMENT OF THE C2 INSPECTION. FOLLOWING REMOVAL OF PILOT’S WINDSHIELD, SEVERE EXFOLIATION CORROSION WAS FOUND ON LOWER FRAME APPROX. 16 INCHES FROM OUTER RAIL OVER AN 8 INCH WISDR 06FDEA04180Door Frame · crackedMAIN CABIN, CRACK LONG 0.50" ON WEB AFT JAMB DOOR NR 3 LT STA 1305 LONG NR 27. REMOVED FLOOR COVER IAW MM 20-50-02. MAKE STOP DRILL CRACK DIAM .250". PERFORMED MFC INSP NOT FOUND ANOTHER CRACK, IAW NDI SPM 06. INSTALLED REPAIR DOUBLER IAW SRM 53-50-00 FIG SDR USAA061398Crease Beam · corrodedRIGHT CREASE BEAM AT BS 235.8 CORRODED. CUTOUT AND REMOVED CORRODED AREA IAW EA 98283 LEVEL 1 C53-101-01, DEFECT SIZE: .50 X 4 INCHES.
Back to JASC 5310