JASC 5310
Service difficulty reports · 38,573
Reports filed under 5310 · Fuselage Main, Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5310' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5310' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ABXA010300Shear Tie · corrodedAFT CARGO AT STATION 1140 BETWEEN LONGERON 34 RIGHT AND 35 RIGHT, SHEAR TIE AND FRAME CORRODED.SDR ABXA010299Shear Tie · crackedAFT CARGO AT STATION 1120 BETWEEN LONGERON 35 LEFT AND 36 LEFT, SHEAR TIE CRACKED.SDR USAA010609Shear Tie · corrodedCLT - FOUND SHEAR TIE CORRODED 1 INCH BY 4 INCH AREA, BS 1701, BETWEEN S28L AND S28R. REMOVED AND REPLACED SHEAR TIE CLIPS PER SRM 51-20-01 AND EA 69735. (M)SDR RRXA11230Doubler · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FLOOR BEAM AT STA.1560 AND LBL50, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM51-1-20D ANSDR SIMA200115606Angle · corrodedREINFORCEMENT ANGLE AND INTERCOSTAL BETWEEN FS 236.5 AND 258 HAS SURFACE CORROSION. REMOVED AND REPLACED ANGLE IAW SAAB SRM 51-40-40 AND 51-40-21. (M)SDR AALA20011241Longeron · crackedTUL - FOUND LONGERON NR 3 LEFT CRACKED AT STATION 160. ERPAIRED PER SRM 53-02 WITH LONGERON SPLICE. (M)SDR DL72L010916Beam · crackedINSPECTION OF THE RT VENTRAL STAIRWAY TORQUE BOX PER BAC S/B 727-53-0129 AND AD 94-07-08 REVEALED A TYPICAL CRACK IN THE UPPER AFT HORIZONTAL BEAM AT FS 1273. THE CRACKED PART WAS REMOVED AND A NEW PART INSTALLED. THE REPAIR WAS ACCOMPLISHED PER THE S/B AND SDR MWEA010849Shear Tie · crackedCENTER FUEL TANK UPPER SHEAR TIE CRACKED BETWEEN STRINGERS 4 AND 5 AT XCW 0 RIGHT. REMOVED UPPER SHEAR TIE AND SHIM, INSTALLED NEW UPPER SHEAR TIE AND SHIM.SDR MWEA010845Shear Tie · damagedSHEAR TIE IN AFT CARGO COMPARTMENT HAS A DENT, GOUGES AND 5 ELONGATED HOLES FOR FUSELAGE SKIN RIVETS, LOCATED BETWEEN LONGERON 22R AT STATION 1231. REMOVED SHEAR TIE, FABRICATED AND DRILLED REPAIR ATTACH ANGLE AND INSTALLED SHEAR TIE.SDR MWEA010844Door Frame · damagedREPAIR FORWARD CARGO DOOR JAMB TO ACCOMMODATE ENGINEERING ORDER 2-52-0003, REPAIRED.SDR 0105039927Longeron · crackedDuring an Hck in ATL, the longeron 26r end fitting was found cracked at station 598. Repaired per EA 99-181209.SDR 0104489927Fitting · crackedDuring H ck in ATL the longeron 26r end fitting was found cracked at sta 598. Repaired per EA. 99-181209.SDR RRXA11220Fitting · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO INTERCOSTAL FRAME ATTACH FITTING AT STA.1240 AND L33R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DCSDR RRXA11216Angle · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO AFT ACCY COMPARTMENT FLOOR BEAM AT STA.1640 AND LBL32, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IASDR UPS01436142Shear Tie · crackedINSPECTION TYPE:C M/D - BS 1880 RT BETWEEN STR 13 - 14 FOUND SHEAR TIE CRACK. M/D BS 1880 STR 13R - 14R SHEAR TIE REPLACED AS PER SRM 51-10-01.SDR AWXA0001817Door Frame · crackedaft cargo FWD doorway frame cracked from just above stop fitting NR 5 to area covered by fitting (refer to AWA EO 53-10-01) marked APPROX STA 807. replaced FWD frame segment IAW REF DWG 65C35243(-3) and DWG 65-47959(-2) and REF SRM 51-10-1 pg 8 and SRM 51-30-SDR 2001F00394Structure · corrodedSNOW WHITE POWDER AND CORROSION AT BS 481 FROM STRINGER 4L TO 4R. REPAIRED BS 481 FROM STRINGER 4L AND 4R IAW AVBORNE DWG NR 355QS AND SIE 8110-3. (M)SDR 2001F00393Structure · corrodedFOUND COCKPIT BS 259 BETWEEN STRINGER 6L AND 7L HAS WHITE POWER AROUND DOUBLER EDGE. INSTALLED DOUBLER REPAIR IAW B727 SB 727-53-0084 AND DRAWING NR 69-62161 AT BS 259 BTW STRINGER 6L AND 7L BTW STRINGER 6L AND 7L. (M)SDR RRXA11214Fitting · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO A-PIT FRAME FITTING AT STA.270 AND L30R-L31R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51SDR CALA0100527Beam · corrodedINSPECTION FOUND AFT CARGO DOOR JAMB BEAM CORRODED. THE LOWER DOOR JAMB BEAM WAS REMOVED AND A NEW LOWER DOOR JAMB BEAM WAS INSTALLED USING A DOUBLER AND SPACER IAW SRM 51-30-5 AND 51-30-2.SDR RRXA11209Frame · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER LIP OF FRAME AT STA.1120 AND L31R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 5SDR RRXA11208Longeron · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO LONGERON 31L AT STA.660, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-20D, 53-1-0. (SDR RRXA11207Fitting · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO AFT ACCY. COMPARTMENT FLOOR BEAM FITTING AT STA1660 AND L21R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED ISDR 01FDEA00425Door Frame · crackedR-3 DOOR BS 1294-1300 AFT DOOR FRAME LWR RELIEF HOLE IN BOTTOM OF FRAME CRACK. FAB, STOP DRILL CRACK INSTALL DOUBLER PER IAW DC10 SRM 53-50-00 FIG 19.SDR 01FDEA00424Door Frame · crackedL2 DOOR FRAME HAS PUNCTURE FWD UPPER. REMOVED, REPLACED AND FAB PER IAW DC10 SRM 51-21-01 & 53-00-01.SDR DL757010907Door Frame · corrodedTHE LOWER DOOR SILL CHORD OF THE C2 DOOR CUTOUT WAS CORRODED AND REQUIRED REPLACEMENT. TO ALLOW REMOVAL AND INSTALLATION OF A NEW CHORD, THE OUTER CHORD OF THE FS 1440 DOOR OPENING FRAME WAS CUT NEAR STRINGER 27R AND THE LOWER SECTION REMOVED. A NEW SECTION SDR QXEA0101018Structure · damagedYYC - FUSELAGE, TAIL SECTION, OBLIQUE FRAME 16-2 AT STRINGER 59-61, WEB, OIL CANNING. REPAIRED IAW FOKKER SRM 53-02-01, PAGE 4, FIGURE 2, SRM 51-31-01, PARAGRAPH 7, PAGES 13 AND 14.SDR QXEA0100973Door Frame · corrodedYYC - LIGHT CORROSION AROUND MAIN CABIN DOOR HINGE FLANGE AREA ON AIRFRAME AROUND BOLT HOLES. REPAIED IAW FOKKER SRM 53-01-01, PARAGRAPH 4, AND SRM 51-10-4, PARAGRAPH 4.SDR UPS01436086Door Frame · crackedINSPECTION TYPE:C, M/D - L5 DOOR FWD CUTOUT BETWEEN STR 24 & 25 CRACKED. REPAIRED AS PER SRM 53-10-04 FIG 34.SDR UPS01236105Stringer · corrodedINSPECTION TYPE:C STRINGER TERMINAL FITTING CORRODED AT BS 1183 STR 18L REMOVED CORRODED STRINGER BS 1183, STR18L. PER SRM 51-30-2, FABRICATED STRINGER TERMINAL FITTING PER BOEING DRAWING 65-242276 AND B727 SRM 51-10-2 TREATED AND PRIMED. INSTALLED STRINGESDR ABXA010349Shear Tie · crackedSHEAR TIE APPROXIMATELY FS 432 LONGERON 16 RIGHT CRACKED. REPLACED SHEAR TIE FS 432 LONGERON 16 RIGHT IAW DC-9 SRM.SDR ABXA010347Shear Tie · crackedRIGHT FUSELAGE FRAME SHEAR TIE AT STATION 1021 HAD CRACK AT RIVET BETWEEN LONGERON 14 AND 15 RIGHT. REPAIRED SHEAR TIE AT STATION 1021 BETWEEN LONGERON 14 RIGHT - 15 RIGHT IAW DC-9 SRM 53-03, FIGURE 3.SDR UIEA01057Skin · crackedDURING HFEC INSPECTION PER SB 747-53A2488 FOUND LOWER LOBE AFT CARGO COMPT DOOR UPPER FORWARD CUTOUT WITH TWO CRACK INDICATIONS, ONE FROM FASTENER HOLE TO RADIUS CUTOUT, THE OTHER 7MM LONG FROM FASTENER HOLE. AREA TRIMMED OUT. FILLER AND STACK DOUBLER FABRICSDR C1HA200195010Shear Tie · corrodedSHEAR TIE CORRODED. REPAIRED PER SRM 53-30-1, 53-10-4 AND 53-30-4.SDR RRXA11190Splice · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO SPLICE AT STA.610 AND L31L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-20D, 53-1-01 ANSDR AT0100180Door Frame · crackedFOUND AFT PRESSURE BULKHEAD DOOR JAMB CRACKED. REMOVED UPPER DOOR JAMB AND FRAME IAW DC9 SRM 53-05, 53-01, AND SB 53-137 REV A DRAWING JD600-88.SDR CALA0100516Door Frame · corrodedINSPECTION FOUND MID CARGO DOOR LOWER JAMB BEAM CORRODED AROUND RIVNUTS. THE DOOR JAMB WAS REPAIRED IAW ECRA 5310-03027.SDR RRXA11185Frame · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FRAME AT STA.460 AND L27R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. REMOVED CORROSION AND FOUND TO BE WITHIN LIMITS IAW DC-8 SRMSDR RRXA11181Angle · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO FLOOR SUPPORT ANGLE AT STA.1260 AND L33R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-2SDR QXEA0100997Structure · corrodedYYC - SURFACE CORROSION FOUND ON SUPPORT BLO BETWEEN STATION 3870 TO STATION 4610. REPAIRED IAW FOKKER SRM 51-10-04, PARAGRAPH 4, PAGE 7.SDR RRXA11169Angle · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO FLOOR SUPPORT ANGLE AT STA.1280 AND L31L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DHSK606-749.SDR RRXA11168Angle · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO FLOOR SUPPORT ANGLE AT STA.1300 AND L33R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DHSK 606-749.SDR QXEA0100974Structure · crackedYYC - NOSE LANDING GEAR BAY LEFT-HAND WALL CRACK ABOVE LOWER RIVET LINE AT STATION 3050. REPAIRED IAW FOKKER SRM 53-02-18, FIGURE 12.SDR UPS01236100Bulkhead · crackedINSPECTION TYPE:C CRACKS AT BULKHEAD STA 294.5 RBL 12, NOSE LANDING GEAR WHEEL WELL, INSPECTED. INSPECTED NLG WHEEL WELL BULKHEAD AND VERIFY CRACK AS PER B727 NAT MANUAL PART 6 51-00-00 FIG 4. REMOVED VERTICAL ANGLE TO ACCESS REPAIR AND CUT OUT CRACK AREASDR SWAA011566Shear Tie · crackedDURING SCHEDULED D-CHECK, FOUND CRACKED SHEAR TIE AT BS 1040, BETWEEN STR 2R & 3R. REPAIRED SHEAR TIE PER SRM.SDR QXEA0101006Structure · damagedYYC - FUSELAGE TAIL SECTION SKIN/STRINGERS BUCKLED AT RIGHT-HAND STATION 20285, STRINGERS 53, 54, 55. REPAIRED IAW HORIZON AIR EA 4-55-291.SDR 01FDEA00389Door Frame · dentedNR 3 CARGO DOORWAY FWD FRAME AT BS 1090 IS DENTED WITH A GOUGE IN THE CTR LOCATED BETWEEN NR 1 STOP PAD AND LATCH PLATE. R&R PER FEDEX EA 7-5310-56599, SRM 51-10-2, 51-20-4, 51-30-2.SDR 2001UALA00831Crease Beam · corrodedRT CREASE BEAM CORRODED, STA 1125. MAJOR REPAIR ACCOMPLISHED. INSTALLED NEW CREASE BEAM WEB.SDR SWAA011548Shear Tie · crackedDURING SCHEDULED D-CHECK, FOUND SHEAR TIE CRACKED AT BS 360, STR 14R. REPAIRED SHEAR TIE PER SRM.SDR 2001UALA00818Shear Tie · corrodedBS 434 STRINGER 37L - 38L SHEAR TIE CORRODED. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED REPAIR IN ACCORDANCE WITH BAC DRAWINGS 140T2102 AND 143T1001.
Back to JASC 5310