JASC 5310
Service difficulty reports · 38,573
Reports filed under 5310 · Fuselage Main, Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5310' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5310' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA20021855Shear Tie · crackedTUL - FOUND CRACK FS 1437. REPLACED SHEAR TIE PER SRM 53-05-00. (M)SDR 2002UALA01858Door Frame · damagedDURING HMV3 THE BS794 AFT CARGO DOOR SURROUND FRAME BETWEEN STR 23R AND 24R, FOUND WITH ELONGATED HOLE. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED REPAIR ANGLE AND DOUBLER.SDR 02FDEA00950Shear Tie · corrodedCORROSION ON AFT BAY SHEAR TIE AT BS 1010, LBL 9, WL 138.SDR 02FDEA00952Stringer · crackedFOUND CRACK IN STR 21 LT AT BS 540.SDR SIMA200300808Beam · corrodedABI - THIS IS A LEVEL 2 FINDING, FOUND DURING AN IMBV INSPECTION, CENTER BEAM RAMP FOUND CORRODED. REMOVED AND INSTALLED SERVICEABLE RAMP IAW EMB 145 SRM 51-40-02, 51-20-03. (M)SDR SIMA200235107Beam · corrodedABI - DUIRNG AN IMBV INSPECTION, THE GALLEY FLOOR CENTER BEAM WAS FOUND TO BE CORRODED BELOW SRM LIMITS AT FRAME 23. BLENDED THE CORRODED AREA AND PERFORMED NDT INSPECTION APPLIED ALODINE AND EPOXY PRIMER TO THE BLENDED AREA. FILLED THE BLENDED AREA WITH EPOSDR SROM200200023Stanchion · crackedDURING C CHECK INSPECTION FOUND FWD CARGO BAY STANCHON CRACKED. REPLACED STANCHON PER SRM 51-30-2. 51-10-3, MINOR REPAIR.SDR DL757021442Door Frame · corrodedCORROSION REPAIR, THE OUTER CHORD OF THE C1 DOOR CUTOUT LOWER SILL BEAM WAS FOUND CORRODED AND REQUIRED REPLACEMENT. TO FACILITATE THE REPLACEMENT, THE FS 620 FRAME WEB AND OUTER CHORD WERE CUT BETWEEN STRINGERS 25R-26R AND THE LOWER PORTIONS REMOVED. THE SISDR SWIA200211720Frame · crackedFS 718 RHS FRAME CRACKED BETWEEN STR 10-12. FOUND DURING C CHECK INSPECTION. DAMAGED AREA REPAIRED IAW CRJ REO 601R-53-61-193 REV ''A'' . HFEC INSPECTION COMPLIED WITH ON FRAME CUTOUT REPAIR AND AREA AS REQUESTED IAW RJ NDTM 51-20-06. NO CRACKS FOUND.SDR ASAA0210388Door Frame · corrodedPAE - DURING SCHEDULED C-CHECK, FOUND AFT CARGO DOOR FRAME AT BS 790-794, STRINGER 23R-26R CORRODED. REMOVED CORROSION AND REPAIRED CARGO DOOR FRAME PER SRM. (M)SDR C2XA02TY172Sill · corrodedDURING A SCHEDULED INSPECTION THE LT HAND SERVICE DOOR SILL PLATE WAS FOUND TO BE CORRODED. MAINTENANCE ACCOMPLISHED A BLEND OUT REPAIR IAW EMB GST 1927/02A, EMB-145 CPM 51-21-04,05 & 06, THE REPAIR WAS SATISFACTORY. THE AIRCRAFT WILL BE RELEASED UPON COMPLESDR C2XA02TY171Sill · corrodedDURING A SCHEDULED INSPECTION THE RIGHT HAND SERVICE DOOR SILL PLATE WAS FOUND TO BE CORRODED. MAINTENANCE ACCOMPLISHED A BLEND OUT REPAIR IAW EMB GST 1927/02A, EMB-145 SRM 51-40-02, CPM 51-21-04, THE REPAIR WAS SATISFACTORY. THE AIRCRAFT WILL BE RELEASED UPSDR 2002UALA01849Sill · damagedLT ENTRY DOOR WAY CUT OUT UPPER SILL HAS 4 HOLES DRILLED INTO IT. MAJOR REPAIR ACCOMPLISHED. REPAIR STRAP.SDR 0204049915Bulkhead · crackedDuring an Hck in ATL and while accomplishing an inspection, a crack was found in the aft pressure bulkhead doorjamblower sill channel. The crack is in the upper flange of the channel and extends approximately .75" through a screw hole. Repaired per EA 99-19086SDR 2002UALA01837Crease Beam · corrodedCABIN CREASE BEAM HAS CORROSION AT STATION 324 RBL 62. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. REPLACED INBOARD CREASE BEAM CHORD.SDR 02FDEA00934Crease Beam · corrodedN00836 CORROSION C53-224-02 CREASE BEAM BS 500 RBL 67. CORROSION ON CREASE BEAM AT BS 600, RBL 67, WL208 FOUND TO BE OUT OF LIMITS IAW SRM 53-10-1. REMOVED CREASE BEAM BS 445-525, RBL 67,WL 208. FABRICATED REPLACEMENT CREASE BEAM FROM BAC 1515-531 7075-T6 LOSDR DL757021423Door Frame · corrodedCORROSION REPAIR, THE INNER CHORD OF THE FS 729 FRAME OF THE L2 DOOR OPENING WAS FOUND WITH CORROSION ON THE INBD FLANGE AT WL 212. THE CORROSION WAS REMOVED WITH A TRIMOUT TO THE FLANGE. THE TRIMOUT WAS REPAIRED WITH A REPAIR ANGLE PER THE B757 SRM AND ER/ASDR QXEA0202137Stop Fitting · chafedPDX - UPPER AFT CARGO DOOR STOP CASTING CHAFED WHERE STOP CONTACTS FACE, NR 8 STOP. REPAIRED IAW DHC-8 SRM 51-20-16.SDR QXEA0202136Stop Fitting · chafedPDX - LOWER FORWARD DOOR STOP CASTING CHAFED WHERE STOP CONTACTS FACE, NR 9 STOP. REPAIRED IAW DHC-8 SRM 51-20-16.SDR QXEA0202135Stop Fitting · chafedPDX - FORWARD UPPER DOOR STOP CASTING CHAFED WHERE STOP CONTACTS FACE, NR 2 STOP. REPAIRED IAW RD 8-53-104.SDR C2XA02SH138Beam · corrodedDURING C CHECK, THE LT HAND OMEGA BEAM AT FRAME 20 INBOARD SIDE WAS FOUND TO HAVE CORROSION. MAITENACE REMOVED DAMAGED AREA AND PERFORMED A SPLICE REPAIR IAW EMB 145 SRM 53-21-10. THE AIRCRAFT WAS APPROVED TO RETURN TO SERVICE.SDR ASAA0210357Beam · corrodedPAE - DURING SCHEDULED C-CHECK, FOUND CREASE BEAM SUPPORT ANGLE AT BODY STATION 207, RIGHT BUTTOCK LINE 60 CORRODED. REMOVED AND REPLACED CREASE BEAM SUPPORT ANGLE PER SRM. (M)SDR SIMA200234506Sill · corrodedDURING AN IMBV INSPECTION THE CARGO DOOR CENTER SILL WAS FOUND TO BE CORRODED BELOW SRM LIMITS. REMOVED DAMAGED CENTER SILL AND REPLACED WITH SERVICEABLE SILL. REPAIR DONE IAW SRM.SDR SIMA200234502Sill · corrodedDURING AN IMBV INSPECTION THE SERVICE DOOR CENTER SILL WAS FOUND CORRODED BELOW SRM LIMITS. REMOVED EXISTING CENTER SILL AND INSTALLED SERVICEABLE SILL IAW EMB GST.SDR C2XA02SH135Floor Support · corrodedDURING C CHECK, THE CENTER OMEGA BEAM BUTT STRAP WAS FOUND TO HAVE CORROSION BETWEEN FRAMES 20 AND 23. MAINTENANCE REMOVED DAMAGE AND REPLACED AFFECTED BUTTSTRAP IAW EMB 145 SRM 51-40-02. THE AIRCRAFT WAS APPROVED TO RETURN TO SERVICE.SDR AALA20021740Shear Tie · crackedTUL - FOUND SHEAR TIE CRACKED STATION 1437, RIGHT SIDE OF LONGERON 1R AFT SIDE. REMOVED AND REPLACED SHEAR TIE PER SRM 51-30. (M)SDR AALA20021739Shear Tie · crackedTUL - FOUND SHEAR TIE CRACKED AT FASTENER HOLE, RIGHT SIDE OF L2R. REPLACED WITH SERVICEABLE SHEAR TIE PER SRM 51-30. (M)SDR BMAC020025Doubler · crackedFOUND 5.5 INCH LONG CRACK IN PREVIOUS REPAIR DOUBLER AT MAIN CABIN DOOR FORWARD HINGE POINT ADJACENT TO THE TOP OF THE HINGE. FABRICATED AND INSTALLED NEW REPAIR IAW BAE J31 SRM CHAPTER 52-10-11, PAGES 24, 26A, AND 26B REPAIR 1379837R, REF FIGURE 7A. NO CHANSDR 2002UALA01808Crease Beam · corrodedSTATION 294 THROUGH 398 AT STRINGER 17R, FLOOR CREASE BEAM CORRODED. MAJOR REPAIR ACCOMPLISHED. NEW CREASE BEAM INSTALLED.SDR 2002UALA01805Crease Beam · corrodedAFT GALLEY DOOR LOWER SILL CREASE BEAM INNER CHORD HAS CORROSION STATION 947-986, STRINGER 17R, WL 208. MAJOR REPAIR ACCOMPLISHED. REPLACED CREASE BEAM INNER CHORD.SDR UPS02239973Web · crackedINSPECTION TYPE:C SUSPECT CRACKS IN NOSE WHEEL WELL R/H WEB, JUST BELOW FWD END OF AFT PRESSURE PANEL REPAIR CARRIED OUT IAW SRM 51-40-2 & 51-30-2. REPAIR PARTS LEAK CEHC KED OK IAW MM 5-51-25SDR QXEA0202095Door Frame · chafedPDX - CARGO DOOR APERTURE UPPER FRAME IS CHAFED AT FORWARD AND AFT DOOR STOPS. REPAIRED IAW RD8-53-5461.SDR AALA20021770Door Frame · corrodedTUL - FOUND CORROSION ON VERTICAL AND HORIZONTAL LEGS OF DOOR BEAM. REMOVED AND REPLACED DOOR BEAM AARD 53-10-00-3. (M)SDR GAIA02161STStructure · dentedDURING MAINTENANCE, DAMAGE WAS DISCOVERED AT BS 540 BETWEEN S18L AND S19L. REPAIR WAS ACCOMPLISHED IAW FLIGHT VEHICLES CONSULTING INC DRAWING 53-02679-1. AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR 2002UALA01786Crease Beam · corrodedLEFT HAND CREASE BEAM WEB IS CORRODED FROM BODY STATION 787 TO BODY STATION 807. MAJOR REPAIR ACCOMPLISHED. REPLACED CREASE BEAM.SDR QXEA0202046Door Frame · crackedPDX- CRACK IN FRAME FORWARD SIDE OF AFT EQUIPMENT BAY DOOR OPENING ABOVE LEFT HAND DOOR HINGE AT STATION 1108.00. REPAIRED IAW HORIZON AIR EA R-53-62.SDR AALA20021767Door Frame · corrodedTUL - FOUND CORROSION ON VERTICAL AND HORIZONTAL LEGS OF DOOR BEAM. REMOVED AND REPLACED AFT CARGO DOOR BEAM AARD 53-10-00-3. (M)SDR ASAA0280612Door Frame · wornOAK - FOUND C-CHECK, FORWARD ACCESSORY COMPARTMENT DOOR JAMB FOUND WORN IN SEVERAL AREAS AROUND CIRCUMFERENCE. INSTALLED DOUBLER ON DOOR JAMB PER SRM 53-01 AND 53-10-3. (M)SDR SWIA200211613Sill · crackedCARGO DOOR FLOOR SILL FS 575.5 CRACKED. FOUND DURING C-CHECK INSPECTION. REPAIRED DAMAGED AREA IAW CRJ REO 601R-53-61-620 'NC'. NDT-HFEC CARRIED OUT IAW REO 601R-53-61-620. NO CRACKS NOTED.SDR 02FDEA00891Shear Tie · corrodedCORROSION FWD CARGO BAY ON SHEAR TIE BS 720E BETWEEN STR 28 LT & 28 RT. REPAIRED SHEAR TIE IAW SRM 53-10-4 FIG 15 AND EA 7-5310-68106.SDR UPS02239955Fitting · crackedINSPECTION TYPE:C L/H LWR TENSION TIE FITTING CRACKED AT O/B LUG IN TAILSKID COMPARTME NT INSTALLED NEW L/H LWR TENSION TIE FITTING IAW SRM 51-30-02 & DRAWING 65-25992SDR 02FDEA00889Shear Tie · corrodedCORROSION ON SHEAR TIE B/S 720 BETWEEN STR 25L & 24L.SDR GTIA021315Beam · corrodedFTW - FOUND AFT PIT JAM BEAM CORRODED, INSIDE AND OUT. REMOVED LOWER JAMB BEAM. INSTALLED NEW LOWER JAMB BEAM. (M)SDR GTIA021306Beam · corrodedMID CARGO DOOR, BOTTOM FORWARD AND AFT DOOR STOPS HAVE CORRODED UNDERNEATH. MID CARGO DOOR JAM BEAM HAS CORROSION ON THE REPAIR STRAP INSIDE OF BEAM. REMOVED JAMB BEAM. LOCATED AND DRILLED NEW JAMB BEAM. INSTALLED DOOR JAMB BEAM.SDR UPS02239943Pressure Panel · crackedINSPECTION TYPE:C SEVERAL CRACKS ON NLG WHEEL WELL PRESSURE WEB RHS FROM BS 260 DOWN 1 1" FROM CEILING AND 1" FWD OF THE AFT PRESSURE PANEL TP BS 279 6" BE LOW AFT PRESSURE PANEL DAMAGED AREAS REPAIRED IAW SRM51-40-2 FIG 1SDR AWXA200201218Door Frame · crackedDURING C-09 CHECK A .6250 INCH CRACK WAS FOUND ON FORWARD CARGO DOOR CUTOUT FRAME WEB AT ATTACHMENT HOLE FOR UPPER GUIDE TRACK FITTING, BS 560. MAINTENANCE REMOVED THE CRACKED SECTION OF FORWARD CARGO DOOR FRAME WEB BS 560; FABRICATED A REPAIR PLATE AND SPLICESDR AWXA200201217Door Frame · crackedDURING C-09 CHECK A .250 INCH CRACK WAS FOUND ON FORWARD CARGO DOOR CUTOUT FORWARD FRAME WEB AT ATTACHMENT HOLE FOR NR6 DOOR STOP, BS 560. MAINTENANCE REMOVED THE CRACKED SECTION OF FORWARD CARGO DOOR FRAME WEB BS 560; FABRICATED A REPAIR PLATE AND SPLICE PLATSDR AWXA200201216Door Frame · crackedDURING C-09 CHECK 2 EACH .3750 INCH CRACKS WERE FOUND ON AFT CARGO DOOR CUTOUT FRAME WEB AT THE LOWER DOOR STOP FITTING HOLE, BS 1440. MAINTENANCE REMOVED THE CRACKED SECTION OF AFT CARGO DOOR FRAME WEB BS 1440; FABRICATED A REPAIR PLATE AND SPLICE PLATE; AND SDR AWXA200201215Door Frame · crackedDURING C-09 CHECK A .250 INCH CRACK WAS FOUND ON AFT CARGO DOOR SURROUND CUTOUT WEB AT THE LOWER DOOR STOP FITTING HOLE, BS 1380. MAINTENANCE REMOVED THE CRACKED SECTION OF AFT CARGO DOOR FORWARD FRAME WEB; FABRICATED A NEW SECTION OF FRAME WEB; AND INSTALLED SDR UPS02239962Fitting · crackedINSPECTION TYPE:C TAILSKID BAY R/H UPPER TENSION TIE AFT FITTING CRACKED NEW R/H UPPER TENSION TIE AFT FITTING INSTALLED IAW SRM 51-30-02 AND DRAWING 65-25992
Back to JASC 5310